Slab Design-A
Slab Design-A
GROUND FLOOR
INPUT DATA
𝐿𝑜𝑛𝑔𝑒𝑟 𝑠𝑝𝑎𝑛
One way slab → >2
𝑆ℎ𝑜𝑟𝑡𝑒𝑟 𝑠𝑝𝑎𝑛
𝐿𝑜𝑛𝑔𝑒𝑟 𝑠𝑝𝑎𝑛
Two-way slab → <2
𝑆ℎ𝑜𝑟𝑡𝑒𝑟 𝑠𝑝𝑎𝑛
Live Load → For all other residential areas except stairs and balconies = L.L = 40 psf
(ASCE)
fy = 60,000 psi
= 0.9
BEDROOM ─ 1, BEDROOM ─ 2
Longer span = 18.75 ft
Shorter span = 12 ft
Slab Thickness
′
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(18.75′ + 12′ )
ℎ= = × 12 = 4.1"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
1
Factored Live Load
WL = 1.6 x 40 = 64 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 12′
= = 0.64
𝑙𝑏 18.75′
Case
One long and one short side continuous → Case 4
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 7614.844
3
𝑀𝑏. 𝑛𝑒𝑔 = 2538.2813 𝑙𝑏. 𝑖𝑛
Reinforcement
0.85𝑓𝑐 ′ 87000
𝜌𝑏 = 𝛽( )
𝑓𝑦 87000 + 𝑓𝑦
𝜌𝑚𝑎𝑥 = 0.75𝜌𝑏
𝜌𝑚𝑎𝑥 = 0.021
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
3
Short Direction
1 2𝑚𝑅𝑛
𝜌= (1 − √1 − )
𝑚 𝑓𝑦
1 2 × 17.64 × 94.433
𝜌= (1 − √1 − )
17.64 60,000
𝜌 = 0.001596
𝐴𝑠 = 𝜌𝑏𝑑
𝐴𝑠 = 0.0018 × 12 × 4.25
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
4
NEGATIVE REINFORCEMENT – CONTINUOUS END
𝑀𝑛 = 32123.52 𝑙𝑏. 𝑖𝑛
𝑅𝑛 = 148.20 𝑝𝑠𝑖
𝜌 = 0.002526
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝜌𝑢𝑠𝑒𝑑 = 0.002526
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑀𝑛 = 6822.78 𝑙𝑏. 𝑖𝑛
𝑅𝑛 = 31.477 𝑝𝑠𝑖
𝜌 = 0.000527
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
POSITIVE REINFORCEMENT – MID SPAN
𝑅𝑛 = 50.138 𝑝𝑠𝑖
𝜌 = 0.000842
𝜌𝑚𝑖𝑛 = 0.0018
5
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 59.88 𝑝𝑠𝑖
𝜌 = 0.001007
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 13.011 𝑝𝑠𝑖
𝜌 = 0.000217
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 12’ x 18.75’ x 195 = 43875 lb
Wa = 0.858 , Wb = 0.142
6
Load/ft on long beam
43875 × 0.858 𝑙𝑏
= = 1003.86
2 × 18.75 𝑓𝑡
FINAL OUTPUT
BATHROOM ─ 1, BATHROOM ─ 2
Longer span = 6 ft
Shorter span = 5 ft
𝐿𝑜𝑛𝑔𝑒𝑟 𝑠𝑝𝑎𝑛 6′
= = 1.2 < 2
𝑆ℎ𝑜𝑟𝑡𝑒𝑟 𝑠𝑝𝑎𝑛 5′
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(6′ + 5′ )
ℎ= = × 12 = 1.467"
180 180
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
7
d = 4.25”
Load Calculation
Dead Load
WL = 1.6 x 40 = 64 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 5′
= = 0.59 0.83
𝑙𝑏 6′
Case
One long side discontinuous → Case 8
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
8
𝑀𝑎.𝑝𝑜𝑠,𝑑𝑙 = 1186.86 𝑙𝑏. 𝑖𝑛
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 1491.869
3
𝑀𝑏. 𝑛𝑒𝑔 = 497.28 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 10.1785 𝑝𝑠𝑖
𝜌 = 0.00017
𝜌𝑚𝑖𝑛 = 0.0018
9
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 15.414 𝑝𝑠𝑖
𝜌 = 0.000257
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 3.392 𝑝𝑠𝑖
𝜌 = 0.000057
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
10
𝑅𝑛 = 9.823 𝑝𝑠𝑖
𝜌 = 0.000164
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 19 𝑝𝑠𝑖
𝜌 = 0.000318
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 2.54 𝑝𝑠𝑖
𝜌 = 0.00004
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
11
Shear Check
Total applied load = 5’ x 6’ x 195 = 5850 lb
Wa = 0.514 , Wb = 0.486
FINAL OUTPUT
KITCHEN
Longer span = 11 ft
Shorter span = 9 ft
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(11′ + 9′ )
ℎ= = × 12 = 2.67"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
12
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
WL = 1.6 x 40 = 64 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 9′
= = 0.82
𝑙𝑏 11′
Case
One long side discontinuous → Case 8
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
13
Positive moments for slab middle strips
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 4882.495
