30 Series Calibrator  psi 

„ „ACCURACY–PRESSURE MEASUREMENT
0 to 110% of Range: ±(0.05% of Reading + Floor Term)
69.8
(2.75)
DIMENSIONS ARE IN MM (IN)
Includes all effects of linearity, hysteresis, repeatability,
temperature, and stability for one year.
Floor Term: 0.005% of FS or display resolution,
whichever is greater All models indicate vacuum, but vacuum specification applies
to 16 psi, 36 psi, and 300 psi models only.
Vacuum: ±(0.25% of Reading
+ Vacuum Floor Term) Not recommended for continuous use below -14.5 psi. Refer to
30 Series Pressure Calibrator MICRO-USB
XP2i-DP data sheet for gauges that are intended for continuous CONNECTION
Vacuum Floor Term: 0.004 psi for 16 and 36 psi high vacuum use. 2 LINE
0.01 psi for 300 psi
137.2 8 CHARACTER
(5.40) LCD DISPLAY

„„ACCURACY– MILLIAMPERES 0 4mm


SHIELDED
Accuracy: ±(0.025% of Reading + 0.001 mA) Includes all effects of linearity, hysteresis, repeatability,
temperature, and stability for one year. BANANA JACKS
Range: 0 to 55 mA
mA can be displayed as a percentage, where 0 to 100% A
Resolution: 0.001 mA corresponds to either 4 to 20 mA or 10 to 50 mA. Intrinsically Safe

Connection: 4 mm jacks, 19 mm (0.75") spacing Jacks are compatible with safety sheathed banana plugs. SENSOR
B DIAPHRAGM
LOCATIONS

„„OPERATING TEMPERATURE 1/8" FNPT 29.2


(1.15)
Temperature Range: 0 to 50° C (32 to 122° F) Non-condensing. No change in accuracy over operating PRESSURE PORTS
temperature range. Gauge must be zeroed to achieve rated
specification.

„„DISPLAY
DO NOT EXCEED MAXIMUMS

PRESSURE PORT VOLUMETRIC DATA:


Screen: 2 lines of up to 6 digits, LCD readable in sunlight.
5 mm (0.2") high LP distance to diaphragm ( A to B ): 22.4 (0.88")
Changes to reading rate requires software: ConfigM30 is a free
LP volume: 2 ml (0.13 cubic inches)
Display Rate: 2 readings/second (Adjustable to download from ametekcalibration.com.
HP distance to diaphragm ( A to B ): 17.8 (0.70")
1, 3, or 3.7 readings/second)
HP volume: 1 ml (0.06 cubic inches)

4534 . L  30 Series psi Data Sheet


Page 1 of 5
30 Series Calibrator  psi 

„„POWER
The 30 Series is Intrinsically Safe only if powered by one of the following battery types.
„„CERTIFICATIONS
II 2G Ex ia IIC T4
ATEX/IECEx: Approved Battery Type Ta= Marking FTZU 06 ATEX 0010X
ATEX
Duracell Alkaline 9V, MN 1604
Energizer Alkaline 9V, 522 0 to 50° C II 2G Ex ia IIC T4 Gb
Ex ia IIC T4 Gb IECEx FTZU 10.0018X
Energizer Lithium 9V, L522
Varta High Energy Alkaline 9V, 4922 0 to 45° C
Exia Intrinsically Safe and Non-incendive for Hazardous
Locations: Class I, Division 1, Groups A, B, C and D, Temperature
CSA: Approved Battery Type Marking
Code T4 or T3C. For hazardous location product warnings, refer
Duracell Alkaline 9V, MN 1604 to the operation manual.
Energizer Alkaline 9V, 522 Class I, Division 1, A, B, C, D T4
Energizer Lithium 9V, L522 30 Series complies with the Electromagnetic Compatibility and
Varta High Energy Alkaline 9V, 4922 Class I, Division 1, A, B, C, D T3C the Pressure Equipment Directives.

1 x 9V: 90 hours, typical Uses one alkaline 9V battery. Use of USB interface reduces
operating time. 30 Series complies with the Australian Radiocommunications
For hazardous location product warnings, refer to the
(Electromagnetic Compatibility) Standard 2008
operation manual.

