Since Ellman® International was founded in 1959, the company has grown to b ­ ecome a ­global ­leader in advanced
radiofrequency (RF) Technology for precision surgical and aesthetic p ­ rocedures. In 2014 Ellman® was acquired by I RF GENERATORS
Cynosure®, Inc. the world‘s leading aesthetic laser company. In 2017 Cynosure® was acquired by Hologic, Inc. and now
represents the ­aesthetic ­division. Today, Ellman® remains a strong surgical RF brand within Cynosure® and serves the Aesthetics & Surgical Capabilities 5
­aesthetic, multi-specialty surgical, dental and veterinary markets. Surgical Capabilities 6-7

The Ellman® brand‘s reputation is known for providing high quality, reliable products including the l­ egacy Surgitron® II RF RADIOSURGERY ACCESSORIES
line of RF surgical Generators and the newer Pellevé® Wrinkle Reduction and Body Treatment System.
Neutral Plates 8-9
With a foundation based on excellence in Advanced Laser and RF Technologies, a strong research and development Cables 10-11
program and established worldwide sales channels, the commitment of C­ ynosure® to sustained growth will result in Footswitches 12
long term success. Converter & Adapter 13
Handpieces 14-15
Bipolar Forceps 16-17

Distinct benefits
Bayonet Bipolar Forceps 18-19
ACe-Tip™ Non-Stick Forceps 20-21

for your practice


III RF ELECTRODES

Sterile/Single-Use Electrodes 23
Empire® Microincision™ Needles 24-25

The Features IV RF REUSABLE ELECTRODES
• Exceptional precision and control through two distinct frequencies - Monopolar (4.0 MHz) and Bipolar (1.7 MHz)
• 73% less thermal spread as compared to Bovie® 1250 and Valleylab® ForceFX™ in porcine tissue3 Standard Electrodes 26-31

• Easy operation with clear setting display via Digital Control Panel Insulated Electrodes 31

• Reliable, consistent energy emission through Solid State Circuitry ACe-Tip™ Advanced Composition Alloy 32
Specialty Electrodes 32

The Benefits Reusable Electrode Sets 33

• Precision - sculpt precise incisions and excisions in very thin, delicate mobile or tension-free tissues
V ACCESSORIES
(e.g. eyelid skin, earlobe, labia, etc.)2
• Less burning or charring of tissues1 Surgical Cart 34
• Enhanced readability of histologic specimens 8
Miscellaneous 35
• Excellent cosmetic results with minimal scar tissue 4,5

• Quick recovery6 VI MULTI-SPECIALTY ACCESSORIES


• Decreased post-operative pain7 Family Practice/Podiatry 36-37
Otorhinolaryngology 37-40
The Return Gynecology 41-42
• With versatility across all specialties, Surgitron® Technology is a proven workhorse that will deliver years of Ophthalmology/Oculoplastics 43
reliable, cost-effective performance in both hospital and office environments
Plastic Surgery 44
Pellevé® Wrinkle Reduction System 45-47
PelleFirm® RF Body Treatment 46
Miscellaneous 47
Clinical Citations
1. High frequency RF surgery minimizes burning of tissue, unlike laser or conventional 5. Aferzon, M, Derm Surgery (2002); vol 28, p735-738.
electrosurgery. Olivar, AC, et al, Ann. Clin. Lab Sci. (1999); 29 (4): p281-5. 6. With less tissue destruction, healing is accelerated and patients can recover quickly.
2. N iamtu, J. Chapter 4B, “Radiowave Surgery in Oral and Maxillofacial Surgery”, Bridenstine, J.B., Derm Surgery (1998); vol 24, p397-400.
in Distraction Osteogenesis of the Facial Skeleton, 2007, p30-37.
3. Data on file.
7. High frequency RF surgery causes less trauma7. Ericsson, E, et al, The Laryngoscope
(2007); vol 117, p654. 3
4. Botero, G.E.S, J Otol Head Neck Surgery (1996); vol 24 (1), p69. 8. Minimal Heat Dissipation. Silverman, EB, et al, Veterinary Surgery (2007); vol 36, p50-56.
How does RF GENERATORS
Radiosurgery work?
A radiofrequency Electrode tip becomes energized by the high frequency energy but
does not become hot. This energy provides specific and delicate tissue i­nteraction,
­resulting in a focused cutting and coagulating effect, which disintegrates and v­ olatilizes
cells thereby m­ inimizing the amount of lateral tissue destruction. Healing is rapid and
pain is minimized with reduced tissue damage.

Distinct waveforms for Pellevé® S5


optimum clinical outcomes The Pellevé® S5 System is a more advanced version of our proven Surgitron® Dual 120 RF Generator, providing maximum
control in precision cutting and coagulation, plus more versatility than other energy-based technologies, including.

Cut
• Micro-smooth cutting
Pellevé® S5 RF Wrinkle Reduction
• Negligible lateral heat
• Ideal for skin incision and biopsy Generator • GlideSafe® Wrinkle Treatment
Handpieces for Skin Tightening*
• Best cosmetic results 1,2 220 - 240 V • PelleFirm® Body Treatment
Handpieces for temporary
Blend Reduction in Apperance of Cellulite.
• Cutting with hemostasis • Hundreds of surgical Electrodes
• Ideal for subcutaneous tissue dissection and planing and Accessories available
Especially ­useful in vascular areas while producing minimal
• Ideal for Office and Clinic
amounts of lateral heat and tissue damage Environments

| RF GENERATORS | Aesthetics & Surgical Capabilities


Coag IEC5P-ST/220
• Coagulation Shipped complete with:
• Ideal for hemostasis with controlled penetration 40-0417 EU Power cord
40-0419 UK Power cord

Fulguration
DF-FSC# Dual Footswitch & Cable
IEC-HP1 IEC Foot-Controlled Handpiece
IEC-3FHPB IEC 3-Button Fingerswitch Handpiece GlideSafe® Wrinkle
• Ideal for intentional tissue destruction IEC-1FHPA 1-Button FSHP, Locking Chuck, Reusable, 1 pc
IEC-NPD IEC Neutral Plate
Treatment Handpieces

