H7E - Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Self-powered Time Counter

H7ET
• Seven digits, time range 0 to 3999d23.9h.

Counters
• Dual time range: 999999.9 ←→ 3999d23.9h or
999h59m59s ←→ 9999h59.9m

Model Number Structure


■ Model Number Legend
H7ET - N -
1 2 3 4

1. Count Input 3. Case Color


None: No-voltage input None: Light gray
V: PNP/NPN universal DC voltage input B: Black
FV: AC/DC multi-voltage input 4. Display
2. Time Range None: 7-segment LCD without backlight
None: 999999.9h/3999d23.9h H: 7-segment LCD with backlight
1: 999h59m59s/9999h59.9m

Ordering Information
■ Time Counters
Timer input Display Time range
999999.9h ←→ 3999d23.9h 999h59min59s ←→ 9999h59.9min
(switchable) (switchable)
Light-gray body Black body Light-gray body Black body
PNP/NPN universal DC volt- 7-segment LCD with back- H7ET-NV-H H7ET-NV-BH H7ET-NV1-H H7ET-NV1-BH
age input light
7-segment LCD H7ET-NV H7ET-NV-B H7ET-NV1 H7ET-NV1-B
AC/DC multi-voltage input 7-segment LCD H7ET-NFV H7ET-NFV-B H7ET-NFV1 H7ET-NFV1-B
No-voltage input 7-segment LCD H7ET-N H7ET-N-B H7ET-N1 H7ET-N1-B

■ Accessories (Order Separately)


Lithium Battery Y92S-36
Wire-wrap Terminal (set of two terminals) Y92S-37
Compact Flush Mounting Bracket (See note.) Y92F-35
Flush Mounting Adapter 26 mm × 45.3 mm Y92F-75
27.5 mm × 52.5 mm Y92F-76
24.8 mm × 48.8 mm Y92F-77B
Note: The New H7E models are supplied with a Y92F-34 Mounting Bracket.

Self-powered Time Counter H7ET C-17


Specifications
■ General
Item H7ET-NV-@ H7ET-NFV-@ H7ET-N-@ H7ET-NV1-@ H7ET-NFV1-@ H7ET-N1-@
H7ET-NV-@H H7ET-NV1-@H
Operating mode Accumulating
Mounting method Flush mounting
External connections Screw terminals
Reset External/Manual reset
Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1)
Number of digits 7
Time range 0.0h to 999999.9h ←→ 0.0h to 3999d23.9h 0s to 999h59min59s ←→ 0.0min to 9999h59.9min
(switchable with switch) (switchable with switch)
Timer input PNP/NPN univer- AC/DC multi-volt- No-voltage input PNP/NPN univer- AC/DC multi-volt- No-voltage input
sal DC voltage in- age input sal DC voltage in- age input
put put
Case color Light gray or black (-B models)
Attachment Waterproof packing, flush mounting bracket, time unit labels (see note 2)
Approved standard UL863, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III)
Conforms to VDE0106/P100

Note: 1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
2. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included.

■ Ratings
Item H7ET-NV@-@ H7ET-NFV@-@ H7ET-N@-@
H7ET-NV@-@H
Supply voltage Backlight model: 24 VDC (0.3 W max.) Not required (powered by built-in battery)
(for backlight)
No-backlight model: Not required (pow-
ered by built-in battery)
Timer input High (logic) level: 4.5 to 30 VDC High (logic) level: 24 to 240 VAC/VDC, No voltage input
Low (logic) level: 0 to 2 VDC 50/60 Hz Maximum short-circuit impedance:
(Input impedance: Approx. 4.7 kΩ) Low (logic) level: 0 to 2.4 VAC/VDC, 50/ 10 kΩ max.
60 Hz Short-circuit residual voltage: 0.5 V max.
Reset input No voltage input Minimum open impedance: 750 kΩ min.
Maximum short-circuit impedance:
10 kΩ max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 kΩ min.
Minimum pulse 1s
width
Reset system External reset and manual reset: Minimum signal width of 20 ms
Terminal screw 0.98 N·m max.
tightening torque
Ambient tempera- Operating: -10°C to 55°C (with no condensation or icing)
ture Storage: -25°C to 65°C (with no condensation or icing)
Ambient humidity Operating: 25% to 85%

C-18 Self-powered Time Counter H7ET


■ Characteristics
Item H7ET-NV@-@ H7ET-NFV@-@ H7ET-N@-@
H7ET-NV@-H@
Time accuracy ±100 ppm (25°C)
Insulation resistance 100 MΩ min. (at 500 VDC) between 100 MΩ min. (at 500 VDC) between 100 MΩ min. (at 500 VDC) between
current-carrying metal parts and ex- current-carrying metal parts and ex- current-carrying metal parts and ex-
posed non-current-carrying metal posed non-current-carrying metal posed non-current-carrying metal
parts, and between the backlight pow- parts and between timer input termi- parts
er supply and timer input terminals/re- nals and reset terminals

