JNR PAR 36 7 10 JNR-8016: PR Lighting Ltd. 1582 Xingye Avenue, Nancun Panyu Guangzhou, 511442 China TEL: +86-20-3995 2888

This document provides safety instructions and maintenance guidelines for the JNR PAR 36 7*10 LED lighting fixture. It outlines important information for unpacking, installing and operating the fixture safely. Maintenance instructions include cleaning guidelines to keep the lights in good condition and extend their lifetime. The document also provides details on the fixture's DMX channel functions in 4-channel and 9-channel modes.

Uploaded by

Mathias Ky
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views6 pages

JNR PAR 36 7 10 JNR-8016: PR Lighting Ltd. 1582 Xingye Avenue, Nancun Panyu Guangzhou, 511442 China TEL: +86-20-3995 2888

This document provides safety instructions and maintenance guidelines for the JNR PAR 36 7*10 LED lighting fixture. It outlines important information for unpacking, installing and operating the fixture safely. Maintenance instructions include cleaning guidelines to keep the lights in good condition and extend their lifetime. The document also provides details on the fixture's DMX channel functions in 4-channel and 9-channel modes.

Uploaded by

Mathias Ky
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

JNR PAR 36 7*10

PR LIGHTING LTD.
http://www.pr-lighting.com
1582 Xingye Avenue, Nancun Panyu
JNR-8016
Guangzhou, 511442 China
TEL: +86-20-3995 2888
1 SAFETY INSTRUCTIONS 10 MAINTENANCE AND CLEANING
The following points have to be considered during the inspection:
CAUTION
Becareful with your operations.With a dangerous voltage you cansuffer a 1) All screws for installing the devices or parts of the device have to be tightly
dangerous electric shock when touching wires! connected and must not be corroded.

2) There must not be any deformations on the housing, color lenses, fixations and
This device has left the factory in perfect condition. In order to maintain this
installation spots (ceiling, suspension, trussing).
condition and to ensure a safe operation, it is absolutely necessary for the user to
follow the safety instructions and warning notes written in this user manual. 3) Mechanically moved parts must not show any traces of wearing and must not
rotate with unbalances.

IMPORTANT 4) The electric power supply cables must not show any damage, material fatigue or
Damages caused by the disregard of this user manual are not subject to warranty.
sediments.
The dealer will not accept liability for any resulting defects or problems.

If the device has been exposed to temperature changes due to environmental changes,
Further instructions depending on the installation spot and usage have to be
do not switch it on immediately. The arising condensation could damage the device.
adhered by a skilled installer and any safety problems have to be removed.
Leave the device switched off until it has reached room temperature.

This device falls under protection-class I. Therefore it is essential that the device be
earthed. CAUTION
Disconnect from mains before starting maintenance operation.
The electric connection must carry out by qualified person.

The device shall only be used with rate voltage and frequency.

Make sure that the available voltage is not higher than stated at the end of this manual. In order to make the lights in good condition and extend the life time, we suggest a
regular cleaning to the lights.
Make sure the power cord is never crimped or damaged by sharp edges. If this would
be the case, replacement of the cable must be done by an authorized dealer. 1) Clean the inside and outside lens each week to avoid the weakneness of the lights
due to accumulation of dust.
Always disconnect from the mains, when the device is not in use or before cleaning it.
Only handle the power cord by the plug. Never pull out the plug by tugging the power 2) Clean the fan each week.
cord. 3) A detailed electric check by approved electrical engineer each three month, make
During initial start-up some smoke or smell may arise. This is a normal process and sure that the circuit contacts are in good condition, prevent the poor contact of
does not necessarily mean that the device is defective, it should decrease gradually. circuit from overheating.

Please don't project the beam onto combustible substances.

Fixtures cannot be installed on combustible substances, keep more than 50cm We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth.
distance with wall for smooth air flow, so there should be no shelter for fans and Never use alcohol or solvents.
ventilation for heat radiation. There are no serviceable parts inside the device. Please refer to the instructions
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively under “Installation instructions”.
replaced by the manufacturer or his service agent or a similar qualified person in order Should you need any spare parts, please order genuine parts from your local dealer.
to avoid a hazard.