Bipolar
DSEP40 40 Medical Electrodes Assortment
Package Sterile/Single-Use
H66 Electrode ProtectorStand
• Pinpoint, micro-coagulation H79 Handpiece Clip
“J” Series Bipolar Forceps
• Ideal for coagulation in and around critical anatomy (Item number determined by selection) see page 16-19 PelleFirm® Handpieces
NOTE: Included accessories may vary by country and/or by special packages. with massage head

Powered by advanced RF Technology, the Pellevé® S5 energy source has advanced cooling and electronics inside that deliver the
performance needed to power the GlideSafe® wrinkle Treatment Handpieces and PelleFirm® Body Treatment Handpieces. Since
it evolved from the Surgitron® Dual 120, it also has full surgical capabilities, providing unparalleled surgical precision in soft tissue
cutting and coagulation. The high frequency of 4.0 MHz minimizes thermal tissue damage along the incision path. The S5 offers
complete versatility, with more options for use in surgical and aesthetic procedures than other energy-based platforms. The Pellevé®
S5 redefines your surgical results with two distinct frequencies - 4.0 MHz (Monopolar) and 1.7 MHz (Bipolar) - for outstanding precision
Clinical Citations
4 1. With less tissue destruction, healing is accelerated and patients can recover quickly. Bridenstine, J.B., Derm Surgery (1998); vol 24, p397-400.
and control. The Pellevé® S5 is the only Ellman® energy source compatible with GlideSafe® and PelleFirm® Handpieces. 5
2. High frequency RF surgery causes less trauma7. Ericsson, E, et al, The Laryngoscope (2007); vol 117, p654.
I I

The Surgitron® The Surgitron®


Dual RF™ 120 Dual RF™ 90
For those doctors wanting to perform advanced surgical procedures. For those doctors wanting to perform advanced surgical procedures.

The Surgitron® Dual RF™ 120 Devices 4 Megahertz (MHz) Technology The Surgitron® Dual RF™ 90 Devices 4 Megahertz (MHz) Technology
creates very little heat when cutting/coagulating tissue, resulting in minimal lateral creates very little heat when cutting/coagulating tissue, resulting in minimal lateral
thermal damage to surrounding tissues. Like all of Ellman® Generators it operates in Cut, Blend, Coag thermal damage to surrounding tissues. Like all of Ellman® Generators it operates in Cut, Blend, Coag
and Fulgrate waveforms. It also includes Bipolar waveforms. and Fulgrate waveforms. It also includes Bipolar waveforms.

Surgitron® Dual RF™ 120 IEC 220 V Surgitron® Dual RF™ 90 IEC 220 V

Generates 120 Watts of Power IEC3A-S30/220 Generates 90 Watts of Power IEC3A-S30-90/220


4.0 MHz in Monopolar Shipped complete with: 4.0 MHz in Monopolar Shipped complete with:

1.7 MHz in Bipolar 1.7 MHz in Bipolar


| RF GENERATORS | Surgical Capabilities

| RF GENERATORS | Surgical Capabilities


40-0417 EU Power cord 40-0417 EU Power cord

Foot-Controlled Handpiece 40-0419 UK Power cord


Foot-Controlled Handpiece 40-0419 UK Power cord
DF-FSC# Dual Footswitch & Cable DF-FSC# Dual Footswitch & Cable
3-Button Fingerswitch Handpiece IEC-HP1 IEC Foot-Controlled Handpiece 3-Button Fingerswitch Handpiece IEC-HP1 IEC Foot-Controlled Handpiece
Bipolar Forceps IEC-3FHPB IEC 3-Button Fingerswitch Handpiece Bipolar Forceps IEC-3FHPB IEC 3-Button Fingerswitch Handpiece
IEC-3FHPB/D Sterile/Single-Use IEC-3FHPB/D Sterile/Single-Use
Disposable Neutral Pad 3-Button Fingerswitch Handpiece Disposable Neutral Pad 3-Button Fingerswitch Handpiece

Electrode Assortment IEC-3FHPB/D1 Sterile 3-Button FSHP, Locking Chuck, 1 pc Electrode Assortment IEC-NPC IEC Neutral Plate
IEC-NPC IEC Neutral Plate DSEP40 40 Medical Electrodes
Size: 22.86cm x 12.7cm x 33.02cm DSEP40 40 Medical Electrodes
Size: 22.86cm x 12.7cm x 33.02cm Assortment Package
Sterile/Single-Use
Weight: 8,2 kg Assortment Package
Sterile/Single-Use
Weight: 8,2 kg H66 Electrode Protector Stand
H66 Electrode Protector Stand H79 Handpiece Clip
H79 Handpiece Clip “J” Series Bipolar Forceps
(Item number determined by selection) see page 16-19
“J” Series Bipolar Forceps
(Item number determined by selection) see page 16-19

NOTE: Included accessories may vary by country and/or by special packages.


NOTE: Included accessories may vary by country and/or by special packages.

6 7
II

RF RADIOSURGERY Neutral Plates


ACCESSORIES The Ellman® Single-Use Neutral Plate is a sensing, pre-gelled, self-adhering, dispersive pad. The
effective Electrodes are two aluminum oil conductors, covered by a hydrogel conductive adhesive.
The conductive hydrogel provides a low-current density return path from the patient to the RF
By understanding our customer’s needs, we provide specialty products to accommodate Device while the two foils provide a means of sensing contact quality.
every practice. Along with our family of RF Generators, we offer an extensive selection of
Monopolar and Bipolar accessories, available in Reusable and single/sterile use.
Our quality products provide consistent performance resulting in patient confidence.
IEC Disposable IEC-NPD
Standard Size, Single-Use
Neutral Plate For Dual RF™, Pellevé® S5, AcuSect®
II (25 pcs)

IEC Disposable IEC-NPD-S


Small Size, Single-Use
Neutral Plate For Dual RF™, Pellevé® S5, AcuSect®
and RadioLase® Devices
(25 pcs)

IEC Neutral Plate IEC-NPC


Reusable, Coated
For Dual RF™, AcuSect® and
RadioLase® Devices
(1 pc)
Note: For minor, low power procedures only
| RF ACCESSORIES | Neutral Plates

| RF ACCESSORIES | Neutral Plates


EMC Neutral Plate H4
Reusable, Coated
For the EMC Device
(1 pc)

IEC Neutral Pad IEC-NPD1


not illustrated Disposable
(1/PKG)

8 9
II II

Cables
Bipolar Cable Quick-Connect™ Cable
Ellman® offers both Reusable and single-use options for use with Bipolar For use with Suction Tonsil and Suction Adenoid Probes, Disposable Suction
Compatible Generators. See our family of Bipolar Forceps. Coagulators, Mono Stan RF Forceps and Rodin™ Micro Surgery Handpieces.

