Ti00392fen 1819

Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

TI00392F/00/EN/18.

19 Products Solutions Services


71457236

Technical information
Soliphant M
FTM50, FTM51, FTM52
Vibronic

Universal point level switch for fine-grained bulk


solids

Application
Soliphant M is a robust point level switch for silos with fine-grained or dusty bulk solids
even with a low bulk weight.
The various designs mean the device has a wide range of applications.
Many certificates are available for use in dust or gas incendive hazard areas.
FTM50:
Compact design for installation in any position. A wide range of applications thanks to
various variations e.g.
• Polished short fork with stainless steel housing (F15) and Tri-Clamp
• Coated standard fork with aluminum housing (F17) and flange
• Standard fork with 280 °C (536 °F) rating and aluminum housing (F13)
FTM51:
With extension pipe up to 4 m (13 ft) for installation in any position
FTM52:
With rope up to 20 m (66 ft) for installation from above
Typical applications:
Cereals, flour, cocoa, sugar, animal feed, detergents, dye powder, chalk, gypsum,
cement, plastic granules, fly ash
Your benefits
• Market leader in the area of level detection of bulk solids
• Functional safety up to SIL 2 as per IEC 61508
• No mechanically moving parts
• Insensitive to external vibrations and build-up
• Various electronic inserts
• Configurable density setting (bulk weight setting) and switching delay
• Process temperature up to 280 °C (536 °F)
• Choice of coated or polished sensor
• Warning in the event of impending device failure due to buildup or abrasion
Soliphant M FTM50, FTM51, FTM52

Table of contents

Function and system design . . . . . . . . . . . . . . . . . . . . . .3 Versions with extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20


Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Versions with temperature spacer . . . . . . . . . . . . . . . . . . . . . . 21
Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Surface refinement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Version with separate housing . . . . . . . . . . . . . . . . . . . . . . . . . 22
Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Cable specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Materials and surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Immunity to temperature change of connecting cable . . . . . . . 4
Connecting cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Display elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Operating elements of FEM51, FEM52, FEM54, FEM55,
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 FEM58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating elements of FEM57 . . . . . . . . . . . . . . . . . . . . . . . . . 26
Measuring range (detection range) . . . . . . . . . . . . . . . . . . . . . . 4 Sediment detection with FTM50 and FTM51 . . . . . . . . . . . . . 26
Input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Measuring frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Certificates and approvals . . . . . . . . . . . . . . . . . . . . . . 27
CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Other standards and guidelines . . . . . . . . . . . . . . . . . . . . . . . . . 27
Switch-on behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 RCM-Tick marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Fail-safe mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Pressure Equipment Directive 2014/68/EU (PED) . . . . . . . . . 28
Switching delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 CRN approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Switch behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 EAC conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Electronic insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 ASME B 31.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
FEM51 electronic insert (AC 2–wire) . . . . . . . . . . . . . . . . . . . . . 5 Process sealing as per ANSI/ISA 12.27.01 . . . . . . . . . . . . . . . 28
FEM52 electronic insert (DC PNP) . . . . . . . . . . . . . . . . . . . . . . . 7 Other certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
FEM54 electronic insert AC/DC with relay output) . . . . . . . . . 8 Functional safety (SIL validation) . . . . . . . . . . . . . . . . . . . . . . . 28
FEM55 electronic insert (8/16 mA) . . . . . . . . . . . . . . . . . . . . . . 9
FEM58 electronic insert (NAMUR H-L edge) . . . . . . . . . . . . . 10 Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . 29
FEM57 electronic insert (PFM) . . . . . . . . . . . . . . . . . . . . . . . . . 12
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Removing tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Weather protection cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Sliding sleeve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Rope shortening kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Functional safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Medium temperature limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Thermal shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Limiting medium pressure range . . . . . . . . . . . . . . . . . . . . . . . 16
State of aggregation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Grain size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Bulk weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Lateral load (static) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Tensile strength rope FTM52 . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Mechanical construction . . . . . . . . . . . . . . . . . . . . . . . 17
Housing and process connection . . . . . . . . . . . . . . . . . . . . . . . . 17
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

2 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Function and system design


Measuring principle A piezoelectric drive excites the tuning fork of Soliphant M to its resonance frequency. If medium
covers the tuning fork, the fork's vibrating amplitude changes (the vibration is damped). Soliphant M's
electronics compare the actual amplitude with a target value and indicate whether the tuning fork is
vibrating freely or whether it is covered by medium.

