Optimo GE en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 55

Stoneridge Optimo² Manual

Stoneridge Electronics Ltd


Copyright

The information contained in this document is the property of Stoneridge


Electronics Ltd. and should not be reproduced, revealed or appropriated,
either in whole or in part, without the written authority of Stoneridge, Inc.

DD 56065 Rev 08 1 © Stoneridge Electronics Ltd


Contents
1. Optimo² Kit .................................................................................................................................................................................... 3
2. Optimo² Switching On ................................................................................................................................................................... 3
3. Optimo² Main Screen .................................................................................................................................................................... 4
4. Optimo² Features .......................................................................................................................................................................... 4
5. Optimo² Sleep Mode & Switching Off ........................................................................................................................................... 5
6. Getting Started .............................................................................................................................................................................. 6
6.1. Task Bar Icons .................................................................................................................................................................... 6
6.1.1. Workshop Settings .................................................................................................................................................... 6
6.1.2. Connecting to Wi-Fi .................................................................................................................................................. 8
6.1.3. Wireless Connections ............................................................................................................................................... 8
6.2. Connecting to the Tachograph ........................................................................................................................................... 9
6.3. Calibrating and Programming ............................................................................................................................................ 9
7. Optimo² – MKIII Programmer – Main screens ............................................................................................................................ 10
7.1. Read and modify data ...................................................................................................................................................... 11
7.2. Tachograph Information .................................................................................................................................................. 13
7.3. Bench test ........................................................................................................................................................................ 14
7.4. Fixed distance 1 ............................................................................................................................................................... 15
7.5. Speed simulator ............................................................................................................................................................... 16
7.6. C3 RPM test ...................................................................................................................................................................... 16
7.7. DTCs ................................................................................................................................................................................. 17
7.8. k factor test ...................................................................................................................................................................... 17
7.9. DIL calculate ..................................................................................................................................................................... 18
7.10. Fixed distance 2 ............................................................................................................................................................... 19
7.11. Rolling road ...................................................................................................................................................................... 20
7.12. Clock test .......................................................................................................................................................................... 22
7.13. PIN .................................................................................................................................................................................... 22
7.14. Serial data test ................................................................................................................................................................. 23
7.15. CANbus data test ............................................................................................................................................................. 23
7.16. 1000m test ....................................................................................................................................................................... 24
7.17. Sensor settings ................................................................................................................................................................. 25
7.18. Tachograph reset ............................................................................................................................................................. 27
8. Custom Bench Test ...................................................................................................................................................................... 28
9. SE5000CS – Configuration System .............................................................................................................................................. 32
9.1.SE5000CS – Stoneridge Configurations ................................................................................................................................. 33
9.2.SE5000CS – User Configurations ........................................................................................................................................... 35
10. 1381CS – Configuration System .................................................................................................................................................. 37
11. Tacho Swap ................................................................................................................................................................................. 39
12. Sensor Test .................................................................................................................................................................................. 41
13. Rolling Road Brake ...................................................................................................................................................................... 42
14. Product Upgrade ......................................................................................................................................................................... 43
15. Wireless Photocell Test ............................................................................................................................................................... 44
16. DSRC Test .................................................................................................................................................................................... 44
17. GNSS Test .................................................................................................................................................................................... 45
18. Camera ........................................................................................................................................................................................ 45
19. Snipping Tool ............................................................................................................................................................................... 45
20. Calculator .................................................................................................................................................................................... 45
Annex A – Cable cross reference tables........................................................................................................................................... 46
Annex B – Programmable Parameters ............................................................................................................................................ 48
Annex C – Optimo² Error Codes ....................................................................................................................................................... 53

2
1. Optimo² Kit

Optimo² Screen Protector Digital Dongle PSU/Charger


Cullpower ICP12-050-2000B
Input:100 – 240V~ 50/60Hz, 0.3A
Output: 5Vdc, 2000mA

2. Optimo² Switching On
Power on/off

DIN Sockets USB Sockets Power Supply

Notes: Optimo has an in use temperature range of 10°C to 50°C

When charging Optimo, an ambient temperature of +40°C must not be exceeded

3
3. Optimo² Main Screen
▪ Optimo² supports all digital and analogue tachographs.

4. Optimo² Features

Component Optimo²
External USB ports 3
Bluetooth Yes
Wi-Fi Yes
Camera Yes, Front & Rear
Smart card reader Yes
Dongles Digital
I/O connectors DIN connectors
Battery charge time 4 hours
Vehicle charger Yes, USB
Screen dimming Yes
Screen rotation Yes
Screen protector Yes

4
5. Optimo² Sleep Mode & Switching Off
5 minutes inactivity Screen blank – programs still running Press ON button at rear to wake up
30 minutes inactivity Optimo² shuts down Press ON button at rear to re-start

▪ To Turn Optimo² Off.


