RCG Instrumentation Cables

Download as pdf or txt
Download as pdf or txt
You are on page 1of 38

RIYADH CABLES

Currently standing at an impressive 1850000 square meters, Riyadh Cables’ affiliates extend to
22 domestic/regional locations, including Riyadh/Saudi Arabia, United Arab Emirates and Iraq
Republic. The company manufactures and supplies all types of wire and cables at its state-of-art
facilities. Since its establishment in 1984, the company has always been keen on embracing a
comprehensive quality management program for evaluating and monitoring all corrective and
proactive action plans, bolstering its status as a pioneer in the Wire and Cable industry in the
Middle East.

Our Main Resources:

- Facilities spread over 1,850,000M2 across 22 locations.


- Team of 3500 employees.
- Turnover of USD 1.8 Billion (6 Billion SAR)
- Automated Business process with SAP ERP System
- Number #1 in sales in Middle East North Africa market.
- Number #4 in sales Worldwide.
- Having systems quality and product quality certifications, including but not
limited to:
o ISO 9001:2015 (Quality Management System)
o ISO 14001:2015 (Environmental Management System)
o ISO 45001:2018 (Occupational health and safety management system)
o OHSAS 18001:2007 (Health and Safety Management System)
o SASO Quality Mark (The Saudi Standards, Metrology and quality
organization)
o ESMA Quality Mark (The Emirates Authority for Standardization &
Metrology)

We are committed to achieving continuous improvement of the products, by improving


wire and cable design and manufacturing capabilities across all our product lines of Low
Voltage, Medium Voltage and High Voltage cable up to 500KV, electric wire, overhead
conductors, telephone – Copper and fiber optic cables, supported by in-house
manufacture of 8.0 mm diameter Copper Rod, 9.5 mm diameter Aluminum Rod, PVC
(polyvinyl chloride), low voltage XLPE(cross-linked polyethylene), LSHF (low smoke
halogen free) and drums, and satisfy our market and customer requirements, based on
our ability to manufacture and supply products conforming to, amongst others, the
following standards:
1- BS (British Standard )
2- IEC (international Electro Technical Commission)
3- SASO (The Saudi Standards, Metrology and quality organization
4- (STC)Saudi Telecom Company
5- VDE (Association of Electrical Engineering)
6- DIN (German Institute for standard )
7- ASTM (American Society for testing and material)

Our Group Companies:

We act locally and internationally through our following Group companies / subsidiaries:

1- Riyadh Cable Group Company.


2- Saudi Modern Company for Metal, cables and plastic industry.
3- Saudi Modern Company for specialized Electrical Cables and wire industry.
4- Saudi Modern Company for Telephone Cable Industry.
5- National Cables Industry (NCI) United Arab Emirate (UAE).
6- Al-Rowad Cables Company (Iraq).

Our Vision:
To be a major manufacturer of a broad range of electrical cables covering low, medium ,
high and extra high voltage cables

Our Mission:

Continuously growing through providing superior services and solutions to our products
used worldwide in the fields of energy, general construction, oil & gas, renewables,
industrial, defense, rail transport, , mining and other specialty industry verticals, by investing
heavily in Research and developments, quality , System and human resources .

Our Values:
Our internal value built on four main pillars which is:

1 - People.

2 - System

3 - Quality
4 - After Sales Service.
With our above highlighted values, capabilities, expertise and strong track record, we
strive to uphold our commitment of providing high quality products and services, in
alignment with the latest technology developments, to our customers at all times, at
same time we will keep our focus on steady and sustainable growth, innovation, quality
of delivery, customer centric approach in achieving our goal to maintain and enhance
our market presence and reputation in the years ahead, leveraging on our performance
and success to date as the springboard for future achievements.

Development of Human Resources


Riyadh Cables is contributing to the process of human resource development in Saudi
Arabia by attracting nationals to work in all function within the company .mentoring and
training these precious human resources have contributed to the continual
improvement of individuals and company performance. The management of Riyadh
Cables has and ambitious development and training program geared to serve the
customer and make Riyadh Cables the best.

Export
Riyadh Cables is more than able to satisfy the local market, with its strong infrastructure
Riyadh Cables has established itself as a regional supplier, rapidly expanding it is
interests outside Saudi Arabia.

In order to execute a competitive and successful exporting policy, the company has
recruited an experienced team with the necessary international expertise. Market
research has been conducted domestically and internationally, investigating numerous
key factory such as geographical issue, demand, trend, prices, competition, channel of
supple and customer needs. A promotion Campaign has been used to compliment the
policy of Riyadh Cables as a regional supplier. At the heart of the successful export
campaign has been Riyadh Cables ability to consistently supply high quality cables on
time, to internationally accepted standards and at competitive prices.