A A

t t

L00–FTM5xxxx–15–06–xx–xx–001

A: Amplitude
t: Time

Measuring system The measuring system is available either with compact instrumentation or separate instrumentation
with a switching unit. The following electronic versions are available:

Compact instrumentation 1
FEM51:
• Two-wire AC version
• Switch the load directly into the power supply cir-
cuit via the thyristor
FEM52:
• Three-wire DC version
• Switch the load via the transistor (PNP) and
separate connection
FEM54:
• Universal current version with relay output
• Switch the loads via 2 floating change-over con-


tacts (DPDT) L00–FTM5xxxx–15–05–xx–xx–000

1 Electronic version

Separate instrumentation with switching unit


For connecting to a separate switching unit or iso- 1
lating amplifier such as Nivotester:
Ex i
• FTL325N, FTL375N (NAMUR) or
• FTL325P, FTL375P (PFM) 2
FEM55:
Signal transmission 8/16 mA along two-wire
cabling:
FEM57:
• PFM signal transmission
• Current pulses superposed on the power supply
along the two-wire cabling

• Self-test from the switching unit without chan-


ging levels
FEM58:
L00–FTM5xxxx–15–05–xx–en–000
• Signal transmission H-L edge 2.2 to 4.8 / 0.4 to
1 Electronic version
1.0 mA to EN 50227 (NAMUR) along two-wire 2 Switching unit, PLC, isolating amplifier, segment coupler
cabling
• Checking of connecting cabling and other
devices by pressing a key on the electronic
insert

Endress+Hauser 3
Soliphant M FTM50, FTM51, FTM52

Cable specifications
Within the indicated standards and guidelines to interference immunity (see also "Electromagnetic
compatibility",  ä 14) a normal instrument cable is sufficient. If higher interference levels are pre-
sent, a shielded cable must be used.

Immunity to temperature In non-Ex applications the connecting cables must withstand the ambient temperature +5 K.
change of connecting cable For Ex applications, the specifications of the respective certificate (XA) must be observed  ä 30
Certificates.

Connecting cables • Electronic inserts: cross-section max. 2.5 mm(13 AWG); strand in ferrule to DIN 46228
• Protective ground in housing: cross-section max. 2.5 mm(13 AWG)
• Equipotential bonding connection on housing: cross-section max. 4 mm(11 AWG)

Cable entry Housing-specific: screw terminal on electronic insert.


Cable gland M20x1,5 for cable:
• Nickel-plated brass: ø7...10,5 mm (0.28...0.41 in)
• Plastic: ø5...10 mm (0.2...0.38 in)
• Stainless steel: ø7...12 mm (0.28...0.47 in)

Input
Measured variable Level (according to the mounting location and the overall length)

Measuring range • FTM50: overall length see,  ä 19


(detection range) • FTM51: overall length 300 to 4000 mm (11.8 to 157 in)
• FTM52: overall length 750 to 20000 mm (29.5 to 787 in)
The measuring range of Soliphant M depends on the medium, mounting location and fork length.
The detection range is located within the length of the fork.
Distinction between the forks:
• For light media:
Standard fork with a fork length of 155 mm (6.1 in) (bulk weight of the medium  10 g/l)
• For confined installation conditions, high lateral load or increased buildup:
Short fork with a fork length of 100 mm (3.94 in) (bulk weight of the medium  50 g/l)

Input signal • Probes covered => little to no vibrating amplitude


• Probes not covered large vibrating amplitude
Selectable frequency monitoring (diagnosis) for detection of abrasion and build-up.

Measuring frequency • Standard fork: approx. 140 Hz (in air)


• Short fork: approx. 350 Hz (in air)

Output
Galvanic isolation • FEM51, FEM52, FEM55: Between sensor and power supply
• FEM54: Between sensor, power supply and load
• FEM57, FEM58: See switching unit connected

Switch-on behavior When the power supply is switched on the switching status of the outputs corresponds to "signal on
alarm". The correct switching status is assumed after a maximum of 3 s.

Fail-safe mode Minimum/maximum residual current safety selectable on electronic insert.


(with FEM57 only at Nivotester).

4 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

MAX = maximum safety:


The output switches safety-oriented when the fork is covered (signal on alarm)
For use with overfill prevention for example.
MIN = minimum safety:
The output switches safety-oriented when the fork is uncovered (signal on alarm)
For use with dry running protection for example.

Switching delay 0.5 s when the sensor is covered.


Version 150 °C (302 °F): 1.5 s when the sensor is uncovered (1.0 s for short fork)
Version 230/280 °C (446/536 °F): 2 s when the sensor is uncovered (1.0 s for short fork)
Can be changed to 5 s for covering and uncovering.

