CSU602A Centralized System
Management Unit Product
Description
CSU602A Centralized System Management Unit Product Description
CSU602A Centralized System Management Unit Product
Description
Version Date Author Reviewer Notes
V1.0 ZTE Not open to the third party
© 2022 ZTE Corporation. All rights reserved.
ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be disclosed or used
without the prior written permission of ZTE.
Due to update and improvement of ZTE products and technologies, information in this document is subjected to
change without notice.
Information Classification Level: Confidential▲
© 2022 ZTE. All rights reserved. Confidential▲ 1
CSU602A Centralized System Management Unit Product Description
TABLE OF CONTENTS
1 Overview...........................................................................................................................................4
2 Function........................................................................................................................................... 4
3 Product Architecture.....................................................................................................................5
4 Interface Description.....................................................................................................................6
4.1 CSU602A....................................................................................................................................... 6
4.2 UIB Board.......................................................................................................................................7
5 Technical Description................................................................................................................... 9
2 © 2022 ZTE. All rights reserved. Confidential▲
CSU602A Centralized System Management Unit Product Description
FIGURES
Figure 1- 1 Appearance of CSU602A.............................................................................................. 4
Figure 3- 1 Product architecture of CSU602A&UIB.......................................................................5
Figure 4- 1 Interfaces of CSU602A.................................................................................................. 6
Figure 4- 2 Interfaces of UIB..............................................................................................................7
TABLES
Table 4- 1 Signal Interfaces of CSU602A........................................................................................7
Table 4- 2 Signal Interfaces of UIB...................................................................................................7
Table 5- 1 Technical Parameters of CSU602A&UIB..................................................................... 9
© 2022 ZTE. All rights reserved. Confidential▲ 3
CSU602A Centralized System Management Unit Product Description
1 Overview
The Centralized System Management Unit CSU602A is an advanced digital controlling
and management unit for telecom power system. This management unit can manage
ZTE super high efficiency rectifier and solar PU. Through its rich data interfaces and
powerful data processing function, it can manage the grid power, solar power, DG,
battery, air-conditioner, security and site environment conditions in real time to ensure
the stable power supply and site operation.
Besides these, CSU also can provide multiple communication interfaces such as RS232,
RS485 and RJ45, and supports TCP/IP, GPRS/3G/4G and other networking modes for
remote management function.
Figure 1- 1 Appearance of CSU602A
2 Function
Management
Manages intelligent SmartLi for flexible applications, including, SmartLi and
VRLA battery hybrid use, battery anti-theft and voltage boosting for remote
power supply.
Provides battery set discharging, charging, and test management.
Controls the automatic sleep function of rectifiers to save energy.
Supports the export of historical records to a USB flash drive.
Supports data query, parameter configuration, and system control on the LCD
screen through operations on keys.
4 © 2022 ZTE. All rights reserved. Confidential▲
CSU602A Centralized System Management Unit Product Description
Supports user permission configuration.
Alarms
The CSU raises an alarm and provides protection when the power system is faulty.
Maintenance Management
Supports parameter setting, exporting history records, and upgrading program in batch
through a USB flash disk.
System Upgrade
The CSU supports system upgrade through a USB flash drive or the Web page.
Detection
The CSU collects the operation data of the power system in real time, and detects
the operational status of the power system.
The CSU reports data to and receives instructions from the network management
center to detect the power system remotely.
Web Access
After the CSU is connected to the network, the Chrome browser can be used to access
the CSU to remotely query real-time data and status, obtain alarm information, start or
stop the device, and charge or discharge the device.
3 Product Architecture
The following figure shows the architecture of CSU602A. CSU602A&UIB is basic unit for
the whole power system centralized detection and management, and SWCU is functional
unit for GPRS/3G/4G wireless networking. Moreover, there are many sensors accessed
for option, such as fuel level sensor, energy meter, flood, humidity, smoke, etc.
