01) CP Training-STARDOM Introduction
01) CP Training-STARDOM Introduction
Ng Chye Wee
Yokogawa Engineering Asia Pte Ltd Network Based Control System
3. FCN-500 Introduction
EUROPE
AUSTRIA(25)
BELGIUM(10)
BOSNIA AND
HERZEGOVINA(5)
SWITZERLAND(3) Europe
CZECH(5)
GERMANY(17) Asia NORTH and CENTRAL
SPAIN(12)
FRANCE(246)
More than AMERICA
Middle
30,000 units
UNITED KINGDOM(102) CANADA(97)
GREECE(65) East UNITED STATES (1069)
HUNGARY(122) MEXICO(5)
IRELAND(1) over 78 countries
ITALY(23)
LUXEMBOURG(2) Africa
NETHERLANDS(449)
NORWAY(2)
POLAND(111)
Oceania
ASIA
PORTUGAL(14)
ROMANIA(33) BANGLADESH(129) South
RUSSIA(1578) BRUNEI(2) America
SERBIA(1) CHINA(2903)
SLOVAKIA(1) MIDDLE EAST HONG KONG(7)
INDONESIA(135)
SLOVENIA(8) UAE(488)
INDIA(831)
UKRAINE(10) BAHRAIN(1666)
IRAN(200)
OCEANIA JAPAN(5944)
AFRICA IRAQ(29) AUSTRALIA(3190) KAZAKHSTAN(160)
KOREA(109)
MOROCCO(8) KUWAIT(93) NEW ZEALAND(300)
ALGERIA(611) OMAN(350)
SRI LANKA(2) SOUTH AMERICA
EGYPT(256) MALAYSIA(70) ARGENTINA(364)
QATAR(101)
KENYA(1) PAKISTAN(5) BRAZIL(367)
SAUDI ARABIA(5506)
LIBYA(3) PHILIPPINES(10) CHILE(34)
SYRIAN(16)
MAURITIUS(1) SINGAPORE(800) COLOMBIA(130)
TURKEY(11)
NIGERIA(11) THAILAND(347) ECUADOR(1)
YEMEN(126)
SUDAN(2) TURKMENISTAN(6) PERU(130)
BOLIVIA(6)
TUNISIA(2) TAIWAN(29) VENEZUELA(50)
JORDEN(2)
TANZANIA(16) VIET NAM(65)
GHANA(10)
SOUTH AFRICA(82) * Based on the delivered number of CPU Module(NFCP501/502,NFCP050,NFCP100) and FCJ
| Document Number | June 1, 2017 |
© Yokogawa Electric Corporation
DO NOT DISTRIBUTE
DO NOT DISTRIBUTE 5
STARDOM –Hybrid PLC
Hybrid
DCS PLC
PLC
FA-M3R
Centum VP
Scale
(I/O
Size)
Stardom
UT Advanced UT Advanced
Small Redundancy Function No Redundancy Function Modular Type (Building Block) Compact Type
2
Types
Compact
hazardous locations.
• Additional cost savings in duplexed configuration where
design CPUs are mounted on the same base plane thus does not
require separate racks or panels.
Integration
• Controller Event Buffer realize high reliable
communication for bad network condition.
• FAST/TOOLS can handle event buffer for
For highly reliable communication recovering Trend Graph.
Network Network
Fail Recover
Value
Network
recovers
HART
Serial
Modbus
Industrial use
surveillant Camera
Card Reader
Graphic Panel
Supports a wide range of
fieldbus protocols
Rich SCADA ■ FOUNDATION fieldbus H1, HART,
communication Modbus, PROFIBUS-DP, CANopen, RS-
■ DNP3, Modbus, OPC available 232/422/485
using CPU ports
■ Eliminates need to invest in
communication modules and
communication gateways
Seamless
communication.
• Process control Related Graphics(Faceplate,
Faceplate window
Tuning window
Reliable
- Base, CPU, Control Network, Expansion
module, Expansion bus
CPU Replace
Remove terminal block for disconnecting Replace New I/O module and
field wirings. attach terminal block. Tools not required
IO Replace (No need to disconnect each field wiring)
IO definition automatically copied
Ease
• Utilizes global standard IEC 61131-3 (five programming languages).
• Tag-based definitions simplify engineering and re-mapping of tags or memory
address assignments are not required.
of Engineering &
• Supports Function Block Diagram, Ladder Diagram, Structured Text, Instruction List
Maintenance
and Sequential Function Chart
Function Sequential
Ladder Instructio
Block Function Structured
Diagram n List
Diagram Chart Text (ST)
(LD) (IL)
(FBD) (SFC)
E2 bus
Interface Module
| Document Number | June 1, 2017 |
© Yokogawa Electric Corporation
16
Stardom New Features (E2bus)
E2 bus
Interface Module
1
9
2
7 or 9
8
3
4 7 4
With one CPU module, 5
the maximum number
of units that can be 6 2
controlled is three times
greater (9 units), and the
maximum number of modules
is 79.
