MONO SPLIT
INDOOR OUTDOOR
RAK-18PEB RAC-18WEB
RAK-25PEB RAC-25WEB
RAK-35PEB RAC-35WEB
RAK-50PEB RAC-50WEB
HITACHI
Specifications in this catalogue are subject to change without prior notice in order for HITACHI
to bring in the latest innovations to their customers
Whilst every effort is made to ensure that all dimensions and specifications are correct, any
printers’ error not rectified are outside the control of HITACHI, who cannot be held responsible
for the same
CONTENTS 1
CONTENTS
CONTENTS _______________________________________________________________________ 1
1 SPECIFICATIONS
NOTE:
1. The nominal cooling and heating capacity is the 2. The Sound Pressure Level is based on the following
combined capacity of the HITACHI standard split conditions:
system, and are based on the ISO 5151.
- 0.8 meter beneath indoor height center
Operation Conditions Cooling Heating
- 1 meter from Discharge grille
dB 27.0 °C 20.0 °C
Indoor Air Inlet Temperature
WB 19.0 °C The above data was measured in an anechoic
Outdoor Air Inlet dB 35.0 °C 7.0 °C chamber. Please take into consideration reflected
Temperature WB 6.0 °C sound of your specific site
Piping Length: 5.0 meters; Piping Lift: 0 meter
dB: Dry Bulb; WB: Wet Bulb
1-2 SPECIFICATIONS
NOTE:
1. The Sound Pressure Level is based on the following conditions:
- 1 meter from the unit front surface and 1 meter from floor level
The above data was measured in an anechoic chamber. Please take into consideration reflected sound of your
specific site
DIMENSIONAL DATA 2-1
2 DIMENSIONAL DATA
2.1. WALL TYPE: RAK-18PEB/25PEB/35PEB/50PEB
280
60
60
47 Air outlet Horizontal air deflector 47
5
5
190 400 190
70 70
Drain
When piping is drawn
from the left side,
exchange the drain
hose and the drain
cap.
Drain hose About
Drain cap connection port
About 108 About 370 70 Narrow pipe-(φ6.35)
Wide pipe-(φ9.52)
47
47
60
60
Vertical air deflector
2-2 DIMENSIONAL DATA
Unit: mm
CAPACITIES TABLE 3-1
3 CAPACITIES TABLE
3.1.1. RAK-18PEB/RAC-18WEB
3.1.2. RAK-25PEB/RAC-25WEB
3.1.3. RAK-35PEB/RAC-35WEB
3.1.4. RAK-50PEB/RAC-50WEB
Correction Factor for Cooling Capacity according to Correction Factor for Heating Capacity according to
Piping Length Piping Length
The cooling capacity should be corrected according to the The heating capacity should be corrected according to the
following formula: following formula:
CCA = CC x F HCA= HC x F
CCA: Actual Corrected Cooling Capacity HCA: Actual Corrected Heating Capacity
(kcal/h) (kcal/h)
CC: Cooling Capacity in the Performance HC: Heating Capacity in the Performance
Table (kcal/h) Table (kcal/h)
F: Correction Factor Based on the F: Correction Factor Based on the
Equivalent Piping Length Equivalent Piping Length
Models : RAK-50PEB/RAC-50WEB
Correction factor (humidity rate85% RH) 0.95 0.95 0.91 0.81 1.0 1.0 1.0
Correction Factor
Heating
capacity
Reduction in
capacity due to white
frost
Hour
1 cycle
NOTE:
The correction factor is not valid for special conditions such as snowfall or operation in a transitional period.