Figure 3- 1 Product architecture of CSU602A&UIB
© 2022 ZTE. All rights reserved. Confidential▲ 5
CSU602A Centralized System Management Unit Product Description
4 Interface Description
4.1 CSU602A
The external front view of CSU602A is shown by following figure.
Figure 4- 1 Interfaces of CSU602A
1. FE interface 2. USB interface 3. LCD displays
4. Keys 5. Wrench 6. Indicators
6 © 2022 ZTE. All rights reserved. Confidential▲
CSU602A Centralized System Management Unit Product Description
Table 4- 1 Signal Interfaces of CSU602A
Interface Function
Supports HTTPS, SNMP, and YD/T 1104 (customized for
RJ45 Ethernet
ZTE's wireless products).
Supports a USB only, and does not identify any SD card,
mobile hard disk, MP3, MP4, or other pluggable storage
USB interface
devices.
The file system of the USB flash drive must be FAT.
4.2 UIB Board
The UIB provides input/output relays, environment detection interfaces, and
communication interfaces.
Figure 4- 2 Interfaces of UIB
Table 4- 2 Signal Interfaces of UIB
Silk Screen Interface Function
Input and Output Relay Interface
© 2022 ZTE. All rights reserved. Confidential▲ 7
CSU602A Centralized System Management Unit Product Description
The users can set the alarms for the input dry
Input RLY
Input relays (dry contacts1-8 in the CSU.
1, 2, 3, 4, 5, 6, 7,
contacts) The users can query the status of the input relays
8
through the CSU.
Output RLY The users can customize the output relays 1-8 in the
Output relays
1, 2, 3, 4, 5, 6, 7, CSU. The users can query the status of the output
(dry contacts)
8 relays through the CSU.
Communication Interfaces
RS232/RS485 Northbound RS232/RS485 multiplex interface for
RS232(RS485-2) multiplex serial-port communication. Port switchover is
interface implemented through a DIP switch inside the UIB.
RS485-1 RS485 serial port RS485 port for RS485 serial-port communication.
Multiplexing
Used for RS485 communication.
RS485
RS232 cannot be used simultaneously.
communication
Environment Detection Interfaces
Temperature
TEMP1 detection Connected to the temperature sensor for battery set 1.
interface 1
Temperature
TEMP2 detection Connected to the temperature sensor for battery set 2.
interface 2
Temperature
TEMP3 detection Connected to the temperature sensor for battery set 3.
interface 3
Temperature
Connected to the environment temperature sensor or
ENVTEMP detection
the temperature sensor for battery set 4.
interface
Door access
Connected to the door entry sensor to detect whether
Door detection
the cabinet door is open.
interface
Water logging
Connected to the water logging sensor to detect
Flood detection
whether the cabinet is flooded with water.
interface
Humidity
Humidity detection Connected to the humidity sensor.
interface
8 © 2022 ZTE. All rights reserved. Confidential▲
CSU602A Centralized System Management Unit Product Description
Smog detection
Smoke Connected to the smog sensor.
interface
5 Technical Description
Table 5- 1 Technical Parameters of CSU602A&UIB
Parameters Description
Working Conditions
Operation temperature -40°C to 70°C
Storage temperature -40°C to 85°C
Relative humidity 5%~95%
Cooling solution Natural cooling
Altitude ≤3000m is recommended.
Environment protection IP 20
Physical Characteristics
CSU Dimension 40.8mm *84.5mm * 217.5mm (H * W * D)
CSU Weight 620g
CSU Power Loss Less than 8W
Communication Interface RS232/RS485/FE/USB
8 interfaces:
4 for battery/ambient temperature(configurable), 1
Environment Interface
for door magnetic, 1 for humidity(optional), 1 for
flooding(optional) and 1 for smoke(optional)
Relays Interface 8 for output relays, 8 for input relays
4 for battery mid-voltage, multiplexing with 4
Extension Interface
input relays 5, 6, 7, 8
Others
Safety Certification IEC 60950
EMS IEC 61000
MTBF ≥5*105 h
© 2022 ZTE. All rights reserved. Confidential▲ 9