A-1] ADVANTAGES :
1. Greater measurement accuracy.
2. Durability & reliability.
3. Easy assembly & functioning.
4. Non contact measurement.
5. Less operator fatigue.
6. Most economical Airgauge in the market.
7. High accuracy 0.1µm.
8. Automatic cleaning of measured surfaces.
9. Measurement in harsh workshop conditions.
10. RS 232 interface software for data exchange.
11. Airgauge type / LVDT type / Encoder type.
12. 16*2 LCD display and tricolor 7 segment Displays.
13. Compact in size.
14. Simple operation with menu Guidance.
A-2] APPLICATIONS :
The IAPCOMP digital can be used for the measurement of different jobs (such as ID, OD,
ovality, job center measurement) using air pressure.
A-3] FEATURES :
CALIBRATION BY MASTER 1
CALIBRATION CALIBRATION BY OVALITY MASTER
& MASTER 2 I.E. STATIC
THIS KEY ONLY EFFECT
WHEN MEASUREMENT TYPE THIS KEY ONLY EFFECT WHEN
IS SET TO “AB-IN” IN MEASUREMENT TYPE IS SET TO
PARAMETER SETTING. IF “AB-IN” IN PARAMETER SETTING.IF
ABSOLUTE / LED IS ON, IT MEANS “ABS” LED IS ON, IT MEANS “ABS”
INCREMENT MEASUREMENT TYPE IS MEASUREMENT TYPE IS
SELECTED.ON OTHER HAND SELECTED.ON OTHER HAND IF LED
IF LED IS OFF IT MEANS IS OFF IT MEANS “INC”
“INC” MEASUREMENT TYPE MEASUREMENT TYPE IS SELECTED.
IS SELECTED.
THIS KEY ONLY EFFECT
WHEN MEASUREMENT TYPE THIS KEY ONLY EFFECT WHEN
IS SET TO “IN-MM” IN MEASUREMENT TYPE IS SET TO
PARAMETER SETTING. IF “IN-MM” IN PARAMETER SETTING.IF
LED IS ON IT MEANS “INCH” LED IS ON IT MEANS “INCH”
INCH/MM
MEASUREMENT UNIT IS MEASUREMENT UNIT IS
SELECTED.ON OTHER HAND SELECTED.ON OTHER HAND IF LED
IF LED IS OFF IT MEANS IS OFF IT MEANS “MM”
“MM” MEASUREMENT UNIT MEASUREMENT UNIT IS SELECTED.
IS SELECTED.
UP MEMORY MANAGEMENT
MEMORY MANAGEMENT
C] SPECIFICATION :
D] FRONT PANNEL :
F] POWER ON SETTINGS :
After that it will lead to Calibration screen. In Calibration screen it will ask you to select
channel 1 (press key “CH1” ) or channel 2 (press key “CH2” ) otherwise skip
After successful Calibration OR Exiting Calibration mode Airgauge lead to Home screen which
run default in Airguage.
Home screen shows characteristics name (like C1 and C2 ) , It’s measuring UNIT (like mm or
inch) and the channel selected for respective characteristics(like A, B, A+B, A-B ).
There are two rows of 8 7-segment in each rows . as shown bellow for Channel 1 and
Channel 2.
This mode is used to configure different parameters for each job measurement (25 programs
each for one job) to user’s need and requirement. This is a special mode and is generally
intended to use by person adverse to AIRGAUGE and its manual.
Airgauge will enter into this mode after pressing “PROG” key when Airgauge
showing Home screen. After it will show program menu screen. Here you can access different
program menus available under program menu. Use “UP” key and “DOWN”
key from accessing different options.
Following are options available under program menu:
Table no:G-1:program menu option settings.
Program
ACTION PERFORMED
menu
Total 25 programs can be set for
1]Prog no both channel with different
Parameters for different jobs.
It will give us access to different
parameter settings for
2]Char-1
characteristic 1 of program no set in
above setting(Prog no).
It will give us access to different
parameter settings for
3]Char-2
characteristic 2 of program no set in
above setting(Prog no).
It will save status number for every
4]Status measured job. assign status for
each status number.