.01. .10.
9 DMX CHANNELS 2 UNPACKING
4CH Mode Thank you for choosing our JNR PAR 36 7*10. For your own safety, please read this
Channel Function Value Description manual before installing the device. This manual covers the important information
1 Red 0-255 0-100% Red dimmer on installation and applications. Please install and operate the fixture with following
2 Green 0-255 0-100% Green dimmer instructions. Meanwhile, please keep this manual well for future needs.
3 Blue 0-255 0-100% Blue dimmer
The JNR PAR 36 7*10 is made of a new type of high temperature strength of cast
4 White 0-255 0-100% White dimmer
aluminum casing with nice outlook. The fixture is designed and manufactured
strictly following CE standards, complying with international standard DMX512
9CH Mode protocol. It’s available independently controlled and linkable with each other for
Channel Function Value Description operation. And it is applicable for large-scale live performances, theater, studio,
1 Dimmer 0-255 0-100% Linear dimmer nightclubs and discos.
2 Red 0-255 0-100% Red dimmer The JNR PAR 36 7*10 adopts 7PCS high power 10W 4-IN-1 LEDs which features high
3 Green 0-255 0-100% Green dimmer
brightness and stability. Please carefully unpack it when you receive the fixture and
4 Blue 0-255 0-100% Blue dimmer
check whether it is damaged during the transportation. And please check whether
5 White 0-255 0-100% White dimmer
the following items are included inside the box:
6 Strobe 0-015 LED OFF
016-255 Strobe effect from slow to fast
7 Auto 0-015 LED OFF
016-255 Auto color mixing from slow to fast
8 Speed 0-255 Speed of auto color mixing and strobe from slow to fast Power Connector OPTIONAL
9 Sound 0-127 Sound control OFF (from controller)
Control 128-255 Sound control ON (from controller)

USA Standard UK Standard Euro Standard

① JNR PAR 36 7*10 1PC



② Signal Cable 1PC
④ ③ Safety Cable 1PC
④ User Manual 1PC

.02.
.09.
3 FEATURES & SPECIFICATIONS COMMON

2 1 1 2 1:Ground 1 1
2:Data(-) DMX+
3 3 3 3
Features 3:Data(+)
2 2
DMX-
• 7PCS 10W 4-IN-1 LEDs
• Specific optic system in 25 degree DMX Output DMX Input DMX512 OUT DMX512 IN
3-Pin XLR Socket 3-Pin XLR Socket 3-PIN XLR 3-PIN XLR
• Good light output with 130LUX@7M at full RGBW
• 50,000 hours life span and low power consumption
For installations where the DMX cable has to run a long
• Smooth and even color mixing
distance or is in an electrically noisy environment, such as 120 Ω
• High efficiency LED shutter with variable speed
in a discotheque, it is recommended to use a DMX
• Smooth LED linear dimmer
terminator. This helps in preventing corruption of the
• LED rainbow effect
digital control signal by electrical noise. The DMX
• 8 built-in default programs 3
terminator is simply an XLR plug with a 120 Ω resistor
• Strobe effect with 18 flashes per second and pulse effect 1 2
connected between pins 2 and 3,which is then plugged
• General dimming and blackout for all four colors PIN3
into the output XLR socket of the last fixture in the chain. PIN2
• 4/9 DMX Channels USITT DMX-512
Please see illustrations below.
• DMX512, master-slave and sound activated controllable or auto operation
• LED display
• Efficient low noise cooling system
• 3-pin XLR connectors IN/OUT
• -25°C~+35°C ambient temperature
8 MENU OPERATIONS
Specifications
Address setting
Input Voltage: AC90-240V 50/60Hz
Channel mode
LED Quantities: 7PCS 10W 4-IN-1 LEDs
Control Signal: DMX512, master-slave and sound activated or auto operation
Control Channel: 4/9 DMX Channels USITT DMX-512 Master/Slave setting

Power Consumption: 95W


Dimensions: 200(W)*140(D)*230(H)mm Strobe with color changing

Packing Dimensions: 260(W)*185(D)*290(H)mm


CO L1 5 Color 1 to color 15
Net Weight: 1.16kg
Gross Weight: 1.52kg Speed control of color changing
(SP01-SP08)

Red dimmer

Green cimmer

Blue dimmer

W h it White dimmer

te te Color auto test:R,G,B,W

service time (H)

.03. .08.
Regardless of the rigging option you choose for your JNR PAR 36 7*10 , always be sure 140
to secure your fixture with a safety cable. The fixture provides a built-in rigging point
for a safety cable on the hanging bracket as illustrated above. Be sure to only use the
designated rigging point for the safety cable and never secure a safety cable to a
carrying handle.