E2 bus
FN110
Field Wireless
Communication
Module
#1
LN90
Interface Adapter
#2
500 m #20
FCN-500
CPU Module
FCN-500 Configuration
IO Module FCN-500
IO Module CPU Module
1
IO Module
22
2
IO Module
3
IO Module
IO Module
5
IO Module
6
IO Module
Duplex Power & CPU Module, 1 node
FCN-RTU Hardware Configuration
FCN-RTU CPU
Module
1
IO Module
2
IO Module
3
Short Base
IO Module
Single Power
FCN-RTU Configuration
Power Supply
24
Module
Power Supply
Module
IO Module
3
IO Module
Long Base
IO Module
5
IO Module
Duplex Power
IO Module
7
IO Module
8
IO Module
Applications and Industries
Annotation Annotation
Intelligent RTU/PLC
Features
Applicable to large system
Three times the max. number of I/Os E2 bus interface
module
Distributed I/O
Transmission distance extended
Flexible arrangement
Select from various sizes of base module
High reliability
Redundant bus
High maintainability
Online module exchange
RAS Information
High environmental resistance
Withstands temperatures from -20 to 70 ℃
Note: The E2 bus cannot be used together with an existing SB bus repeat module.
| Document Number | June 1, 2017 |
© Yokogawa Electric Corporation
31
32
E2 Bus: List of Newly Released Models
Max. I/O configuration example CPU load comparison between NFCP100 and NFCP50x
Former CPU
SB bus E2 bus (NFCP100)
NFCP501/502
+ E2 bus
(3 units) (9 units) + SB bus
Task period 100 msec
AI 96 288
AO 32 96
DI 256 768
DO 256 768
PID loop 32 96
Total I/O 640 1920
CPU load 69% 22% 57%
SB bus E2 bus
Max. 8 m / line Max. 100 m / between units
Control unit First line
100m
8m
Second line
Note: Refer to the Yokogawa Web site below (registration required) for the verified media converters.
“System Requirements” => “Verified Peripherals ”page in the “YOKOGAWA Partner Portal STARDOM” site.
https://partner.yokogawa.com/global/member/rtu/peripheral/index.htm
Refer to the TI 34P02Q91-01E “FCN/FCJ Installation Guide” for installation precautions.
Ethernet cable
1 km 2 km 2 km
Out of support example The distance between media converters must be within the converter
specification.
Only a pair of media converters can be used * For the verified converters, the distance is up to 2 km. (As of April 2018)
between two units.
3 km
2㎞ 2㎞ 1㎞ 1㎞
Control unit
Master module
Space in the control panel can be used effectively by selecting the appropriate base module
Even if the power to one extension unit goes off, the connection
between the control unit and the other units can be maintained.
System information
SB bus E2 bus
The control unit by itself supports a Even with multiple unit configuration, each
temperature range of -20 to 70℃
unit supports the wide temperature range of
-20 to 70℃
E2 bus is available
Works as small footprint control unit or remote I/O
Duplex E2 bus is available for extension units*2
Can be used for FCJ FCN-500*3 replacement
Same width as FCJ*4
FCJ
STARDOM Renewal
New FCN-500 CPU release
■Higher performance
■Simplified operation
■Higher reliability
- New FCN CPU release
- Engineering tool
Engineering tool enhancement
enhancement
■Logic Designer enhancement
- Communication function
enhancement R4.02/R7.50
- Enhancement for upstream market (2016/4 FD)
- PC environment enhancement
- FCN-RTU enhancement for
R3.50/R7.40 ※R4.01 is for specific
upstream market
(2015/6 FD) customers
- PC environment enhancement
SD LED
SD card slot
Modbus
DNP3
オプション
AGA オプション
ライセンス
Option
ライセンス
license Embedded
・・・ licenses
Basic Select CPU
Select basic license
Software type only [HW]
[Basic license] License
CPU
Single (Standard)
CPU CPU
Duplex CPU
Select HW Base, PU, Base, PU, (Extended)
IO IO
[HW] Base
Same type of
modules
Same type of
modules
License
files
Set IP address
The battery is
on the back-side
CPU load
NFCP500 19%
0 20 40 60 80 100 120 140 160 NFCP100 95%
(CASE Study: 120 PID loops with 150 msec scan rate on redundant CPU)
* Environments for additional solutions will be provided in the future.
Port 2
Port 1
Independent network
Exclusive port for
on each port
engineering or maintenance
Field network Redundant field network*
VJET Engineering PC
NFSB100
NFSB100
NFSB100
PWM
PWM
PWM
PWM
DMY
CPU
CPU
CPU
CPU
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
NFBU200 NFBU200 NFBU050
NFCB301 NFCB301
NFSB100
NFSB100
NFSB100
PWM
PWM
PWM
DMY
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
NFBU200 NFBU200
NFCB301 NFCB301
NFSB100
NFSB100
NFSB100
PWM
PWM
PWM
DMY
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
NFBU200 NFBU200
NFPW444
NFPW444
NFPW444
NFCP500
NFCP500
NFCP500
NFCP500
DMY
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
IOM
NFBU200 NFBU200 NFBU050
CPU Cover
Wire lock hole