▪ Tap Windows Icon in bottom left hand corner of the screen.

▪ Tap Power Icon, then Tap Shut down.

5
6. Getting Started
▪ How to set up your Optimo².

6.1. Task Bar Icons

6.1.1. Workshop Settings


▪ On first power up of Optimo² several details must be entered into the Workshop Settings screens.

▪ Workshop Settings screens can also be accessed at any time by tapping here.

▪ After selecting your Language and Country, enter your workshop details.
▪ Please complete all fields.

▪ Other screens are accessed by tapping the Arrows at the top of the page if highlighted.

Home Button Question Mark

Arrows

▪ The ‘Home’ button, single tap, returns to that application’s main screen. A double tap closes the
application and returns to the Windows desktop.

6
▪ This screen displays various details about your workshop and enables selection and settings for
Rolling Roads and Roller Brake Testers.
▪ Please complete all fields.

▪ The next screen sets Fixed distance length and number of runs, plus options for “Standard” or
“Custom” bench tests. For Custom Bench test see Chapter 8.
▪ For Pan ID and Channel ID, please refer to your dongle label.
▪ Please note that you cannot run two Optimo² with the same ID’s in the workshop.
▪ For multiple installation of Optimo² please contact Workshop Support

DETAILS ON ALL THESE SCREENS MUST BE COMPLETED BEFORE FIRST USE OF OPTIMO²

7
6.1.2. Connecting to Wi-Fi
▪ Tap the Wi-Fi icon.

▪ Select the network and tap “Connect” button.

▪ Follow the instructions as requested.

6.1.3. Wireless Connections


▪ There are two wireless indicators in the taskbar, one for connection to the tachograph and one
for connection to a Rolling Road. Both are red when disconnected and turn green when
connected.
Tachograph & Rolling Road disconnected Tachograph connected Rolling Road disconnected

8
6.2. Connecting to the Tachograph
▪ 3 dongles are supplied for Digital, 2400 and 1324 tachographs. These are inserted into the
programming socket as shown. Please wait 5 seconds after insertion before initiating any
Optimo² applications as this allows time for the tachograph and Optimo² to connect.

▪ All tachographs can also be connected using existing MKII cables.


▪ Note: 1324 Dongle only on 24V tachographs

6.3. Calibrating and Programming

▪ On tapping the icon, Optimo² identifies the connected tachograph. If the tachograph cannot be
determined the screen below is displayed. Select correct tachograph type.

9
7. Optimo² – MKIII Programmer – Main screens
▪ When a tachograph is detected or selected, the screen below is displayed.

▪ On these screens highlighted icons can be selected, those dimmed out cannot.

▪ The following sub-chapters briefly explain the function for each icon selection.

Read and modify data Chapter 7.1


Tachograph information Chapter 7.2
Bench test Chapter 7.3
Fixed distance 1 Chapter 7.4
Speed simulator Chapter 7.5
C3 RPM test Chapter 7.6
DTCs Chapter 7.7
K factor test Chapter 7.8
DIL calculate Chapter 7.9
Fixed distance 2 Chapter 7.10
Rolling road Chapter 7.11
Clock test Chapter 7.12
PIN Chapter 7.13
Serial data test Chapter 7.14
CANbus data test Chapter 7.15
1000m test Chapter 7.16
Sensor settings Chapter 7.17
Tachograph reset Chapter 7.18

10
7.1. Read and modify data

▪ Select the icon on the tachograph programming screen and this will open the Tiles Menu below
▪ Select the Tile you need for specific parameters.

▪ Note: A 2 yearly inspection only requires the Calibration Parameters tile

▪ Use the scroll bar to view all parameters in the tile



▪ Using the left or right arrows moves forwards or backwards through the tiles

▪ Press home to return to the Tiles menu

11
▪ Parameters are changed by tapping the value in the “Setting” column and then a new screen is
displayed along with the necessary keyboard, or for some parameters by selecting an appropriate
option from the list available in the Parameters column.

Note 1: In all cases, once settings have been altered, tapping the enter key immediately sends
that information to the tachograph. More screens are accessed by using the highlighted arrows
at the top of the page.

Note 2: For some tachographs, such as the Actia, once a setting has altered it will change colour
to show the setting has been changed but it will not send to the tachograph until you tap the
Home button at the top of the page, whereupon it sends all the data.

▪ To change a value, touch the setting on the screen. Use Backspace to remove characters, enter
new value, then tap the Enter key to update the tachograph.

▪ Tap the Home button to return to main programming screen.

Escape Backspace
Tab Keyboard Toggle
Caps Space
Shift Enter

12
7.2. Tachograph Information
▪ Tap the icon.

▪ Available on all Digital, 2400 or 1324 tachographs.

13
7.3. Bench test
▪ Tap the icon.

▪ For radio sized tachographs these tests are carried out semi automatically, with a countdown
timer displaying time remaining for each phase of the test.