SOUND DATA 4-1
4 SOUND DATA
4.1. RAC-18WEB
COOLING
90
NC-70
80 NC-65
NC-60
NC-55
NC-50
70
NC-45
NC-40
NC-35
60
NC-30
Sound Pressure Level (dB)
NC-25
NC-20 48.6
50 44.3
NC-15 44.1
41.6
37.6
40
33.8 33.3
32
30
20
10
0
63 125 250 500 1000 2000 4000 8000
Octave band main wave length (Hz)
HEATING
90
NC-70
NC-65
80
NC-60
NC-55
NC-50
70
NC-45
NC-40
NC-35
60
NC-30
NC-25
Sound Pressure Level (dB)
NC-20 48.2
50 NC-15
43.3
40.5
38.4 36.9
40
33.6 32.6
28.3
30
20
10
0
63 125 250 500 1000 2000 4000 8000
4.2. RAC-25WEB
COOLING
90
NC-70
80 NC-65
NC-60
NC-55
NC-50
70
NC-45
NC-40
NC-35
60
NC-30
Sound Pressure Level (dB)
NC-25
NC-20 47.6
50 44.4 44.8
NC-15
40.7
38 37
40
33.4 33.2
30
20
10
0
63 125 250 500 1000 2000 4000 8000
Octave band main wave length (Hz)
HEATING
90
NC-70
80 NC-65
NC-60
NC-55
NC-50
70
NC-45
NC-40
NC-35
60
NC-30
Sound Pressure Level (dB)
NC-25 50.5
NC-20 47.2
50
NC-15 44.0
41.6 42.2 41.7 40.2
40
34.3
30
20
10
0
63 125 250 500 1000 2000 4000 8000
Octave band main wave length (Hz)
4.3. RAC-35WEB
COOLING
90
NC-70
80 NC-65
NC-60
NC-55
NC-50
70 NC-45
NC-40
NC-35
60 NC-30
NC-25
Sound Pressure Level (dB)
NC-20 48.2
50
NC-15 44.1
40.7
38.9
40 36.8 37.2
34
31.7
30
20
10
0
63 125 250 500 1000 2000 4000 8000
Octave band main wave length (Hz)
HEATING
90
NC-70
80 NC-65
NC-60
NC-55
NC-50
70
NC-45
NC-40
NC-35
60
NC-30
Sound Pressure Level (dB)
NC-25 51.3
NC-20 48.5
50
NC-15 44.5 43.8
40.7
38.4
40 36.5 36.0
30
20
10
0
63 125 250 500 1000 2000 4000 8000
Octave band main wave length (Hz)
4.4. RAC-50WEB
COOLING
90
NC-70
80 NC-65
NC-60
NC-55
NC-50
70 NC-45
NC-40
NC-35
60 NC-30
NC-25
Sound Pressure Level (dB)
NC-20 46.7
50 45.3
NC-15
39.6 41
36.5 37.9 36.5
40
33.1
30
20
10
0
63 125 250 500 1000 2000 4000 8000
Octave band main wave length (Hz)
HEATING
90
NC-70
80 NC-65
NC-60
NC-55
NC-50
70
NC-45
NC-40
NC-35
60 55.2
NC-30
51.6
Sound Pressure Level (dB)
NC-25
NC-20 48.5
50 45.8
NC-15 43.5
40.0
40 34.3 35.0
30
20
10
0
63 125 250 500 1000 2000 4000 8000
Octave band main wave length (Hz)
5 WORKING RANGE
Applicable models:
RAC-18WEB
RAC-25WEB
RAC-35WEB
RAC-50WEB
Cooling Heating
o o o o o o
working range min ( C) max ( C) rated ( C) working range min ( C) max ( C) rated ( C)
outdoor -10 43 35 outdoor -15 21 7
indoor 16 32 27 indoor 16 32 20
30 20
10
20
0
10
-10
0
-20
-10
-30
-20 -10 -5 0 5 10 15 20 25 30 35 40
-10 -5 0 5 10 15 20 25 30 35 40
Indoor Temperature
Indoor Temperature
ELECTRICAL DATA 6-1
6 ELECTRICAL DATA
RAK-18PEB 230,1,50 3.15 (C)3.37 (H)3.52 (C) 4.39 (H) 4.22 0.67 30
RAK-25PEB 230,1,50 3.15 (C)4.44 (H)4.65 (C) 5.61 (H) 5.43 0.67 30
RAK-35PEB 230,1,50 3.15 (C)5.39 (H)5.63 (C) 6.35 (H) 7.39 0.67 30
RAK-50PEB 230,1,50 3.15 (C)7.23 (H)7.56 (C) 9.13 (H) 11.96 0.67 30
VOL: Rated Unit Power Supply Voltage (V) RNC: Running Current (A)
Hz: Frequency (Hz) PH: Phase (φ)
STC: Starting Current (A) IPT: Input (W)
RAC-18WEB 220 ~ 230, 1, 50 15 207 253 3.52 4.39 580 4.22 620
RAC-25WEB 220 ~ 230, 1, 50 15 207 253 4.65 5.61 700 5.43 880
RAC-35WEB 220 ~ 230, 1, 50 15 207 253 5.63 6.35 1090 7.39 1100
RAC-50WEB 220 ~ 230, 1, 50 25 207 253 7.56 9.13 1560 11.96 1660
VOL: Rated Unit Power Supply Voltage (V) RNC: Running Current (A)
HZ: Frequency (Hz) PH: Phase (φ)
STC: Starting Current (A) IPT: Input (W)
NOTE:
1. The above compressor data is based on 100% capacity combination of indoor units at the rated operating frequency
2. This data is based on the same conditions as the nominal heating and cooling capacities.
3. The compressor started by an inverter, resulting in extremely low starting current.
WIRING DIAGRAM 7-1
7 WIRING DIAGRAM
8 REFRIGERANT CYCLE
RAK-18PEB
RAK-25PEB
RAK-35PEB
RAK-50PEB
BUTTONS FUNCTION
MODE Selector
Use this button to select the operationg mode. Every time you press this button, the mode will change
for (HEATING), (DEHUMIDIFYING), (COOLING) cyclically.