Quality First
The mission of Riyadh Cables is based on the establishment of a strong technological
base, continuous improvement maintaining high quality standards and delighted
customers, from it is beginning Riyadh Cables has been totally “Committed to Quality”.

Research and development:


The foresight in understanding the future needs of the market as well as the technical
expertise is an essential strategy at Riyadh Cables in it is continuous journey of product
improvement.

Customer Services:
At Riyadh Cables we believe that every customer is important and each one can depend
on the special care we give to our customers.
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD UNSHIELDED.

Temperature rating : Û&

Related Specification : Generally as per 34-SAMSS-913.

Application : &DEOHFDQEHXVHGLQFDEOHWUD\FRQGXLWRUGLUHFWEXULDODSSOLFDWLRQIRU
,QVWUXPHQWDWLRQSURFHVVFRQWUROLQGU\RUZHWORFDWLRQ

Conductor : 6WUDQGHG DQQHDOHGSODLQFRSSHUWLQQHGFRSSHU DVSHU,(&


60228 FODVV-2.

Insulation : XLPE

Pair colour code : :KLWHDQG%ODFNZLWKSDLU QXPEHURQZKLWHFRQGXFWRU

Triad Colour code : :KLWe %ODFNDQGUHGZLWKWULDGQXPEHURQZKLWHFRQGXFWRU


Twisting : $OOSDLUVWULDGVDUHWZLVWHGWRFRXQWHUHOHFWURPDJQHWLFQRLVH

Assembly : 7ZLVWHGSDLUVWULDGVDUHFDEOHGZLWKQRQ-K\JURVFRSLF ILOOHUVLI


QHFHVVDU\DQGWKHHQWLUHDVVHPEO\LVFRYHUHGZLWKDSRO\HVWHU
WDSH

Jacket ([WUXGHGEODFN39&-DFNHWVKDOOEHIODPHUHWDUGDQWDVSHU
,(&-3-2LODQG6XQ-OLJKWUHVLVWDQW

Page 1
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD UNSHIELDED.

Standard cable dimensions:

Pairs.
Size Pairs Strands X Insulation Nominal Approx Approx
(mm²) diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1 7x0.43 0.40 1 6.4 49.29
1.0
2 7x0.43 0.40 1.2 9.4 93.99

3 7x0.43 0.40 1.2 10 119.58

4 7x0.43 0.40 1.5 11.5 163.22

6 7x0.43 0.40 1.5 13.4 222.62

8 7x0.43 0.40 1.5 15 278.68

10 7x0.43 0.40 1.8 17.4 361

12 7x0.43 0.40 1.8 18 410.29

16 7x0.43 0.40 1.8 19.8 515.75

20 7x0.43 0.40 1.8 22 625.16

24 7x0.43 0.40 2.1 24.9 769.89

Page 2
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD UNSHIELDED.

Size (mm²) Pairs Strands X Insulation Nominal Approx Approx


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1.5 1 7x0.52 0.40 1.0 6.9 62

2 7x0.52 0.40 1.5 11 135

3 7x0.52 0.40 1.5 11.6 171

4 7x0.52 0.40 1.5 12.6 211

6 7x0.52 0.40 1.5 14.9 292

8 7x0.52 0.40 1.8 17.2 392

10 7x0.52 0.40 1.8 19.3 476

12 7x0.52 0.40 1.8 19.9 545

16 7x0.52 0.40 1.8 22 692

20 7x0.52 0.40 2.1 25.1 879

24 7x0.52 0.40 2.1 27.7 1034

Page 3
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD UNSHIELDED.

Size (mm²) Pairs Strands X Insulation Nominal Approx Approx


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1 7x0.66 0.40 1.2 8.2 91
2.5

2 7x0.66 0.40 1.5 12.3 179

3 7x0.66 0.40 1.5 13 233

4 7x0.66 0.40 1.5 14.2 292

6 7x0.66 0.40 1.5 16.9 410

8 7x0.66 0.40 1.8 19.5 550

10 7x0.66 0.40 1.8 22 671

12 7x0.66 0.40 1.8 22.7 776

16 7x0.66 0.40 2.1 25.8 1033

20 7x0.66 0.40 2.1 28.7 1260

24 7x0.66 0.40 2.1 31.8 1488

Page 4
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD UNSHIELDED.

