FTA MTPA4 en
FTA MTPA4 en
FTA MTPA4 en
MECHANICAL ANCHORS
Through-bolt anchor for heavy duty MT
PRODUCT INFORMATION
DESCRIPTION CHARACTERISTICS AND BENEFITS
Metallic anchor, with male thread, expansion • Easy installation.
by controlled torque.
• Use in cracked and non-craked concrete.
OFFICIAL DOCUMENTATION • Pre-installation or through the drill-hole of the fixture.
• CE-1404-CPR-2520. • Variety of lengths and diameters: flexibility in assembly.
• ETA 15/0145 option 1. • For static and quasi-static loads.
• Declaration of Performance DoP MTP-A4.
• Friction operation. Installation by controlled torque
SIZES • Use for medium loads.
M8x68 to M16x220. • Assessed for fire resistance RF30 to RF120.
• A4 Stainless steel (AISI 316).
DESIGN LOAD RANGE
• Available at INDEXcal.
From 6,00 to 23,3 kN (non-cracked).
From 3,3 to 16,67 kN (cracked).
MATERIALS
BASE MATERIAL Shaft: A4 Stainless steel.
Concrete class from C20/25 to C50/60 Washer: DIN 125, A4 Stainless steel.
cracked or non-cracked. Nut: DIN 934, A4 Stainless steel.
Clip: A4 Stainless steel.
1
TECHNICAL GUIDE
MT Through-bolt anchor for heavy duty
MECHANICAL ANCHORS
MECHANICAL PROPERTIES
M8 M10 M12 M16
INSTALLATION DATA
SIZE M8 M10 M12 M16
Tinst
2
TECHNICAL GUIDE
MECHANICAL ANCHORS
Through-bolt anchor for heavy duty MT
MTP-A4
Code INSTALLATION PRODUCTS INSTALLATION
Hammer drill
BHDSXXXXX Concrete Drill bits
MOBOMBA Blow pump 1 2 3
Resistances in C20/25 concrete for an isolated anchor, without effects of edge distance
or spacing
Characteristic Resistance NRk and VRk
TENSION SHEAR
NRk Non-cracked concrete [kN] 9,0 16,0 20,0 35,0 VRk Non-cracked concrete [kN] 11,9 18,8 27,4 51,0
NRk Cracked concrete [kN] 5,0 9,0 12,0 25,0 VRk Cracked concrete [kN] 11,9 18,8 27,4 51,0
NRd Non-cracked concrete [kN] 6,0 10,7 13,3 23,3 VRd Non-cracked concrete [kN] 9,2 14,5 21,1 39,2
NRd Cracked concrete [kN] 3,3 6,0 8,0 16,7 VRd Cracked concrete [kN] 9,2 14,5 21,1 39,2
Nrec Non-cracked concrete [kN] 4,3 7,6 9,5 16,7 Vrec Non-cracked concrete [kN] 6,5 10,3 15,1 28,0
Nrec Cracked concrete [kN] 2,4 4,3 5,7 11,9 Vrec Cracked concrete [kN] 6,5 10,3 15,1 28,0
Simplified version of the calculation method according to The calculation method is based on the following simplification:
ETAG 001, annex C. Resistance is calculated according to Different loads do not act on individual anchors, without
the data shown in assessment ETA 15/0145. eccentricity.
INDEXcal
• Influence of concrete strength.
For a more accurate calculation and to take more
• Influence of edge distance.
constructive provisions into account, we recommend
• Influence of spacing between anchors.
using our calculation program INDEXcal. It may be
• Influence of reinforcements.
easily downloaded from our website www.indexfix.
• Influence of base material thickness.
com
• Influence of load application angle.
• Valid for a group of two anchors.
3
TECHNICAL GUIDE
MT Through-bolt anchor for heavy duty
MECHANICAL ANCHORS
MTP-A4
TENSION LOADS
• Steel design resistance: NRd,s
• Pull-out design resistance: NRd,p = NºRd,p • c
• Concrete cone design resistance: NRd,c = NºRd,c • b
•
s,N
•
c,N
•
re,N
• Concrete splitting design resistance: NRd,sp = NºRd,c • b
•
s,sp
•
c,sp
•
re,N
•
h,sp
*Concrete splitting design resistance must only be considered for non-cracked concrete.