3
𝑀𝑏. 𝑛𝑒𝑔 = 1627.4984 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 33.65 𝑝𝑠𝑖
14
𝜌 = 0.000563
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 51.10 𝑝𝑠𝑖
𝜌 = 0.000858
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝜌𝑢𝑠𝑒𝑑 = 0.001906
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 11.2 𝑝𝑠𝑖
𝜌 = 0.000187
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
15
Long Direction
𝑅𝑛 = 32.148 𝑝𝑠𝑖
𝜌 = 0.000538
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 62.412 𝑝𝑠𝑖
𝜌 = 0.00105
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 8.342 𝑝𝑠𝑖
𝜌 = 0.000139
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
16
𝜌𝑢𝑠𝑒𝑑 = 𝜌𝑚𝑖𝑛 = 0.0018
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 9’ x 11’ x 195 = 19305 lb
Wa = 0.526 , Wb = 0.474
FINAL OUTPUT
BATHROOM ─ 3
Longer span = 5.25 ft
17
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(5.25′ + 4.67′)
ℎ= = × 12 = 1.32"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
WL = 1.6 x 40 = 64 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 4.67′
= = 0.89
𝑙𝑏 5.25′
Case
One long side discontinuous → Case 8
Co-efficient
From coefficient tables
18
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 1305.47
3
𝑀𝑏. 𝑛𝑒𝑔 = 435.156 𝑙𝑏. 𝑖𝑛
19
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 7.625 𝑝𝑠𝑖
𝜌 = 0.000127
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 11.56 𝑝𝑠𝑖
𝜌 = 0.000193
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 2.541 𝑝𝑠𝑖
𝜌 = 0.000042
𝜌𝑚𝑖𝑛 = 0.0018
20
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 8.595 𝑝𝑠𝑖
𝜌 = 0.000143
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 16.795 𝑝𝑠𝑖
𝜌 = 0.000281
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
21
𝑅𝑛 = 2.23 𝑝𝑠𝑖
𝜌 = 0.000037
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 4.67’ x 5.25’ x 195 = 4780.913 lb
Wa = 0.442 , Wb = 0.558
FINAL OUTPUT
22
DINING ROOM
Longer span = 9.5 ft
Shorter span = 9 ft
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(13′ + 12′)
ℎ= = × 12 = 3.33"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
WL = 1.6 x 40 = 64 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 9′
= = 0.95
𝑙𝑏 9.5′
23
Case
One long side discontinuous → Case 8
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
24
1
𝑀𝑎. 𝑛𝑒𝑔 = × 4729.752
3
𝑀𝑎. 𝑛𝑒𝑔 = 1576.584 𝑙𝑏. 𝑖𝑛
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 4850.757
3
𝑀𝑏. 𝑛𝑒𝑔 = 1616.919𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 24.24 𝑝𝑠𝑖
𝜌 = 0.000406
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 36.92 𝑝𝑠𝑖
𝜌 = 0.000619
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
25
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 8.081 𝑝𝑠𝑖
𝜌 = 0.000135
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 31.93 𝑝𝑠𝑖
𝜌 = 0.000535
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 60.62 𝑝𝑠𝑖
𝜌 = 0.00102
𝜌𝑚𝑖𝑛 = 0.0018
26
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 8.288 𝑝𝑠𝑖
𝜌 = 0.000138
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 9’ x 9.5’ x 195 = 16672.5 lb
Wa = 0.38 , Wb = 0.62
27
FINAL OUTPUT
DRAWING ROOM
Longer span = 13 ft
Shorter span = 12 ft
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(13′ + 12′)
ℎ= = × 12 = 3.33"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
WL = 1.6 x 40 = 64 psf
28
Wu =WL + WD = 64 +131 = 195 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 12′
= = 0.92
𝑙𝑏 13′
Case
One short and one long side continuous → Case 4
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
29
𝑀𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙 = 9587.573 𝑙𝑏. 𝑖𝑛
