2020092903481550v12a WZ5012L

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

High cost performance

programmable CNC adjustable


step-down power supply
module

(DIY desktop CNC small power


supply, you can easily do it
yourself)

1. highlights:
1.1 LCD can display input/output
voltage, output current/output
power/output capacity/output time;
1.2. CNC adjustment, accurate and
fast, can lower voltage, output
voltage can be adjusted at will from
0-50.00v, limit current 0-12.00a can
be adjusted at will;
1.3. the output end is poured
backward without burning;
1.4. The module can be set to
open/close by default;
1.5. Multiple software protection
mechanisms are available, and the
protection threshold is
adjustable.When the working
parameters of the module exceed the
protection threshold, the output
will be automatically closed.
1.6. Using synchronous rectification
technology, the conversion
efficiency is high: the efficiency is
more than 90%.
1.7. Increase heat sink, install fan,
strengthen heat dissipation.
2. Product parameters

model:WZ5005L display:LCD

Input voltage range:6-55.00V Input voltage resolution:0.01V

Output voltage range:0-50.00V Output voltage resolution:0.01V

Output current range:0-12.00A Output current resolution:0.01A

Output power range:0-600.0W Input voltage accuracy:±(1%+5)

Output voltage accuracy:±(0.3%+5) Output current accuracy:±(0.5%+5)

Typical value of output ripple:150mV Normal operating temperature range:


Peak value -10℃~40℃

Capacity measurement range : Statistical error of capacity energy:


0-999.9AH
±2%

Statistical time range:0-100 hour Depressurization mode:differential


pressure >0.05%+1V

The weight of nude: 199g Product size: panel79X43X42mm

Including packing:242g main board:106x76x40mm

Soft start: Yes


Protection mechanism:

Input undervoltage protection (5.8-50v


adjustable, default 5.8v)

Output overvoltage protection (0-51.00v


adjustable, default 51V)

Output over-current protection (0-12.10a


adjustable, default 12.10a)

Timeout protection (0-100h adjustable, off by


default)

Over capacity protection (0–999.9ah adjustable,


off by default)
3. Key description
C onst ant Output
cur rent indi cator

SW button
Rot ary
U/I button encoder
Note: after the product triggers the protection
mechanism, the output will automatically turn off,
the LCD will display the protection code, and
press any key to exit the protection interface.

4. Interface description
5. Method of use
5.1. Switch display parameters -- in the normal
interface, press SW to switch the display below the
display screen, and switch the display content
between current A power W capacity Ah time h.Long
press SW button to switch the uplink display on the
display screen and switch the display content
between input voltage IN output voltage OUT.

5.2. Set output voltage -- press U/I button in the


normal interface to enter the interface of setting
voltage constant current.It can be seen that a
certain digit of the output voltage value is flashing.
Rotate the encoder left and right to adjust the major
and minor.Short press the rotary encoder to choose
which bit of output voltage to set.After setting, press
U/I button 2 times to return to the normal
interface.Or automatically return to the normal
interface after stopping operation for 10s.
5.3. Set constant current value (that is, the
maximum current value allowed to output by the
module) -- press U/I button in the normal interface
to enter the setting voltage constant current
interface.Then press U/I button and switch to setting
constant current value. You can see a bit of the
setting constant current value flashing. Rotate the
rotary encoder left and right to adjust the major and
minor.Short press the rotary encoder to choose
which bit to set the constant current value.After
setting, press U/I to exit the setting voltage constant
current interface and return to the normal
interface.Or automatically return to the normal
interface after stopping operation for 10s.

5.4. Set the default on/off state of module


power-on -- long press U/I in the normal interface
to enter the parameter setting interface.You can see
that it shows "OPEN OFF" or "OPEN ON". "OPEN
OFF" means the output is turned OFF by default
when power is ON, and "OPEN ON" means the
output is turned ON by default when power is
ON.Long press rotate encoder to switch two
states.After setting, long press U/I to return to the
normal interface.

5.5. Setting of protection parameters on state


and threshold -- long press U/I to enter the
parameter setting interface in the normal
interface.Press SW until the protection you want
appears.LUP -- undervoltage protection
threshold;OUP -- overvoltage protection
threshold;OCP -- overcurrent protection
threshold;OAP -- ultra-capacity protection
threshold;OHP timeout protection threshold.Short
press rotate encoder to select which bit you want to
set the protection parameter.Long press the rotary
encoder to set the protection parameters on or off
(only timeout protection and supercapacity
protection can be set to turn on/off, and other
protection parameters are turned on by
default.).Rotate the encoder left and right to make
the parameters bigger and smaller.After setting,
long press U/I to return to the normal interface.
5.6. Calibration voltage and current -- press U/I
button to enter the parameter setting interface
under normal interface. Press SW key for a short
time until the interface with zero appears, with zero
+ out + a symbol. Press and hold the rotary encoder
to complete zero calibration. Short press SW button
until a parameter interface with CAL appears.The
calibration input voltage interface with the symbol
CAL+IN+V;The calibration output voltage interface
with the symbol CAL+OUT+V;The calibration output
current interface with the symbol
CAL+OUT+A.Rotate the encoder left and right to
adjust the size of parameters.After the adjustment is
completed, long press the rotary encoder to confirm
the adjustment is completed, and the parameter
value is no longer flashing.Long press U/I to return
to the normal interface.

Note: in order to ensure the accuracy of calibration,


calibration voltage -- above 12V can only be
started;Calibration current - start calibration only
when the current is above 1A.
6. Packing form

7. Cautions
7.1. The module input positive in + and negative in -
must not be reversed, and the module input in -
must not be short circuited with the output out -,
otherwise the module may be burnt out.
7.2. Please ensure that the power moment of the
power supply exceeds the required power of the
output load!

7.3. This module is a step-down module, the input


voltage should be higher than the output voltage,
and a certain margin should be reserved. For full
load output, the input voltage should be 55v.

7.4. High power use of this module, serious heating,


high temperature, be careful of scald! Please pay
attention to ventilation and heat dissipation when
using high power for a long time!

7.5. The module has input undervoltage protection


function. The default value is about 5.8v (can be set).
When the value is lower than this value, the output
will be automatically disconnected (note that the
voltage at the module port is lower than the
undervoltage protection threshold. When the input
current is relatively large, do not ignore the partial
voltage on the input wire).