RANCANGAN TEBATAN BANJIR SUNGAI BUNUS, WILAYAH PERSEKUTUAN KUALA LUMPUR

MENYIAPKAN BAKI KERJA PROJEK MEMBINA DAN MENYIAPKAN KOLAM TAKUNGAN BANJIR
SERTA KERJA-KERJA BERKAITAN DI PULAPOL, KUALA LUMPUR
TENDER NO : JPS/IP/PB/01/2021
PART 3: MECHANICAL & ELECTRICAL
BILL NO.3A: ELECTRICAL (REMAINNING WORKS)
All Quantities Are Provisional
Amount TENDER(RM)
ItemCode No Description Unit Qty
Rate Amount

ELECTRICAL WORKS

All electrical components (makes and model) supplied to be

from JKR JMAL/EMAL approved list only.

A MAIN SWITCH BOARD

To supply, install, testing and commissioning the following as


per

drawings and specifications, and other related works although

not listed/described but deemed necessary and essential for

proper and safe operation of equipment/installation c/w cable

termination at both end and other accessories.

1 U680 To supply, delivery to the site, complete installation, testing sum 1


and

commissioning of Main Switch Board (MSB-PULAPOL) complete

with ACB, MCCB's,RCCB's, MCB's, SPD,VSDs with harmonic

filter, A/T Starters, Motor Protection Relay, Marshalling


panel,
capacitor bank (525V) with 7% reactor and power factor
regulator,
wiring, cable terminations and other related work as per
LS-1 JKR SPECIFICATION.

2 U636 sum 1
To supply and install Complete earthing for MSB to meet TNB

and IEC 60364 requirements c/w earth electrode, copper


tape,
earth chamber etc as per drawings and specifications for
complete installation. The effective impedance shall be 1 ohm
or
less as per IEC 60364, Suruhanjaya Tenaga and TNB
requirements.

TOTAL CARRIED TO BILL SUMMARY -

PART 3 - Bill 3A - 1/6


RANCANGAN TEBATAN BANJIR SUNGAI BUNUS, WILAYAH PERSEKUTUAN KUALA LUMPUR
MENYIAPKAN BAKI KERJA PROJEK MEMBINA DAN MENYIAPKAN KOLAM TAKUNGAN BANJIR
SERTA KERJA-KERJA BERKAITAN DI PULAPOL, KUALA LUMPUR
TENDER NO : JPS/IP/PB/01/2021
PART 3: MECHANICAL & ELECTRICAL
BILL NO.3A: ELECTRICAL (REMAINNING WORKS)
All Quantities Are Provisional
Amount TENDER(RM)
ItemCode No Description Unit Qty
Rate Amount

B SUBMAIN CABLING

To supply and install cabling using the following cu. Cable. The

work shall include all necessary accessories and other related

work to complete the work. All quantities given are


PROVISIONAL. The actual quantities installed shall be
measured

on site after completion and prices adjusted accordingly as per

LS-1 and LS-3 SPECIFICATION.

1 U631 Mtr 100


1 X 50mmsq /4C XLPE/SWA/PVC Cu. From MSB-PULAPOL to

LOCAL CONTROL PANEL NO.3 and JOCKEY PUMP

2 U631 Mtr 50
2 X 10mmsq /1C PVC + 1 X 10mmsq C.P.C From MSB-PULAPOL

to DB-CONTROL HOUSE

3 U631 Mtr 50
2 X 10mmsq /1C PVC + 1 X 10mmsq C.P.C From MSB-PULAPOL

to DB-UNDER WATER LIGHTING

C DISTRIBUTION BOARD

1 U680 To supply and install DB Control House (Metal Clad) c/w sum 1
MCB's, RCCB's and other necessary accessories as per
drawing and JKR LS-1 SPECIFICATION.

2 U680 To supply and install DB-MSB (Metal Clad) c/w MCB's, sum 1
RCCB's and other necessary accessories as per drawing and
JKR
LS-1 SPECIFICATION.