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 9587.573
3
𝑀𝑏. 𝑛𝑒𝑔 = 3195.857 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 58.104 𝑝𝑠𝑖
𝜌 = 0.000977
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 100.185 𝑝𝑠𝑖
𝜌 = 0.001695
𝜌𝑚𝑖𝑛 = 0.0018
30
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 19.36 𝑝𝑠𝑖
𝜌 = 0.000324
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 63.128 𝑝𝑠𝑖
𝜌 = 0.00106
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
31
NEGATIVE REINFORCEMENT – CONTINUOUS END
𝑅𝑛 = 85.14 𝑝𝑠𝑖
𝜌 = 0.001437
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 16.38 𝑝𝑠𝑖
𝜌 = 0.000274
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 12’ x 13’ x 195 = 30420 lb
Wa = 0.58 , Wb = 0.42
32
30420 × 0.42 𝑙𝑏
= = 532.35
2 × 12 𝑓𝑡
FINAL OUTPUT
BATHROOM ─ 4
Longer span = 6 ft
Shorter span = 5 ft
𝐿𝑜𝑛𝑔𝑒𝑟 𝑠𝑝𝑎𝑛 6′
= = 1.2 < 2
𝑆ℎ𝑜𝑟𝑡𝑒𝑟 𝑠𝑝𝑎𝑛 5′
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(6′ + 5′)
ℎ= = × 12 = 1.467"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
33
Factored Live Load
WL = 1.6 x 40 = 64 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 5′
= = 0.92
𝑙𝑏 6′
Case
One long side continuous → Case 6
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
34
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 9587.573
3
𝑀𝑏. 𝑛𝑒𝑔 = 3195.85 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 58.10 𝑝𝑠𝑖
𝜌 = 0.0001977
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
35
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 100.18 𝑝𝑠𝑖
𝜌 = 0.001695
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 19.36 𝑝𝑠𝑖
𝜌 = 0.000324
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 63.12 𝑝𝑠𝑖
𝜌 = 0.00106
36
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 85.14 𝑝𝑠𝑖
𝜌 = 0.001437
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 16.38 𝑝𝑠𝑖
𝜌 = 0.000274
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
37
Shear Check
Total applied load = 12’ x 13’ x 195 = 30420 lb
Wa = 0.58 , Wb = 0.42
FINAL OUTPUT
T. V. LOUNGE PANEL -1
Longer span = 17 ft
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(17′ + 11.25′)
ℎ= = × 12 = 3.8"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
38
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
WL = 1.6 x 40 = 64 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 11.25′
= = 0.66
𝑙𝑏 17′
Case
One short side discontinuous → Case 9
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
39
Positive moments for slab middle strips
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 4448.75
3
𝑀𝑏. 𝑛𝑒𝑔 = 1482.91 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 60.980 𝑝𝑠𝑖
40
𝜌 = 0.001026
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 125.4005 𝑝𝑠𝑖
𝜌 = 0.00213
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝜌𝑢𝑠𝑒𝑑 = 0.00213
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 20.32 𝑝𝑠𝑖
𝜌 = 0.000340
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
41
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 29.29 𝑝𝑠𝑖
𝜌 = 0.00049
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 29.81 𝑝𝑠𝑖
𝜌 = 0.000499
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 20.32 𝑝𝑠𝑖
𝜌 = 0.00034
42
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 11.25’ x 17’ x 195 = 37293.75 lb
Wa = 0.914 , Wb = 0.086
FINAL OUTPUT
T. V. LOUNGE PANEL -2
Longer span = 14 ft
43
𝐿𝑜𝑛𝑔𝑒𝑟 𝑠𝑝𝑎𝑛 14′
= = 1.9 < 2
𝑆ℎ𝑜𝑟𝑡𝑒𝑟 𝑠𝑝𝑎𝑛 7.25′
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(14′ + 7.25′)
ℎ= = × 12 = 2.83"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
WL = 1.6 x 40 = 64 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 7.25′
= = 0.52
𝑙𝑏 14′