IEC-JX/B IEC-SP020
Reusable, Bipolar Reusable, Monopolar
For use with Surgitron® Dual RF™, Pellevé® S5, AcuSect® For use with Surgitron® Dual RF™, Pellevé® S5, AcuSect®
and RadioLase® Devices and RadioLase® Devices
(1 pc) (1 pc)

Snare Cable
JX For use with Polyp Snare™
Reusable, Bipolar
For use with EMC Device
(1 pc)

IEC-H7B
Reusable, Monopolar
For use with Surgitron® Dual RF™, Pellevé® S5, AcuSect®
and RadioLase® Devices
(1 pc)

JX/E
Reusable, Bipolar
For use with EMC Device
(1 pc)
| RF ACCESSORIES | Cables

| RF ACCESSORIES | Cables
10 11
II II

Footswitches Converter & Adapter


Footswitch activation for Ellman® Family of RF Generators. For use with Surgitron® FFPF EMC Generator.

Dual Frequency Footswitch & Cable Bipolar Converter

DF-FSC EMCH95A
For Surgitron® Dual RF™, Pellevé® S5, For use with EMC Device
AcuSect® and RadioLase® Devices (1 pc)
(1 pc)

Pneumatic Footswitch

SVFSC
Universal Fingerswitch
For use with Surg-e®-Vac™
Smoke Evacuation System
(1 pc)

EMCKA
Reusable
For use with EMC Device
Handpiece not included
(1 pc)
Footswitch 2 Pedal, Compact

| RF ACCESSORIES | Converter & Adapter


| RF ACCESSORIES | Footswitches

FTSW-2PC
For AcuSect® and RadioLase® Devices
(1 pc)

12 13
II II

Handpieces MicroInsulated Needle Handpiece with Locking Chuck

IEC-XH136
Ellman® Handpieces are ergonomicaly designed to fit comfortably in your hand therefore
For Surgitron® Dual RF™, Pellevé® S5, AcuSect®
maximizing productivity by reducing operator fatigue and discomfort.
and RadioLase® 3 Devices (2 pcs)

Reusable 3-Button Fingerswitch Handpiece with Locking Chuck XH136


For Surgitron® EMC Device (2 pcs)
Reusable (1 pc)
IEC-X3FHPB Smaller orifice for insertion of Ellman®
Reusable MicroInsulated Needles only (Cat. No. H137)
Accepts 1.59mm and 2.38mm Shaft Electrodes Included in Cosmetic Treatment Package
For Surgitron® Dual RF™ and Pellevé® S5 Devices
(2 pcs)

Foot-Controlled Handpiece with Locking Chuck


Single-Use 3-Button Fingerswitch Handpiece with Locking Chuck IEC-XHP1
For Surgitron® Dual RF™, Pellevé® S5, AcuSect®
and RadioLase® Devices
IEC-3FHPB/D
Sterile/Single-Use XHP1
Accepts 1.59mm and 2.38mm Shaft Electrodes For Surgitron® EMC Device
For Surgitron® Dual RF™ and Pellevé® S5 Devices Reusable (2 pcs)
(10 pcs) Accepts 1.59mm and 2.38mm Shaft Electrodes

1-Button Fingerswitch Handpiece with Locking Chuck Blade Handpiece with Locking Chuck

IEC-X1FHPA H15
Reusable For Surgitron® EMC Device
Accepts 1.59mm and 2.38mm Shaft Electrodes Accepts 1.59mm Shaft
For AcuSect® and RadioLase® Devices
(2 pcs)

| RF ACCESSORIES | Handpieces
| RF ACCESSORIES | Handpieces

1-Button Fingerswitch Handpiece with Locking Chuck Rodin® Microsurgery Handpiece


XRHP
XKO1 Length 9.89cm, Width 1.17cm
Reusable Reusable (2 pcs). Requires IEC Quick-Connect™ Cable
Accepts 1.59mm and 2.38mm Shaft Electrodes Accepts 1.59mm Shaft
(2 pcs) For Surgitron® Dual RF™, Pellevé® S5 AcuSect®
and RadioLase® Devices
(For Quick-Connect™ Cable, Cat. No. IEC-SP020)

14 15
II II

Bipolar Forceps 10 mm J1  Length 9.5cm


Ø 0.4mm
Straight Tip

Ellman® offers a variety of Bipolar Forceps with specialty specific shapes and sizes,
resulting in clean wet-field pinpoint coagulation. 10 mm J1B  Length 9.5cm
Ø 0.4mm
Bent Tip

J2  Length 9.5cm


5m
m Ø 0.3mm
Curved Flat/Angled Tip

8
m
m J3  Length 7.8cm
Ø 0.4mm
Angled Tip

8 mm
J4  Length 7.8cm
Ø 0.3mm
Straight Tip

10 mm
J10  Length 16.2cm
Ø 2.0mm
Straight Tip

10 mm
J11  Length 12.2cm
Ø 0.4mm
Straight Tip
| RF ACCESSORIES | Bipolar Forceps

| RF ACCESSORIES | Bipolar Forceps


10 mm
J12  Length 10.9cm
Surgitron® Dual RF™ Ø 1.0mm
Pellevé® S5, & RadioLase®
Straight Tip
Bipolar Cables

10 mm
J19  Length 13.6cm
Ø 2.0mm
Straight Tip

16 17
II II

Bayonet Bipolar Forceps


Enhanced access to the surgical environment for increased visibility.

J7  Length 17.3cm J17  Length 17.9cm


10 mm 10 mm
Ø 1.0mm, Bayonet Ø 1.0mm, Bayonet
Flat Tip Single External Tip Insulated

J7U  Length 17.3cm J18  Length 16.9cm


10 mm
Ø 1.0mm, Bayonet Ø 0.5mm, Bayonet
45° Up, Flat Tip

J7D  Length 17.3cm J20  Length 16.6cm


Ø 1.0mm, Bayonet 10 mm Ø 2.0mm, Bayonet
45° Down, Flat Tip
| RF ACCESSORIES | Bayonet Bipolar Forceps

| RF ACCESSORIES | Bayonet Bipolar Forceps


J13  Length 15.6cm J21  Length 19.7cm
10 mm
Ø 1.0mm, Bayonet Ø 1.0mm, Bayonet
non-stick epistaxis
Serrated Tip

18 19
II II

ACe-Tip™ Non-Stick Forceps


Featuring advanced composition alloy providing non-stick and low temperature technology.
Resulting in minimal adherence of tissue, low absorption, and tissue preservation.

ACBF-010 ACBF-014
Length 8.89cm Length 15.9cm
10mm Ø 0.5mm Ø 0.5mm
10mm
Straight Tip Straight Tip

ACBF-011 ACBF-017
Length 8.89cm Length 17.8cm
8mm 10mm
Ø 0.5mm Ø 1.5mm
Bent Tip Straight Tip

ACBF-012 ACBF-021
Length 11.43cm Length 16.51cm
10mm Ø 0.5mm Ø 1.0mm
10mm
Straight Tip Bayonet
| RF ACCESSORIES | ACe-TipTM Non-Stick Forceps

| RF ACCESSORIES | ACe-TipTM Non-Stick Forceps


Serrated Tip

ACBF-013 ACBF-022
Length 14.0cm Length 18.41cm
10mm
Ø 0.5mm 10mm
Ø 1.0mm
Straight Tip Bayonet Tip

20 *Data on file.
21
FDA Submission Packet 510 (k) K071343
III

RF ELECTRODES Sterile/Single-Use Electrodes


Available for use with the Ellman® family of RF Generators, we Our Sterile/Single-Use RF Electrodes eliminate the risk of cross-contamination, as well as ensuring
provide an a
­ ssortment of reusable and single-use Electrodes in consistent performance and patient confidence. Available in 1.59mm shaft only (25 pcs per Box).
various shapes and sizes.

A2D  Fine Wire Electrode


Length 9,52mm

A3D/OS  Needle Electrode


Length 19.05mm

III A8D  Vari-Tip™ Wire Electrode


Adjustable Cutting Wire

B1D  Round Loop Electrode


Ø 6.35mm

B2D  Round Loop Electrode


Ø 9.53mm

C3D  Diamond Loop Electrode


Ø 4.76mm

D8D  Ball Electrode


Ø 2.3mm

E3D  Scalpel Electrode, Brass


Length 25.4mm, 3.30mm Wide, 0.25mm Thick

E4D  Scalpel Electrode, Brass


Length 12.7mm, 3.30mm Wide, 0.25mm Thick

F1D  Broad Needle Electrode

| RF ELECTRODES | Sterile/Single-Use Electrodes


133D  Niamtu Pin Electrode
Length 3,18mm

About Ellman® Electrodes Medical Electrode Set


The insulated shaft of most INFORMATION Code To Electrode Suffixes: DSEP40
| RF ELECTRODES

Electrodes can be bent or contoured Ordering Electrodes: B- Bendable


to enhance access. D- Disposable (Sterile/Single-Use) Sterile/Single-Use
Code To Electrode Prefixes: Most Electrodes come with 1.59mm shaft size and Assortment of 8 styles
Note: Empire® MicroIncision™ Sterile Needles are
T- Package of 2 pieces some are available with 2.38mm shaft sizes.
not bendable.
X- Package of 5 pieces Use “Q” as a prefix when ordering 2.38mm shaft size,
RF Available in 1.59mm Shaft only
(Not all items available i.e. QTA8B Includes 5 of each Electrode
in 5-packs) Longer Electrode shaft sizes may be available,
(40 pcs per pack)
usually 10.16mm.
A2D, A8D, B1D, B2D, C3D, D8D, E3D, F1D
Please contact us to inquire about available shaft
diameters and Electrode lengths.
22 23
*Electrodes are not true to size
III III

Empire® MicroIncision™ Needles MicroIncision™


Needle Electrodes 3cm TEE301
Length 3cm
Sterile/Single-Use
Deliver focused High Frequency Radiowave energy. Empire® MicroIncision™ Needle Electrodes Straight
Available in 1.59mm
are used for precise cutting and coagulation during Radiosurgical procedures.
Some available in 2.38mm
(2 per pack)
Use “Q” as a Prefix when ordering TEE302
2.38mm Shaft Size Length 4cm
Straight

3cm TEE305
10mm Length 3cm
45° Angle Shaft

TEE307
Magnified view for all Length 3cm
Empire® MicroIncisionTM 45° Angle tip
*Except TEE328 5mm

TEE311
Length 17cm
Straight

10cm
TEE316
Length 10cm
45° Angle Shaft
| RF ELECTRODES | Empire® MicroIncision™ Needles

| RF ELECTRODES | Empire® MicroIncision™ Needles


5cm TEE325
Length 5cm
Curved Shaft

1.9cm TEE327
Length 1.9cm
Straight

2.5cm
TEE328
Length 2.5cm
5m
m 30° Curved Shaft
Longer 5mm Tip

24 25
IV

RF REUSABLE Assorted Needle Electrode Set

ELECTRODES
XA
Includes one each of:
TA1B, TA2B, TA3B, TA9B,
TF1B
Ellman® offers unique bendable Electrodes in different shapes and sizes (5 pcs)
such as the round loop, diamond loop, triangle loop and oval loop to assist
all of your soft-tissue procedures. Commonly used for shaving lesions,
contouring tissue, and biopsying specimens, these RF Electrodes help
ensure consistent performance.

