6/4/2021 Anodic Protection

Sulphuric Acid on the WebTM Technical


Manual DKL Engineering, Inc.

Knowledge for the Strong Acid System - Acid Cooling - Shell and Tube - Anodic
Sulphuric Acid Protection
Industry September 21, 2001

Anodic Protection Associated Links


Reference Electrode
Sulphuric Acid on the
Controller  
Web Power Unit
Cathodes
Introduction
General
Equipment Suppliers
Contractor
Anodic Protection
Instrumentation
Industry News Anodic protection depends on the formation of a
Maintenance passive film on a metal immersed in an
Acid
Traders electrolyte by the application of an anodic
Organizations
potential to the metal.  The passive state is
Fabricators
Conferences
defined as a state of increased corrosion
Used
Plants resistance of metals and alloys caused by control
Intellectual
Propoerty of the anodic process through anodic
Acid
Plant Database polarisation.
Market
Information
Library
The tubes and shell of the exchanger that are in
 
contact with the sulphuric acid are maintained at
Technical Manual the required potential in the passive region by  
measuring this potential versus a reference
Introduction electrde and transmitting the value to the
General
potential controller.  The controller has a set
Definitions
Instrumentation
value corresponding to a chosen potential in the
Plant Safety passive range.  Any difference between the set
Metallurgial
Processes value and the measured potential causes the
Metallurgical controller to signal the direct current power
Sulphur Burning source to supply enough current to bring the
Acid Regeneration vessel to the required passive potential.
Lead Chamber
Technology
Gas Cleaning An individual power source is provided for each control unit and this is sized to
Contact meet the requirement for the initial passivation procedure.   This may take
Strong Acid approximately 4 hours on the drying tower acid system and 1 to 2 hours on the
Acid Storage absorber acid system.  After reaching the passive state, the current
Loading/Unloading requirements are very low, 1 to 2 amps on the absorber acid system and
Transportation
somewhat higher on the dry acid system.
Sulphur
Systems
Liquid SO2
Boiler Feed Water The anodic protection system consists of the following components:
Steam Systems
Cooling Water  
Effluent Treatment
Utilities
Construction Reference Electrode
Maintenance
Inspection The reference electrodes are submerged in the acid.  These electrodes are the
Analytical Procedures sensing devices for obtaining the metal potential of the acid wetted metal
Materials of Construction
surfaces.  Usually it is the electrode at the acid inlet that is used for control
Corrosion
Properties
purposes.
Vendor Data
 
DKL Engineering, Inc.
Controller
Handbook of Sulphuric Acid
Manufacturing
The controller displays and monitors the potentials of the reference electrodes. 
Order
Form
Preface
The potential from the reference electrode is compared to the set point and a
Contents signal is transmitted to the power unit adjusting its output in order to maintain
Feedback the reference electrode at the control point.

www.sulphuric-acid.com/techmanual/Strong Acid/sa_acidcooling_anodic.htm 1/2


6/4/2021 Anodic Protection
Sulphuric Acid Decolourization  
Order Form
Preface
Table of Contents Power Unit

Process Engineering Data The power unit supplies the


Sheets - PEDS necessary current to the
Order Form cathodes for passivation.  The
Table of Contents
output is controlled by the
Introduction
Controller.
Bibliography of Sulphuric Acid
Technology  
Order Form
Preface Cathodes
Contents

The main and pin cathodes are


Sulphuric Acid Plant
Specifications
submerged in the acid to
  provide the electrical contact
for current to be supplied
Google Search

through the acid to the acid
wetted surfaces of the cooler.

 
Copyright© 2005-2018 DKL Engineering, Inc., All Rights Reserved
DKL Engineering, Inc. shall not be held liable for any type of
damages resulting from the use of this information. The user assumes all risk and
liability in connection with the use of information contained in this and associated web
sites. The data is intended for personal, non-commercial use.

www.sulphuric-acid.com/techmanual/Strong Acid/sa_acidcooling_anodic.htm 2/2

You might also like