H7E - Datasheet
H7E - Datasheet
H7E - Datasheet
H7ET
• Seven digits, time range 0 to 3999d23.9h.
Counters
• Dual time range: 999999.9 ←→ 3999d23.9h or
999h59m59s ←→ 9999h59.9m
Ordering Information
■ Time Counters
Timer input Display Time range
999999.9h ←→ 3999d23.9h 999h59min59s ←→ 9999h59.9min
(switchable) (switchable)
Light-gray body Black body Light-gray body Black body
PNP/NPN universal DC volt- 7-segment LCD with back- H7ET-NV-H H7ET-NV-BH H7ET-NV1-H H7ET-NV1-BH
age input light
7-segment LCD H7ET-NV H7ET-NV-B H7ET-NV1 H7ET-NV1-B
AC/DC multi-voltage input 7-segment LCD H7ET-NFV H7ET-NFV-B H7ET-NFV1 H7ET-NFV1-B
No-voltage input 7-segment LCD H7ET-N H7ET-N-B H7ET-N1 H7ET-N1-B
Note: 1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
2. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included.
■ Ratings
Item H7ET-NV@-@ H7ET-NFV@-@ H7ET-N@-@
H7ET-NV@-@H
Supply voltage Backlight model: 24 VDC (0.3 W max.) Not required (powered by built-in battery)
(for backlight)
No-backlight model: Not required (pow-
ered by built-in battery)
Timer input High (logic) level: 4.5 to 30 VDC High (logic) level: 24 to 240 VAC/VDC, No voltage input
Low (logic) level: 0 to 2 VDC 50/60 Hz Maximum short-circuit impedance:
(Input impedance: Approx. 4.7 kΩ) Low (logic) level: 0 to 2.4 VAC/VDC, 50/ 10 kΩ max.
60 Hz Short-circuit residual voltage: 0.5 V max.
Reset input No voltage input Minimum open impedance: 750 kΩ min.
Maximum short-circuit impedance:
10 kΩ max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 kΩ min.
Minimum pulse 1s
width
Reset system External reset and manual reset: Minimum signal width of 20 ms
Terminal screw 0.98 N·m max.
tightening torque
Ambient tempera- Operating: -10°C to 55°C (with no condensation or icing)
ture Storage: -25°C to 65°C (with no condensation or icing)
Ambient humidity Operating: 25% to 85%
Counters
set terminals for backlight models
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between 3,700 VAC, 50/60 Hz for 1 min between 1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex- timer input terminals and exposed non- current-carrying metal parts and ex-
posed non-current-carrying metal current-carrying metal parts posed non-current-carrying metal
parts and between the backlight power 2,200 VAC, 50/60 Hz for 1 min between parts
supply and timer input terminals/reset reset terminals and exposed non-cur-
terminals for backlight models rent-carrying metal parts and between
timer input terminals and reset termi-
nals
Impulse withstand 4.5 kV between current-carrying termi- 4.5 kV between current-carrying termi- 4.5 kV between current-carrying termi-
voltage nal and exposed non-current-carrying nal and exposed non-current-carrying nal and exposed non-current-carrying
metal parts metal parts metal parts
3 kV between timer input terminals and
reset terminals
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±600 V (Between timer input terminals/ ±1.5 kV (Between timer input termi- ±500 V (Between timer input terminals/
Between reset terminals) nals) Between reset terminals)
±480 V (Between the backlight power ±500 V (Between reset terminals)
supply terminals for backlight models)
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction: 200 m/s2 3 times each in 6 directions
Destruction: 300 m/s2 3 times each in 6 directions
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class B
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power line (level 3)
2 kV I/O signal line (level 4)
Degree of protection Front panel: IP66, NEMA4 with waterproof packing
Terminal block: IP20
Weight (see note) No-backlight model: Approx. 60 g Approx. 60 g Approx. 60 g
Backlight model: Approx. 65 g
■ Reference Value
Item Value Note
Battery life 10 years min. with continuous input at The battery life is calculated according to the conditions in the left column and
25°C (lithium battery) therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
Backlight
24 VDC
Timer Reset
Timer Reset input input
input input
■ Connections
H7ET Time Counter
PNP/NPN Universal DC Voltage Input Model With Backlight
1. Contact Input (Input by a Relay or Switch Contact) 2. Solid-state Input
Open collector of a Open collector of a
Relay Relay PNP transistor Backlight PNP transistor
Backlight 24 VDC*
24 VDC
Input Reset
Input Reset
or Switch or Switch
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are func-
tionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector ≥ 50 V
Leakage current < 1 µA
Note: *Recommended power supply; eg. OMRON S8VS
Input Reset
Counters
internally connected.
or Switch or Switch
or Switch or Switch
Note: Use Relays and Switches that have high contact relia-
2. Solid-state Input bility because the current flowing from terminals 1 or
Open collector of a Open collector of a 3 is as small as approx. 10 µA. It is recommended
PNP transistor PNP transistor
that OMRON's G3TA-IA/ID be used as the SSR.
Relay
Input Reset
or Switch or Switch
or Open collector of
an NPN transistor
Timer input
Internal clock
timer value
Full-scale
(Full-scale
−0.1 (1))
Nomenclature
Front view
H7ET
Reset Key
Reset the count value. Not operable
under key-protect.
H7ET-N
Counters
Panel Cutout
Separate mounting
40 min.
45+0.5
0
Dense mounting
+1.0
(48 Units − 2.5) 0
22.2+0.5
0