V11 SensorModule FRU
V11 SensorModule FRU
Replacement Instructions
Technical Support
If you need technical assistance, please contact KVH Technical Support:
Within the Continental U.S.A: North/South America, Australia: Europe, Middle East, Asia, Africa:
Phone: 1 866 701-7103 Phone: +1 401 851-3806 Phone: +45 45 160 180
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Important!
Gyros are sensitive to shock. Handle the sensor
module carefully to avoid damage.
Tools Required
This procedure requires the following tools:
• #1 Phillips screwdriver
• Phillips torque screwdriver set to 21 in.-lbs
• Flat-head jeweler’s screwdriver
• Flat-head torque screwdriver set to 5 in.-lbs
• 7/16" socket/ratchet or nut driver
WARNING
KVH, TracPhone, and the unique light-colored dome with dark contrasting baseplate are registered trademarks of KVH Industries, Inc.
All other trademarks are property of their respective companies. The information in this document is subject to change without notice. 1
No company shall be liable for errors contained herein. © 2012-2013 KVH Industries, Inc., All rights reserved. 54-0862 Rev. A1
b. Using a 7/16" socket/ratchet or nut driver, Figure 2: Service Hatch
unlock the three hex latches securing one of the
service hatches to the baseplate (see Figure 2).
Open the hatch.
NOTE: If you are unable to work through the hatch, you
may remove the radome instead.
Radome
Important!
Hex Latch (x3)
Do not use excessive force when loosening or
Baseplate
tightening the gyro cable connector’s retaining
screws. Hatch
2
Step 2 - Calibrate the Gyros Figure 4: Calibrating the Gyros
The sensor module’s gyros need to be calibrated to
work with the antenna’s main board.
Important!
Calibrate the gyros only while the vessel is
stationary in calm seas.