Triads
Size (mm²) Triads Strands X Insulation Nominal Approx Approx
diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1 7x0.43 0.40 1.0 6.7 62.13
1.0

2 7x0.43 0.40 1.5 11 137.33

3 7x0.43 0.40 1.5 11.6 175.4

4 7x0.43 0.40 1.5 12.6 216.4

6 7x0.43 0.40 1.5 14. 9 300.13

8 7x0.43 0.40 1.8 17.2 404.31

10 7x0.43 0.40 1.8 19.3 489.14

12 7x0.43 0.40 1.8 20 561.49

16 7x0.43 0.40 1.8 22.1 713.76

20 7x0.43 0.40 2.1 25.1 906.09

24 7x0.43 0.40 2.1 27.7 1066.73

Page 5
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD UNSHIELDED.

Size Triads Strands X Insulation Nominal Approx Approx


(mm²) diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1 7x0.52 0.40 1.0 7.3 80
1.5

2 7x0.52 0.40 1.5 12.1 175

3 7x0.52 0.40 1.5 12.8 228

0.40
4 7x0.52 1.5 13.9 284

6 7x0.52 0.40 1.5 16.5 400

8 7x0.52 0.40 1.8 19 537

10 7x0.52 0.40 1.8 21.5 655

12 7x0.52 0.40 1.8 22.2 756

16 7x0.52 0.40 1.8 24.6 971

20 7x0.52 0.40 2.1 28 1230

24 7x0.52 0.40 2.1 31 1453

Page 6
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD UNSHIELDED.

Size Triads Strands X Insulation Nominal Approx Approx


(mm²) diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1 7x0.66 0.40 1.2 8.6 118
2.5

2 7x0.66 0.40 1.5 13.6 238

3 7x0.66 0.40 1.5 14.4 318

4 7x0.66 0.40 1.5 15.8 402

6 7x0.66 0.40 1.8 19.4 599

8 7x0.66 0.40 1.8 21.7 767

10 7x0.66 0.4 0 2.1 25.2 977

12 7x0.66 0.40 2.1 26 1133

16 7x0.66 0.40 2.1 28.8 1458

20 7x0.66 0.40 2.1 32.1 1787

24 7x0.66 0.40 2.4 36.2 2170

Page 7
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED.

Temperature rating : 90 ˚C

Related Specification: Generally as per 34-SAMSS-913.


:
Application Cable can be used in cable tray, conduit or direct burial application for
Instrumentation / process control, in dry or wet location.

Conductor : Stranded annealed plain copper/tinned copper as per IEC 60228 class-2.

Insulation : XLPE

Pair colour code : White and Black with pair number on white conductor.
Triad Colour code : White, Black and Red with triad number on white conductor.
Twisting : All pairs/triads are twisted to counter electromagnetic noise.

Overall
Shielding : Twisted pairs/triads are cabled with non-hygroscopic fillers if necessary and the
entire assembly is shielded with aluminum polyester tape and a tinned copper
drain wire.

Jacket : Extruded black PVC Jacket shall be flame retardant as per IEC 60332-3-24,
Oil and Sun-light resistant

Standard cable dimensions:


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED.

Pairs.

Size (mm²) Pairs Strands X Insulation Nominal Approx Approx


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1.0 1 7x0.43 0.40 1 6.6 57.11

2 7x0.43 0.40 1.2 9.6 103.35

3 7x0.43 0.40 1.5 10.8 144.21

4 7x0.43 0.40 1.5 11.7 173.59

6 7x0.43 0.40 1.5 13.6 233.98

8 7x0.43 0.40 1.5 15.2 290.83

10 7x0.43 0.40 1.8 17.6 374.26

12 7x0.43 0.40 1.8 18.2 423.93

16 7x0.43 0.40 1.8 20 530.32

20 7x0.43 0.40 1.8 22.2 640.84

3
24 7x0.4 0.40 2.1 25.1 787.0
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED.

Size (mm²) Pairs Strands X Insulation Nominal Approx Approx


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1 7x0.52 0.40 1.2 7.5 77
1.5

2 7x0.52 0.40 1.5 11.2 145

3 7x0.52 0.40 1.5 11.8 182

4 7x0.52 0.40 1.5 12.8 222

6 7x0.52 0.40 1.5 15 304

8 7x0.52 0.40 1.8 17.4 407

10 7x0.52 0.40 1.8 19.5 490

12 7x0.52 0.40 1.8 20.1 560

16 7x0.52 0.40 1.8 22.2 708

20 7x0.52 0.40 2.1 25.3 896

24 7x0.52 0.40 2.1 27.9 1053


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED.