▪ For round tachographs a speed scale must be selected first.

▪ For all bench tests follow on screen prompts, and select buttons, duties etc. as required.

Digital Bench test

Analogue Bench test

14
7.4. Fixed distance 1

▪ Tapping the icon enables the “w” factor to be determined using a physical method with a fixed
pointer over a fixed distance.

▪ The “w” value for each run is displayed. Carry out the appropriate runs as prompted.

▪ Test complete

▪ For round tachographs, DIL switch settings will be shown which must be manually set.

15
7.5. Speed simulator

▪ Tap the icon and then tap “Speed” box and enter the desired speed, then tap the tick button.

Increment
Speed

Decrement
Stop
Speed
Test

7.6. C3 RPM test


▪ Connect cable E to Optimo². Tap the icon.

16
7.7. DTCs

▪ Tap the icon and the tachograph DTCs are shown.

7.8. k factor test

▪ Tap the icon and using cable G on an 8400, 1318 or 1314, it will provide a reading of the k factor

17
7.9. DIL calculate

▪ Tap the icon and enter w factor. DIL switch settings, w factor and k exact are displayed on left.
This function does not require connection to a tachograph.

18
7.10. Fixed distance 2

▪ Tapping the icon enables the “w” factor to be determined using a physical method with an
external device such as a flexi switch, light barrier or wireless photocell over a fixed distance.
Connect the external device to Optimo².

▪ The “w” value for each run is displayed. Carry out appropriate runs as prompted.

▪ Test complete

▪ For round tachographs DIL switch settings shown must be manually set.

19
7.11. Rolling road

▪ Tapping the icon enables selection of Rolling Road test or Speed Verification test.

▪ With vehicle in motion, tap “Speed Verification”, check speed of Rolling Road and compare with
tachograph speed i.e. speed for speed check.

20
▪ For a Stoneridge rolling road, when you tap “Rolling Road” Optimo² determines the w and l
factors. When the test is complete, results can be sent directly to radio sized tachographs,
followed by a confirmation screen.

▪ For round tachographs w, k and l factors are displayed, plus the DIL switch settings which must
be manually changed.

21
7.12. Clock test

▪ Optimo² is always factory set to UTC time. It is essential that you ensure that Optimo² is always
correctly set to UTC time to ensure correct operation as a calibration instrument.

▪ Tap to check accuracy of clock and adjust UTC and local time if necessary. For round tachographs
a clock tester module is required and only tests the accuracy of the clock.

▪ On Digital tachographs all time adjustments should be done from this menu.

7.13. PIN

▪ Tap enter workshop card PIN. Available on SE5000 and DTCO 1381 only.

22
7.14. Serial data test

▪ Tapping the icon displays serial data from the tachograph via cables F & H for an SE5000, or
cables X & H for a 2400.

7.15. CANbus data test

▪ Tapping the icon displays CANbus data via cable V or DSRC Module Date via cable 801422

23
7.16. 1000m test

▪ Tap the icon and the k factor is displayed, tap the green tick button, the test starts, and a
countdown timer appears in a red circle.

▪ Test complete.

24
7.17. Sensor settings

▪ Tapping the icon enables selection of a sensor type on some tachographs.

▪ The following screen is for a VR2400.

▪ To pair an Encrypted sensor, tap “Pair”.

▪ Test complete.

25
▪ For 3rd generation digital tachographs activated after 1st October 2012, the following screen is
displayed. 2nd source of motion is enabled by selecting the appropriate CANbus or the C3 option.
For CANbus “Heavy” or “Light” vehicle also must be selected as data is transferred at different bit
rates.

▪ If C3 is enabled, a speed factor, derived from the l factor value must be entered to match the two
speed signals as close as possible, see table 1 below.

▪ To force pair a digital sender, tap “Pair”.

Table 1

26
▪ It is essential that the speed on the second source is closely matched to the speed from the
gearbox sensor. To verify this, and correct where necessary, press the up arrow on the
tachograph once to view the dual speed source screen as shown below.

▪ Run the vehicle at 50km/h and adjust the C3 speed factor until speed 2 is as close to speed 1 as
possible. The difference between speed 1 and speed 2 must not exceed 10km/h.

7.18. Tachograph reset

▪ Tapping sends a reset pulse by simulating an Off/On condition which resets the tachograph. No
screen is displayed on Optimo² when this happens, however there is an interruption to the
tachograph display.

27
8. Custom Bench Test

▪ For analogue tachographs, a Custom bench test allows a technician to set unique duty and speed
parameters in countries which allow this. To set a Custom bench test go to page 3 of “Workshop
Settings” then tap on the stars in the box adjacent to “Configure analogue bench test” in the 3rd
“Workshop Settings” screen.

▪ Enter the PIN, which is obtained from your SRE representative or distributor.