3 U680 sum 1
To supply and install DB-UNDER WATER LIGHTING (Metal

Clad) c/w MCB's, RCCB's and other necessary

accessories as per drawing and JKR LS-1 SPECIFICATION.

TOTAL CARRIED TO BILL SUMMARY -

PART 3 - Bill 3A - 2/6


RANCANGAN TEBATAN BANJIR SUNGAI BUNUS, WILAYAH PERSEKUTUAN KUALA LUMPUR
MENYIAPKAN BAKI KERJA PROJEK MEMBINA DAN MENYIAPKAN KOLAM TAKUNGAN BANJIR
SERTA KERJA-KERJA BERKAITAN DI PULAPOL, KUALA LUMPUR
TENDER NO : JPS/IP/PB/01/2021
PART 3: MECHANICAL & ELECTRICAL
BILL NO.3A: ELECTRICAL (REMAINNING WORKS)
All Quantities Are Provisional
Amount TENDER(RM)
ItemCode No Description Unit Qty
Rate Amount

D FINAL SUB-CIRCUIT WIRING

To supply, install, testing and commissioning the following


final-sub circuit wiring as per drawings and JKR LS-1
SPECIFICATION.

1 U634 To wire up all 13A switch socket outlet concealed in G.I nos 15
conduit

c/w 13A switch socket outlet and other necessary accessories.

nos 4
To wire up aircond point concealed in G.I conduit c/w single
2 U634

phase 20A isolator switch, timer, neon indicating lights, looping

point wiring and 15A switch socket outlet.

nos 23
To wire up all lighting points in concealed G.I conduit c/w 10A
3 U634
switch, terminations and other necessary accessories.

nos 6
To wire up Emergency Lighting points using 2 x 1.5 sq.mm/1C
4 U634

PVC Cu. Cable + 1 x 1.5 sq.mm/1C PVC Cu. C.P.C in concealed G.I

conduit c/w terminations and other necessary accessories.

nos 3
To wire up all exhaust fans points in concealed G.I conduit c/w
5 U634
terminations and other necessary accessories.

E ELECTRICAL FITTING

The following must be supplied and install c/w approved resin

low loss ballast (6W) starter, power factor correction


capacitor,

tube approved by JKR EMAL and other necessary accessories.

1 U661 nos 16
1 X 36W surface mounted fluorescent fitting bare channel c/w

tubes.

2 U661 1 X 36W weatherproof fluorescent fitting c/w tubes. nos 7

TOTAL CARRIED TO BILL SUMMARY -

PART 3 - Bill 3A - 3/6


RANCANGAN TEBATAN BANJIR SUNGAI BUNUS, WILAYAH PERSEKUTUAN KUALA LUMPUR
MENYIAPKAN BAKI KERJA PROJEK MEMBINA DAN MENYIAPKAN KOLAM TAKUNGAN BANJIR
SERTA KERJA-KERJA BERKAITAN DI PULAPOL, KUALA LUMPUR
TENDER NO : JPS/IP/PB/01/2021
PART 3: MECHANICAL & ELECTRICAL
BILL NO.3A: ELECTRICAL (REMAINNING WORKS)
All Quantities Are Provisional
Amount TENDER(RM)
ItemCode No Description Unit Qty
Rate Amount

3 U661 nos 6
8 Watt surfaced type self contained Emergency light (Bomba

approved type) c/w rechargeable battery with operation of


min.

3 hrs and other necessary accessories as per specifications.

4 U661 To supply and install industrial exhaust fans c/w other nos 3
necessary accessories.

F UNDER WATER LIGHTING

1.00 U661 To supply, delivery to the site, complete installation, testing nos 16
and
commissioning 60W LED water proof (IP68) underwater
lighting c/w

termination box and all necessary accessories to be functional.