Switch behavior Binary

Electronic insert
FEM51 electronic insert Power supply
(AC 2–wire)
• Supply voltage AC: 19 to 253 V
• Power consumption: < 1.0 W
• Residual current consumption (IR): < 4 mA; 5.5 mA for short fork (in switch-off moment < 1 mA for
100 ms)
• Short-circuit protection
• Separation voltage: 3.6 kV
• FEM51 overvoltage protection: overvoltage category II

Two-wire AC connection
Always connect in series with a load!
Check the following:
• the residual current consumption in blocked state.
• that for low voltage
– the voltage drop across the load is such that the minimum termi- 1 2
nal voltage at the electronic insert (19 V) when blocked is not
undershot.
– the voltage drop across the electronics when switched through is
observed (up to 12 V). 19 V
• when selecting the relay, pay attention to the holding power/rated
power (see "Connectable load"). R
*
* External load "R" must be connected F
** AC: Umax. 253 V, 50/60 Hz 1A

L1 N PE

** L00-FTM5xxxx-04-05-xx-xx-024

Endress+Hauser 5
Soliphant M FTM50, FTM51, FTM52

Output signal
IL = load current (switched through) Safety mode Level Output signal LEDs
green yellow red

IR = residual current (blocked) IL


1 2
MAX
= lit
IR
1 2
= flashes
IL
1 2
= unlit
MIN

* See also "Operating elements", 1


IR
2
 ä 25
Maintenance
required * IL / IR
1 2

Instrument failure
IR
1 2

L00–FTM5xxxx–04–05–xx–en–001

Signal on alarm
Output signal on power failure or in the event of device failure: IR

Connectable load
• For relays with a minimum holding power/rated power > 2.5 VA at 253 V (10 mA) or > 0.5 VA at
24 V (20 mA)
• For relays with a maximum holding power/rated power < 89 VA at 253 V or 8.4 VA at 24 V
• Voltage drop across FEM51 max. 12 V
• Residual current with blocked thyristor max. 4 mA (5.5 mA for short fork)
• Load current max. 350 mA (short-circuit proof)

6 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

FEM52 electronic insert Power supply


(DC PNP)
• DC voltage: 10 to 55 V
• Ripple: max. 1.7 V, 0 to 400 Hz
• Current consumption: max. 16 mA
• Power consumption: max. 0.86 W
• Reverse polarity protection/short-circuit protection
• Separation voltage: 3.6 kV
• FEM52 overvoltage protection: overvoltage category III

Three-wire DC connection with cable entry / M12 plug


• Preferably used with B
A FEM52
programmable logic controllers
(PLC)
• DI modules as per EN 61131-2.
• Positive signal at switching
output of the electronics (PNP).
1 2 3 1 2 3
(+)

M12
F 4 3
0.5A R

4 3 1
1 2

L+ L – L+ L –

L00-FTM5xxxx-04-05-xx-xx-027a

DC: U 10 V...55 V
A: With cable entry wired by customer (Ordering feature 80, options 2, 3, 4, 7)
B: With M12 plug wired at the factory (Ordering feature 80, option 1)

Output signal
IL = load current (switched through) Safety mode Level Output signal LEDs
green yellow red

IR = residual current (blocked) L+ IL +


1 3
MAX
= lit
IR
1 3
= flashes
L+ IL +
1 3
= unlit
MIN
IR
* See also "Operating elements",  ä 25 1 3

Maintenance
required * IL / IR
1 3

Instrument failure
IR
1 3

L00–FTM5xxxx–04–05–xx–en–007

Signal on alarm
Output signal on power failure or in the event of device failure: < 100 μA

Connectable load
• Load switched via transistor and separate PNP connection, max. 55 V
• Load current max. 350 mA (pulsed overload and short-circuit protection)
• Residual current < 100 μA (with transistor blocked)
• Capacitance load max. 0.5 μF at 55 V, max. 1.0 μF at 24 V
• Residual voltage < 3 V (with transistor switched through);

Endress+Hauser 7
Soliphant M FTM50, FTM51, FTM52

FEM54 electronic insert Power supply


AC/DC with relay output)
• Alternating voltage AC: 19 to 253 V, 50/60 Hz
DC voltage: 19 to 55 V
• Power consumption: max. 1.5 W
• Reverse polarity protection/short-circuit protection
• Separation voltage: 3.6 kV
• FEM54 overvoltage protection: overvoltage category II

Universal current connection with relay output (DPDT)


Note! FEM54
Please note the different voltage ranges for AC and
DC.