FAN SPEED Selector Button
This determines the fan speed. Every time you press this button, the airflow rate will change from
(This button allows selection of optimal or
preferred fan speed for each operation mode).
STOP button
Press this button to stop operation.
ECO button
Use this button to set the ECO mode.
POWERFUL button
Use this button to set the POWERFUL mode.
TEMPERATURE button
Value will change quicker when keep pressing.
2. Press [RESET] button on the same time. Release [RESET] button only, then release (OFF) and
Screen 1 Screen 2
Screen 3
5. Select (FAN SPEED) button to choose Heating Shift or Cooling Shift Mode (Screen 4).
Screen 4
NOTE:
1. There are total of 7 shift values ranging from -3 to 3.
2. The displayed shift value, and symbol on the remote controller display will be disappear
after 10 seconds
3. The changed shift value will remain unchanged after turned off the power.
4. If “0” is displayed on the remote controller display, it indicates the shift value is now at the initial setting.
CONTROL AND FUNCTION 9-3
a) Please ensure that the other indoor unit is OFF and the dip switch pin NO.6 at the indoor unit is ON to set the
indoor unit ID communication channel to channel B. (Please refer to Chapter 9.4 for more information
regarding the dip switch)
b) Open the cover/case of the remote controller and remove the PCB board as in Screen 1.
JSW1
Screen 1
c) Solder to short soldering point JSW1 on the PWB board’s surface as in Screen 2(before) to become Screen
3(after).
A new DIP Switch is available on the PWBs of the indoor unit that provide additional functions via the settings on the switches.
↕
OFF
DIP SW Label
Pin
Function Switch Position / Setting
No.
AUTO RESTART
1 OFF Enable ON Disable
function
DRY CONTACT
2 OFF Disable ON Enable
function
DRY CONTACT HI Input LO Input
3 OFF ON
Logic Select Active Active
NORMAL
4 HEATING / OFF OFF ON
(HEAT HEATING
COOLING ONLY COOLING ONLY
AND ONLY
5 MODE SELECT OFF ON OFF
COOL)
REMOCON ID SELECT SELECT ID
6 OFF ON
SELECT ID A B
10 OPTION LIST
BUTTONS FUNCTION
MODE Selector
Use this button to select the operationg mode. Every time you press this button,
the mode will change from
cyclically.
FAN SPEED Selector Button
This determines the fan speed. Every time you press this button, the airflow
rate will change from
(This button allows selection of optimal or preferred fan speed for
each operation mode).
ON/OFF button
Press this button to start operation. Press it again to stop operation.
SLEEP button
Use this button to set the SLEEP timer.
SET button
Timer setting reservation.
OFF button
Select the turn OFF timer.
ON button
Select the turn ON timer.
CANCEL button
Cancel timer reservation.
RAR-5G2 (SPX-RCDB) AUTO SWING (Vertical) button
Controls the angle of the horizontal air deflector.
ROOM TEMPERATURE setting button
Value will change quicke when keep pressing.
4. Press (ROOM TEMPERATURE) button to change the shift value (-3°C ~ 0 ~ 3°C).
NOTE:
1. There are total of 7 shift values ranging from -3 to 3.
2. The changed shift value will remain unchanged after turned off the power.
10-2 OPTION LIST
1. In case failure occurs to the air conditioner, the error code will constantly appear on the wired remote controller
display.
TIMER
LD301
LAMP CODE MEANING
BLINKING
BLINKING
- - - Normal
2 times - -
Outdoor unit is under forced operation
INDOOR
TIMER
LD301
LAMP CODE MEANING
BLINKING
BLINKING
LD301 Lit
LD302
BLINKING
79 I
4 times 9 times Wide pipe thermostat (indoor 3)
81 I
4 times 11 times Wide pipe thermostat (indoor 4)
CAUTION:
– DO NOT install the indoor unit, outdoor unit, controller HITACHI
and cable as such places as: PSC-6RAD
– where there is oil vapor and dispersion of oil
– where there is sulfuric environment (near the hot
springs)
– where there is a flammable gas
– where there is salty environment (near the sea)
– DO NOT install the indoor unit, outdoor unit, controller
and cable within approximately 3 meters from strong
electromagnetic wave radiators, such as medical
equipment. In case that the controller is installed in a Wiring outlet
place where there is electromagnetic wave direct-
radiation, shield the controller and cables by covering
with the steel box and running the cable through the
metal conduit tube. Bottom side
– In case that there is electric noise at the power source
for the indoor unit, provide a noise filter. 3) Installation procedure
10.2.2 INSTALLATION WORK a) When installing to the wall.
i) Fix the adaptor with 2 screws. Tapping screw
Before installation
is for metal surface, and other screw is for
Check the contents and the number of the accessories in wooden surface.
the packing.