28
▪ Tap “Custom” to enter up to 15 Speed Test steps.

▪ Tap an empty box then enter the speed and duration of the step.

29
▪ To delete a step, tap the cross in the red box, then tap bin icon and step is deleted.

▪ Once all the Speeds have been entered, tap the red arrow top right to enter up to 5 duty steps.
Tap an empty box adjacent to a “Duty Test” step.

30
▪ Tap the Duty required, then key in duration for the test.

▪ Once final Duty test is entered, tap the red arrow top right, or Home Button, to exit the setup
procedure.

▪ Now when running an Analogue Bench test the tachograph type will be prefixed with “Custom
Bench Test”. On radio sized analogue tachographs “Auto Duty” is selected On or Off by tapping
the appropriate button, then follow on-screen prompts as normal.

31
9. SE5000CS – Configuration System

▪ Tap the icon and the message “Determining the Tacho Type” is displayed whilst Optimo² confirms
an SE5000 tachograph is connected. This enables configuration of KRM tachographs to parameters
of different vehicle types.

▪ A valid workshop card must be inserted, and PIN authenticated to reconfigure all activated
tachographs.

▪ You are now presented with two choices as shown below. By selecting ‘Stoneridge Configurations’
you will access the Stoneridge library of configuration files which is continuously updated.

▪ By selecting ‘User Configuration’, you will be able to save, in Optimo, a vehicle configuration you
have created and this can be recalled for use again and shared with other Optimo users

32
9.1. SE5000CS – Stoneridge Configurations

▪ Choose manufacturer by tapping appropriate the icon or tap “Verify Tachograph” to input a serial
number.

▪ If verification successful, the make and model of a configured tachograph is displayed.

33
▪ To configure to another vehicle type, tap appropriate Manufacturer’s icon and a list of associated
vehicle types is displayed.

▪ Tap icon for correct vehicle type, and a screen shows Optimo² communicating with the tachograph.
After a short time, the result is displayed.

34
9.2. SE5000CS – User Configurations
▪ On selecting User Configurations, the screen below is shown. Existing stored configurations are
shown alongside the options for Creating a new configuration or importing a configuration from a
memory stick connected to Optimo
▪ Note: To create a new configuration, the tachograph must be activated

▪ Select ‘Create New’ and the current configuration of the tachograph connected will be read
▪ Once read, you can name the configuration. All fields must be completed
▪ Press next to store the new configuration and it will be available in the User configuration list
▪ Where possible, all parameters of the SE5000 used to create the new user configuration will be
stored

35
▪ When you select a user generated configuration file, several choices are available as shown below

▪ Import – this allows the Optimo user save shared configurations from another Optimo user to their
Optimo for future use.

▪ Export – this allows the Optimo user to save a copy of a configuration file they have created to a
USB stick so that this can be shared with other Optimo users.

▪ Delete – this allows the Optimo user to remove a stored user configuration file from their Optimo

▪ Send To Tachograph – this allows the Optimo user to write the selected configuration file to the
Se5000. When the parameters are written to the tachograph. If a parameter cannot be written to
the specific version of SE5000 you are connected to then Optimo will ignore this and continue. The
number of successfully written parameters is shown when the process is completed. The SE5000
does not need to be activated

36
10. 1381CS – Configuration System
▪ Tap the icon and a message “Please check the 1381 Tachograph Universal model is connected using
a wired connection before beginning the Configuration.” is displayed. Do not use this feature when
in wireless operation.

▪ Then a new message “Determining the Tacho Type” is displayed whilst Optimo² confirms a 1381
tachograph is connected. This enables configuration of 1381 tachographs to parameters of different
vehicle types.

▪ A valid workshop card must be inserted, and PIN authenticated to reconfigure all activated
tachographs.

▪ Choose manufacturer by tapping appropriate icon or tap “Verify Tachograph” to input a serial
number.

▪ If verification successful, the make and model of a configured tachograph is displayed.

37
▪ To configure to another vehicle type, tap appropriate Manufacturer’s icon and a list of associated
vehicle types is displayed. Select the 1381 Universal Model and then select your target vehicle type.

▪ Tap the icon for correct vehicle type, and a screen shows Optimo² communicating with the
tachograph. After a short time, the result is displayed.

▪ Note: Should the incorrect configuration of the 1381 be entered, the default VDO configuration
must be reloaded, prior to re-configuring the 1381 correctly.
▪ Note: From 2022, new VDO 4.0, or higher part numbers are not verified by this application. The
user must select the correct configuration from a larger number of choices and we recommend you
follow the VDO guidelines for choosing the correct Universal VDO tachograph and configuration.

38
11. Tacho Swap

▪ Tapping this icon displays which tachograph is connected and gives options to “Read” or “Send”
data. This function enables removal and fitment of a tachograph in a seamless process. For same
tacho type exchange, all parameters are transferred. For cross type exchange, only calibration
parameters are transferred.

