BATERIAS
BATERIAS
BATERIAS
BCI Cold Reserve Amp Hr. Add Water BCI Overall Dimensions Nominal Weight Nominal
Group Part Cranking Capacity Capacity Maintenance Length Width Height Wet Dry Acid to Fill
Size No. Amps" Minutes' Volts @ 20 Hrs. Construction Check Hours In (mm) In (mm) In (mm) Lb (kg) Lb (kg) Qt (liter)
8D 153-5720 1465 465 12 210 C MF 20.8 (528) 11.1 (282) 9.8 (249) 132 (60) — —
8D 101-4000 1400 400 12 190 LAC+ 1000 20.8 (528) 11.1 (282) 9.8 (249) 132 (60) 86 (39) 18.0 (17.0)
4D 153-5710 (new) 1365 425 12 200 C MF 20.8 (528) 8.8 (224) 9.8 (249) 119 (54) — —
4D 153-5700 1100 305 12 145 C MF 20.8 (528) 8.8 (224) 9.8 (249) 101 (46) — —
4D 9X-9730 1300 400 12 190 LAC+ 1000 20.8 (528) 8.6 (218) 9.8 (249) 119 (54) 81 (37) 14.8 (14.0)
4D 9X-9720 1000 275 12 140 LAC+ 1000 20.8 (528) 8.6 (218) 9.8 (249) 101 (46) 59 (27) 15.9 (15.0)
31 175-4390 950 180 12 90 C/S MF 13.0 (330) 6.8 (173) 9.4 (239) 60 (27) — —
31 175-4370 780 190 12 100 C/S** MF 13.0 (330) 6.8 (173) 9.4 (239) 60 (27) — —
31 175-4360 660 185 12 100 C/S** MF 13.0 (330) 6.8 (173) 9.4 (239) 60 (27) — —
31 115-2422 950 170 12 90 C MF 13.0 (330) 6.8 (173) 9.4 (239) 60 (27) — —
31 115-2421 950 170 12 90 C MF 13.0 (330) 6.8 (173) 9.4 (239) 60 (27) 44 (20) 6.6 (6.2)0
31 9X-3404 900 165 12 100 C MF 13.0 (330) 6.8 (173) 9.4 (239) 58 (26) — —
31 3T-5760 750 165 12 100 C MF 13.0 (330) 6.8 (173) 9.4 (239) 55 (25) — —
24 153-5656 650 110 12 52 C MF 10.2 (259) 6.8 (173) 8.9 (226) 39 (18) — —
74 153-5660 650 110 12 52 C* MF 10.2 (259) 6.8 (173) 8.2 (208) 39 (18) — —
58 175-4280 (new) 500 70 12 35 C MF 9.3 (236) 7.2 (183) 7.0 (178) 31 (14) — —
22 153-5690 765 210 6 90 LAC+ 1000 10.2 (259) 6.8 (173) 8.7 (221) 37 (17) 22 (10) 4.8 (4.5)0
Construction Notes:
Batteries have taper post design and are shipped wet except as:
LA—Low Antimony Design
LAC—Hybrid Design
C—Calcium Design
MF—Maintenance Free
S = Stud Terminals
+ = Dry Only
* = Side Terminals
** = Start/Cycling
" = For 30 seconds at 0 deg. F
' = Minimum of 25 amp output at 80 deg. F
& = Low Maintenance - Hybrid Construction ~ = Marine Starting " = For 30 seconds at 0 deg. F Ratings are subject to
# = Low Maintenance - Low Antimony Grids * = Side Terminals ' = Minimum of 25 amp output at 80 deg. F change without notice
+ = Maintenance Free - Calcium Grids ** = Stud Terminals Note: Wing Nut for 100-4081 and 8C-3628 is 2B-9498
@ = Deep Cycle - Antimony Grids *** = Offset Post with5 Horizontal Hole, Note: Wing Nut for 8C-3638 and 8C-3639 is 3B-0723
Stainless Steel ⁄16" Bolt and Hex Nut