50
Adaptor
With two UP
HITACHI 1.8m cables
Screw HITACHI
PSC-
6RAD PSC-6RAD
120
CAUTION:
– Turn OFF the power supply of the room air-conditioner
of the central control device when performing the wiring
work
– DO NOT run all the H-LINK cable or power supply
cable along the other signal cable, or malfunction may
occur due to the noise, etc. If it is required to run along
the other transmission cable, separate the cable more
than 30cm, or run the cable through the metal tube and
earth the tube.
– Follow local codes and regulations when performing
electrical wiring and earth wiring.
– Transmissions cable used in H-LINK shall be 2 cores
2 2
NOTE: cable (0.7mm to 1.25mm for model: VCTF, VCT,
– Consider the following points since the adhesiveness CVV, MVVX, CVVX, VVR, VVF) or 2 cores twisted pair
changes according to the environmental conditions cable (model: KPEV, KPEV-Spec). Total length of cable
(temperature, humidity etc) shall be below 1000mm.
– The adhesiveness is decreased when there is humidity – DO NOT use wire with more than 3 cores.
or oil.
Internal components and Wiring connections
– Warm the adhesive part and installation place of the
Check the contents and the number of the accessories in
two-sided tape to avoid the decrease of the
the packing.
adhesiveness in case the ambient temperature is low.
• Access
– DO NOT touch the adhesive part by fingers nor re- Open the cover by removing the ① and ② screws.
attach it many times. The adhesiveness has decreased
and the RAC adaptor may fall off.
– DO NOT apply any force within 24 hours after
installation. HITACHI
PSC-6RAD
• Wiring Connection
Connection with Room Air-Conditioner
i) Remove the front cover of the room air-
conditioner and the cover of electrical box.
ii) The cable attached with the connector of the
RAC adaptor shall be connected with the
connector of indoor PCB
OPTION LIST 10-7
Pin
Function Switch Position / Setting
No.
ON DRY CONTACT
2 OFF Disable ON Enable
function
↕ DRY CONTACT HI Input LO Input
3 OFF ON
Input Logic Active Active
OFF
DIP SW (DSW1)
• Please decide the type of dry contact you will be using and set the position of the DIP Switch No. 2 and 3 accordingly
[1] CHECK DRY CONTACT OF CARD KEY UNIT [2] SET THE POSITION OF DIP SWITCH
AIR CONDITIONER AIR CONDITIONER
POSITION CONDITION OF DIP SWITCH
Standby Operating
INITIAL CONDITION
REMOVE INSERT
(CARD KEY NO USE)
CARD KEY
(Door
Switch)
After all connection has been done as below diagram, ON the breaker and push ON button of wireless remote controller or
wired remote controller to operate the air conditioner unit.
• When the CARD KEY is in insert condition, the air conditioner operation is allowable by remote controller.
• When the dry contact switch on the Card Key Unit is open (refer to diagram below for contact type a), the unit stops to
operate (it takes 10 seconds to stop the unit operation after the dry contact switch on the card key turns off) and vice
versa.
• When the card key is removed from the Card Key Unit, the wireless remote controller cannot be used.
• When the card key is removed from the Card Key Unit, the wired remote controller LCD display is activated; however it
has no control over the unit.
• The suitable accessory Connecting Cord (accessory code#: SPX-WDC3) need to be used to connect the Card Key Unit’s
dry contact switch to the connector on the control board of the indoor unit. Please refer to Table 1 to select suitable
accessory code# for the concerning indoor model.
10-10 OPTION LIST
Example of wiring connection to Card Key Unit will be as below (reference only)
CARD KEY UNIT (Prepared by INSTALLER) AIR CONDITIONER INDOOR PCB
② Contact with sleeve
Dry contact
Card sensor
indicator
CN6
AC DIP SW (DSW1)
POWER
SUPPLY ① Connecting Cord to PCB:
SPX-WDC3
• CONNECTION EXAMPLE
i. Pin No. 3 of DIP SWITCH is set to OFF position (HI Input Active) for Dry Contact Type a
Connection
PWB
Connection
Card key unit
Insert Card: ON
Remove Card: OFF
SERIAL CONNECTION
All SW ON → OPERATION
Window
Close: ON
Open: OFF
ii. Pin No. 3 of DIP SWITCH is set to ON position (LO Input Active) for Dry Contact Type b
PARALLEL CONNECTION
All SW OFF → OPERATION Window
Close: OFF
Open: ON
Please refer to the actual manual supplied with the optional connecting cords SPX-WDC3 for more details.
HITACHI