The EuP Directive is subsequently replaced by the ErP Directive 2009/125/EC published on 31 October 2009, with an extended
scope covering all energy-related products. The ErP Directive has taken effect since 20 November 2009. It published
Implementing Measures including 10 different types of measures.
Producers must comply with the ErP Directive's requirements, and follow the CE conformity assessment modules
to prepare product-related environmental technical-documentation file before sold on the EU market.
(a) Power consumption Power consumption of equipment in any Power consumption of equipment in any off-mode
in "off mode": off-mode condition shall condition shall not exceed 0.0 W.
(b) Power consumption The power consumption of equipment in any The power consumption of equipment in any
in "standby mode(s)": conditions providing only a reactivation function, condition providing only a reactivation function,
or providing only a reactivation function and a or providing only a reactivation function and a
mere indication of enabled reactivation function, mere indication of enabled reactivation function,
shall not exceed 1,00 W. shall not exceed 0,50 W.
The power consumption of equipment in any The power consumption of equipment in any
condition providing only information or status condition providing only information or status
display, or providing only a combination of display, or providing only a combination of
reactivation function and information or status reactivation function and information or status
display, shall not exceed 2,00 W. display shall not exceed 1,00 W.
(c) Availability of off mode Equipment shall, except where this is inappropriate Equipment shall, except where this is inappropriate
and/or standby mode: for the intended use, provide off mode and/or for the intended use, provide off mode and/or
standby mode, and/or another condition which standby mode, and/or another condition which does
does not exceed the applicable power consumption not exceed the applicable power consumption
requirements for off mode and/or standby mode requirements for off mode and/or standby mode
when the equipment is connected to the mains when the equipment is connected to the mains
power source. power source.
(d) Power management - NIL - When equipment is not providing the main function,
or when other energy-using product(s) are not
dependent on its functions, equipment shall, unless
inappropriate for the intended use, offer a power
management function, or a similar function, that
switches equipment after the shortest possible
period of time appropriate for the intended use of
the equipment, automatically into:
- Standby mode, or
- Off mode, or
- Another condition which des not exceed the
applicable power consumption requirements for
off mode and/or standby mode when the
equipment is connected to the mains power source.
The power management function shall be activated
before delivery.
AC-AC external power supplies, except low AC-AC external power supplies, except low Low voltage external
voltage external power supplies voltage external power supplies power supplies
The average active efficiency shall be not less than the following limits:
Specialized Technology Resources (H.K.) Ltd. is the first Hong Kong laboratory, has obtained HOKLAS accreditation on test
standard (IEC / EN /BSEN 62301) for ErP testing for standby and off mode electric power consumption. (For details of our
HOKLAS scope of accreditation, please visit: http://www.itc.gov.hk/en/quality/hkas/doc/hoklas/036.pdf). For further details
of ErP testing service, please feel free to contact our representatives for more information: