0% found this document useful (0 votes)
2K views11 pages

CSU602A Centralized System Management Unit Product Description V1.0 - 20210202 - EN

The document provides an overview and description of the CSU602A Centralized System Management Unit and its product architecture. Some key points: - The CSU602A is an advanced digital controlling and management unit that can manage telecom power systems, including grid power, solar power, batteries, air conditioning and site environment/security. - It has various interfaces for remote management via protocols like TCP/IP, GPRS/3G/4G and supports collecting real-time operation data, detecting system status, and receiving instructions from a network management center. - The product architecture includes the CSU602A management unit, UIB board for input/output, and optional sensors. The CSU602

Uploaded by

Victor Artica
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views11 pages

CSU602A Centralized System Management Unit Product Description V1.0 - 20210202 - EN

The document provides an overview and description of the CSU602A Centralized System Management Unit and its product architecture. Some key points: - The CSU602A is an advanced digital controlling and management unit that can manage telecom power systems, including grid power, solar power, batteries, air conditioning and site environment/security. - It has various interfaces for remote management via protocols like TCP/IP, GPRS/3G/4G and supports collecting real-time operation data, detecting system status, and receiving instructions from a network management center. - The product architecture includes the CSU602A management unit, UIB board for input/output, and optional sensors. The CSU602

Uploaded by

Victor Artica
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

CSU602A Centralized System

Management Unit Product


Description
CSU602A Centralized System Management Unit Product Description

CSU602A Centralized System Management Unit Product


Description
Version Date Author Reviewer Notes

V1.0 ZTE Not open to the third party

© 2022 ZTE Corporation. All rights reserved.


ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used
without the prior written permission of ZTE.
Due to update and improvement of ZTE products and technologies, information in this document is subjected to
change without notice.

Information Classification Level: Confidential▲

© 2022 ZTE. All rights reserved. Confidential▲ 1


CSU602A Centralized System Management Unit Product Description

TABLE OF CONTENTS

1 Overview...........................................................................................................................................4

2 Function........................................................................................................................................... 4

3 Product Architecture.....................................................................................................................5

4 Interface Description.....................................................................................................................6
4.1 CSU602A....................................................................................................................................... 6
4.2 UIB Board.......................................................................................................................................7

5 Technical Description................................................................................................................... 9

2 © 2022 ZTE. All rights reserved. Confidential▲


CSU602A Centralized System Management Unit Product Description

FIGURES

Figure 1- 1 Appearance of CSU602A.............................................................................................. 4


Figure 3- 1 Product architecture of CSU602A&UIB.......................................................................5
Figure 4- 1 Interfaces of CSU602A.................................................................................................. 6
Figure 4- 2 Interfaces of UIB..............................................................................................................7

TABLES

Table 4- 1 Signal Interfaces of CSU602A........................................................................................7


Table 4- 2 Signal Interfaces of UIB...................................................................................................7
Table 5- 1 Technical Parameters of CSU602A&UIB..................................................................... 9

© 2022 ZTE. All rights reserved. Confidential▲ 3


CSU602A Centralized System Management Unit Product Description

1 Overview
The Centralized System Management Unit CSU602A is an advanced digital controlling
and management unit for telecom power system. This management unit can manage
ZTE super high efficiency rectifier and solar PU. Through its rich data interfaces and
powerful data processing function, it can manage the grid power, solar power, DG,
battery, air-conditioner, security and site environment conditions in real time to ensure
the stable power supply and site operation.

Besides these, CSU also can provide multiple communication interfaces such as RS232,
RS485 and RJ45, and supports TCP/IP, GPRS/3G/4G and other networking modes for
remote management function.

Figure 1- 1 Appearance of CSU602A

2 Function
 Management

 Manages intelligent SmartLi for flexible applications, including, SmartLi and


VRLA battery hybrid use, battery anti-theft and voltage boosting for remote
power supply.

 Provides battery set discharging, charging, and test management.

 Controls the automatic sleep function of rectifiers to save energy.

 Supports the export of historical records to a USB flash drive.

 Supports data query, parameter configuration, and system control on the LCD
screen through operations on keys.

4 © 2022 ZTE. All rights reserved. Confidential▲


CSU602A Centralized System Management Unit Product Description

 Supports user permission configuration.

 Alarms

The CSU raises an alarm and provides protection when the power system is faulty.

 Maintenance Management

Supports parameter setting, exporting history records, and upgrading program in batch
through a USB flash disk.

 System Upgrade

The CSU supports system upgrade through a USB flash drive or the Web page.

 Detection

 The CSU collects the operation data of the power system in real time, and detects
the operational status of the power system.

 The CSU reports data to and receives instructions from the network management
center to detect the power system remotely.

 Web Access

After the CSU is connected to the network, the Chrome browser can be used to access
the CSU to remotely query real-time data and status, obtain alarm information, start or
stop the device, and charge or discharge the device.

3 Product Architecture
The following figure shows the architecture of CSU602A. CSU602A&UIB is basic unit for
the whole power system centralized detection and management, and SWCU is functional
unit for GPRS/3G/4G wireless networking. Moreover, there are many sensors accessed
for option, such as fuel level sensor, energy meter, flood, humidity, smoke, etc.

Figure 3- 1 Product architecture of CSU602A&UIB

© 2022 ZTE. All rights reserved. Confidential▲ 5


CSU602A Centralized System Management Unit Product Description

4 Interface Description

4.1 CSU602A

The external front view of CSU602A is shown by following figure.

Figure 4- 1 Interfaces of CSU602A

1. FE interface 2. USB interface 3. LCD displays

4. Keys 5. Wrench 6. Indicators

6 © 2022 ZTE. All rights reserved. Confidential▲


CSU602A Centralized System Management Unit Product Description

Table 4- 1 Signal Interfaces of CSU602A


Interface Function

Supports HTTPS, SNMP, and YD/T 1104 (customized for


RJ45 Ethernet
ZTE's wireless products).
Supports a USB only, and does not identify any SD card,
mobile hard disk, MP3, MP4, or other pluggable storage
USB interface
devices.
The file system of the USB flash drive must be FAT.

4.2 UIB Board

The UIB provides input/output relays, environment detection interfaces, and


communication interfaces.

Figure 4- 2 Interfaces of UIB

Table 4- 2 Signal Interfaces of UIB


Silk Screen Interface Function

Input and Output Relay Interface

© 2022 ZTE. All rights reserved. Confidential▲ 7


CSU602A Centralized System Management Unit Product Description

The users can set the alarms for the input dry
Input RLY
Input relays (dry contacts1-8 in the CSU.
1, 2, 3, 4, 5, 6, 7,
contacts) The users can query the status of the input relays
8
through the CSU.
Output RLY The users can customize the output relays 1-8 in the
Output relays
1, 2, 3, 4, 5, 6, 7, CSU. The users can query the status of the output
(dry contacts)
8 relays through the CSU.

Communication Interfaces
RS232/RS485 Northbound RS232/RS485 multiplex interface for
RS232(RS485-2) multiplex serial-port communication. Port switchover is
interface implemented through a DIP switch inside the UIB.

RS485-1 RS485 serial port RS485 port for RS485 serial-port communication.

Multiplexing
Used for RS485 communication.
RS485
RS232 cannot be used simultaneously.
communication
Environment Detection Interfaces
Temperature
TEMP1 detection Connected to the temperature sensor for battery set 1.
interface 1

Temperature
TEMP2 detection Connected to the temperature sensor for battery set 2.
interface 2

Temperature
TEMP3 detection Connected to the temperature sensor for battery set 3.
interface 3

Temperature
Connected to the environment temperature sensor or
ENVTEMP detection
the temperature sensor for battery set 4.
interface
Door access
Connected to the door entry sensor to detect whether
Door detection
the cabinet door is open.
interface
Water logging
Connected to the water logging sensor to detect
Flood detection
whether the cabinet is flooded with water.
interface
Humidity
Humidity detection Connected to the humidity sensor.
interface

8 © 2022 ZTE. All rights reserved. Confidential▲


CSU602A Centralized System Management Unit Product Description

Smog detection
Smoke Connected to the smog sensor.
interface

5 Technical Description
Table 5- 1 Technical Parameters of CSU602A&UIB
Parameters Description

Working Conditions

Operation temperature -40°C to 70°C

Storage temperature -40°C to 85°C

Relative humidity 5%~95%

Cooling solution Natural cooling

Altitude ≤3000m is recommended.

Environment protection IP 20

Physical Characteristics

CSU Dimension 40.8mm *84.5mm * 217.5mm (H * W * D)

CSU Weight 620g


CSU Power Loss Less than 8W

Communication Interface RS232/RS485/FE/USB


8 interfaces:
4 for battery/ambient temperature(configurable), 1
Environment Interface
for door magnetic, 1 for humidity(optional), 1 for
flooding(optional) and 1 for smoke(optional)

Relays Interface 8 for output relays, 8 for input relays

4 for battery mid-voltage, multiplexing with 4


Extension Interface
input relays 5, 6, 7, 8

Others

Safety Certification IEC 60950

EMS IEC 61000

MTBF ≥5*105 h