4
TECHNICAL GUIDE
MECHANICAL ANCHORS
Through-bolt anchor for heavy duty MT
Coefficients of influence
MTP-A4
Influence of concrete strength resistance in pul-out failure c
C 20/25 1,00
C 30/37 1,22
c
C 40/50 1,41
C 50/60 1,55
C 20/25 1,00
C 30/37 1,22
b
C 40/50 1,41
= fck,cube >
_1
b
C 50/60 1,55 25
5
TECHNICAL GUIDE
MT Through-bolt anchor for heavy duty
MECHANICAL ANCHORS
s [mm]
M8 M10 M12 M16
N 50 0,67
Invalid value
55 0,68 0,67
60 0,70 0,68 0,67
65 0,72 0,70 0,68
70 0,73 0,71 0,69 0,67
6
TECHNICAL GUIDE
MECHANICAL ANCHORS
Through-bolt anchor for heavy duty MT
7
TECHNICAL GUIDE
MT Through-bolt anchor for heavy duty
MECHANICAL ANCHORS
s [mm]
M8 M10 M12 M16
8
TECHNICAL GUIDE
MECHANICAL ANCHORS
Through-bolt anchor for heavy duty MT
MTP-A4
re,N
M8 M10 M12 M16
0,74 0,80 0,85 0,93
hef
*This factor only applies for a high density of reinforcements. If in the area of the anchor there are reinforcements
re,N
= 0,5 + _1
<
with a distancing of ≥ 150 mm (any diameter) or with a diameter ≤ 10 mm and a distancing of ≥ 100 mm, a fre,N = 200
1 factor may be applied.
MTP-A4
h,sp
h/hef 2,00 2,20 2,40 2,60 2,80 3,00 3,20 3,40 3,60 ≥3,68
fh 1,00 1,07 1,13 1,19 1,25 1,31 1,37 1,42 1,48 1,50
( )
2/3
h h
= _ 1,5
<
h,sp
2 hef
•
9
TECHNICAL GUIDE
MT Through-bolt anchor for heavy duty
MECHANICAL ANCHORS
MTP-A4
SHEAR LOADS
• Steel design resistance without lever arm: VRd,s
• Pry-out design resistance: VRd,cp = k • NºRd,c
• Concrete edge design resistance: VRd,c = VºRd,c • b • se,V
•
c,V
•
re,V
•
,V
•
h,V
VRd,s
Size M8 M10 M12 M16
V
Pry-out design resistance*
VRd,cp = k • NºRd,c
Size M8 M10 M12 M16
k 1 2 2 2
V
Concrete edge resistance
VRd,c = VºRd,c • b
•
se,V
•
c,V
•
re,V
•
,V
•
h,V
10
TECHNICAL GUIDE
MECHANICAL ANCHORS
Through-bolt anchor for heavy duty MT
Coefficients of influence
MTP-A4
Influence of concrete strength in concrete edge failure b
C 20/25 1,00
C 30/37 1,22
b
C 40/50 1,41
= fck,cube >
_1
b
C 50/60 1,55 25
c/hef 0,50 0,75 1,00 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,50 5,00
Isolated 0,35 0,65 1,00 1,40 1,84 2,32 2,83 3,38 3,95 4,56 5,20 5,86 6,55 7,26 8,00 9,55 11,18
c/hef 0,50 0,75 1,00 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,50 5,00
1,0 0,24 0,43 0,67 0,93 1,22 1,54 1,89 2,25 2,64 3,04 3,46 3,91 4,37 4,84 5,33 6,36 7,45
1,5 0,27 0,49 0,75 1,05 1,38 1,74 2,12 2,53 2,96 3,42 3,90 4,39 4,91 5,45 6,00 7,16 8,39
s/c
2,0 0,29 0,54 0,83 1,16 1,53 1,93 2,36 2,81 3,29 3,80 4,33 4,88 5,46 6,05 6,67 7,95 9,32
2,5 0,32 0,60 0,92 1,28 1,68 2,12 2,59 3,09 3,62 4,18 4,76 5,37 6,00 6,66 7,33 8,75 10,25
≥3,0 0,35 0,65 1,00 1,40 1,84 2,32 2,83 3,38 3,95 4,56 5,20 5,86 6,55 7,26 8,00 9,55 11,18