IV TC1B
Diamond Loop 3,18mm Diamond Loop, Fine Wire

Standard Electrodes
Electrodes
Choice of Wire Gauge TC3B
Super Fine - Used when Reusable 4,76mm Diamond Loop, Fine Wire
minimal tissue alteration
is desired. (0.004") 1.59mm or 2.38mm Shaft Size (2 pcs)
Use “Q” as a Prefix when ordering TC6B
Needle Electrodes
Fine - Used when less tissue
alteration is desired (0.007")
2.38mm Shaft Size 7,94mm Diamond Loop, Regular Wire
Regualr - Used to produce
Reusable, 1.59mm or 2.38mm Shaft Size (2 pcs) more coagulation. (0.009")
Diamond Loop Electrodes are TC17B
Use “Q” as a Prefix when ordering 2.38mm Shaft Size
commonly used for one-stroke 6,35mm Diamond Loop, Fine Wire

Needle Electrodes are commonly used for incisions and excisions in precise surgical procedures. Round Loop elliptical incisions.
TC18B
Electrodes are commonly used for shaving lesions, contouring tissue and obtaining biopsy specimens.
6,35mm Diamond Loop, Regular Wire

TA1B
Length 9.53mm, Super Fine Wire
TA2B
Length 9.53mm, Fine Wire Diamond Loop Electrodes Set
TA3B
Length 9.53mm, Regular Needle XCRB
| RF REUSABLE ELECTRODES | Standard Electrodes

| RF REUSABLE ELECTRODES | Standard Electrodes


TA9B Regular Wire
Length 9.53mm, Regular Wire Includes one each of:
TC18B, TC6B
TF1B (2 pcs)
Length 12.7mm, Broad Needle

TF1B/4
Length 10,2mm Broad Needle, Bent Tip
TA8B
Vari-Tip™ Microdissection™
Needle, Fine Wire
Adjustable tip (comes with additional wire & has an adjustable depth)

TA8B/4
Length 10,2mm, Vari-Tip™ Electrode

T133B
Pin Electrode
Length 3.175mm

26 27
*Electrodes are not true to size
IV IV

Triangle Loop TC7B Round Loop TBBB


3.97mm Ø Round Loop, Fine Wire
6.35mm Triangle Loop, Fine Wire
Electrodes Electrodes*
TC8B TB1B
Reusable Reusable
6.35mm Triangle Loop, Regular Wire 6.35mm Ø Round Loop, Fine Wire
1.59mm or 2.38mm Shaft Size 1.59mm or 2.38mm Shaft Size
(2 pcs) TC9B (2 pcs) TB1B/4
Use “Q” as a Prefix when ordering 3.97mm Triangle Loop, Fine Wire Use “Q” as a Prefix when ordering 1/4’’ Ø Round Loop Elec. 4’’ L
2.38mm Shaft Size 2.38mm Shaft Size
TC11B TB4B
Triangle Loop Electrodes 7.54mm Triangle Loop, Fine Wire Round Loop Electrodes are 6.35mm Ø Round Loop, Regular Wire
are commonly used for commonly used for shaving lesions,
TC12B TB4B/4
shaving lesions and contouring tissue and obtaining 1/4’’ Ø Round Loop Elec. 4’’ L
7.54mm Triangle Loop, Regular Wire
contouring tissue. biopsy specimens.
TC14B TB9B
9.53mm Triangle Loop, Regular Wire 7.54mm Ø Round Loop, Fine Wire

TB10B
7.54mm Ø Round Loop, Regular Wire

TB10B/4
19/64’’ Ø Round Loop Elec. 4’’ L

TB2B
Assorted Triangle Loops Electrode Set 9.53mm Ø Round Loop, Fine Wire

XTRB TB5B
9.53mm Ø Round Loop, Regular Wire
Regular Wire
Includes one each of:
TB3B
TC8B, TC12B, TC14B 12.7mm Ø Round Loop, Fine Wire
(3 pcs)
TB6B
12.7mm Ø Round Loop, Regular Wire
| RF REUSABLE ELECTRODES | Standard Electrodes

| RF REUSABLE ELECTRODES | Standard Electrodes


Assorted Round Loop Electrode Set Assorted Round Loop Electrode Set

XBRB XB
Regular Wire (Formerly XBFB)
Includes one each of: Fine Wire
TB6B, TB5B, TB10B, Includes one each of:
TB4B, TBBB TB3B, TB2B, TB9B, TB1B, TBBB
(5 pcs) (5 pcs)

28 *Electrodes are not true to size 29


IV IV

Ball Electrodes TD3B Scalpel Electrodes TE1B


2mm Ball 4,76mm Scalpel, 45° Angle
Reusable Reusable
1.59mm or 2.38mm Shaft Size TD8B 1.59mm or 2.38mm Shaft Size TE2B
(2 pcs) 2.36mm Ball (2 pcs) 9,53mm Scalpel
Use “Q” as a prefix when ordering TD9B Use “Q” as a Prefix when ordering
2.38mm Shaft Size 2.38mm Shaft Size TE3B
3.17mm Ball
25,4mm Scalpel
TD10B Scalpel Electrodes are commonly used
Ball Electrodes are commonly
4.34mm Ball for incisions and excision of tissue. The blade shape
used for coagulation.
provides broader coagulation than a needle Electrode.
TD11B
4.75mm Ball

Assorted Ball Electrode Set Empire® MicroTip Electrodes* TEE227


Empire® MicroTip Needles
Reusable one .010” wire
XD 2mm Exposed Tip
Includes one each of: one .020” wire
(2 pcs, one of each) Insulated Coated
TD11B, TD10B, TD9B,
TD8B, TD3B 2m
m
(Clear Teflon)
(5 pcs) Empire® MicroTip Needles are tapered and have a Needle Set;
pinpoint design which produces micro-smooth cutting 2mm Exposed Tips
and coagulation while creating less tissue alteration.