Size (mm²) Pairs Strands X Insulation Nominal Approx Approx


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
2.5 1 7x0.66 0.40 1.2 8.4 100

2 7x0.66 0.40 1.5 12.5 190

3 7x0.66 0.40 1.5 13.2 245

4 7x0.66 0.40 1.5 14.4 304

6 7x0.66 0.40 1.8 17.7 448

8 7x0.66 0.40 1.8 19.7 566

10 7x0.66 0.40 1.8 22.2 687

12 7x0.66 0.40 2.1 23.6 827

16 7x0.66 0.40 2.1 26 1050

20 7x0.66 0.40 2.1 28.9 1279

24 7x0.66 0.40 2.1 31.9 1509

Triads
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED.

Triads
Size (mm²) Triads Stra nds X Insulation Nominal Approx Approx
diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1.0 1 7x0.43 0.40 1 6.9 70.12

2 7x0.43 0.40 1.5 11.2 147.45

3 7x0.43 0.40 1.5 11.8 185.84

4 7x0.43 0.40 1.5 12.8 227.34

6 7x0.43 0.40 1. 5 15.1 312.22

8 7x0.43 0.40 1.8 17.4 417.56

10 7x0.43 0.40 1.8 19.5 503.47

12 7x0.43 0.40 1.8 20.1 576.13

16 7x0.43 0.40 1.8 22.3 730.72

20 7x0.43 0.40 2.1 25.3 923.32

24 7x0.42 0.40 2.1 27.3 1086.29


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED.

Size (mm²) Triads Strands X Insulation Nominal Approx Approx


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1.5 1 7x0.52 0.40 1.2 7.9 96

2 7x0.52 0.40 1.5 12.2 185

3 7x0.52 0.40 1.5 13 239

4 7x0.52 0.40 1.5 14.1 297

6 7x0.52 0.40 1.8 17.3 438

8 7x0.52 0.40 1.8 19.3 553

10 7x0.52 0.40 1.8 21.7 671

12 7x0.52 0.40 1.8 22.4 773

16 7x0.52 0.40 2.1 25.4 1026

20 7x0.52 0.40 2.1 28.2 1248

24 7x0.52 0.40 2.1 31.1 1473


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED.

Size (mm²) Triads Strands X Insulation Nominal Approx Approx


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
2.5 1 7x0.66 0.40 1.2 8.8 127

2 7x0.66 0.40 1.5 13.8 249

3 7x0.66 0.40 1.5 14.6 330

4 7x0.66 0.40 1.8 16.6 438

6 7x0.66 0.40 1.8 19.6 614

8 7x0.66 0.40 1.8 21.9 784

10 7x0.66 0.40 2.1 25.4 994

12 7x0.66 0.40 2.1 26.2 1151

16 7x0.66 0.40 2.1 29 1477

20 7x0.66 0.40 2.4 32.9 1854

24 7x0.66 0.40 2.4 36.4 2193


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED.

Temperature rating : Û&

Related 6SHFL¿FDWLRQ : Generally as per 34-SAMSS-913.

$SSOLFDWLRQ : &DEOHFDQEHXVHGLQFDEOHWUD\FRQGXLWRUGLUHFWEXULDODSSOLFDWLRQIRU
,QVWUXPHQWDWLRQSURFHVVFRQWUROLQGU\RU ZHWORFDWLRQ

&RQGXFWRU : SWUDQGHG DQQHDOHGSODLQFRSSHUWLQQHGFRSSHU as per


,(&FODVV-

,QVXODWLRQ : XLPE

3DLUFRORXUFRGH :KLWHDQG%ODFNZLWKSDLUQXPEHURQZKLWHFRQGXFWRU
7ULDG&RORXUFRGe :KLWH %ODFNDQG5HGZLWKWULDGQXPEHURQZKLWHFRQGXFWRU
Twisting $OOSDLUVWULDGVDUHWZLVWHGWRFRXQWHUHOHFWURPDJQHWLFQRLVH

Individual & Overall


Shielding : (DFKSDLUWULDGLVVKLHOGHGZLWKDOXPLQXPSRO\HVWHUWDSHDQG
DWLQQHGFRSSHUGUDLQZLUHIRUPD[LPXPHOHFWURVWDWLFQRLVH
DQGFURVVWDONUHMHFWLRQ $OOSDLUWULDGVKLHOGVDUHHOHFWULFDOO\
LVRODWHGIURPHDFKRWKHU,QGLYLGXDOO\VKLHOGHGSDLUVWULDGV
FDEOHGZLWKQRQ-K\JURVFRSLFILOOHUVLIQHFHVVDU\DQGWKHHQWLUH
DVVHPEO\LVVKLHOGHGZLWKDOXPLQXPSRO\HVWHUWDSHDQGD
WLQQHGFRSSHUGUDLQZLUH

Jacket : ([WUXGHGEODFN39&-DFNHWVKDOOEHIODPHUHWDUGDQWDVSHU
,(&-3- 2LODQGVXQ-OLJKWUHVLVWDQW

Standard cable diPHQVLRQV

Pairs
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED.

