0% found this document useful (0 votes)
111 views1 page

3phase-75k-G05 100 Deye

This document provides specifications for the SUN-75K-G05 solar inverter model from Deye. The inverter has a maximum DC input power of 150 kW from four MPPT circuits that can each handle 40 A. It can produce 75 kW of rated AC power at an efficiency as high as 98.7% with protections for grid faults, overcurrent, overvoltage and reverse polarity. Additional features include remote monitoring and parameter changes via interfaces like RS485, WiFi and LAN. The inverter measures 838x568x323 mm and weighs 73.7 kg.

Uploaded by

Daniel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views1 page

3phase-75k-G05 100 Deye

This document provides specifications for the SUN-75K-G05 solar inverter model from Deye. The inverter has a maximum DC input power of 150 kW from four MPPT circuits that can each handle 40 A. It can produce 75 kW of rated AC power at an efficiency as high as 98.7% with protections for grid faults, overcurrent, overvoltage and reverse polarity. Additional features include remote monitoring and parameter changes via interfaces like RS485, WiFi and LAN. The inverter measures 838x568x323 mm and weighs 73.7 kg.

Uploaded by

Daniel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Model SUN-75K-G05

Max. DC Input Power (kW) 150


Max. DC Input Voltage (V) 1000
Start-up DC Input Voltage (V) 250
MPPT Operating Range (V) ~
Max. DC Input Current (A) 40+40+40+40
Max. Short Circuit Current (A) 60+60+60+60
Number of MPPT / Strings per MPPT 6/4 /

Rated Output Power (kW) 75 75


Max. Active Power (kW) 82.5 82.5
Rated AC Grid Voltage (V) 220 / 380, 230 / 400
AC Grid Voltage Range (V) 277Vac~460Vac (this may vary with grid standards)
Rated Grid Frequency (Hz) 50 / 60 (Optional)
Operating Phase Three phase
Rated AC Grid Output Current (A) 87.8 101.5 108.7 108.7 115.9
Max. AC Output Current (A) 95.7 111.6 119.6 119.6 127.5
Output Power Factor >0.99
Grid Current THD <3%
DC Injection Current (mA) <0.5%
Grid Frequency Range 47~52 or 57~62 (Optional)

Max. Efficiency 98.7%


Euro Efficiency 98.3%
MPPT Efficiency >99%

DC Reverse-Polarity Protection Yes


AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote software upload Yes
Remote change of operating parameters Yes
Surge protection DC Type II / AC Type II

Size (mm) 838W×568H×323D


Weight (kg) 73.7
Topology Transformerless
Internal Consumption <1W (Night)
Running Temperature -25~65℃
Ingress Protection IP65
Noise Emission (Typical) <55 dB
Cooling Concept Smart cooling
Max. Operating Altitude Without Derating 2000m
Designed Lifetime >20 years
Grid Connection Standard IEC61727, IEC62116, IEC60068, IEC61683, VDE0126-1-1
Operating Surroundings Humidity 0-100%
Safety EMC / Standard IEC62109-1/-2, IEC61000-6-2, IEC61000-6-4, IEC61000-3-11, IEC61000-3-12

DC Connection MC-4 mateable


AC Connection IP65 rated plug
Display LCD 240 × 160
Interface RS485/RS232/Wifi/LAN

Add: No.26-30, South Yongjiang Road, Beilun, 315806, Ningbo, China


| Tel: 0086-0574-86120560 | E-mail: [email protected] | Web: www.deyeinverter.com