▪ Note: the new tachograph must be configured prior to performing the tacho swap operation. For
digital tachographs this should be done before the unit is activated.

▪ Tap “Read” and Optimo² reads all data from the tachograph and gives an option to view stored
data.

39
▪ Tap the tachograph button to display stored information.
Note: You do not have to view data before sending it.

▪ Tapping “Send” displays which tachograph is connected, and options of which tachograph data to
send. Tap the appropriate button and a tick is displayed on completion.

40
12. Sensor Test

▪ Tapping this icon provides the facility to read information from the sensor using a cable connected
directly to the sensor from Optimo².

▪ Tapping “Sensor Information” supplies information about the connected Sensor.

41
13. Rolling Road Brake

▪ If your Rolling Road is connected wirelessly to Optimo² the Rolling Road Brake icon will appear.

▪ Tapping the icon enables a user to Apply or Release the Rolling Road brake via Optimo².

▪ Initially both buttons will be active as the system does not know what state the brakes are currently
set to.

▪ If you tap the Apply Brake button, it will apply the brakes to the rollers and that button will then be
inactive leaving only the Release Brake option, and vice versa.

42
14. Product Upgrade

▪ Product upgrades for Optimo² may be sent to you as a link to download or as a file for you to load
onto a USB stick.

▪ Connect the USB stick with the upgrade files to a USB socket on Optimo². When Optimo² recognises
the USB stick it may open a pop-up window; close this window.

▪ Given that there are different files depending on whether you have a Dell or Linx based Optimo² it
is essential you verify on the upgrade screen that you are replacing a .2xxx file with a .2xxx or a
.3xxx with a .3xxx file

▪ Tap the Product Upgrade icon and both current version and new version are displayed.
.
▪ Tap the “upgrade” button and follow the prompts.

▪ “Error” is displayed if Optimo² does not recognise the USB device, if no device present, or if the
wrong update is present. If this occurs, check the USB device is inserted correctly and the correct
upgrade present.

43
15. Wireless Photocell Test

▪ This application ensures that there is communication between the Wireless Photocell and Optimo².

▪ Tap the icon to open the program, the screen below is presented. Follow the instructions given.

▪ Pass the photocell over the tape once every 5 seconds, screen below should be achieved. If the
failure screen is received, check that the photocell is fully charge, the LED illuminates when the
product passes the tape and the Pan and Channel ID’s match. If so, switch off the photocell, leave
for 10 seconds, switch back on and repeat the test.

16. DSRC Test

▪ There is separate manual on Optimo² for the DSRC tester, please refer to this for full guidelines in
the use of this application.

44
17. GNSS Test

▪ There is a separate manual on Optimo² for the GNSS Test, please refer to this for guidelines in the
use of this application.

18. Camera

▪ The camera application permits the user to take pictures using the front or rear camera. Pictures
are stored in the Pictures folder in the Your Documents folder on the desktop.

19. Snipping Tool

▪ This application permits the user to take a snapshot of the Optimo2 screen. This can be particularly
helpful when trying to describe a fault seen in the workshop where the information needs to be
shared with Technical Support. Pictures are stored in the Pictures folder in the Your Documents
folder on the desktop.

20. Calculator

▪ This application permits the user to use the different calculators present in the Windows
application.

45
Annex A – Cable cross reference tables
This table shows a list of existing cables that can be used with Optimo²

Part Number Description Cable Identification Current Din Connector


7780-981 Tachograph Drive Lead CABLE C 6 way
7780-982 Vehicle Sender Conn. Lead CABLE D 6 way
7780-983 PPR/Engine Rev Calibration CABLE E 6 way
Lead
7780-986 Serial Data Out Adaptor Lead CABLE F Use with Cable H
7780-984 Jack Socket Connection Lead CABLE G 6 way
7780-989 Serial Data Conn Lead CABLE H 4 way
7780-987 Adaptor Cable (1400) CABLE K 6 way
7780-988 Adaptor Cable (1314) CABLE L 6 way
7780-974 Motometer Pulser Adaptor CABLE M Use with Cable C
7780-980 Motometer Programming Lead CABLE N 8 way
7780-979 1319 Jack Socket Adaptor Lead CABLE O Use with Cable G
7780-973 1319 Programming Lead CABLE P 8 way
7780-975 Motometer Revs Adaptor CABLE Q Use with Cable G
7780-978 Flat Wire Cable Adaptor 8400 CABLE S Use with Cable G
7780-977 Flat Wire Cable Adaptor 1314 CABLE T Use with Cable H
7780-936 2400 Programming Lead CABLE U 8 way
7780-956 2400 Canbus Data Lead CABLE V 8 way
7780-952 MTCO Programming Lead CABLE W 8 way
7780-955 2400 Serial Data Adaptor Lead CABLE X Use with Cable H
7780-810 Digital Programming Lead CABLE Z 8 way
7955-938 Clock Tester 8 way
7955-777 Flexi Switch 4 way
7780-948 Kienzle Laser Device Adaptor 4 way
7500-008 Rolling Road Cable 4 way