Output:
When connecting a device with high inductance, pro- 1 2 3 4 56 7 8
vide a spark arrester to protect the relay contact. A
fine-wire fuse (depending on the load connected)
protects the relay contact on short-circuiting. The
relay contacts switch simultaneously. F
0.5A
* When jumpered, the relay output works *
with NPN logic.
** See "Connectable load"
NO C NC NO C NC
a u r a u r
1 Relay outputs: normally open/closed
L1 N )
(NO, NC) L+ L– ** **
2 AC: U19 to 253 V, DC: U19 to 55 V
2 1
L00-FTM5xxxx-04-05-xx-xx-003

Output signal
= relay energized Safety mode Level Output signal LEDs
green yellow red
= relay de-energized

= lit MAX
3 4 5 6 7 8

= flashes
3 4 5 6 7 8

= unlit
3 4 5 6 7 8
* See also "Operating elements", MIN
 ä 25
3 4 5 6 7 8
Maintenance
required *

Instrument failure

3 4 5 6 7 8
L00–FTM5xxxx–04–05–xx–en–008

Signal on alarm
Output signal on power failure or in the event of device failure: relay de-energized

Connectable load
• Loads switched via 2 floating change-over contacts (DPDT)
• AC: I max. 6 A (Ex de 4 A), U max. 253 V; P max. 1500 VA, cos  = 1, P max. 750 VA, cos  > 0.7
• DC: I max. 6 A (Ex de 4 A) to 30 V, I max. 0.2 A to 125 V
• The following applies when connecting a functional low-voltage circuit with double isolation as per
IEC 1010: Sum of voltages of relay output and power supply max. 300 V

8 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

FEM55 electronic insert Power supply


(8/16 mA)
• DC supply voltage: 11 to 36 V
• Power consumption: < 600 mW
• Reverse polarity protection/short-circuit protection
• Separation voltage: 3.6 kV
• FEM55 overvoltage protection: overvoltage category II

Two-wire connection for separate switching unit with cable entry / M12 plug
For connecting to programmable logic controllers
(PLC), AI modules 4-20 mA to EN 61131-2. FEM55
Output signal jump from high to low current on
point level.

Use only power supply with safe galvanically isola-


tion (e.g. SELV).
1 2

Ex ia
EX

EX

U – 11 V
R R =
16.8 mA

U  11…36 V (DC)
U  11…35 V (DC)

L00-FTM5xxxx-04-05-xx-xx-000

U 11 to 36 e.g. PLC
With cable entry wired by customer (Ordering feature 80,
options 2, 3, 4, 7)

FEM55

1 2 3

M12

4 3

1 2
1 2

– +
L00-FTM5xxxx-04-05-xx-xx-000a

With M12 plug wired at the factory (Ordering feature 80,


option 1)

Endress+Hauser 9
Soliphant M FTM50, FTM51, FTM52

Output signal
 16 mA = 16 mA ±5 % Safety mode Level Output signal LEDs
green yellow red
 8 mA = 8 mA ±6 %
+ ~16 mA
2 1
= lit MAX
+ ~8 mA
= flashes 2 1

= unlit + ~16 mA
2 1

* See also "Operating elements",  ä 25 MIN


+ ~8 mA
2 1

Maintenance
+ 8/16 mA
required *
2 1

MAX OFF
MIN ON

3.6 mA

Instrument failure
+ 3.6 mA
2 1

L00–FTM5xxxx–04–05–xx–en–006

Signal on alarm
Output signal on power failure or in the event of device failure: < 3.6 mA

Connectable load
• R = (U - 11 V) / 16.8 mA
• U = connection DC voltage 11 V to 36 V (in wet location DC 11...35 V)

FEM58 electronic insert Note!


(NAMUR H-L edge) Only in combination with standard fork (fork length 155 mm (6.1 in)).

Power supply
• DC supply voltage: 8.2 V ±20 %
• Power consumption: < 8 mW at I < 1 mA; < 36 mW at I = 2.2 to 4.8 mA
• Separation voltage: 1.9 kV
• Connection data interface: IEC 60947–5–6

10 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Two-wire connection for separate switching unit with cable entry / M12 plug
For connecting to isolating amplifiers FEM58
acc. to NAMUR (IEC 60947-5-6), z.B. FTL325N or
FTL375N from Endress+Hauser.

H-L edge:
Output signal jump from high to low current on point 1 2

level.

