This document describes two logic faults in an elevator system: 1. A level 5 Err34 logic failure that requires manual reset and is caused by issues with logic failures or the operating days setting. 2. A level 4 Err40 runs timed out fault that automatically resets when the cumulative working time exceeds the set running time, or the running time setting is set to 0.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
411 views1 page

Monarch Validity Setting

This document describes two logic faults in an elevator system: 1. A level 5 Err34 logic failure that requires manual reset and is caused by issues with logic failures or the operating days setting. 2. A level 4 Err40 runs timed out fault that automatically resets when the cumulative working time exceeds the set running time, or the running time setting is set to 0.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Andhias ( 085799998000 )

The name of the Err34 logic failure Failure level 5


fault

Turn on the The default is invalid


condition
FC-01Bit15 is set to 1 on (except for logic failures).

Reset It is not automatic reset, manual reset


conditions

Fault judgment 1. The set operating days of F9-10 are reduced to less than 8 days;

2. The clock stops running, reports a fault for 40 hours, and can be reset after power
failure.

The above two points are in When the F9-10 setting is greater than 800, it does not work.

3. Logical failure. (program logic error).

The name of the Err40 runs timed out Failure level 4


fault

Turn on the Valid by default


condition

Reset Automatic reset


conditions

Fault judgment 1. F9-09 (cumulative working time) > F9-08 (set running time), F9-08 set to 0 to cancel this
fault.

Remarks F9-09 Cumulative working time is only timed when the elevator is running.
description
F9-10 runs in decreasing increments from the day it is set (with or without power-on).