„„DATA/COMMUNICATION 30 Series is approved for use as a portable test instrument for


Marine use and complies with Det Norsjke Veritas’ Rules for Classifi-
Digital Interface: micro-USB Free Labview drivers available online.
cation of Ships, High Speed & Light Craft and Offshore Standards.
For hazardous location product warnings, refer to the
operation manual.

„„ENCLOSURE
Model 31≤300 psi: 342 g (12.0 oz) Weight includes batteries.

* Model 31≤300 psi: 428 g (15.0 oz) *SPSS optional manifold.

Model 31≥1500 psi: 360 g (13.0 oz) Nylon carry case included.

Model 33: 400 g (14.0 oz)


* Model 33: 485 g (17.0 oz)
Housing: Extruded aluminum
Keypad and Labels: UV resistant polyester

4534 . L  30 Series psi Data Sheet


Page 2 of 5
30 Series Calibrator  psi 

„„SENSOR ≥ 1500 psi „„STANDARD DELIVERY


Wetted Materials: 316 stainless steel All welded with a permanently filled diaphragm seal.
• 30 Series Calibrator
Diaphragm Seal Fluid: Silicone Oil
• CD Manual
Connection: Bottom, 1⁄8 " female NPT
• ISO 17025 Accredited Calibration Certificate, NIST Traceable
„„SENSOR ≤ 300 psi • Carry Case and Strap (P/N 2490)
Wetted Materials: 316 stainless steel, Viton® (o-ring) Viton o-ring is internal.

Anodized aluminum penetrated All welded with a permanently filled diaphragm seal. „„ACCESSORIES
with PTFE (polytetrafluoroethylene) Magnetic Hanging Strap P/N 5203
Diaphragm Seal Fluid: Silicone Oil Test Lead Kit P/N 1351
Connection: Bottom, 1⁄8 " female NPT USB A to Micro USB Cable P/N 4431
Waterproof Carrying Case P/N 2888
„„STORAGE TEMPERATURE
Temperature Range: -20 to 70° C (-4 to 158° F) Batteries should be removed if stored for more than
one month. „„COMPLEMENTARY PRODUCTS
„„TSPECIAL

FEATURES
he following requires the use of ConfigM30 software
Crystal Engineering offers a wide range of products that
work with the 30 Series:

User Defined Unit: Allows the user to define and display any pressure units not included,
• Fittings that connect without tools, safely and without leaks
or to use the gauge to display force, level, or other pressure related parameters. • Lightweight, super flexible high pressure hoses
Reduce or increase displayed resolution.
• Pneumatic hand pumps
Remove: Unwanted pressure units from Units button. • Hydraulic hand pumps
Password Protect: Changes to configuration or userspan calibration factor(s). • Portable pressure comparators
Save: Configuration to a file. • Software, for the quickest way to calibrate pressure transmitters
Copy: Configuration to other calibrators. and gauges

Viton is a registered trademark of DuPont Performance Elastomers.

4534 .  L  30 Series psi Data Sheet


Page 3 of 5
30 Series Calibrator  psi 

„„RANGE & RESOLUTION TABLE „„DUAL PRESSURE SENSORS


Display Resolution Model 33 callibrators have dual pressure sensors. This chart shows all of the
Range Over- in in mm mm cm available sensor combinations. 
P/N psi kg/cm2 bar mbar kPa MPa
(psi) pressure H2O Hg Hg H 2O H2O
Second Pressure Ranges
16 16 6.5 x 0.001 0.01 0.001 0.01 1 0.0001 0.1 0.01
300 psi 1500 psi 3000 psi 5000 psi
36 36 3.0 x 0.001 0.01 0.001 0.01 1 0.0001 0.1 0.01
300 300 2.0 x 0.01 0.1 0.01 0.1 1 0.001 0.001 0.1 First Pressure Ranges 16 psi    
1500 1500 2.0 x 0.1 0.01 0.01 1 0.001 36 psi    
3000 3000 1.5 x 0.1 0.01 0.01 1 0.001 300 psi  
5000 5000 1.5 x 0.1 0.01 0.01 1 0.001
Model 31 calibrators are not available in this range.