Additional function:
Test key on the electronic insert. Ex ia EX
Pressing the key breaks the connection to the isola- H
ting amplifier. I EX
L
Note! – +
• For Ex d applications, the additional function can L00-FTM5xxxx-04-05-xx-xx-005

only be used if the housing is not exposed Isolating amplifier to IEC 60947-5-6 (NAMUR)
With cable entry wired by customer (Ordering feature 80,
to an explosive atmosphere. options 2, 3, 4, 7)
• Connecting to multiplexer:
Set clock time to min. 5 s.
FEM58

1 2 3

M12

4 3

1 2
1 2

– +
L00-FTM5xxxx-04-05-xx-xx-005a

With M12 plug wired at the factory (Ordering feature 80,


option 1)

Output signal
= lit Safety mode Level Output signal LEDs
green yellow red
= flashes
2.2 …
+ 4.8 mA
= unlit MAX
2 1

0.4 …
* See also "Operating elements",  ä 25 + 1.0 mA
2 1

2.2 …
+ 4.8 mA
2 1
MIN
0.4 …
+ 1.0 mA
2 1

Maintenance 0.4 …
required * + 4.8 mA
2 1

Instrument failure 0.4 …


+ 1.0 mA
2 1

L00–FTM5xxxx–04–05–xx–en–012

Endress+Hauser 11
Soliphant M FTM50, FTM51, FTM52

Signal on alarm
Output signal
in event of device failure: < 1.0 mA

Connectable load
• See "Technical Data" of the isolating amplifier connected according to IEC 60947–5–6 (NAMUR)
• Connection also to safety isolating amplifiers (I = 3 to 4.8 mA)

FEM57 electronic insert Power supply


(PFM)
• DC supply voltage: 9.5 to 12.5 V
• Power consumption: < 150 mW
• Reverse polarity protection/short-circuit protection
• Current consumption: 10 to 13 mA
• Separation voltage: 2.6 kV

Two-wire connection for separate switching unit / M12 plug


For connecting to Nivotester (see graphic) from FEM57
Endress+Hauser.
Output signal jump of PFM signal from high to low
frequency when sensor is covered. Switching bet-
ween minimum/maximum safety on the Nivotes-
ter. 1 2

Additional function "self test”:


After interruption of the power supply, a test cycle
is activated which checks the sensor and electronics
Ex ia EX
without any change in level.
For this purpose, the operating elements must be PFM
configured 50/ EX
as follows: 150 Hz
– +
7 8 1: FTL325P (1CH)
OFF
ON
OFF
ON
33 34 2: FTL325P (3CH)
37 38

d4 d2 3: FTL375P (1CH)
z4 z2 4: FTL375P (2CH)

The test is activated at the switching unit. z6 d6 5: FTL375P (3CH)


LEDs indicate the progress of the test. L00-FTM5xxxx-04-05-xx-xx-006

With cable entry wired by customer (Ordering feature 80,


options 2, 3, 4, 7)

FEM57

1 2 3

M12

4 3

1 2
1 2

– +
L00-FTM5xxxx-04-05-xx-xx-006a

With M12 plug wired at the factory (Ordering feature 80, option 1)

12 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Output signal
= lit Safety mode Level Output signal LEDs
(PFM) green yellow red
= flashes 150 Hz

= unlit
50 Hz
* See also "Operating elements",  ä 25

Maintenance 150 Hz
required *

OFF OFF
ON ON

0 Hz

Instrument failure 0 Hz

L00–FTM5xxxx–04–05–xx–en–009

Signal on alarm
Output signal on power failure or in the event of device failure: 0 Hz

Connectable load
• Floating relay contacts in connected switching unit Nivotester (see drawing above)
• For contact load, see the Technical Data of the switching unit

Installation
Installation instructions Orientation FTM50
60 (2.36)
max.

~20°
~250 (9.84)

1
(7.87)
~200

mm (in)
L00-FTM5xxxx-11-06-xx-xx-004

1 Protective cover (provided by the customer)

Endress+Hauser 13
Soliphant M FTM50, FTM51, FTM52

Orientation
FTM51, FTM52

1 2 3

L00–FTM5xxxx–11–06–xx–xx–001

1 Sliding sleeve
2 FTM51
3 FTM52
4 FTM51 with supporting tube (not included in the delivery)
A Clearance
B Maximum nozzle length: = L Sensor length – 145 mm (5.71 in) for short fork
= L Sensor length – 200 mm (7.87 in) for standard fork

Environment
Ambient temperature range –50 °C to +70 °C (-58 °F to +158 °F);
With F16 housing: -40 °C to +70 °C (-40 °F to +158 °F)

Storage temperature -50 °C to +85 °C (-58 °F to +185 °F)

Climate class Climate protection as per DIN IEC 68, Part 2-38, Fig. 2a

Degree of protection • Housing F15, F16, F17, separate housing: IP66/IP67, NEMA4X
• Housing F13, T13, F27: IP66/IP68, NEMA4X/6P

Vibration resistance To EN 60068-2-64: 0.01 g/Hz

Shock resistance To EN 60068-2-27: 30 g

Electrical safety IEC 61010, CAN/CSA-C22.2 No. 61010-1-04


US standard UL 61010-1, 2nd Edition

Electromagnetic • Interference emission to EN 61326, Equipment Class B,


compatibility • Interference immunity to EN 61326; Annex A (Industrial) and NAMUR Recommendation NE21
(EMC).