10]Relay_ON_
Relay ON timing
Time
11]Operator
Operator number setting
Number
12] Machine
Machine number setting
Number
13] Custom
Custom number setting
Number
14] Tool
Tool number setting
Number
18] IP
IP Address Setting
Address
20] Control
Control Limit Setting
Limit
21] Fanuc
Fanuc Delay Setting
Delay
In “char-1” Program menu Airgauge ask for password entry So Here Sequentially press key as
mentioned ahead “F1”, “F2”, “F3”, “CAL” AND “ENT”.
Then for accessing different sub option within the parameter menu use “UP” OR
decrementing value on segment.When you are at 7th digit position and press “LEFT”
key for moving 8th position it is blank.
This is Digit Sign position. Press “UP” or “DOWN” key for minus sign (positive
sign is not shown on display) When there is no any sign present then it will indicate positive
*Note : Total 25 programs you can set for 25 no. of different jobs.
Changes to these menus are applicable for only that job you have
selected. For every new job you have to set new parameters in a new
program.
Fanuc interface:
Fanuc Interface is used for communication of Airgauge with Fanuc
controller for offset adjustment. Port Selects Fanuc to send data to the Serial
Port.
When asked the main offset value is send to the Fanuc controller as
per the protocol, Baud rate- 9600, 8 bit, Stop bit=1, parity=none.
Offset value is calculated by taking average of 20 values
(settable Max 20).
If the average of 20 values is greater than control limits UCL or LCL
for consecutive 7 times (settable Max20) then the new offset is calculated &
added to the main offset value. This main offset is then saved in memory &
send to the Fanuc controller when asked to send. If offset value calculated is
more than wear limit then change tool alarm is showed & this offset value is
not added in the main offset value. Average count & consecutive count is
cleared.
If values for averaging taken is less than 20, then this average values
are not taken for checking with control limit.
Reset function is used to clear main offset value, Average count,
consecutive count, Also main offset value=0 is saved in memory.
After calibration or preset or at power ON, Reset, or change in
program, Average count=0, Consecutive Count=0, Average=0.
Array is moving average array Ie. Last In First Out.
Wear limit:- If the Offset value is greater than the wear limit then show
the “Change Tool “ alarm & don’t take the offset value in the calculation.
For setting of Max Average Count, Max Consecutive count, Wear
limit & Reset press key & then key. Then select respective function
& by Key. Press key to modify. Press key to quit.
For selection of Fanuc Function for serial port press key. Then
Press key till ‘port’ is not coming. Then press key. Now press
Key to select the ‘Fanuc’ Function.
15.1. Reset:- Fanuc Offset resets to 0.0. Reset function is used to clear main
offset value, Average count, consecutive count, Also main offset value=0 is
saved in memory.
Press key to toggle the mode
Press key to enter in reset then it will ask 'YES' to confirm. Press
Press key to enter in the mode & will display the count,
When you enter in the mode last digit starts blinking, & you can set the count
but it will accept the count less than 20.
To change the count, Press to change the digit place & press to
change the digit value to set the count.
Press key to enter in the mode, & will display the count,
When you enter in the mode last digit starts blinking, & you can set the count
but it will accept the count less than 20.
To change the count, Press to change the digit place & press
to change the digit value to set the count.
Press key will display the count,& will display the count,
To set the Wear Limit Value, Press to change the digit place & press
to change the digit value to set the count.
16. Fanuc 2:
To set the Air save time, Press to change the digit place & press to
change the digit value to set the count.
18. IP Address:
If no any device is connected then you will display Command error, “Restart
Device” window as shown above.
Press key to quit. & will start Rebooting.
IP Address setting:-
1. Local IP
2. Subnet mask.
3. Gateway
4. Remote Host IP
1. Local IP:-
When you enter in Local IP mode you will get Initial Local IP
“000.000.000.000” will show old IP.
To set the Local IP, Press to change the digit place & press to change
the digit value to set the IP.
Press key to save the changes & to exit.
2. Subnet Mask:-
To set the Subnet Mask, Press to change the digit place & press
to change the digit value to set the IP.
Press key to save the changes & to exit.
3. Gateway:-
To set the Gateway, Press to change the digit place & press
to change the digit value to set the IP.
