1700 & 2700 Transmitters Ordering Catalogue

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Ordering information — Model 1700

Model Product description


1700 Micro Motion Coriolis MVD single variable flow transmitter
Code Mounting
R 4-wire remote mount transmitter
I Integral mount transmitter
B (1) 4-wire remote mount transmitter with 9-wire remote core processor (includes 10 ft. [3 m] each of 4-wire shielded PVC cable
and 9-wire shielded FEP cable)
C 9-wire remote transmitter (requires sensor with junction box; includes 10 ft. [3 m] 9-wire shielded FEP cable)
Code Power
1 18 to 100 VDC or 85 to 265 VAC; self switching
Code Display
1 Dual line display for process variables and totalizer reset, glass lens
2 Backlit dual line display for process variables and totalizer reset, glass lens
3 No display
5 Backlit dual line display for IIC ATEX, IECEx, and NEPSI rating; glass lens (2)
7 Backlit dual line display for process variables and totalizer reset, non-glass lens (3)
Code Output options
A Analog outputs: one mA; one frequency; RS485
D Intrinsically safe analog outputs: one mA, one frequency
Code Conduit connections
B 1/2-inch NPT — no gland
C (1) 1/2-inch NPT with brass/nickel cable gland
D (1) 1/2-inch NPT with stainless steel cable gland
E M20 — no gland
F M20 with brass/nickel cable gland
G M20 with stainless steel cable gland
Code Approvals
M Micro Motion Standard (no approval)
U UL
C CSA (Canada only)
A CSA C-US (US and Canada)
Z ATEX — Equipment Category 2 (Zone 1 — Increased safety terminal compartment)
F ATEX — Equipment Category 2 (Zone 1 — Flameproof terminal compartment)
(4)
P NEPSI — Equipment Category 2 (Zone 1 - Flameproof terminal compartment)
K (4) NEPSI — Equipment Category 2 (Zone 1 - Increased safety terminal compartment)
I IECEx Equipment Category 2 (Zone 1 — Flameproof terminal compartment)
Continued on next page

(1) Mounting code B is not available with conduit connection code C or D.


(2) Display code 5 is only available with Approval codes Z, F, P, K and I.
(3) Display code 7 is only available with Approval code M.
(4) Must be combined with language code M.

Micro Motion® Series 1000 and 2000 Transmitters 25


Ordering information — Model 1700 continued

Code Language
A Danish installation manual; English configuration manual
D Dutch installation manual; English configuration manual
E English installation manual; English configuration manual
F French installation manual; French configuration manual
G German installation manual; German configuration manual
H Finnish installation manual; English configuration manual
I Italian installation manual; English configuration manual
J Japanese installation manual; English configuration manual
M Chinese installation manual; Chinese configuration manual
N Norwegian installation manual; English configuration manual
O Polish installation manual; English configuration manual
P Portuguese installation manual; English configuration manual
S Spanish installation manual; Spanish configuration manual
W Swedish installation manual; English configuration manual
C Czech installation manual; English configuration manual
B Hungarian CE requirements document; English installation and configuration manuals
K Slovak CE requirements document; English installation and configuration manuals
T Estonian CE requirements document; English installation and configuration manuals
U Greek CE requirements document; English installation and configuration manuals
L Latvian CE requirements document; English installation and configuration manuals
V Lithuanian CE requirements document; English installation and configuration manuals
Y Slovenian CE requirements document; English installation and configuration manuals
Code Software options 1
Z Flow variable (standard)
Code Software options 2
Z No software options 2
(1)
C Meter verification, structural integrity method
S (2) Safety certification of 4–20 mA output per IEC 61508
Code Factory options
Z Standard product
X ETO product
Typical Model Number: 1700 I 1 1 A D M E Z C Z

(1) Requires transmitter to be connected to a sensor with an enhanced core processor.


(2) Available only with output codes A and D.