Size (mm²) Pairs Strands X ,QVXODWLRQ1RPLQDO $SSUR[ $SSUR[


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1.0  [ 0.40 1.5 11.7 147.04

3 [ 0.40 1.5  

4 [ 0.40 1.5 13.5 

 [ 0.40 1.5 15.9 305.4

[  


 0.40 407.57

[ 0.40   491.41


10

[   


 0.40

Size (mm²) Pairs Strands X ,QVXODWLRQ1RPLQDO $SSUR[ $SSUR[


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
 [ 0.40 1.5  
1.5

3 [ 0.40 1.5 13.5 

4 [ 0.40 1.5 14.7 

 [ 0.40   404

 [ 0.40   507

10 [ 0.40   

 [ 0.40   740


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED.

Size (mm²) Pairs Strands X InsuODWLRQ1RPLQDO $SSUR[ $SSUR[


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
  [ 0.40 1.5  

3 [ 0.40 1.5 15.1 

4 [ 0.40  17.1 

 [ 0.40   

 [ 0.40   

10 [ 0.40   

 [ 0.40   


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED.

Triads

Size (mm²) Triads Strands X ,QVXODWLRQ1RPLQDO $SSUR[ $SSUR[


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1.0  [ 0.40 1.5  

3 [ 0.40 1.5  

4 [ 0.40 1.5  

 [ 0.40   

 [ 0.40   

10 [ 0.40   

 [ 0.40   754.4

Size (mm²) Triads Strands X ,QVXODWLRQ1RPLQDO $SSUR[ $SSUR[


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)
1.5  [ 0.40 1.5 14 

3 [ 0.40 1.5  

4 [ 0.40   377

 [ 0.40   

 [ 0.40   

10 [ 0.40   

 [ 0.40   


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED.

Size (mm²) Triads Strands X ,QVXODWLRQ1RPLQDO $SSUR[ $SSUR[


diameterX thickness Jacket OD Weight
mm mm thickness mm (kg/km)

  [ 0.40 1.5  

3 [ 0.40   

4 [ 0.40   

 [ 0.40   703

 [ 0.40   

10 [ 0.40   

 [ 0.40  30.1 


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED ARMORED.

Temperature rating : Û&


Related Specification: Generally as per-34 SAMSS
- 913.

Application : Cable can be used in cable tray, conduit or direct burial application for
Instrumentation / process control, in dry or wet location.
Conductor : Stranded annealed plain copper/tinned copper as per IEC 60228 class-2.

Insulation : XLPE

Pair colour code : White and Black with pair number on white conductor.
Triad Colour code : White, Black and Red with triad number on white conductor.
Twisting : All pairs/triads are twisted to counter electromagnetic noise.

Overall
Shielding : Twisted pairs/triads are cabled with non - hygroscopic fillers if necessary
and the entire assembly is shielded with aluminum polyester tape
and a tinned copper drain wire.

InnerJacket : Extruded black PVC Jacket shall be flame retardant as per IEC 60332-3-24.

Armour : Round galvanized steel wires is applied with 90% minimum coverage.

Outer Jacket : Extruded black PVC Jacket shall be flame retardant as per IEC 60332-3-24,
Oil and sun-light resistant.
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED ARMORED.

Standard cable dimensions:

Pairs
Pairs Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
Size diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

1 7x0.43 0.40 1.0 6.6 0.8 8.2 1.8 11.8 246.56


1.0
2 7x0.43 0.40 1.2 9.6 0.8 11.2 1.8 14.8 362.42

3 7x0.43 0.40 1.5 10.8 1.25 13.3 1.8 16.9 538.87

4 7x0.43 0.40 1.5 11.7 1.25 14.2 1.8 17.8 595.46

6 7x0.43 0.40 1.5 13.6 1.25 16.1 1.8 19.7 716.57

8 7x0.43 0.40 1.5 15.2 1.25 17.7 1.8 21.3 820.51

10 7x0.43 0.40 1.8 17.6 1.6 20.8 2.1 25.0 1147.14

12 7x0.43 0.40 1.8 18.2 1.6 21.4 2.1 25.6 1217.71

16 7x0.43 0.40 1.8 20.0 1.6 23.2 2.1 27.4 1394.65

20 7x0.43 0.40 1.8 22.2 1.6 25.4 2.1 29.6 1588.38

24 7x0.43 0.40 2.1 25.1 1.6 28.3 2.4 33.1 1891.99


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED ARMORED.