Case
One short and one long side continuous → Case 4
Co-efficient
From coefficient tables
44
Ca. dl = 0.0578 , Cb. dl = 0.0044
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 2228.75
3
45
𝑀𝑏. 𝑛𝑒𝑔 = 742.918 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 40 𝑝𝑠𝑖
𝜌 = 0.00067
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 58.76 𝑝𝑠𝑖
𝜌 = 0.00098
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 13.33 𝑝𝑠𝑖
46
𝜌 = 0.000223
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 14.67 𝑝𝑠𝑖
𝜌 = 0.00024
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 15.98 𝑝𝑠𝑖
𝜌 = 0.00026
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
47
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 3.8 𝑝𝑠𝑖
𝜌 = 0.000064
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 7.25’ x 14’ x 195 = 19792.5 lb
Wa = 0.932 , Wb = 0.068
FINAL OUTPUT
48
PORCH SLAB PANAL-1
Longer span = 13.5 ft
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(13.5′ + 7.25′)
ℎ= = × 12 = 2.8"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 7.25′
= = 0.54
𝑙𝑏 13.5′
49
Case
One short side discontinuous → Case 9
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
50
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 2761.744
3
𝑀𝑏. 𝑛𝑒𝑔 = 920.58 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 48.76 𝑝𝑠𝑖
𝜌 = 0.000819
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 81.29 𝑝𝑠𝑖
𝜌 = 0.001372
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
51
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 16.25 𝑝𝑠𝑖
𝜌 = 0.000272
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 18.18 𝑝𝑠𝑖
𝜌 = 0.000304
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 15 𝑝𝑠𝑖
𝜌 = 0.000251
𝜌𝑚𝑖𝑛 = 0.0018
52
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 4.719 𝑝𝑠𝑖
𝜌 = 0.00007
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 7.25’ x 13.5’ x 291 = 28481.63 lb
Wa = 0.954 , Wb = 0.046
FINAL OUTPUT
53
Long Direction # 3 @ 10in c/c
Discontinuous Short Direction # 3 @ 10in c/c
Edge
Long Direction # 3 @ 10in c/c
Mid Span Short Direction # 3 @ 10in c/c
Long Direction # 3 @ 10in c/c
Shorter span = 13 ft
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(13.5′ + 13′)
ℎ= = × 12 = 3.53"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
Aspect Ratio
la = shorter span
54
lb = longer span
𝑙𝑎 13′
= = 0.96
𝑙𝑏 135′
Case
One long side continuous → Case 6
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
55
𝑀𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙 = 17405.46 𝑙𝑏. 𝑖𝑛
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 17405.46
3
𝑀𝑏. 𝑛𝑒𝑔 = 5801.81 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 110.42 𝑝𝑠𝑖
𝜌 = 0.001871
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝜌𝑢𝑠𝑒𝑑 = 0.001871
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
56
𝑅𝑛 = 224.47 𝑝𝑠𝑖
𝜌 = 0.0038
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝜌𝑢𝑠𝑒𝑑 = 0.0038
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 36.80 𝑝𝑠𝑖
𝜌 = 0.000617
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 114.60 𝑝𝑠𝑖
𝜌 = 0.00194
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝜌𝑢𝑠𝑒𝑑 = 0.00194
57
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 0 𝑝𝑠𝑖
𝜌=0
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 29.74 𝑝𝑠𝑖
𝜌 = 0.00049
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 13.5’ x 13’ x 291 = 51070.5 lb
Wa = 0.742 , Wb = 0.258
58
51070.5 × 0.258
= = 506.77 𝑙𝑏/𝑓𝑡
2 × 13
FINAL OUTPUT
59
FIRST FLOOR
Note: The slab design for the first floor is the same as slab design of ground floor as the
architectural design and dimensions are same.
