03 05 00ise
03 05 00ise
03 05 00ise
PART 1 GENERAL
A. Concrete Moisture Vapor Reduction Admixture (MVRA). Use for new concrete for the
following applications:
1. Slabs on grade.
2. Elevated slabs.
3. Roof decks.
4. Stair treads and landings.
1.3 REFERENCES
03 05 00 -1
of Concrete Subfloor Using Anhydrous Calcium Chloride.
7. ASTM F 2170 -Standard Test Method for Determining Relative Humidity in Concrete
Floor Slabs Using in situ Probes.
1.4 DEFINITIONS
A. Cementitious Materials: Portland cement alone or in combination with one or more of the
following:
1. Blended hydraulic cement.
2. Fly ash and other pozzolans.
3. Ground granulated blast-furnace slag.
4. Silica fume.
1.5 SUBMITTALS
B. Product Data:
1. Manufacturer's data sheets on each product to be used.
2. Preparation instructions and recommendations.
3. Storage and handling requirements and recommendations.
4. Typical installation methods.
C. Warranties
1. Sample lifetime warranty against flooring/coating failure due to concrete moisture
vapor emission (MVE).
2. Sample MVRA adhesion warranty.
3. Sample adhesive bond performance warranty from flooring adhesive manufacturer.
03 05 00 -2
minimum two years documented experience with projects of similar scope and complexity.
E. Source Limitations: Provide each type of product from a single manufacturing source to
ensure uniformity.
A. Store and handle in strict compliance with manufacturer's written instructions and
recommendations.
B. Protect from damage due to weather, excessive temperature, and construction operations.
1.10 WARRANTY
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer:
1. ISE Logik Industries, which is located at: 5635 Iron Works Road, Theodore, AL 36581;
Phone: 877-549-5159; Web: www.iselogik.com.
2. FullForce by ABC Polymer, which is located at: Helena Industrial Park, 545 Elm
Street, Helena, AL 35080; Phone: 205.620.9889; Web: www.FullForceSolutions.us.
A. Performance Requirements:
1. Hydraulic Conductivity: Project specific maximum of 6.0 E-8 cm/s per ASTM D 5084.
2. Toxicity: None.
3. Odor: None.
4. Flammability: None.
03 05 00 -3
5. Volatile Organic Compound (VOC) Content: 0 grams per liter.
6. Freeze Temperature: 32 degrees F (0 degrees C).
7. pH: 11.3.
2.3 ACCESSORlES
2.4 MIXES
A. Moisture Vapor Reducing Admixture (MVRA) for new concrete, slabs below grade, slabs on
grade, elevated slabs, roof deck, stair treads and landings, and exterior balconies.
C. Add MVRA at rate of 12 ounces per 100 pounds (355ml per 45 kg) of total cementitious
materials.
D. Replace mix water on one-for-one basis in amount equal to amount of MVRA added.
E. Add MRVA directly to freshly mixed concrete at end of the batch process with tail water.
F. Ready-Mixed Concrete:
1. Measure, batch, mix, and deliver concrete with MVRA in accordance with ASTM
C94/C94M.
2. Furnish batch ticket information showing dosage of MVRA.
G. Site Mixing:
1. Measure, batch, and mix concrete materials and concrete in accordance with ASTM
C94/C94M.
2. Add MVRA to where it makes direct contact with ready mix, then rotate drum of batch
truck on high for at least seven minutes prior to discharge.
H. Freshening onsite with held back mix water is acceptable if in accordance with ACI
guidelines and if amount does not exceed original water to cementitious material ratio.
1. Comply with instructions of Architect.
2. Comply with instructions of Design/Builder.
3. Comply with instructions of Structural Engineer.
03 05 00 -4
J. Use of other admixtures in same batch as MVRA is acceptable if each admixture is added
separately.
PART 3 EXECUTION
3.1 EXAMINATION
A. Do not begin installation until substrates have been properly constructed and prepared.
C. Protect and repair vapor retarder in accordance with ASTM E1643, ASTM F710, ACI
302.2R-06, and manufacturer's instructions.
3.2 INSTALLATION
C. Install, protect and repair sheet vapor retarder in accordance with to ASTM E1643, ASTM
F710, ACI 302.2R-06, and manufacturer's instructions.
D. Protect freshly placed concrete from premature drying and excessive cold or hot
temperatures. Comply with ACI 306R-10 for cold-weather protection and ACI 305R-10 for
hot-weather protection during curing.
E. Curing.
1. Cure concrete slabs to receive moisture sensitive coatings according to ACI 302.2R-
06 by one or more of following methods:
a. Moisture-retaining cover curing.
b. Self-dissipating curing compound.
c. Cure and seal curing compound.
2. Verify curing method in writing with MVRA manufacturer before placement of concrete
slabs containing MVRA product.
A. Project specific quality control process required by MVRA manufacturer necessary to convey
concrete moisture vapor emission flooring failure warranty and stand-alone adhesion
warranty.
B. Project team: Upon request, provide batch tickets indicating presence and dosage of MVRA
in mix.
END OF SECTION
03 05 00 -5