14 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Process
Medium temperature limits Non-hazardous area and Ex d + DIP certificates
(Ex ia certificates see Seite 30, "Certificates")

NOTICE
Permitted ambient temperature Ta at housing depending on the process temperature Tp in the
container.

Ta Ta FTM52 FTM50/51 **
70 (158)

50 (122)

Tp –40 (–40)
80 (176)
0 (32)
–50 (–58) 0 (32) 50 (122) 100 (212) 150 (302) Tp
90 (194)

F16* –40 (–40)


–50 (–58)

L00-FTM5xxxx-05-05-xx-xx-003

* Restriction to –40 °C with F16 housing


** Additional temperature range for sensors (FTM50, FTM51) with temperature spacer

High temperature (only FTM50, FTM51)

Ta
*** **
70 (158)

Ta 50 (122)

Tp
0 (32)
–50 (–58) 0 (32) 50 (122) 230 (446) 280 (536) Tp
190 (374)

F16* –40 (–40)


–50 (–58)

L00-FTM5xxxx-05-05-xx-xx-005

* Restriction to –40 °C with F16 housing


** Additionally utilizable temperature range when using the temperature spacer outside the insulation "1"
*** Antistick coating possible up to max. 230 °C
2 Insulation

Thermal shock resistance • Maximum 120 K


• At high temperature 260 K

Endress+Hauser 15
Soliphant M FTM50, FTM51, FTM52

Limiting medium pressure –1 to 25 bar (362.5 psi)


range
Maximum Working Pressure (MWP)
• FTM50/51: 25 bar (362.5 psi)
• FTM52: 2 bar (29 psi) (6 bar (87 psi) for Ex d, Ex de and FM/CSA XP)
The specified range may be reduced by the selected process connection.
The pressure rating (PN) specified on the flanges refers to a reference temperature of 20 °C (68 °F), for
ASME flanges to 100 °F. Observe pressure-temperature dependency.
The pressure values permitted at higher temperatures can be found in the following standards:
• EN 1092-1: 2001 Tab.18
With regard to their stability-temperature property, the materials 1.4404 and 1.4435 are grouped
together under 13E0 in EN 1092-1, Tab. 18. The chemical composition of the two materials can be
identical.
• ASME B 16.5a - 1998 Tab. 2-2.2 F316
• ASME B 16.5a - 1998 Tab. 2.3.8 N10276
• JIS B 2220
Burst pressure
FTM50/51: 100 bar (1450 psi)

State of aggregation Solids

Grain size  10 mm (0.39 in)

Bulk weight Depends on the density setting on the electronic insert:


• Standard fork:  10 or 50 g/l
(for light media)
• Short fork:  50 or 200 g/l
(for confined installation conditions, high lateral load or increased buildup)

Lateral load (static) The following graphic shows the maximum permitted lateral load F in N (lbf) in relation to the length
L in mm (in).

A
1000 (224.80)
900 (202.32) F
L
800 (179.84)
B
750 (168.60)
700 (157.36)
650 (146.12)
600 (134.88)
550 (123.64)
C
500 (112.40)
450 (101.16)
F

400 (89.92)
350 (78.68)
300 (67.44)
250 (56.20)
200 (44.96)
150 (33.72)
100 (22.48)
50 (11.24)
0
500 (19.7)

1000 (39.4)

1500 (59.1)

2000 (78.7)

2500 (98.4)

3000 (118)

3500 (138)

4000 (157)

4500 (177)

5000 (197)

5500 (217)

6000 (236)
0

L
L00-FTM5xxxx-05-05-xx-en-001

A Short fork, sensor Ø36 mm (1.42 in),  ä 19


B Short fork, sensor Ø43 mm (1.69 in),  ä 19;
C Standard fork, sensor Ø43 mm (1.69 in),  ä 19.