BEDROOM ─ 1, BEDROOM ─ 2
Slab thickness = 5 in
BATHROOM ─ 1, BATHROOM ─ 2
Slab thickness = 5 in
KITCHEN
Slab thickness = 5 in
60
BATHROOM ─ 3
Slab thickness = 5 in
DINING ROOM
Slab thickness = 5 in
DRAWING ROOM
Slab thickness = 5 in
BATHROOM ─ 4
Slab thickness = 5 in
61
Long Direction # 3 @ 10in c/c
T. V. LOUNGE PANEL -1
Slab thickness = 5 in
T. V. LOUNGE PANEL -2
Slab thickness = 5 in
62
Discontinuous Short Direction # 3 @ 10in c/c
Edge
Long Direction # 3 @ 10in c/c
Mid Span Short Direction # 3 @ 10in c/c
Long Direction # 3 @ 10in c/c
TOP FLOOR
MUMTY
Longer span = 20.25 ft
Slab Thickness
𝑝𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2(20.25′ + 12.08′)
ℎ= = × 12 = 4.3"
180 180
Minimum slab thickness = 5 in
h = 5 in
Cover = ¾”
d = h ̶ cover
d = 5” ̶ ¾”
d = 4.25”
Load Calculation
Dead Load
WL = 1.6 x 40 = 64 psf
63
Wu =WL + WD = 64 +131 = 195 psf
Aspect Ratio
la = shorter span
lb = longer span
𝑙𝑎 12.08′
= = 0.6
𝑙𝑏 20.25′
Case
One short side discontinuous → Case 9
Co-efficient
From coefficient tables
Moments
Negative moments for slab middle strips at continuous edges
𝑀𝑎.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑎.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑎 2
𝑀𝑎.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑎.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑎 2
𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 = 𝐶𝑏.𝑑𝑙 × 𝑊𝐷 × 𝑙𝑏 2
𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙 = 𝐶𝑏.𝑙𝑙 × 𝑊𝐿 × 𝑙𝑏 2
64
𝑀𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙 = 𝑀𝑏.𝑝𝑜𝑠.𝑑𝑙 + 𝑀𝑏.𝑝𝑜𝑠.𝑙𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = 𝑀
3 𝑏.𝑝𝑜𝑠.𝑡𝑜𝑡𝑎𝑙
1
𝑀𝑏. 𝑛𝑒𝑔 = × 4782.96
3
𝑀𝑏. 𝑛𝑒𝑔 = 1594.323 𝑙𝑏. 𝑖𝑛
Reinforcement
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
Short Direction
𝑅𝑛 = 76.22 𝑝𝑠𝑖
𝜌 = 0.00128
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 148.78 𝑝𝑠𝑖
𝜌 = 0.00253
𝜌𝑚𝑖𝑛 = 0.0018
65
𝜌𝑚𝑎𝑥 = 0.021
𝜌𝑢𝑠𝑒𝑑 = 0.00253
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 25.40 𝑝𝑠𝑖
𝜌 = 0.000425
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Long Direction
𝑅𝑛 = 31.49 𝑝𝑠𝑖
𝜌 = 0.000527
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
66
NEGATIVE REINFORCEMENT – CONTINUOUS END
𝑅𝑛 = 29.51 𝑝𝑠𝑖
𝜌 = 0.000494
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
𝑅𝑛 = 25.40 𝑝𝑠𝑖
𝜌 = 0.000425
𝜌𝑚𝑖𝑛 = 0.0018
𝜌𝑚𝑎𝑥 = 0.021
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × ℎ
𝑀𝑎𝑥 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 = 2 × 5 = 10 𝑖𝑛
Shear Check
Total applied load = 12.08’ x 20.25’ x 195 = 47700.9 lb
Wa = 0.94 , Wb = 0.06
67
47700.9 × 0.06
= = 118.46 𝑙𝑏/𝑓𝑡
2 × 12.08
FINAL OUTPUT
68