26 Micro Motion® Series 1000 and 2000 Transmitters


Ordering information — Model 2700

Model Product description


2700 Micro Motion Coriolis MVD multivariable flow and density transmitter
Code Mounting
R 4-wire remote mount transmitter
I Integral mount transmitter
B (1) 4-wire remote mount transmitter with 9-wire remote core processor (includes 10 ft. [3 m] each of 4-wire shielded PVC cable
and 9-wire shielded FEP cable)
C 9-wire remote transmitter (requires sensor with junction box; includes 10 ft. [3 m] 9-wire shielded FEP cable)
Code Power
1 18 to 100 VDC or 85 to 265 VAC; self switching
Code Display
1 Dual line display for process variables and totalizer reset, glass lens
2 Backlit dual line display for process variables and totalizer reset, glass lens
3 No display
5 Backlit dual line display for IIC ATEX, IECEx, and NEPSI rating; glass lens (2)
7 Backlit dual line display for process variables and totalizer reset, non-glass lens (3)
Code Output options
A Analog outputs: one mA; one frequency/discrete; RS485
B Analog outputs: one mA; two configurable I/O channels — default configuration of 2 mA, 1 FO
C Analog outputs: one mA; two configurable I/O channels — custom configuration
D Intrinsically safe analog outputs: two mA, one frequency/discrete
E Intrinsically safe FOUNDATION fieldbus H1 with standard function blocks (4 × AI, 1 × AO, 1 × Integrator)
G (4) PROFIBUS-PA
N (5) Non-incendive FOUNDATION fieldbus H1 with standard function blocks (4 × AI, 1 × AO, 1 × Integrator)
Code Conduit connections
B 1/2-inch NPT — no gland
C (1) 1/2-inch NPT with brass/nickel cable gland
D (1) 1/2-inch NPT with stainless steel cable gland
E M20 — no gland
F M20 with brass/nickel cable gland
G M20 with stainless steel cable gland
Code Approvals
M Micro Motion Standard (no approval)
U UL
C CSA (Canada only)
A CSA C-US (US and Canada)
Z ATEX — Equipment Category 2 (Zone 1 — Increased safety terminal compartment)
F ATEX — Equipment Category 2 (Zone 1 — Flameproof terminal compartment)
P (6) NEPSI — Equipment Category 2 (Zone 1 - Flameproof terminal compartment)
K (6) NEPSI — Equipment Category 2 (Zone 1 - Increased safety terminal compartment)
I IECEx Equipment Category 2 (Zone 1 — Flameproof terminal compartment)
Continued on next page

(1) Mounting code B is not available with conduit connection code C or D.


(2) Display code 5 is only available with Approval codes Z, F, P, K and I.
(3) Display code 7 is only available with Approval code M.
(4) Output code G is not available with Software Options 2 Code C.
(5) Output code N is not available with Approval codes U, C, and A.
(6) Must be combined with language code M.

Micro Motion® Series 1000 and 2000 Transmitters 27


Ordering information — Model 2700 continued

Code Language
A Danish installation manual; English configuration manual
D Dutch installation manual; English configuration manual
E English installation manual; English configuration manual
F French installation manual; French configuration manual
G German installation manual; German configuration manual
H Finnish installation manual; English configuration manual
I Italian installation manual; English configuration manual
J Japanese installation manual; English configuration manual
M Chinese installation manual; Chinese configuration manual
N Norwegian installation manual; English configuration manual
O Polish installation manual; English configuration manual
P Portuguese installation manual; English configuration manual
S Spanish installation manual; Spanish configuration manual
W Swedish installation manual; English configuration manual
C Czech installation manual; English configuration manual
B Hungarian CE requirements document; English installation and configuration manuals
K Slovak CE requirements document; English installation and configuration manuals
T Estonian CE requirements document; English installation and configuration manuals
U Greek CE requirements document; English installation and configuration manuals
L Latvian CE requirements document; English installation and configuration manuals
V Lithuanian CE requirements document; English installation and configuration manuals
Y Slovenian CE requirements document; English installation and configuration manuals
Code Software options 1
Z Flow & density variables (standard)
G (1) Enhanced density measurement
A (2) Petroleum measurement
X (3) ETO software option 1
Code Software options 2
Z No software options 2
C (4) Meter verification (structural integrity method)
W (5) Weights and measures custody transfer
D (6)(7) Weights & measures custody transfer & meter verification
A (1) Regulatory control suite: standard fieldbus function blocks plus 1 × PID function block
X (3) ETO software option 2
F (1) (4) Regulatory control suite: standard fieldbus function blocks plus 1 × PID function block and meter verification (structural
integrity method)
S (8) Safety certification of 4–20 mA output per IEC 61508
Code Factory options
Z Standard product
X ETO product
Typical Model Number: 2700 I 1 1 A D M E Z C Z
(1) Available only with output option code E or N.
(2) Not available with output option code G.
(3) Requires factory option X.
(4) Requires transmitter to be connected to a sensor with an enhanced core processor.
(5) Available only with output option codes A, B, or C.
(6) Available only with ELITE electronic interface code 2 or 4.
(7) Meter verification cannot be initiated in custody transfer secure mode. The custody transfer seal must be broken each time meter
verification is run.
(8) Available only with output option codes A, B, C, or D.

28 Micro Motion® Series 1000 and 2000 Transmitters

You might also like