46
Available functions and required harnesses
Tachograph VR2400 VR8400 VR8300 VR1400 K1324 K1319 K1318 K1314 Moto- SE5000 DTCO Smar-
Meter tach
Function EGK100
Rolling U or D G+J or G+J or K W or G+O+J G+J or G+J or N Z or D Z or Z or D
Road D D L D
D D
Fixed Dist U or D G+J or G+J or K W or G+O+J G+J or G+J or N Z or D Z or Z or D
#1 D D L D
D D
Fixed Dist U or D G+J or G+J or K W or G+O+J G+J or G+J or N Z or D Z or Z or D
#2 D D L D
D D
Bench Test C G+S+J C K C or O G+O+J G+S+J G+T+J C+M or Z Z Z
or C or C or C or L N
Speed U or C G+S+J C K W or G+O+J G+S+J G+T+J C+M or Z Z Z
Simulator or C C or C or C or L N
RPM Pulse E E E - W - E - N - - -
Test
Clock Test U Clock Clock - W Clock Clock Clock N Z Z Z
Tester Tester Tester Tester Tester
Tacho U G+J - - W or - - - N - - -
Control C
Identify U - - - W - - - - Z Z Z
Tacho
Read/Erase U - - - W - - - - Z Z Z
DTCs
Send All U G+J - - W P - - N Z Z Z
Data
Modify U - - - W P - - N Z Z Z
Data
Read All U - - - W P - - N Z Z Z
Data
Program - G+J - - - - - - - - - -
Tacho
k factor - G+J - - - G+O+J G+J G+J - - - -
Test
Pair / Test - - - - - - - - - Z Z -
Time / - - - - - - - - - Z Z Z
Date
Enter PIN - - - - - - - - - Z - -

Notes:
(1) Fixed Distance #2 also requires the Flexi Switch, light barriers or Wireless Photocell
(2) DIL Calculate, Tacho Select and Pulser Select do not require any connections to the tachograph

47
Annex B – Programmable Parameters
Programmable Parameters Access VR DTCO Kienzle
Read/Write SE5000 2400 1381 1324 Actia Efkon
Text displayed Description
System Supplier Identifier R X X X X X
ECU Manufacturing Date R X X X X X
ECU Serial Number R X X X X X
System Supplier ECU Hardware
R X X X X X
Number
System Supplier ECU Hardware
R X X X X X
Version Number
System Supplier ECU Software
R X X X X X
Number
System Supplier ECU Software
R X X X X X
Version Number
System Name Or Engine Type R X X X X X
w-factor Vehicle Characteristic w factor R/W X X X X X X
k-factor k factor R/W X X X X X
Odometer Total Vehicle Distance R/W X X X X X X
Current time + Time/Date
Current date + R/W X X X X X
Time offset
l-factor Tyre Circumference l factor R/W X X X X X X
Tyre size Tyre Size R/W X X X X
Next Calibration Next Calibration Date
R/W X X X X
Date
Vehicle Registering Member State
Registration R/W X X X X
Nation
VRN Vehicle Registration Number R/W X X X X
Speed Authorised Speed Authorised R/W X X X X X
VIN Vehicle Identification Number R/W X X X X X X
DSRC Serial DSRC Serial Number
R/W X X
Number
Motion sensor Sensor Serial Number
R X
serial number
Tachograph Seal Entry for up to 5 seal records
R/W X X
Record
CANBus enabled Can Enable on A-CAN R/W X X
CAN Termination CAN Termination on A-CAN R/W X
CAN trip reset CAN Trip Reset Service
R/W X
Component Id
CANBus type Transmission Repetition Rate Of
R/W X X X X
TCO1 Message

Reset Heartbeat Reset Heartbeat Message


R/W X X X X

O/P shaft factor Pulses Per Revolution Of Output


R/W X X X X X X
Shaft
A-CAN type Set speed of A-CAN R/W X

48
Programmable Parameters Access VR DTCO Kienzle
SE5000 Actia Efkon
Read/Write 2400 1381 1324
Text displayed Description
A-CAN Set A-CAN diagnostic version
R/W X
diagnostics
C CAN Enable/Disable C CAN R/W X
C-CAN type Set speed of C CAN R/W X
C-CAN Set C-CAN diagnostic version
R/W X
diagnostics
C2-CAN Type Set speed of C2-CAN R/W X
A CAN TCO States R/W X
C CAN TCO States R/W X
A CAN TCO
R/W X
Events
C CAN TCO
R/W X
Events
DSRC CAN Select which CAN the DSRC is
R/W X X
Selection connected to
DSRC CAN Set CAN Address for the DSRC
R/W X X
Address module
DSRC Parameter
R/W X X
Group Number
Optional CAN
R/W X
Messages 3
Optional CAN
R/W X
Messages 4
Backlight Select Display Backlight Selection R/W X
Illumination Lvl Illumination Level R/W X
Illumination Off Illumination Offset R/W X
Illumination Illumination Input, (A2/CAN)
R/W X
Input
Speedo Output D6 Factor (speedometer OP
R/W X X
factor factor)
D6 pin function D6 Pin Functions, (Speed Pulse
R/W X X
Output)
D6 pin function Pin D6 R/W X
Filter pin B3 Filter - speed sensor signal pin R/W X
(B3)
D5 pin function D5 Pin Enabled, (Over Speed
R/W X
Output)
D4 pin function D4 Pin Functions, (General
R/W X X
Warning Output)
D7 pin function D7 Pin Enabled, (K-line Rear) R/W X
C1 pin function Settings off C1 output R/W X
Revs Input Revs Input, (C3/CAN)
R/W X X
C3/CAN
RPM Factor Rpm Factor, (C3 factor) R/W X X X
V-Impulse
R/W X
Control
Serial Data Out Serial Data Output, (D8 Functions) R/W X X
Low speed Limit Low Speed Limit R/W X X
Card Support Select what types of card are
R/W X
supported

49
Programmable Parameters Access VR DTCO Kienzle
SE5000 Actia Efkon
Read/Write 2400 1381 1324
Text displayed Description
Ignition Activity Activity change at Key on/off
R X
Change
Definition Key Activity at ignition ON/OFF
R/W X X
On/Off
Pref. Language Default Language R/W X
Service delay Service Delay Calendar Time
R/W X X X X
Based
Install date ECU Installation Date R/W X X X X
Pre-Next Days left until next calibration
R/W X
Calibration
Pre-Overspeed Pre overspeed R/W X
Display function Display function R/W X
DDS Format R/W X
Speed mean filter
Write once X
parameters
Ignition Off Level R/W X
Ignition On Level R/W X
No Ignition
R/W X
Warning Delay
Centralized
R/W X
Language
Sleep Mode R/W X
Latitude R X X
Longitude R X X
Vehicle GNSS-
R X
Based Speed
GNSS Antenna
R/W X X
Choice
GDOP Geometric dilution of precision R X
PDOP Position (3D) dilution of precision R X
TDOP Time dilution of precision R X
VDOP Vertical dilution of precision R X
HDOP Horizontal dilution of precision R X
GNSS fix type R X
Number of Number of satellites locked on for
R X
satellites GNSS fix
GNSS clock drift
RD Activity Status Remote download activation
R X
status
RD Card Writing Remote download card writing R/W X
RD A CAN Remote download A-CAN
R/W X
Configuration configuration
RD C CAN Remote download C-CAN
R/W X
Configuration Configuration
Show Remote Show remote download
R/W X
Download
CAN2 remote
R/W X
download

50
Programmable Parameters Access VR DTCO Kienzle
SE5000 Actia Efkon
Read/Write 2400 1381 1324
Text displayed Description
CAN wake up CAN wake up R/W X
2nd source of motion R X
2nd source of motion, allowed
R/W X
offset
2nd source of motion, speed diff. R/W X
2nd source of motion, CAN msg. R/W X
C3 speed factor R/W X
Show Driver Card
R/W X
Download
Request Card
R/W X
Download
Confirmed Driver
R/W X
Activity
Enable driver
card download R/W X
question
Enable driver
card download R/W X
menu
Add. Event Rec. Use Of D1 D2 Registration R/W X
Eng. Speed Rec. Use Of Engine Speed Registration R/W X X
VRESD Vu Ranges Engine Speed Data R/W X
Vehicle Speed Use Of Vehicle Speed Registration
R/W X
Rec.
VRVSD Vu Ranges Vehicle Speed Data R/W X
Maximum Maximum Warranty Time
R X
Warranty
Warranty Valid Warranty Validity Time
R X
Time
Warranty Time Warranty Time R/W X
Number of writes Number of writings to Warranty
R X
Warranty Time
Activation Time Time of activation R X
Driver 1 Consent
R X
Status
Driver 2 Consent
R X
Status
Warning expiry
R/W X
date – calibration
Warning expiry
R/W X
date – driver card
Warning expiry
date – workshop R/W X
card
Warning expiry
date – company R/W X
card
Warning expiry
date – control R/W X
card