Size Pairs Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

1 7x0.52 0.40 1.2 7.5 0.8 9.1 1.8 12.7 288.77


1.5
2 7x0.52 0.40 1.5 11.2 1.25 13.7 1.8 17.3 551.60

3 7x0.52 0.40 1.5 11.8 1.25 14.3 1.8 17.9 607.71

4 7x0.52 0.40 1.5 12.8 1.25 15.3 1.8 18.9 678.85

6 7x0.52 0.40 1.5 15.0 1.25 17.5 1.8 21.1 830.14

8 7x0.52 0.40 1.8 17.4 1.6 20.6 2.1 24.8 1171.02

10 7x0.52 0.40 1. 19.5 1.6 22.7 2.1 26.9 1335.14

12 7x0.52 0.40 1.8 20.1 1.6 23.3 2.1 27.5 1428.90

16 7x0.52 0.40 1.8 22.2 1.6 25.4 2.1 29.6 1657.18

20 7x0.52 0.40 2.1 25.3 2 29.3 2.4 34.1 2223.77

24 7x0.52 0.40 2.1 27.9 2 31.9 2.4 36.7 2502.11


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED ARMORED.

Pairs Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
Size diameterX mm thickness innerJacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

1 7x0.66 0.40 1.2 8.4 0.8 10.0 1.8 13.6 330.02


2.5

2 7x0.66 0.40 1.5 12.5 1.25 15.0 1.8 18.6 638.06

3 7x0.66 0.40 1.5 13.2 1.25 15.7 1.8 19.3 715.50

4 7x0.66 0.40 1.5 14.4 1.25 16.9 1.8 20.5 810.58

6 7x0.66 0.40 1.8 17.7 1.6 20.9 2.1 25.1 1222.92

8 7x0.66 0.40 1.8 19.7 1.6 22.9 2.1 27.1 1419.28

10 7x0.66 0.40 1.8 22.2 1.6 25.4 2.1 27.1 1635.26

12 7x0.66 0.40 2.1 23.6 1.6 26.8 2.1 31.0 1826.96

16 7x0.66 0.40 2.1 26.0 2 30.0 2.4 34.8 2411.59

20 7x0.66 0.40 2.1 28.9 2 32.9 2.4 37.7 2774.10

24 7x0.66 0.40 2.1 31.9 2 35.9 2.4 40.7 3147.11


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED ARMORED.

Triads
Size Triads Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

1 7x0.43 0.40 1.0 6.9 0.8 8.5 1.8 12.1 267.14


1.0

2 7x0.43 0.40 1.5 11.2 1.25 13.7 1.8 17.3 554.52

3 7x0.43 0.40 1.5 11.8 1.25 14.3 1.8 17.9 611.99

4 7x0.43 0.40 1.5 12.8 1.25 15.3 1.8 18.9 684.50

6 7x0.43 0.40 1.5 15.1 1.6 18.3 1.8 21.9 955.22

8 7x0.43 0.40 1.8 17.4 1.6 20.6 2.1 24.8 1182.25

10 7x0.43 0.40 1.8 19.5 1.6 22.7 2.1 26.9 1349.13

12 7x0.43 0.40 1.8 20.1 1.6 23.3 2.1 27.5 1445.60

16 7x0.43 0.40 1.8 22.3 1.6 25.5 2.1 29.7 1681.47

20 7x0.43 0.40 2.1 25.3 1.6 28.5 2.1 33.3 2038.11

24 7x0.43 0.40 2.1 27.9 2 31.9 2.4 36.7 2535.35


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED ARMORED.

Triads
Size Triads Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

1 7x0.52 0.40 1.2 7.9 0.8 9.5 1.8 13.1 315.91


1.5

2 7x0.52 0.40 1.5 12.2 1.25 14.7 1.8 625.52


18.3

3 7x0.52 0.40 1.5 13.0 1.25 15.5 1.8 19.1 701.02

4 7x0.52 0.40 1.5 14.1 1.25 16.6 1.8 20.2 793.63

6 7x0.52 0.40 1.8 17.3 1.6 20.5 2.1 24.7 1197.12

8 7x0.52 0.40 1.8 19.3 1.6 22.5 2.1 26.7 1388.38

10 7x0.52 0.4 0 1.8 21.7 1.6 24.9 2.1 29.1 1598.64

12 7x0.52 0.40 1.8 22.4 1.6 25.6 2.1 29.8 1728.60

16 7x0.52 0.40 2.1 25.4 2 29.4 2.4 34.2 2357.54

20 7x0.52 0.40 2.1 28.2 2 32.2 2.4 37.0 2710.71

24 7x0.52 0.40 2.1 31.1 2 35.1 2.4 39.9 3074.09


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD OVERALL SHIELDED ARMORED.