Insulated Electrodes

| RF REUSABLE ELECTRODES | Standard Electrodes & Insulated Electrodes


Oval Loop Electrodes TP1B
3,97mm Oval Loop, Fine Wire
Reusable
TP2B
1.59mm or 2,38mm Shaft Size
3,97mm Oval Loop, Regular Wire
Insulated Needle D6A
(2 pcs) Insulated Coated Needle
Use “Q” as a prefix when ordering Electrodes 0.004” Super Fine, White, (1 pc)
TP3B
| RF REUSABLE ELECTRODES | Standard Electrodes

2,38mm Shaft Size 6,35mm Oval Loop, Fine Wire Reusable


D6B
1/2 mm Exposed Tip
Insulated Coated Needle
Oval Loop Electrodes are commonly TP4B Insulated Needle
0.5mm 0.007” Fine, Purple, (1 pc)
used for shaving lesions and 6,35mm Oval Loop, Regular Wire
contouring tissue. Electrodes are used for the D6C
TP5B
treatment of Telangiectasia Insulated Coated Needle
7,54mm Oval Loop, Fine Wire
and for epilation. 0.009” Regular, Orange, (1 pc)
TP6B
7,54mm Oval Loop, Regular Wire

TP7B
9,53mm Oval Loop, Fine Wire

TP8B
Insulated Needle Electrodes Set
9,53mm Oval Loop, Regular Wire
D7
TP10B Includes one each of:
12,7mm Oval Loop, Regular Wire D6A, D6B, D6C
(3 pcs)

30 *Electrodes are not true to size 31


IV IV

ACe-Tip™ Advanced Reusable Electrode Sets


Composition Alloy Standard Electrode Sets
S10B
The Ellman® ACe-Tip™ Electrodes are designed to reduce resistance impedance which causes less undesired lateral Reusable
heat compared to tungsten steel Electrodes and 45% reduction in the zone of hyalinization has been demonstrated. 1.5875mm or 2.38125mm shaft size Use “Q”
ACe-Tip™ Electrodes glide smoothly through tissues and are excellent for sculpting and tissue shaping. As a prefix when ordering 2.38125mm Shaft Size
Includes one of each Electrode: TC7B, TB1B,
TC3B, TA3B, TD8B, TF1B, A8B
(7 pcs)
TNAEE287
1cm Needle, 76.2mm Curved Sleeve ACe-TipTM
1.59mm Shaft (2 pcs)

TNAB1B
6.35mm Round Loop
Standard Electrode Sets
ACe-TipTM Fine Wire 1.59mm Shaft (2 pcs)

TNAB4B S10B/4 4”
6.35mm Round Loop Includes one of each Electrode:
ACe-TipTM Regular Wire 1.59mm Shaft (2 pcs)
| RF REUSABLE ELECTRODES | ACe-TIP™ Advanced Composition Alloy & Specialty Electrodes

TA8B/4”, TC3B/4”, TC7B/4”,


TD8B/4”
TNAA8B
(4 pcs)
Vari-Tip™
ACe-Tip™ 1.59mm Shaft (2 pcs)
(comes with additional wire and has an adjustable depth)

TNAEE305
Empire® MicroIncision™
Needle ACe-Tip™ 1.59mm Shaft (2 pcs)

TNAEE330 Standard Electrode Sets


Chedly Punctal Occlusion (CPO) Electrode
Needle ACe-Tip™, 1.59mm Shaft (2 pcs) S12B

| RF REUSABLE ELECTRODES | Reusable Electrode Sets


Includes 1 of each Electrode:
TF1B, TA2B, TA3B, TC3B, TD8B,
TBBT, TB1B, TA8B
(8 pcs)

Specialty Electrodes
Rhinophyma Electrode | Mucotome Electrodes* Set Standard Electrode Sets
EE234 S13B
Reusable Includes 1 of each Electrode:
Rhinophyma Electrode Set TF1B, TA2B, TA3B, TC3B, TD8B,
Set of 3 pcs, one of each TB2B, TA8B, TD8B/4
EE233, EE232, EE231 (8 pcs)
(5 pcs)

32 33
*Electrodes are not true to size
V

ACCESSORIES Miscellaneous
With the surgical cart, your on the go storage set up is designed to provide
a stress-free work environment with all your tools close and organized. Our
Electrode Protector Stand™
carts are on wheels for easy mobility from room to room. They also feature Protects your Electrodes from damage and breakage during the sterilization process.
shelves to hold accessories with a gooseneck arm for suction flexibility. It will stand on any flat surface for easy identification and access to each Electrode.

Adjustable

Surgical Cart H66


Electrode Protector Stand™
For regular 2” Standard Electrodes
Holds 12 Electrodes
H157 Cart ( 6 x 1.59mm and 6 x 2.38mm)
(1 pc)

Electrodes not included

H157
The elegantly designed H157 Cart
includes 2 shelves for accessories,
a gooseneck flexible arm and a
convenient front handle for micro
positioning. Electrode Block
Four rugged caster wheels ensure
easy mobility from room to room.
H1
(Shown with Dual RF™ 120, Electrode Block
Surg-e®-Vac™ and Accessories - Holds 18 Electrodes (1.59mm)

| ACCESSORIES | Miscellaneous
| ACCESSORIES | Surgical Carts

Not included). Also compatible with (1 pc)


Pellevé® S5 Generator.
Electrodes not included

NOTE: H157 Cart not compatible with AcuSect®, RadioLase or EMC Generators.

34 35
VI

MULTI-SPECIALTY Insulated Matrixectomy Electrode Set

ACCESSORIES
H9
Reusable
Set of 3 Electrodes
1.59 or 2.38mm Shaft
Matrixectomy Electrode Set
Includes one each of: H10D & H10E

VI
Otorhinolaryngology
The Bayonet Turbinate

Family Practice/Podiatry Electrode and Bipolar Handpiece design includes a pencil grip for easy handling with a bayonet design for easy
intranasal visualization during surgery.

The Ellman® Radiosurgical nail matrixectomy technique for Ingrown Toenail allows the matrix to be destroyed
Bayonet RF Turbinate Volume Reduction Electrode™
electrically with a teflon coated Electrode, which protects the overlying eponychium.