51
Programmable Parameters Access VR DTCO Kienzle
SE5000 Actia Efkon
Read/Write 2400 1381 1324
Text displayed Description
Driver card
download R/W X
reminder
Dimming Input Dim mode R/W X
CAN Dimming Can Dim mode
R/W X
Input
Diming Dim parameters
R/W X
Parameters.
Dim preset Dim-mode preset
R/W X
record
Kline Speedo R/W X
Pulses per engine revolution R/W X
CANbus RPM R/W X
RPM Display R/W X
Odometer leading 0s R/W X
Overspeed flash R/W X
Overspeed R/W X
Customer Type R/W X
Dual Axle R/W X
Dual Axle ratio R/W X
Crew auto duty R/W X
7 day eject PIN R/W X
Ignition-on recording R/W X
DTCs enabled R/W X
4th chart trace R/W X
Analogue Revs R/W X
Rev Band Limits - Low Power
R/W X
Band
Rev Band Limits - Economy Band R/W X
Rev Band Limits - Poor Economy R/W X
CANBus type CANbus Type. This is part of ECU
R/W X
Hardware Number
Repair Shop Code Or Tester Serial
W X X X
Number
Programming Date W X X X
Calibration Equipment Serial
Number OR W X X X
Calibration Repair Shop Code
Calibration Date W X X X
Calibration Equipment Software
W X X X
Number

52
Annex C – Optimo² Error Codes
Application Codes

APPLICATION Error Code

MK3 Programmer 0x00** Codes 01 to 10 / 20 to 29 / D0 to FF are valid

SE5000 Configuration System 0x01** Codes 01 to 10 / 40 to 41 / D0 to FF are valid

Tachograph Swap 0x02** Codes 01 to 10 / D0 to FF are valid

Sensor Test 0x03** Codes 01 to 10 are valid

Application Sheets 0x04** Codes D0 to FF are valid

Cross Reference 0x05** Codes D0 to FF are valid

Workshop Settings 0x06** Codes D0 to FF are valid

Calibration 0x07** Codes D0 to FF are valid

Product Upgrade 0x08** Codes C1 and C2 are valid

Taximeter 0x09**

DTCO1381 Configuration 0x0A**


System

Wireless Brake 0x0B**

DSRC Test 0x0C** Codes 01 to 10 / 20 to 29 / BA / BC / D0 to FF are valid

GNSS Test 0x0E** Codes 01 to 10 / 20 to 29 / 90 to 93 / D0 to FF are valid

Wireless Photocell Test 0x0F**

53
Specific Error Codes

Error Category Error Category


Code Code

0x**01 Comms Timeout 0x**20 Tacho Value Out Of Range

0x**02 Transfer Aborted Returned 0x**21 Upload Not Accepted

0x**03 General Reject 0x**22 Requested Data Unavailable

0x**04 Security Access Denied 0x**24 Tacho Not In Correct Mode

0x**05 Request Out Of Range Returned 0x**25 Data Parameter Not Accepted

0x**06 Service Error 0x**26 Pin Timeout Has Occurred

0x**07 Tacho Type Incorrect 0x**27 No Card Detected In Tacho

0x**08 Can Or Serial Data Timeout 0x**28 Incorrect Card Type In Tacho

0x**09 IF Board Comms Error 0x**29 Invalid Pin Entered Into Tacho

0x**0A PC Comms Port Error 0x**30 Comms Timeout Interface Board

0x**0B Function Not Supported 0x**40 No Config Found

0x**0C Renesas Frequency Calibration Error 0x**41 Tacho Not Configured

0x**0D Invalid Key 0x**90 No Internet Connection

0x**0E Number Attempts Exceeded 0x**91 Internet Mapping Service Error

0x**0F Required Time Delay Not Expired 0x**92 No GNSS Tacho Data

0x**10 Sub Not Supported Invalid Format 0x**93 No Optimo Location Data

0x**11 Sub Not Supported Inactive Session 0x**A0 Seal Number Incorrect Length

0x**12 Svc Not Supported Inactive Session 0x**BA Workshop Card Not Detected

0x**13 Svc Not Supported Inactive Diag Mode 0x**BC Workshop Card Not 1C

0x**14 Transfer Data Suspended 0x**C1 Product Upgrade Error

0x**15 General Programming Failure 0x**C2 Product Upgrade Platform Invalid

Incorrect Msg Len Or Invalid Format 0x**D0 Cannot Connect To Or Retrieve Data From
0x**16
App Database

Bad Checksum Illegal Byte Count Block 0x**D1 Data Not Found In App Database
0x**17
Transfer

0x**18 Target Address Not This Device 0x**DF General Data Error

Data Received From Unknown Source 0x**E0 C8051 Init Error


0x**19
Address

54
Error Category Error Category
Code Code

0x**E1 C8051 Wrong Device ID

0x**E2 C8051 Not Blank

0x**E3 C8051 Flash Update Failed

0x**E4 IF Board Firmware Upgrade Error

0x**EF IF Board Firmware Error

0x**F0 Unit Not Calibrated Error

0x**F1 Logging Error

0x**F2 Calibration Result Error

0x**F3 Touch Screen Software Not Found

0x**FE EULA Not Signed

0x**FF General Error

55