0900766b816a5796
0900766b816a5796
0900766b816a5796
com/gb/products/2866682
Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking)
Technology, input: 1-phase, output: 48 V DC/10 A
Product Description
QUINT POWER power supplies with maximum functionality
QUINT POWER circuit breakers magnetically and therefore quickly trip at six times the nominal current, for selective and therefore cost-effective
system protection. The high level of system availability is additionally ensured, thanks to preventive function monitoring, as it reports critical
operating states before errors occur.
Reliable starting of heavy loads takes place via the static power reserve POWER BOOST. Thanks to the adjustable voltage, all ranges between 5
V DC ... 56 V DC are covered.
Your advantages
Quick tripping of standard circuit breakers
Reliable starting of difficult loads
Preventive function monitoring
GTIN
GTIN 4046356307680
Weight per Piece (excluding packing) 1,600.000 g
Custom tariff number 85044030
Country of origin Thailand
Technical data
Dimensions
Width 90 mm
Height 130 mm
Depth 125 mm
Width with alternative assembly 122 mm
Height with alternative assembly 130 mm
01/09/2019 Page 1 / 10
https://www.phoenixcontact.com/gb/products/2866682
Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height 6000 m
Input data
Nominal input voltage range 100 V AC ... 240 V AC
Input voltage range 85 V AC ... 264 V AC
90 V DC ... 350 V DC (UL 508: ≤ 250 V DC)
Dielectric strength maximum 300 V AC
AC frequency range 45 Hz ... 65 Hz
Frequency range DC 0 Hz
Discharge current to PE < 3.5 mA
Current consumption 5.1 A (120 V AC)
2.3 A (230 V AC)
4.8 A (110 V DC)
2.4 A (220 V DC)
Nominal power consumption 572 VA
Inrush surge current < 20 A (typical)
Mains buffering > 20 ms (120 V AC)
> 20 ms (230 V AC)
Input fuse 12 A (slow-blow, internal)
Choice of suitable circuit breakers 10 A ... 16 A (AC: Characteristics B, C, D, K)
Type of protection Transient surge protection
Protective circuit/component Varistor
Output data
Nominal output voltage 48 V DC ±1 %
Setting range of the output voltage (USet) 30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
Nominal output current (IN) 10 A (-25 °C ... 60 °C, UOUT = 48 V DC)
POWER BOOST (IBoost) 13 A (-25°C ... 40°C permanent, UOUT = 48 V DC )
Selective Fuse Breaking (ISFB) 60 A (12 ms)
Derating 60 °C ... 70 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series yes
01/09/2019 Page 2 / 10
https://www.phoenixcontact.com/gb/products/2866682
General
Net weight 1.7 kg
Efficiency > 93 % (for 230 V AC and nominal values)
Insulation voltage input/output 4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage input / PE 3.5 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE 500 V DC (routine test)
Protection class I
Degree of protection IP20
MTBF (IEC 61709, SN 29500) > 900000 h (25 °C)
> 630000 h (40 °C)
Mounting position horizontal DIN rail NS 35, EN 60715
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active
components, 50 mm vertically
Assembly instructions
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm
vertically bottom
01/09/2019 Page 3 / 10
https://www.phoenixcontact.com/gb/products/2866682
01/09/2019 Page 4 / 10
https://www.phoenixcontact.com/gb/products/2866682
Drawings
Block diagram
L (+)
active
N (-) PFC
DC OK
I < IN
13
14
Classifications
eCl@ss
01/09/2019 Page 5 / 10
https://www.phoenixcontact.com/gb/products/2866682
ETIM
UNSPSC
Approvals
Approvals
Approvals
DNV GL / CSA / UL Listed / UL Recognized / cUL Recognized / IECEE CB Scheme / cUL Listed / SEMI F47 / EAC / EAC / cULus Recognized /
cULus Listed
Ex Approvals
Approval details
DNV GL
http://exchange.dnv.com/tari/ TAE000014W
CSA
http://www.csagroup.org/services-industries/product-listing/ 2162676
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528
01/09/2019 Page 6 / 10
https://www.phoenixcontact.com/gb/products/2866682
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944
IECEE CB Scheme
http://www.iecee.org/ SI-2283 A1
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528
EAC
EAC-Zulassung
RU C-
EAC
DE.A*30.B.01082
cULus Recognized
cULus Listed
Accessories
Accessories
Assembly adapter
01/09/2019 Page 7 / 10
https://www.phoenixcontact.com/gb/products/2866682
Universal wall adapter for securely mounting the power supply in the event of strong vibrations. The power supply is
screwed directly onto the mounting surface. The universal wall adapter is attached at the top/bottom.
Device protection
Type 2/3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote
signaling for single-phase power supply networks. Nominal voltage 230 V AC/DC.
Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote
signaling for single-phase power supply networks. Nominal voltage 60 V AC/DC.
Redundancy module
Diode - QUINT-DIODE/48DC/2X20/1X40 - 2320160
DIN rail diode module 48 V DC/2x20 A or 1x40 A. Uniform redundancy up to the consumer.
01/09/2019 Page 8 / 10
https://www.phoenixcontact.com/gb/products/2866682
Redundancy module - TRIO-DIODE/48DC/2X10/1X20 - 2866527
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
01/09/2019 Page 9 / 10
https://www.phoenixcontact.com/gb/products/2866682
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 PDT contact, plug for base element.
01/09/2019 Page 10 / 10