G MINI STADIUM LIGHTING

1 U662 To supply and install 12 meter height HOT DIPPED nos 6


GALVANISED
pole c/w internal wiring using 2.5 sq.mm PVC/PVC cable,
loop-in loop-out junction box, cut-out fuses, its associated
bolts
and nuts, and all necessary accessories.

2 U662
To allow road cutting, excavate and making good of existing Lot 1

premix road.

H SOLAR COMPOUND LIGHTING

1 U662 To supply, delivery to the site, complete installation, testing


nos 10
and

commissioning 70W LED solar compound lighting on 6m pole,

c/w control gear, PV panel, battery for operation of min. 12


hours,
control panel, mounting base and its bolts and nuts.

I LIGHTNING PROTECTION & EARTHING SYSTEM

1 U636 Complete lightning protection system (Faraday Cage System)


sum 1
for

the whole Building complete with air terminals, copper down

conductors, earth inspection chambers, copper rods, test


clamps,
exothermic welds, lightning flash counter, accessories etc as
per
specifications. The effective impedance of the earthing shall
be
below 10 ohms accordingly as per LS-09 JKR
SPECIFICATION.

TOTAL CARRIED TO BILL SUMMARY -

PART 3 - Bill 3A - 4/6


RANCANGAN TEBATAN BANJIR SUNGAI BUNUS, WILAYAH PERSEKUTUAN KUALA LUMPUR
MENYIAPKAN BAKI KERJA PROJEK MEMBINA DAN MENYIAPKAN KOLAM TAKUNGAN BANJIR
SERTA KERJA-KERJA BERKAITAN DI PULAPOL, KUALA LUMPUR
TENDER NO : JPS/IP/PB/01/2021
PART 3: MECHANICAL & ELECTRICAL
BILL NO.3A: ELECTRICAL (REMAINNING WORKS)
All Quantities Are Provisional
Amount TENDER(RM)
Item Code Description Unit Qty
Rate Amount

J TESTING & COMMISSIONING

1 A325
Testing and Commissioning the electrical installation to the sum 1

requirements of Tenaga Nasional Berhad and other relevant

authorities and to the satisfaction of the S.O., including but


not
limited to MSB, LCP and overall system operation, i.e.
Crest Gate, Mechanical Trash Rake, Flushing Gates,

Screw Down Gates, Pumping equipment and Grit Classifier.

K OTHERS

1
Item not included in the above, but shown on the drawings,

described in the specification, required by legislation or

necessary for the successful completion and satisfactory

operation of the entire installation. If none is required please


write
NIL' otherwise full details of the items are to be given.

a) sum -

b) sum -

c) sum -

TOTAL CARRIED TO BILL SUMMARY -

PART 3 - Bill 3A - 5/6


RANCANGAN TEBATAN BANJIR SUNGAI BUNUS, WILAYAH PERSEKUTUAN KUALA LUMPUR
MENYIAPKAN BAKI KERJA PROJEK MEMBINA DAN MENYIAPKAN KOLAM TAKUNGAN BANJIR
SERTA KERJA-KERJA BERKAITAN DI PULAPOL, KUALA LUMPUR
TENDER NO : JPS/IP/PB/01/2021
PART 3: MECHANICAL & ELECTRICAL
BILL NO.3A: ELECTRICAL (REMAINNING WORKS)
All Quantities Are Provisional
Amount TENDER
Item Description
(RM)

SUMMARY OF :
PART 3: MECHANICAL & ELECTRICAL
BILL NO.3A: ELECTRICAL (REMAINNING WORKS)

Collection

1 PART 3- Bill No.3A - 1 / 6 -

2 PART 3- Bill No.3A - 2 / 6 -

3 PART 3- Bill No.3A - 3 / 6 -

4 PART 3- Bill No.3A - 4 / 6 -

5 PART 3- Bill No.3A - 5 / 6 -

TOTAL CARRIED TO SUMMARY OF PART 3A -

PART 3 - Bill 3A - 6/6

You might also like