Counters
set terminals for backlight models
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between 3,700 VAC, 50/60 Hz for 1 min between 1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex- timer input terminals and exposed non- current-carrying metal parts and ex-
posed non-current-carrying metal current-carrying metal parts posed non-current-carrying metal
parts and between the backlight power 2,200 VAC, 50/60 Hz for 1 min between parts
supply and timer input terminals/reset reset terminals and exposed non-cur-
terminals for backlight models rent-carrying metal parts and between
timer input terminals and reset termi-
nals
Impulse withstand 4.5 kV between current-carrying termi- 4.5 kV between current-carrying termi- 4.5 kV between current-carrying termi-
voltage nal and exposed non-current-carrying nal and exposed non-current-carrying nal and exposed non-current-carrying
metal parts metal parts metal parts
3 kV between timer input terminals and
reset terminals
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±600 V (Between timer input terminals/ ±1.5 kV (Between timer input termi- ±500 V (Between timer input terminals/
Between reset terminals) nals) Between reset terminals)
±480 V (Between the backlight power ±500 V (Between reset terminals)
supply terminals for backlight models)
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions
Destruction: 300 m/s2 3 times each in 6 directions
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class B
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power line (level 3)
2 kV I/O signal line (level 4)
Degree of protection Front panel: IP66, NEMA4 with waterproof packing
Terminal block: IP20
Weight (see note) No-backlight model: Approx. 60 g Approx. 60 g Approx. 60 g
Backlight model: Approx. 65 g

Note: Weight includes waterproof packing and flush mounting bracket.

■ Reference Value
Item Value Note
Battery life 10 years min. with continuous input at The battery life is calculated according to the conditions in the left column and
25°C (lithium battery) therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.

Self-powered Time Counter H7ET C-19


Connections
■ Terminal Arrangement
Bottom view: View of the Time Counter rotated horizontally 180°

Backlight Model No-backlight Model

Backlight
24 VDC

Timer Reset
Timer Reset input input
input input

■ Connections
H7ET Time Counter
PNP/NPN Universal DC Voltage Input Model With Backlight
1. Contact Input (Input by a Relay or Switch Contact) 2. Solid-state Input
Open collector of a Open collector of a
Relay Relay PNP transistor Backlight PNP transistor
Backlight 24 VDC*
24 VDC
Input Reset
Input Reset

or Switch or Switch

or Open collector of an or Open collector of an


NPN transistor NPN transistor

Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are func-
tionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector ≥ 50 V
Leakage current < 1 µA
Note: *Recommended power supply; eg. OMRON S8VS

C-20 Self-powered Time Counter H7ET


PNP/NPN Universal DC Voltage Input Model Without Backlight No-voltage Input Model
1. Contact Input (Input by a Relay or Switch Contact) 1. Contact Input (Input by a Relay or Switch Contact)
Relay Relay
Relay Relay
Input Reset

Input Reset

Terminals 2 and 4 are

Counters
internally connected.
or Switch or Switch
or Switch or Switch

Note: Use Relays and Switches that have high contact relia-
2. Solid-state Input bility because the current flowing from terminals 1 or
Open collector of a Open collector of a 3 is as small as approx. 10 µA. It is recommended
PNP transistor PNP transistor
that OMRON's G3TA-IA/ID be used as the SSR.

Input Reset 2. Solid-state Input


(Open Collector Input of an NPN Transistor)

Open collector of an Open collector of an


NPN transistor Input NPN transistor
Reset

Terminals 2 and 4 are


or Open collector of an or Open collector of an internally connected.
NPN transistor NPN transistor or Switch

Note: 1. Residual voltage in the output section of Proximity


Sensors or Photoelectric Sensors becomes less
than 0.5 V because the current flowing from termi-
nals 1 or 3 is as small as approx. 10 µA, thus allow-
ing easy connection.
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are 2. Select input transistors according to the following:
functionally isolated. Dielectric strength of the collector ≥ 50 V
2. Select input transistors according to the following: Leakage current < 1 µA
Dielectric strength of the collector ≥ 50 V
Leakage current < 1 µA
AC/DC Multi-voltage Input Model
Relay

Relay
Input Reset

or Switch or Switch

or Open collector of
an NPN transistor

Self-powered Time Counter H7ET C-21


Operation
■ Operating Modes
H7ET Time Counter
Incrementing Operation
(Up)
Reset

Timer input

Internal clock
timer value
Full-scale
(Full-scale
−0.1 (1))

Timer display values

Nomenclature
Front view

H7ET
Reset Key
Reset the count value. Not operable
under key-protect.

Time-range switch Key-protect Switch


If the time-range setting is The Reset Key is not operable while the
changed, the present key-protect switch is set to ON.
value will not be held and
so press the Reset Key on Setting
the front panel. (see note) Key-protect
Front panel
Setting Time range Bottom view Concave OFF
side
(see note) (default setting)
H7ET-N@@-@@ H7ET-N@@1-@@
Front panel
Concave
0.0h to 3999d23.9h 0s to 999h59min59s
side
(default setting) Concave
side
ON
Terminal block

Concave 0.0h to 999999.9h


side (default setting) 0.0min to 9999h59.9min
Terminal block

Note: Perform switch setting before mounting to a control panel.

C-22 Self-powered Time Counter H7ET


Dimensions
Note: All units are in millimeters unless otherwise indicated.

H7ET-N

Counters
Panel Cutout
Separate mounting

40 min.
45+0.5
0

Dimensions with Flush Mounting Bracket 22.2+0.5


0

Dense mounting
+1.0
(48 Units − 2.5) 0

22.2+0.5
0

Waterproofing is not possible


for dense mounting
• When mounting, insert the Counter into
the cutout, insert the adapter from the
back and push in the Counter while
making the gap between the front panel
and the cutout panel as small as
possible. Use screws to secure the
Counter. If waterproofing is desired,
insert the waterproof packing.
• When several Counters are installed,
ensure that the ambient temperature
will not exceed specifications.
• The appropriate thickness of the panel
is 1 to 5 mm.
Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details.