Press key to save the changes & to exit.
In Low Air Cut off, you will get "4.0","3.8","3.6","3.4","3.2" Low Air
cut off selections. Press key to toggle & Press key to select.
When Fanuc sends “LS” Command to Airguage then after this delay time data
will be send to Fanuc.
1 Count = 0.1 sec
This mode is a useful mode and is required when the system malfunctions and does
not function correctly. Use of this function is cautioned as this will erase all the settings and
corrections applied.
To factory set Airguage UNIT directly switch off the Airguage and keep pressing “CAL”
key & then Power ON the Airgauge.
This will erase correction factor, probe center, all the data in memory, ovality measured &
center offset calculated.
This process will take some time; wait up to Program No. 25 After that Airgauge will enter
in calibration mode, if you want to enter in Home Position, then press “ESC” key.
I] CALLIBRATION MODE :
At power ON, Airgauge will enter into calibration mode or you can press “CAL” key
to enter in this mode. After Airgauge entered in calibration mode, You first select Channel No.,
( press “CH1” key for channel-1 or press “CH2” key for channel-2). Display shows
Insert Higher Master message, after inserting press “ENT” key. Then display shows
Insert Lower Master message, then press “ENT” key. Then displays Done & goes
back to calibration window.
Press “UP” key to enter into memory management Mode. Here you can see the stored
values in the memory. You can send the value to the RS232 (Serial port). You can delete the
stored jobs.
Table no: M-1: Memory management function menu.
Memory ACTION PERFORMED
managem
ent menu
It displays information about Job Measurement in
memory.
e.g: if we measure a job with Program No.1 &
Ch-1, then information shows its Memory No.,
View Program & Ch No., its Status as Accept/ reject/
ENTER NO ACTION
UP MEMORY MANAGEMENT
DOWN NO ACTION
SP1 NO ACTION
SP2 NO ACTION
2) Above the Higher master : 7-segment LCD of related Channel becomes Red (Reject
mode).
3) Between higher and lower master : 7-segment LCD of related Channel becomes Green
(Accept).
2) Above the Higher master : 7-segment LCD of related Channel becomes Orange (Rework
mode).
3) Between higher and lower master : 7-segment LCD of related Channel becomes Green
(Accept).
AUTOSENCE MODE :
If Auto sense(Auto storing) mode is ON and if the current value does not change for 2 seconds
then this value will be automatically stored in the memory, also data will be sent on RS232
(serial port) for further PC based SPC analysis.
The job will be compared with the tolerance setting and according to that accept, reject or
rework count will be incremented. Also this status will be stored in the memory.
Also if “F1” key or foot switch is pressed then also the current value is stored in the
memory with accept, reject or rework status and count will be sent on RS232 (serial port).
ENTER NO ACTION
UP MEMORY MANAGEMENT
DOWN NO ACTION
SP1 NO ACTION
SP2 NO ACTION
B) MAX :
• Start measurement, after inserting plug in job current reading is shown.
(See Parameter No. 20 to 28)
• If reading is in the auto-sense range then after auto-sense time the MAX value will
reset to current job value automatically.
• Then rotate the job to check MAX value. MAX reading is calculated automatically &
displayed.
C) MIN :
• Start measurement, after inserting plug in job current reading is shown.
(See Parameter No. 20 to 28)
• If reading is in the auto-sense range then after auto-sense time the MIN value will
reset to current job value automatically.
• Then rotate the job to check MIN value. MIN reading is calculated automatically &
displayed.
D) AVG :
• Start measurement, after inserting plug in job current reading is shown.
(See Parameter No. 20 to 28)
• If reading is in the auto-sense range then after auto-sense time the AVG value will
reset to current job value automatically.
• Then rotate the job to check AVG. Then MAX, MIN, AVG reading is calculated
automatically & AVG value is displayed.
E) TIR_SP :
• In this mode you can check both Ovality of the job as well as job size.
• Start measurement, after inserting plug in job current reading is shown.
(See Parameter No. 20 to 28)
• If reading is in the auto-sense range then after auto-sense time the TIR value will
reset to current job value automatically.