230
210
195

7 DMX-512 CONTROL CONNECTIONS


Connect the provided XLR cable to the female 3-pin XLR output of your controller and 200 140
the other side to the male 3-pin XLR input of the pan can. You can chain multiple

Pan can together through serial linking. The cable needed should be two core,
screened cable with XLR input and output connectors. Please refer to the diagram
below.

DMX-512 connection with DMX terminator


4 PHOTOMETRIC DATA
Photometric Beam Angle Data 25°Beam Angle LUX × 0.0929=FC
LED DISPLAY
DOWN R 56 / 602 11 / 113 4 / 47 2 / 26
ENTER
FUNC G 100 / 1080 18 / 197 8 / 83 4 / 42
POWER IN
UP B 184 / 1975 35 / 372 14 / 152 7 / 80

DMX OUT W 112 / 1199 18 / 194 8 / 83 4 / 44


DMX IN
RGBW 466 / 5016 84 / 902 35 / 378 18 / 194 (FC/LUX)

25°

DMX IN

POWER IN

0m (0ft) 1m (3.3ft) 3m (9.8ft) 5m (16.4ft) 7m (23.0ft)

.07. .04.
from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture
5 OPERATION INSTRUCTIONS 6
is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).

· The JNR PAR 36 7*10 is an LED wash light for on-site decoration purpose. Always use and install the supplied safety cable as a safety measure to prevent
· Don’t turn on the fixture if it’s been through severe temperature difference like accidental damage and/or injury in the event the clamp fails.
after transportation because it might damage the light due to the environment Mounting points: Overhead mounting requires extensive experience, including
changes. So make sure to operate the fixture until it is in normal temperature. amongst others calculating working load limits, a fine knowledge of the installation
· This light should be keep away from strong shaking during any transportation or material being used, and periodic safety inspection of all installation material and the
movement. fixture. If you lack these qualifications, do not attempt the installation yourself.
· Don’t pull up the light by only the head, or it might cause damages to the Improper installation can result in bodily injury.
mechanical parts.
· Don’t expose the fixture in overheat, moisture or environment with too much dust Be sure to complete all rigging and installation procedures before connecting the
when installing it. And don’t lay any power cables on the floor. Or it might cause main power cord to the appropriate wall outlet.
electronic shock to the people. Clamp mounting: The JNR PAR 36 7*10 provides a unique mounting bracket
· Make sure the installation place is in good safety condition before installing the assembly, and the safety cable rigging point in one unit (see the illustration below).
fixture. When mounting this fixture to truss be sure to secure an appropriately rated clamp to
· Make sure to put the safety chain and check whether the screws are screwed the handle using a M10 screw fitted through the center hole of the handle. As an
properly when installing the fixture. added safety measure be sure to attached at least one properly rated safety cable to
· Make sure the lens are in good condition. It’s recommended to replace the units if the fixture using on of the safety cable rigging point.
there are any damages or severe scratch.
· Make sure the fixture is operated by qualified personnel who knows the fixture Satety Clamp Safety Cable
before using.
· Keep the original packages if any second shipment is needed.
· Don’t try to change the fixtures without any instruction by the manufacturer or
the appointed repairing agencies.
· It is not in warranty range if there are any malfunctions from not following the
user manual to operate or any illegal operation, like shock short circuit, electronic
shock, lamp broke, etc.

Truss installing
6 INSTALLATIONS
Cautions: For added protection mount the fixtures in areas outside walking paths,
seating areas, or in areas were the fixture might be reached by unauthorized personnel.

Before mounting the fixture to any surface, make sure that the installation area can
hold a minimum point load of 10 times the device’s weight.

Fixture installation must always be secured with a secondary safety attachment, such
as an appropriate safety cable.

Never stand directly below the device when mounting, removing, or servicing the fixture. Floor projection

.05. .06.