„„ORDERING INFORMATION
Intrinsic 1st Pressure 2nd Pressure Pressure Pressure AMETEK offers a variety of solutions for pressure genera-
Model — / Pump System* Carrying Case~
Safety Range P/N Range P/N Unit Manifold
tion and measurement. Our line of products for pressure
IS PSI
generation includes everything from small pneumatic
Single Sensor. . . 31 Standard. . . . . . . . (omit) No Pump. . . . (omit)
hand pumps to a precision, hydraulic pressure comparator
Dual Sensor. . . . 33 Stainless Steel. . . -SPSS System A. . . . -AXX Aluminum . . . . (omit)
capable of generating up to 15 000 psi / 1000 bar / 100 MPa.
System A. . . . -AHX Waterproof. . . . . . . -W
System B. . . . . -BXX All of our pumps may be ordered as part of a Pump System,
SAMPLE PART NUMBERS System B. . . . . -BHX complete with a 30 Series and delivered in a sturdy carry-
~ The Waterproof Case is
IS31-36PSI. . . . . . . . . . . . . . . . . . . . . . . . . . Calibrator with one sensor (36 psi). System C. . . . . -CXX an option for Systems A, B,
ing case with custom insert.
IS33-16/1500PSI-SPSS . . . . . . . . . . . . . Calibrator with two sensors (16 psi and 1500 psi) and C only.
System C. . . . . -CHX
The Waterproof Case is
with two stainless steel manifolds. System D. . . . -DOX * Refer to the following page for a more detailed description
the only option for Systems
IS33-36/3000PSI-SPSS-HOX-W. . . . . Calibrator with two sensors (36 psi and 3000 psi) System D. . . . -DWX G and H. of each pump system.
and two stainless steel manifolds with a System H pump system System E. . . . . -EOX
and a waterproof carrying case. System F. . . . . -FOV
System F. . . . . -FWV
XXOrdering a Pump System Only
System G. . . . -GOX
Any pump system, carrying case, and connection fittings for a 30 Series calibrator may be ordered
System G. . . . -GWX
separately from the calibrator. Enter IS30-NONE followed by the Pump System part number and the
System H . . . . -HOX
Carrying Case option code.

SAMPLE PART NUMBER


IS30-NONE-HOX-W . . . . . . . . . . . . . . . . . System H pump system with a waterproof carrying case.

4534 .  L  30 Series psi Data Sheet


Page 4 of 5
30 Series Calibrator  psi 

„„PUMP SYSTEMS OVERVIEW


Pump Case Options
System Part Number Pressure Range Pneumatic Hydraulic Hand Pump Bench Top Included Pump Aluminum Waterproof (Pelican Case)

AXX 0 to 30psi / 2 bar   T-960-CPF  


System A (or)
AHX 0 to 580 psi / 40 bar   T-970-CPF  

BXX -25 inHg to 30 psi / - 0.85 to 2 bar   T-965-CPF  


System B (or)
BHX -27 inHg to 580 psi / - 0.91 to 40 bar   T-975-CPF  

CXX 0 to 3000 psi / 200 bar (Oil)


   T-620-CPF  
System C (or)
CHX 0 to 5000 psi / 350 bar (Oil)
   T-620H-CPF  

DOX 0 to 5000 psi / 350 bar (Oil)


   P-018-CPF 
System D
DWX 0 to 5000 psi / 350 bar (Water)
   

P014-CPF
System E EOX 0 to 10 000 psi / 700 bar (Oil)
   

FOV 0 to 15 000 psi / 1000 bar (Oil)


   T-1-CPF 
System F
FWV 0 to 15 000 psi / 1000 bar (Water)
   

GOX 0 to 15 000 psi / 1000 bar (Oil)


   GaugeCalHP 
System G
GWX 0 to 15 000 psi / 1000 bar (Water)
   

-27 inHg to 580 psi / - 0.91 to 40 bar   T-975-CPF 


System H HOX (and)
0 to 5000 psi / 350 bar (Oil)
   T-620H-CPF 

ametekcalibration.com 4534 .  L  30 Series psi Data Sheet


© 2017 Crystal Engineering Corporation 708 Fiero Lane, Suite 9, San Luis Obispo, California 93401-8701 Page 5 of 5