Tensile strength rope FTM52 3000 N (lbf)

16 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Mechanical construction
Housing Polyester housing F16
and process connection ø85 (3.35) max. 76 (2.99)
Process connection:
• R 1½

100 (3.94)
• 1½ NPT
• 1¼ NPT

43 (1.69)
22.5 (0.89)
mm (in)
L00–FTM5xxxx–06–05–xx–xx–008

Stainless steel housing F15 ø 76 (3.0)


max. 64 (2.52)
Process connection:

113* (4.45*)
Tri-Clamp

94 (3.7)
28 (1.1)
22,5 (0.9)

* Cover with glass insert mm (in)


L00-FTM5xxxx-06-05-xx-xx-049

Aluminum housing F17


max.60 (2.36) max.65 (2.56)

Process connection: ø 80 (3.15)


Flange
119* (4.69*)

105 (4.13)
43 (1.69)

22,5 (0.9)

* Cover with glass insert mm (in)


L00-FTM5xxxx-06-05-xx-xx-050

Endress+Hauser 17
Soliphant M FTM50, FTM51, FTM52

Aluminum housing F13 (Ex d)


max. 60 (2.36) max. 65 (2.56)
(Adaption to sensor threaded.)
ø 80 (3.15)
Process connection
• Flange
• R1½

133* (5.24)

118 (4.65)
• 1½ NPT
• 1¼ NPT
Stainless steel housing F27 (Ex d)
(Adaption to sensor threaded.)
Process connection
• Flange

51** (2.01)
53 (2.09)
• R1½
• 1½ NPT
• 1¼ NPT
* Cover with glass insert
(only for aluminum housing F13)
** For Tri-Clamp 36 mm (1.42 in)
22,5 (0,89)

mm (in)
L00-FTM5xxxx-06-05-xx-xx-051

Aluminum housing T13 (Ex de)


max. 65 (2.56) max. 97 (3.82)
With separate connection compart-
ment.
Process connection
148* (5.83*)

• R1½

135 (5.31)
• 1½ NPT
• 1¼ NPT
With Ex d(e) for FTM51 and FTM52:
for flange and thread dimensions see
the previous graphic
41** (1.61**)

• R 1½
• 1½ NPT
• 1¼ NPT

* Cover with glass insert 22,5 (0.9)


** For Tri-Clamp 16 mm (0.63 in) mm (in)
L00-FTM5xxxx-06-05-xx-xx-052

18 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Dimensions Compact version FTM50


Dimensions: mm (in)

Process connec- Code Dimensions Accessories Pressure


tion Temperature
(for FTM50/51)

1½ NPT GJ 24.5 200(7.87)1)/145(5.71)2) max. 25 bar


ANSI B 1.20.1 (0.96) (362.5 psi)
max. 280 °C (536 °F)
R 1½ GG
EN 10226

(1.69)
ø43
50
L00–FTM5xxxx–06–05–xx–xx–004

1½ NPT GX 2) max. 25 bar


24.5 145 (5.71)
ANSI B 1.20.1 (0.96) (362.5 psi)
max. 150 °C (302 °F)

(1.42)
ø36
50
L00-FTM5xxxx-06-05-xx-xx-006

1¼ NPT GK max. 25 bar


24.5 145 (5.71)2)
ANSI B 1.20.1 (362.5 psi)
(0.96)
max. 150 °C (302 °F)

(1.42)
ø36

45
L00-FTM5xxxx-06-05-xx-xx-005

Flange Seal See nominal pressure


ANSI B 16.5 A# according to of flange, however
EN 1092-1 B# 1) 2) design max. 25 bar
215 (8.46) /160 (6.3)
(DIN 2527 B) K# installed on (362.5 psi)
JIS B2220 site max. 280 °C (536 °F)
FDA approval
available
ø43 (1.69)

L00-FTM5xxxx-06-05-xx-xx-013

Tri-Clamp 2" Clamping ring max. 16 bar (232 psi)


215(8.46)1)/160(6.3)2)
ISO 2852 TD and max. 120 °C (248 °F)
front seal
installed on max. 2 bar (29 psi)
site max. 150 °C (302 °F)
FDA approval
(1.69)
ø43

available
L00-FTM5xxxx-06-05-xx-xx-014

43 43 36
(1.69) (1.69) (1.42)
(3.94)
(3.94)

100
100
(6.1)
155

15
(0.59) 39 32
(1.54) (1.26)
4 39
(0.16) (1.54)
L00-FTM5xxxx-06-05-xx-xx-030

Dimensions of standard fork and short fork


1)
Length of standard fork
2)
Length of short fork

Endress+Hauser 19
Soliphant M FTM50, FTM51, FTM52

Rope version FTM52

Ex d(e), XP: 105 (4.13)

Ex d(e), XP: 169 (6.65)


129 (5.08)
65 (2.56)
D2

204 (8.03)
D1
D1

140 (5.51)
D2

mm (in)
L00-FTM5xxxx-06-05-xx-xx-015

Process connec- GJ, GG, A#, B#, K#, TD GK, GX


tion:

ø D1 (mm [in]) 43 (1.69) 36 (1.42)

ø D2 (mm [in]) 37 (1.46) 37 (1.46)