IEC-I6D
Patented Dr. Constantin Stan Monopolar Forceps I ~2.4cm I ~1.9cm I
For Surgitron® Dual RF™, S5, AcuSect®and

| MULTI-SPECIALTY ACCESSORIES | Family Practice/Podiatry | Otorhinolaryngology


The Ellman® Micro, Mini and Mono Stan Forceps simultaneously dissect and coagulate tissues using the 4.0 MHz RadioLase® Devices
Radiofrequency. The inside of tips on the Mini Mono and Mono Stan Forceps are serrated.
I6/JXE
For EMC Device
Micro Stan RF™ Forceps IEC-MJ21
Reusable, Suggested for Blepharoplasty and Facelift
Procedures IEC/I6D/L
8.89cm Length For Surgitron® Dual RF™, S5, AcuSect® and
| MULTI-SPECIALTY ACCESSORIES | Family Practice/Podiatry

not illustrated

Includes Quick-Connect™ Cable and Video CD RadioLase® Devices


For use with Surgitron® Dual RF™ and Pellevé® S5 Devices

Mini Mono Stan RF™ Forceps IEC-MJ11/M RAUP Electrode H81A1


Reusable, Monopolar Forceps with Cutting, Sterile/Single-Use
Coagulation, Irrigation and Suction Port RAUP Radiosurgically Assisted
Suggested for Facelifts Uvulopalatoplasty
12.38cm Length (2 pcs)
Includes Quick-Connect™ Cable and Video CD
For use with Surgitron® Dual RF™and Pellevé® S5 Devices

Mono Stan RF™ Forceps IEC-MJ11 Sub-Mucosal VTR (UPP) Electrode TEE229A
Reusable, Monopolar Forceps with Cutting, Sterile/Single-Use
Coagulation, Irrigation and Suction Port For Volumetric Reduction of Redundant
Suggested for Breast Augmentation Procedures Tissue 1cm Insulated, 1 cm Exposed
15.56cm Length (2 pcs)
Includes Quick-Connect™ Cable and Video CD
For use with Surgitron® Dual RF™ and Pellevé® S5 Devices I 1cm I 1cm I

36 *Electrodes are not true to size 37


VI VI

Tongue Base Reduction Electrode Suction Coagulation Tubes


For precise coagulation in wet-field environments where suction is required to aid in
TEE605 visualization
Sterile/Single-Use
For Volumetric
Reduction of Redundant Tissue
I 1cm I 1cm I 1cm I
(2 pcs) H45  Suction Tube
15.24cm Long, 2.38mm Orifice

H46  Suction Tube


15.24cm Long, 3.18mm Orifice

H47  Suction Tube


3-3/4" Long, 1/16" Orifice
HLTZ Tonsillotomy Electrode
H48  Suction Tube
3-3/4" Long, 2.38mm Orifice
TEE284
(2 pcs)
| MULTI-SPECIALTY ACCESSORIES | Family Practice/Podiatry | Otorhinolaryngology

| MULTI-SPECIALTY ACCESSORIES | Family Practice/Podiatry | Otorhinolaryngology


The Micro-Larynx Suction Coagulation End Connecter
Probe allows quick and efficient coagulation and can be used for
Granulomas, Papillomatosis, Cyst Biopsies, Vocal Cord Polyps,
Posterior Cordectomy, Glottic and Sub-glottic Angiomas, Laryngeal
H43
Tumor and Laryngeal Biopsies.

Micro-Larynx™ RF Probes

IEC-EE275A
Reusable
For Surgitron® Dual RF™, Pellevé® S5,
AcuSect® and RadioLase® Devices
1.59mm Shaft, 240mm Long
(3 pcs)

38 *Electrodes are not true to size 39


VI VI

Suction Adenoid Probes Set


Gynecology
Reusable
LLETZ Bayonet Electrodes
Set of 3 Probes, Quick-Connect™ Cable
and Cleaning Brush
W32  Reusable
Bayonet, 25mm Loop (1 pc)
Small 9mm with Quick-Connect™ Cable
Med 15mm with Quick-Connect™ Cable W32D  Sterile/Single-Use (5 pcs)
Large 19mm with Quick-Connect™ Cable
W31 Reusable
Bayonet, 20mm Loop (1 pc)

W31D  Sterile/Single-Use (5 pcs)

W30 Reusable
Bayonet, 25mm Loop (1 pc)

W30D  Sterile/Single-Use (5 pcs)

W34 Reusable
Bayonette, 5mm Ball (1 pc)
RF Assisted Tonsillotomy (Rat) Ball Electrodes W34D  Sterile/Single-Use (5 pcs)
An advancement over the traditional tonsillotomy. The RAT Electrodes permit
| MULTI-SPECIALTY ACCESSORIES | Family Practice/Podiatry | Otorhinolaryngology

controlled reduction of the tonsil without excessive thermal damage or blood loss. W33D  Sterile/Single-Use (5 pcs)

EE264
Set of 3
Reusable, 1.59mm Shaft LLETZ Bayonet Electrode Set
TEE261, TEE262, TEE263
INSULATED NECK W35 
LLETZ Bayonet Electrode Set Reusable (5 pcs) not illustrated

Use “D” as a suffix when ordering Sterile/Single-Use

| MULTI-SPECIALTY ACCESSORIES | Gynecology


TEE263
3.17mm Ball, 10.16mm Long
(2 pcs)

External Genital Lesion RF Electrodes


W18  Reusable
90mm Length, 5mm Ball

40 41
VI VI

The Ellman® LLetz Loop Electrodes Standard Electrode Set


are used for the diagnosis and treatment of cervical
intraepithelial neoplasia (CIN) and dysplasia. S10B/4
10.16cm Shaft Length
(4pcs)
W1  15mm x 10mm Loop, Reusable (1 pc)
W1D 15mm x 10mm Loop, Sterile/Single-Use (5 pcs)
S10B/4 4”
include one of each
W2  20mm x 10mm Loop, Reusable (1 pc)
electrode of: A8B/4”,
W2D 20mm x 10mm Loop, Sterile/Single-Use (5 pcs)
C3B/4”, C7B/4”, D8B/4”
W3  25mm x 10mm Loop, Reusable (1 pc)
W3D 25mm x 10mm Loop, Sterile/Single-Use (5 pcs)

F2  Endo-Cervical Box 8mm x 11mm Box, Reusable (1 pc)


F2D  Endo-Cervical Box 8mm x 11mm Box,
Sterile/Single-Use (5 pcs) Ophthalmology / Oculoplastics
W18  5mm Ball, Reusable (1 pc)
W18D  5mm Ball, Sterile/Single-Use (5 pcs) Ophthalmic Micro-Dissection Electrodes™