S
C C
V V
( ) ( )( ) ( )
1,5 1,5 1,5
c c s c
= = • 1+ • 0,5 ≤
se,V
hef se,V
hef 3• c hef
11
TECHNICAL GUIDE
MT Through-bolt anchor for heavy duty
MECHANICAL ANCHORS
c [mm]
M8 M10 M12 M16
40
45
C
50 0,69 Invalid value
55 0,68
60 0,67 0,70
( )
0,20
d
= 85 0,62 0,65 0,68 0,72
c,V
c 90 0,62 0,64 0,67 0,71
100 0,60 0,63 0,65 0,69
105 0,60 0,62 0,65 0,69
110 0,59 0,62 0,64 0,68
120 0,58 0,61 0,63 0,67
125 0,58 0,60 0,63 0,66
130 0,57 0,60 0,62 0,66
135 0,57 0,59 0,62 0,65
140 0,56 0,59 0,61 0,65
150 0,56 0,58 0,60 0,64
160 0,55 0,57 0,60 0,63
170 0,54 0,57 0,59 0,62
175 0,54 0,56 0,59 0,62
180 0,54 0,56 0,58 0,62
190 0,53 0,55 0,58 0,61
200 0,53 0,55 0,57 0,60
210 0,52 0,54 0,56 0,60
220 0,52 0,54 0,56 0,59
230 0,51 0,53 0,55 0,59
240 0,51 0,53 0,55 0,58
250 0,50 0,53 0,54 0,58
260 0,50 0,52 0,54 0,57
270 0,49 0,52 0,54 0,57
280 0,49 0,51 0,53 0,56
290 0,49 0,51 0,53 0,56
300 0,48 0,51 0,53 0,56
12
TECHNICAL GUIDE
MECHANICAL ANCHORS
Through-bolt anchor for heavy duty MT
Perimetral Perimetral
Without perimetral
reinforcements reinforcements with
reinforcements
≥ Ø12 mm brackets ≤ 100 mm
Non-cracked concrete 1 1 1
Cracked concrete 1 1,2 1,4
Angle, (º) 0° 10° 20° 30° 40° 50° 60° 70° 80° 90°
,V
1,00 1,01 1,05 1,13 1,24 1,40 1,64 1,97 2,32 2,50
0º
V 1
= _1
>
( )
,V
sin v 2
( cos v )2 +
90º
2,5
MTP-A4
h/c 0,15 0,30 0,45 0,60 0,75 0,90 1,05 1,20 1,35 ≥1,5
h,V
0,32 0,45 0,55 0,63 0,71 0,77 0,84 0,89 0,95 1,00 c
V
h
( )
0,5
h
= _ 1,0
>
h,V
1,5 • c
13
TECHNICAL GUIDE
MT Through-bolt anchor for heavy duty
MECHANICAL ANCHORS
MTP-A4
FIRE RESISTANCE
Characteristic Resistance*
TENSION SHEAR
M8 M10 M12 M16 M8 M10 M12 M16
*The safety factor for design resistance under fire exposure is =1 (in abscence of other national regulations). As a eresult the Characteristic Resistance is the same as Design
M,fi
Resistance.
RANGE
Maximum Maximum
Seismic Axle letter Seismic Axle letter
Code Size thickness Code Size thickness
assessment (length) assessment (length)
of fixture of fixture
APA408068 C1 M8 x 68 Ø8 4 A 100 600 APA410185 C1&C2 M10 x 185 Ø10 105 F 50 100
APA408115 C1 M8 x 115 Ø8 50 D 100 400 APA412145 C1&C2 M12 x 145 Ø12 45 C 50 200
APA408165 C1 M8 x 165 Ø8 100 G 50 200 APA412200 C1&C2 M12 x 200 Ø12 100 E 50 100
APA410090 C1&C2 M10 x 90 Ø10 10 A 100 400 APA416130 C1&C2 M16 x 130 Ø16 10 A 50 100
APA410105 C1&C2 M10 x 105 Ø10 25 B 50 300 APA416150 C1&C2 M16 x 150 Ø16 30 B 25 100
APA410115 C1&C2 M10 x 115 Ø10 35 C 50 300 APA416185 C1&C2 M16 x 185 Ø16 60 C 25 50
APA410135 C1&C2 M10 x 135 Ø10 55 D 50 300 APA416220 C1&C2 M16 x 220 Ø16 100 D 20 40
14