Size Triads Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

2.5 1 7x0.66 0.40 1.2 8.8 0.8 10.4 1.8 14.0 367.66

2 7x0.66 0.40 1.5 13.8 1.25 16.3 1.8 19.9 736.41

3 7x0.66 0.40 1.5 14.6 1.25 17.1 1.8 20.7 842.39

4 7x0.66 0.40 1.8 16.6 1.6 19.8 2.1 24.0 1170.05

6 7x0.66 0.40 1.8 19.6 1.6 22.8 2.1 27.0 1461.51

8 7x0.66 0.40 1.8 21.9 1.6 25.1 2.1 29.3 1720.74

10 7x0.66 0.40 2.1 25.4 1.6 28.6 2.4 33.4 2111.01

12 7x0.66 0.40 2.1 26.2 2 30.2 2.4 35.0 2520.39

16 7x0.66 0.40 2.1 29.0 2 33.0 2.4 37.8 2977.46

20 7x0.66 0.40 2.4 29.0 2 36.9 2.4 41.7 3536.22

24 7x0.66 0.40 2.4 36.4 2.5 41.4 2.7 46.8 4475.96


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED.

Temperature rating Û&

Related Specification: Generally as per 34-SAMSS-913.

Application : &DEOHFDQEHXVHGLQFDEOHWUD\FRQGXLWRUGLUHFWEXULDODSSOLFDWLRQIRU
,QVWUXPHQWDWLRQSURFHVVFRQWUROLQGU\RUZHWORFDWLRQ

Conductor : 6WUDQGHG DQQHDOHGSODLQFRSSHUWLQQHGFRSSHU DVSHU,(&FODVV-

Insulation : XLPE

Pair colour code :KLWHDQG%ODFNZLWKSDLUQXPEHURQZKLWHFRQGXFWRU


Triad Colour code :KLWH %ODFNDQGRHGZLWKWULDGQXPEHURQZKLWHFRQGXFWRU

Twisting $OOSDLUVWULDGVDUHWZLVWHGWRFRXQWHUHOHFWURPDJQHWLFQRLVH

Individual &
Overall
Shielding : (DFKSDLUWULDGLVVKLHOGHGZLWKDOXPLQXPSRO\HVWHUWDSHDQGDWLQQHGFRSSHU
GUDLQZLUHIRUPD[LPXPHOHFWURVWDWLFQRLVHDQGFURVVWDONUHMHFWLRQ$OOSDLUWULDGVKLHOGVDUHHOHFWULFDOO\
LVRODWHGIURPHDFKRWKHU,QGLYLGXDOO\VKLHOGHGSDLUVWULDGVFDEOHGZLWKQRQ-K\JURVFRSLFILOOHUVLI
QHFHVVDU\DQGWKHHQWLUHDVVHPEO\LVVKLHOGHGZLWKDOXPLQXPSRO\HVWHUWDSHDQGDWLQQHGFRSSHUGUDLQ
ZLUH

Inner Jacket ([WUXGHGEODFN39&-DFNHWVKDOOEHIODPHUHWDUGDQWDVSHU,(&-3-

Armour : RRXQGJDOYDQL]HGVWHHOZLUHVLVDSSOLHGZLWKPLQLPXPFRYHUDJH

Outer Jacket : ([WUXGHGEODFN39&-DFNHWVKDOOEHIODPHUHWDUGDQWDVSHU,(&-3-


2LODQGVXQ-OLJKWUHVLVWDQW
INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD
INDIVIDUAL &OVERALLSHIELDED.

Pairs
Size Pairs Strands X Insulation Nominal Inner jacketArmor wire Armor wire Outer jacket Outer jacket Approx
diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

1.0  [ 3 0.40 1.5 11.7     

3 [ 0.40 1.5   14.9   

4 [ 0.40 1.5 13.5     700.47

 [ 0.40 1.5 15.9  19.1   

 [ 0.40       

10 [ 0.40       1379

 [ 0.40     1  

Pairs Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
Size
diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/k m)
mm mm

 [ 0.40 1.5      


1.5

3 [ 0.40 1.5 13.5     

4 [ 0.40 1.5 14.7     

 [ 0.40       

 [ 0.40       1374.

