Manual Xy-Wt01

This document summarizes the features and functions of the XY-WT01 digital thermostat switch, including: 1. It has modes for heating and refrigeration and can be set to turn equipment on or off based on reaching set temperatures. 2. It has alarms for high temperatures and delay start functions to prevent frequent switching of heating/cooling. 3. Parameters like temperature settings and calibrations can be adjusted and settings can be restored to factory defaults.

Uploaded by

Losp Pacman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views7 pages

Manual Xy-Wt01

This document summarizes the features and functions of the XY-WT01 digital thermostat switch, including: 1. It has modes for heating and refrigeration and can be set to turn equipment on or off based on reaching set temperatures. 2. It has alarms for high temperatures and delay start functions to prevent frequent switching of heating/cooling. 3. Parameters like temperature settings and calibrations can be adjusted and settings can be restored to factory defaults.

Uploaded by

Losp Pacman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

XY-WT01 Digital Thermostat Switch

Features:

Set Temperature --Set T; Backlash Temperature--Back T

1. Heating Mode H:
When Temperature ≤ Set T – Back T; Relay conduction, heating equipment begin to work;
when temperature ≥ Set T, Relay disconnect, heating equipment stop work;

2. Refrigeration mode C:
When Temperature ≥ Set T+Back T; Relay conduction, refrigeration equipment begin to work;
When Temperature ≤ Set T; Relay conduction, refrigeration equipment stop work;

3. High-Temperature Alarm ALA:


When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm and
disconnects the relay, any key stops the sound light;

4. Delay Start OPH:


When a normal heating or refrigeration work is done, the system starts to time T, and only after
the T≥OPH, the system can carry out the next round of heating or refrigeration work;

5. Temperature Correction Function OFE(-10.0 ~ 10.0℃):


The system will work for a long time and may have deviations that can be corrected by this
function, Temperature = Measured + Calibration;

6. Parameter Remote Read/Set:


The parameters such as setting temperature, backlash temperature, and temperature correction
can be set through UART.

7. Real-time Temperature Report:


If the temperature reporting function is turned on, the product is transmitted to the terminal by
the UART at 1s intervals, which facilitates data collection;

8. Relay enable (default enable):


If the relay is disabled, the relay remains disconnected;

9. Restore Factory Settings:


At the same time press the STOP, set key more than 3S, restore factory settings;

Working mode setting /backlash temperature :


1. In the running interface, short press SET key, enter the Quick setting interface;

2. After entering the Quick Setup interface, switch the parameters

3. Through the UP DOWN key, modify the parameter value, support short press/long press;

4. Long press SET to build more than 3S or continuous 6S without any key operation, exit quickly
set the interface, and save parameters;

Alarm temperature/Delay Start /temperature correction:

1. In the operating interface, long press SET more than 3s, enter the parameters to set the
interface;

2. Enter the parameter to set the interface, through the short press SET key to switch to set the
parameters;

3. Through the UP DOWN key, modify the parameter value, support short press/long press;

4. Long press SET3s above or continuous 6S without any key operation, exit parameter set
interface, and save parameters;

How to turn on high-temperature alarm (default off):

Enter the parameter setting interface, switch to the alarm parameter ALA, turn on or off the
high-temperature alarm function by short pressing the STOP button, and if the high-temperature
alarm function closes, ALA displays \'----\' as a reminder;

How to turn on delay start (default 0ff):

Enter parameter setting interface, switch to alarm parameter OPH, turn on or off
high-temperature alarm function by short Press STOP button if high-temperature alarm function
closes, OPH show \'---\' to remind;

Serial Control (MCU UART)


Communication standards: 9600bps,Data bits: 8
Stop Bits: 1
CRC: none
Flow control: none
CMD Description
Start start data upload
Stop stop data upload
Read Read the param setting
T: ON Temperature relay enable
T: OFF Temperature relay disable
H: ON Humidity relay enable
H: OFF Humidity relay disable
TS: XX.X Set start Temperature (-20.0~60.0)
TP: XX.X Set stop Temperature (-20.0~60.0)
HS: XX.X Set start Humidity (00.0~100.0)
HP: XX.X Set stop Humidity (00.0~100.0)
TC: XX.X Set Temperature Calibration (-10.0~10.0)
HC: XX.X Set Humidity Calibration (-10.0~10.0)