• Then rotate the job to check O
• SP mode will check for value entered, if this value is greater than size tolerance (i.e.
HL & LL) then it will be in reject mode.
• SP mode will check for Ovality: If Ovality is greater than Ovality Tolerance, then also it
will enter in Reject mode.
• If job is removed & again inserted & if its value is in the settable range, then Ovality
measurement will reset.
• Checking of value is continuous in SP mode.
sensor value is shown in percentage (i.e. Air Pressure value in percentage). This is used to
adjust the probe.
Press “LEFT” key, It will lead to selection of channel 1 or channel 2.
For selecting channel-1 press “CH-1” key or press “CH-2” for channel-2.
EXAMPLE :
OR
Press “CH1” or “CH2” key to activate preset mode (i.e offset of center master) for
channel-1 or channel-2 respectively. Here it will show you current center master value for
respective channel. In this mode you can enter center master value by pressing “LEFT”
or “UP” key. Then center offset value will be calculated internally by the software using
bellow formula
Otherwise press “F3” or “ENT” key to calculate center master offset value using
above formula just difference is that here it will take currently stored Center master value and
exit this mode.
Connect LVDT probe to the Airguage & probe stand as shown in below fig.
For length measurement with LVDT do the following settings in Airguage.
1) Set the Nominal value (i.e. Diameter setting ) Parameter No.1:- e.g. 20.000
2) Set the higher tolerance limit (i.e. HL) Parameter No.2:- e.g. 20.0100
3) Set the lower tolerance limit (i.e. LL) Parameter No.3:- e.g. 19.9900
4) Set the higher master (i.e. HM) Parameter No.4:- e.g. 1.0000
5) Set the lower master (i.e. LM) Parameter No.5:- e.g. 0.0000
Above HM & LM settings for 1mm measuring range, set these parameters as per required
range.
Select SIM mode, for calibration by only one master i.e. HM (Higher Master).
[You can select NOR mode, for calibration by two masters i.e. HM & LM (Higher Master &
Lower Master).]
Segment display shows Actual probe value (when probe not pressed).
3) Place the Higher Master of 1.000 value & press key to do the calibration.
M] WIFI INTERFACE :
Press key and go to “WiFi testing” menu present in program setting menu
Press key then display will show you following message as “WiFi testing”,
then configure the WiFi module and after configuration press key for escaping from
“WiFi testing mode”.
Press key .Here you can change Status Number just by pressing key, changed
no. will be displayed on the LCD. The Status No. will be automatically saved.
This software can be used for saving different jobs data (readings) from Airgauge, through
serial interfacing.
Open Serial interface software (from CD) (i.e. SPC v3.5), Install the software in PC.
Open the SPC Setup software
On Airgauge, if key is pressed then data will be sent to the Serial Software or if
foot-switch is pressed then last saved memory data will be automatically sent to the serial port.
If you want to store data click on New from file menu & press Add button. You can see added
values in List as below:
When values are stored in the list you can see the Line Graph & Histogram.
Line Graph:-
Histogram:-
Setup mode:-
1) Data Setup: Here you can select COM port, fractional digits & multiplier for entered
value.
3) Statistical setup: LSL (Lower Specific Limit), USL (Upper Specific Limit) & No. of
groups can be changed.
4) Print setup: Company Name, Part Name, Part no., Operation Desc, Operator Name,
Machine & Gauge Name are settable.
5) Language selection: You can change English to German & German to English.
7) Unit: Unit of measurement can be toggled between INCH (i.e. Imperial & MM (i.e.
Metric).
8) Select Range: Here you can select all data or can select specific range.
O] CONNECTOR DETAILS :
Within this period, we will repair it without charge for parts and labor. Warranty does not cover
transportation cost, nor does it cover a product subjected to misuse or accidental damage, nor
does it support damages due to lightning or very high power transients.
This warranty is limited to IAP COMP digital manufactured by us. The warranty on
scale/sensor is subjected to the warranty given by its respective manufacturer.
* TEST CERTIFICATE *
MODEL:
SR. NO.:
DATE:
USER NOTES
Specifications and the design are subject to possible modifications
without notice due to constant improvements.
EMAIL : [email protected]