10 [ 0.40      30.1 

 [ 0.40      31.4 


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED.
Pairs
Size Pairs Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

  [ 0.40 1.5      

3 [ 0.40 1.5 15.1     

4 [ 0.40  17.1     1137

 7 [ 0.40       1403.53

 [ 0.40      30 

10 [ 0.40      35 

 [ 0.40    31.1  35.9 

Triads
Triads Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
Size diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

1.0  [3 0.40 1.5   15.3   

3 [.43 0.40 1.5     19.7 707.50

4 [ 0.40 1.5   17.3   

 [ 0.40       

 [ 0.40       

10 [ 0.40       

 [ 0.40       


INSTRUMENTATION/PROCESS CONTROL CABLES

POWER LIMITED TRAY CABLE 300VOLTS (TYPE PLTC).


XLPE INSULATED MULTI PAIR/MULTI TRIAD INDIVIDUAL & OVERALL SHIELDED.
Triads
Size Triads Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)

 [ 0.40 1.5 14     711.49


1.5

3 [ 0.40 1.5   17.3   

4 [ 0.40       

 [ 0.40  1     

 [ 0.40       

10 [ 0.40       

 [ 0.40      35.4 

Triads
Triads Strands X Insulation Nominal Inner jacket Armor wire Armor wire Outer jacket Outer jacket Approx
Size diameterX mm thickness inner Jacket OD dia(mm) OD mm thickness mm OD (approx.) Weight
(mm²) mm thickness (approx.) mm (kg/km)
mm mm

     


  [ 0.40 1.5

3 [ 0.40       

4 [ 0.40       

 [ 0.40       

 [ 0.40      34.5 

10 [ 0.40    33.1  37.9 

 [ 0.40  30.1  34.1  3 


OUR PRODUCTS
O

Wires
U R P R O D U C T S

Riyadh Cables manufactures wires, cords and wiring cables rated


300/300 V, 300/500 V, 600 V and 450/750 V to be used in the supply
of electric power, lighting and internal wiring for residences and
offices, and other similar environments of a non-industrial nature as
specified in IEC 60227, BS 6004,UL 83 and BS EN 50525-3-41

Low Voltage Lead Sheathed


Low Voltage Lead Sheathed Cables are used mainly in the
utilities and petrochemical industries owing to the lead sheathing’s
resistance to sulfides, water, oil and any corrosive chemicals
found in the ground water

Medium Voltage Cables


Medium Voltage Cables support a voltage range between 6 kV
and 36 kV, making them ideal for use in infrastructure, including
the distribution and transmission of power

High Voltage & Extra High Voltage Cables


High voltage power cables (HV): Up to 380 kV, ideal for
transmission systems. At Riyadh Cables, all XLPE insulations
of our High and Extra High Voltage Cables are done pursuant to
standards outlined by IEC 60840 and IEC 62067

Overhead Lines
We produce a range of Overhead Lines, all of which are
manufactured as per the standards outlined in IEC, BS, BS EN
and ASTM specifications, as applicable. Overhead conductors
for use up to 500 kV

Fire Redundant Cables


Fire Survival Cable
¿UHUHVLVtant, redundant and low
smoke Halogen Free Cables)

Control Cables
Control Cables are the cables of choice for control circuits. At
Riyadh Cables, we offer a range of Control Cables, with XLPE
or PVC insulation, with the option of armour and/or screening
OUR PRODUCTS
O U

Copper Telephone Cables


R P R O D U C T S

We produce an extensive range of telephone cables, up to


3,600 pairs, in accordance with specifications supplied by Saudi
Telecom, as well as numerous international standards bodies

Fiber Optic Cables


At Riyadh Cables, we produce Loose Tube Type Cables and Tight
Buffer Types Cables for use as fiber optic cables for outdoor and
indoor use respectively

Copper Rods
We produce high purity copper rods of 8 mm diameter. These
copper rods are used in producing conductors for all types of
cables and metallic screens

Aluminium Rods
We produce high purity aluminium rods of 9.5 mm diameter.
These aluminium rods are used in producing conductors for
power cables and overhead line conductors and armouring

PVC Granules
We produce the PVC grades that are required for insulation and
sheathing material in cables. Our PVC Granules are produced to
the best quality specifications using state-of-the-art machines and
the most advanced automatic mixing technology

LV XLPE compounds
We produce LV XLPE material, which is used as insulation in
low voltage cables. LV XLPE compounds are produced to the
very best quality specifications and highest purity levels using
state-of-the-art machines and the most advanced automatic
mixing technology

Wooden & Steel Drums


One of the most advanced plants for manufacturing different
sizes of wooden and steel drums used in the cables industry.
The drums are manufactured on high-speed production lines to
the highest quality, with the lowest possible costs

You might also like