Pile 300 MM Dia-Required Compressive Strength

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Concrete Pile 300 mm S-CONCRETE Version 2017.2.

2 Job #XXXX
© Copyright 1995-2017 by S-FRAME Software Inc.

S-CONCRETE 2017.2.2 (c) S-FRAME Software Inc.

File Name: C:\ ... Pile-300mm(Compression)-Required fck.SCO Summary


Status Borderline
Section Name Consultant Maximum 1.000
Concrete Pile 300 mm CBD V & T Util 0.249
N vs M Util 1.002
American Building Standards
ACI 318-11, "Building Code Requirements for Structural Concrete"
ACI 318R-11, "Commentary for ACI 318-11"

Design Aids, Manuals, and Handbooks


The Reinforced Concrete Design Manual in Accordance with ACI 318-11
"ACI Detailing Manual - 1994", ACI Committee 315, American Concrete Institute, 1994
"Manual of Standard Practice", Concrete Reinforcing Steel Institute, 2003

Section Dimensions Material Properties Gross Properties Effective Properties


Circular Column fc' = 32 MPa Zbar = 0 mm Ae = 70686 mm2
D = 300 mm fy (vert) = 420.0 MPa Ybar = 0 mm Ie (y-y) = 397608xE3 mm4
fy (ties) = 413.0 MPa Ag = 70686 mm2 Ie (z-z) = 397608xE3 mm4
Wc = 2450 kg/m3 Ig (y-y) = 397608xE3 mm4 Ase (Y) = 53014 mm2
Ws = 7850 kg/m3 Ig (z-z) = 397608xE3 mm4 Ase (Z) = 53014 mm2
Poisson's Ratio = 0.2 Ashear (Y) = 53014 mm2 Je = 795216xE3 mm4
Quantities (approx.) hagg = 20 mm Ashear (Z) = 53014 mm2
Concrete = 172 kg/m Es = 205000 MPa Jg = 795216xE3 mm4
Steel = 7.3 kg/m Ec = 23180 MPa
Primary = 3.1 kg/m Gc = 9658 MPa
Secondary = 4.2 kg/m fr = 3.52 MPa

Vertical Bars Spiral Miscellaneous


300 mm Diameter Column Y10 Spiral x 150 mm Clear Cover = 30 mm
5Y10 Vert
As = 393 mm2
Rho = 0.56 %
Tangential Splice

Factored Input Loads


Load N T Vz My Vy Mz Comment
Case/Combo (kN) (kNm) (kN) (kNm) (kN) (kNm)
1 -882.0 0.0 44.0 44.0 0.0 0.0

Factored Design Loads (with Minimum Moments):


Load Vz My Vy Mz Mres Theta
Case/Combo (kN) (kNm) (kN) (kNm) (kNm)
1 44.0 44.0 0.0 0.0 44.0 0º

N vs M Results Axial Utilization Moment Utilization


GLC 1 Nu = -882.0 kN Mu = 44.0 kNm Mn = 68.1 kNm
Status Borderline Message 1 ØNn (max) = -1235.7 kN ØMn = 43.9 kNm Mp = 68.2 kNm
Utilization 1.002 Utilization = 0.714 Utilization = 1.002
Maximum 1.000

CBD Page 1 #100 - 1234 Anywhere Place


Omer H October 25, 2022 AnyCity, AnyState
Ph: 555-1234 Fax: 555-4321 11:17 AM AnyCountry
Concrete Pile 300 mm S-CONCRETE Version 2017.2.2 Job #XXXX
© Copyright 1995-2017 by S-FRAME Software Inc.

Theta 0º

Shear and Torsion Utilization Shear Z-Direction Shear Y-Direction Torsion


GLC 1 bw = 300 mm Design Info Not Evaluated ØTcr = 20.7 kNm
Nu -882.0 kN d = 243 mm Tu = 0.0 kNm < 0.25 ØTcr
Vy(c+s) Util 0.000 Av = 157 mm2 Ignore Torsional Effects
Vz(c+s) Util 0.249 Lambda = 1.00
Vy&T(s) Util 0.000 Mu (y-y) = 44.0 kNm
Vz&T(s) Util 0.000 Vuz = 44.0 kN
Torsion Util 0.000 ØVsz = 78.8 kN
Status Acceptable ØVcz = 97.9 kN
Utilization 0.249 ØVnz = 176.7 kN
Maximum 1.000 ØVcz' = 97.9 kN
ØVnz' = 176.7 kN

Spiral Pitch for Shear/Torsion Maximum Shear Stress


Pitch 150.0 mm Stress 0.603 MPa
Maximum 300.0 mm Maximum 4.160 MPa
Status Acceptable Status Acceptable

Spiral Requirements
Rho 0.85 % Message 33
Rho (min) 1.96 % Warning
Diam. 10.0 mm
Diam. (min) 9.5 mm Acceptable
Spacers 2 req'd
Pitch (min) 37 mm Acceptable
Pitch 150 mm Message 15
Pitch (max) 86.2 mm Warning
D (core) 240 mm
A (core) 45239 mm2

Vertical Steel Area Status As/Ag Vertical Bar Splice Type


As 393 mm2 Message 35 0.56 % Tangential Splice
As (min) 707 mm2 Warning 1.00 % Status Acceptable
As (max) 2827 mm2 Acceptable 4.00 %

Vertical Bar Spacing Vertical Bar Diameter Minimum Number of Vertical Bars
#Bars 5 Specified db (vert) 10.0 mm #Bars 5 Specified
#Bars (max) 11.4 Allowed db (min) 15.9 mm #Bars 6 Required
Status Acceptable Status Warning Message 37 Status Warning Message 38

Vertical Reinforcing Horizontal Reinforcing


fy (min) 275.8 MPa fy (min) 275.8 MPa
fy (vert) 420.0 MPa fy (horz) 413.0 MPa
fy (max) 551.6 MPa fy (max) 413.7 MPa
Status Acceptable Status Acceptable

Concrete Strength Concrete Density


fc' (min) 17.2 MPa Wc (min) 1441.7 kg/m3

CBD Page 2 #100 - 1234 Anywhere Place


Omer H October 25, 2022 AnyCity, AnyState
Ph: 555-1234 Fax: 555-4321 11:17 AM AnyCountry
Concrete Pile 300 mm S-CONCRETE Version 2017.2.2 Job #XXXX
© Copyright 1995-2017 by S-FRAME Software Inc.

fc' 32.0 MPa Wc 2450.0 kg/m3


fc' (max) 68.9 MPa Wc (max) 2563.0 kg/m3
Status Acceptable Status Acceptable

List of Messages

Message 1 Borderline Axial Load and Moment Utilization equals or exceeds Maximum.
Clauses 10.2 and 10.3 of ACI 318

Message 15 Warning Spacing of Ties/Links or Spiral Pitch has exceeded the allowable.
Clause 7.10.5.2, 7.10.4.3, or 10.13.8.4 of ACI 318

Message 33 Warning Spiral Steel Ratio does not meet the Minimum required.
Clause 10.9.3 of ACI 318

Message 35 Warning Area of Vertical Steel provided does not meet the Minimum.
Clause 10.8.4, 10.9.1, 10.13.7.3, or 10.13.8.5 of ACI 318

Message 37 Warning Diameter of Vertical Bars does not meet the Minimum Required.
For a robust cage, use d >= 0.625 in

Message 38 Warning Number of Vertical Bars does not meet the Minimum Required.
Clause 10.9.2 of ACI 318