: HE-MRUT-006/23 Page 1 of 3
MEDIUM RANGE GUIDED WAVE ULTRASONIC TESTING REPORT Our Reference : -
Test Date : February 24, 2023
Client : Harbour Energy Job No. : -
Project : MRUT (CUPS) Equipment : PowerBox H Tuning Module : 205T0015-LF
Item No. : M07 TEG GAS DEHYDRATION Sensor : 205C0469 Scanner : PN 274A0244
Drawing No. : - Tested Material : Carbon Steel/A36
Acceptance Standard : - Procedure No. : ExWI-NDT-18052
Stage of Examination As Weld As Base Metal After Repair Coaxial Cable Type/ Length : 1.5 m
After weld 12 Hrs. Before PWHT After PWHT Other Ref./ Sensitivity Setting : Flat Bottom Holes 5 mm
Surface Preparation Grinding Brushing by power tool Scanning Sensitivity : + 6 dB Scanning Speed : >150 mm/s
Location Sizing
Location No. Indication No. Findings (Indications) Remarks / Follow up Priority
X-Line Y-Line Width Amplitude (%) Estimated Wall Loss
8-HG-21-423-9A3 (S5) - - - - - - No anomaly indication was detected N/A
Remark/Test Restriction : WL ≤ 25% ( WL ≤ 1.78 ; 25% < WL ≤ 50% (1.78<WL≤3.56) ; WL > 50% (WL>3.56) Estimated Cross - Sectional Wall Loss
P2: Estimated Measured thickness <= nominal-corrosion allowance, P3: Estimated measured thickness >= nominal-corrosion allowance
P1: High P2: Medium P3: Low 1.3 < Estimated Measured thickness <= 3 mm, P1 for HC service, P2 nonhydrocarbon service, P3 for portable water
P1: Estimated measured thickness <=1.3
280 mm.
Test Range 0.0 - 2,400 mm.
770 mm.
W1 0º
- -
TP 1
90º
180º
8-HG-21-423-9A3 (S5)
0º
W1
TP 1