TA10/C1
The Ellman® LLetz Loop Electrodes Set Reusable. 2" Electrodes
1.5mm of active 10.16cm Wire (2 pcs)

| MULTI-SPECIALTY ACCESSORIES | Gynecology | Ophthalmology/Oculoplastics


W4

m
5m
TA10/C2

1.
Includes 1 of each in 5 Styles, Reusable:
Reusable. 2" Electrodes
W1, W2, W3, F2, W18
3.0mm of active 10.16cm Wire (2 pcs)
(5 pcs)

m
3m
Available in 1.59mm or 2.38mm
Use “Q” as a prefix when ordering 2.38mm shaft size
Use “D” as a suffix when ordering Sterile/Single-Use Ophthalmic Micro-Dissection Electrodes™ Set
Versions of the LLETZ Loop Electrodes.
A10
| MULTI-SPECIALTY ACCESSORIES | Gynecology

Reusable
Set of two (TA10/C1 and TA10/C2 1.5mm and 3.0mm, 10.16cm Wire - one of each) not illustrated

Conization Electrode Chedly Punctal Occlusion (CPO) Electrode


Reusable The Chedly Punctal Occlusion Electrode dilates the punctum and is then activated
G1  Conization Electrode
to coagulate the tissues to occlude the punctual opening.

G1/4  10.16cm Long, Rotated at 360° to provide a TNAEE330


not illustrated
cone Shaped Specimen Reusable set of two ACe-Tip™ Electrodes
m
4m

42 43
VI VI

Plastic Surgery Pellevé® Wrinkle Reduction


The Ellman® Cosmetic Treatment System
Cosmetic Treatment Package Package

is an effective, comfortable way to remove small


MicroInsulated Needle
Handpiece
GlideSafe® Handpieces
unsightly facial “spider veins” with minimal recovery 50 MicroInsulated Easily maneuver over contours of the face to gently heat the skin to
Sterile Needles
time, minimal scarring and immediate improvement stimulate new collagen growth and reduce wrinkles.
in appearance. 50 Patient Education
Brochures

P275HPD 
Cosmetic Treatment Package Pellevé® GlideSafe® 7.5mm Handpiece & Cable

For treating telangiectasia and epilation of hair follicles

P275HPD1
H135A
Pellevé® GlideSafe® 7.5mm Handpiece (1pc)
For EMC Device
IEC-H135A
For S5, Surgitron® Dual RF™, AcuSect® and RadioLase® Devices P210HPD 
Pellevé® GlideSafe® 10mm Handpiece & Cable
Package Includes:
One MicroInsulated Needle Handpiece, 50 MicroInsulated Sterile Needles and 50 Patient Education Brochures
XH136 P210HPD1
MicroInsulated Needle Handpiece™ for EMC Device (2 pcs) Pellevé® GlideSafe® 10mm Handpiece (1pc)

IEC-XH136
MicroInsulated Needle Handpiece™ For S5, Surgitron® Dual RF™, AcuSect® and RadioLase® Devices (2 pcs) P215HPD 
H137 Pellevé® GlideSafe® 15mm Handpiece & Cable

| MULTI-SPECIALTY ACCESSORIES | Pellevé® Wrinkle Reduction System


MicroInsulated Sterile Needles (50 pcs)
P215HPD1
Pellevé® GlideSafe® 15mm Handpiece (1pc)

Dermatology Electrode Assortment Set


P220HPD 
| MULTI-SPECIALTY ACCESSORIES | Plastic Surgery

DDERM40 D8D (15 pcs) Pellevé® GlideSafe® 20mm Handpiece & Cable

Assorted
B1D (5 pcs)
Sterile/Single-Use Electrodes P220HPD1
1.59mm Shaft not illustrated F1D (15 pcs) Pellevé® GlideSafe® 20mm Handpiece (1pc)
(4 Electrode Styles)
A8D (5 pcs)

GlideSafe® Handpieces Vari-Pak

P2VPHPD not illustrated

MicroInsulated Sterile Needles Vari-Pack 10mm, 15mm & 20mm

H137  (50 pcs)

Magnified view of MicroInsulated Needle

44 45
VI VI

PelleFirm® RF Body Treatment Miscellaneous


Deeply heats tissue and reduces the appearance of cellulite.
Pellevé® Quick-Connect Cable
P2CBD
25 mm P325PFHP  2m, for use with GlideSafe®
Pellevé® RF Handpiece, 25mm (Box of 3) Handpieces
(6 pcs)

P325PFHP1 
Pellevé® (1) 25mm Handpiece

P325PFHPU  Pellevé® Treatment


Pellevé® RF Handpiece
03-08
P325PFMH  Gel, 8 oz
| MULTI-SPECIALTY ACCESSORIES | Pellevé® Wrinkle Reduction System | PelleFirm® RF Body Treatment

Pellevé® Massage Head, 25mm (Box of 1)

Pellevé® GlideSafe® Acc Pack


P330PFHP  not illustrated PGACCPK
30 mm
Pellevé® RF Handpiece, 30mm (Box of 3)

P330PFHP1 
Pellevé® (1) 30mm Handpiece
Pellevé® Body Package Accessory
P330PFHPU  not illustrated PM2BODY
Pellevé® RF Handpiece

P330PFMH 

| MULTI-SPECIALTY ACCESSORIES | Miscellaneous


Pellevé® Massage Head, 30mm (Box of 1)
Pellevé® Face Package Accessory
not illustrated PM2FACE

Pellevé® Vari-Pak Pellevé® Surg Acc Pack


not illustrated PM2SURG
P3PFVP-WMH 
not illustrated
2 Handpiece & 2 Heads

Pellevé® S5 (M2) Transport Black Case


not illustrated PVS5CASE

46 47
European Offices:

Cynosure Germany
Robert-Bosch-Strasse 11A | 63225 Langen | +49 6103 20 11 10

Cynosure Spain
Avenida Quitapesares | 1728670 Villapark Villaviciosa de Odón (Madrid) | +34 917 888 700

Cynosure France
Bâtiment 6 | 132-134 Bd de Verdun | 92400 Courbevoie | +33 1 46 67 22 50

Cynosure UK
The Old Barn Offices Lower Mount Farm | Cookham SL6 9EE | +44 1628 522252

[email protected]

You might also like