Versions with FMI51 (pipe): Dimensions depend on process connection and selected pipe extension
extensions FTM52 (rope): Dimensions depend on process connection and selected rope extension

Process • 1½ NPT Flange and Tri-Clamp


connection: • 1¼ NPT
• R 1½

FTM51 FTM52 FTM51 FTM52


L

L
X

L
L

X
X

L00-FTM5xxxx-06-05-xx-xx-016 L00-FTM5xxxx-06-05-xx-xx-017 L00-FTM5xxxx-06-05-xx-xx-018 L00-FTM5xxxx-06-05-xx-xx-022

L = Length (from lower edge of thread), X = fork length


For further information on the overall length and fork length see "Measuring range (detection range)",  ä 4.
Diameter of pipe extension FTM51: see dimensions of FTM50,  ä 19.

20 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Versions with Length and version depend on temperature and certificate:


temperature spacer
150 °C (302 °F) 230 °C (446 °F) 280 °C (536 °F)

L
L
L
L

L
L

L00-FTM5xxxx-06-05-xx-xx-019 L00-FTM5xxxx-06-05-xx-xx-020 L00-FTM5xxxx-06-05-xx-xx-021

mm (in) 150 °C (302 °F) 230 °C (446 °F) 280 °C (536 °F)
L: for housing F15, F16, F17 145 (5.71) -- 175 (6.89) 215 (8.46)

L: for housing F13, F27, T13 145 (5.71) 165 (6.5) 165 (6.5) 205 (8.07)

Certificate A, 1, 2, 3, 4, 7, 8, 5, 6, H, Z
Not relevant Not relevant
C, D, F, X

Surface refinement

Electropolishing Device with thread Device with flange

2
1

L00-FTM5xxxx-06-05-xx-xx-031 L00-FTM5xxxx-06-05-xx-xx-002

1: Electropolished fork (0.76 μm)


2: Fork and pipe electropolished as far as welding seam on process connection (0.76 μm)
NOTICE

‣ In the area of the welding seams, the roughness is not defined due to the production process.
‣ In the area of the fork base a deviation of the surface roughness can occur.

Coating

1
2

3
L00-FTM5xxxx-06-05-xx-xx-032 L00-FTM5xxxx-06-05-xx-xx-003

1: Fork coated
2: Fork and pipe coated as far as welding seam on process connection
3: Fully coated

Endress+Hauser 21
Soliphant M FTM50, FTM51, FTM52

Version with separate Applications:


housing For high ambient temperatures and applications with confined installation locations (e.g. filling nozzle
applications). The cable between the separate housing and sensor can be shortened at the customer's.

EX
Tp
A
Ta1 Ta2 C

L00-FTM5xxxx-15-06-xx-en-002

A: Zone 1, Zone 21; B: Length max. 6 m (20 ft); C: Zone 0, Zone 20

Ta1 Ta2 Tp

FTM50/51 70 °C (158 °F) 120 °C (248 °F) Versions: 150 °C (302 °F), 230 °C (446 °F), 280 °C (536 °F)

FTM52 70 °C (158 °F) 80 °C (176 °F) 80 °C (176 °F)

Housing extension heights for wall and pipe mounting


The wall holder unit forms part of the scope of supply for device versions with a separate housing.

~61 (2.4) B ~75 (2.95) B r3)

108 (4.25)2)
1)

H21)
H2
H1

H1

ø34 (1.34)
H3

H3

3)
r
ø21 (0.83)
mm (in)
L00-FTM5xxxx-06-05-xx-xx-023

1) Cover with glass insert;


2) - With optional temperature spacer up to 150 °C (302 °F) 108 + 145 = 253 mm (4.25 + 5.71 = 9.96 in)
- With high-temperature version 230 °C (446 °F)283 mm (4.25 + 6.89 = 11.1 in)
- With high-temperature version 280 °C (536 °F)mm (4.25 + 8.46 = 12.7 in)
3) The bending radius is r  100 mm (3.94 in); with armored tube r 75 mm (2.95 in)

Dimen- Housing
sions
Polyester Stainless Aluminum Aluminum (F13) Aluminum (T13)
mm (in)
(F16) steel (F15) (F17) Stainless steel Separate connection com-
(F27) partment

B 76 (2.99) 64 (2.52) 65 (2.56) 65 (2.56) 97 (3.82)

H1 155 (6.1) 166 (6.54) 160 (6.3) 243 (9.57) 260 (10.2)

H2 -- 185 (7.28) 174 (6.85) 258 (10.2) 273 (10.7)

H3 41 (1.61) 62 (2.44)

22 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Weights Depends on type; see last column on "Additional weight" in the ordering information

Materials and surfaces Material specifications as per AISI and DIN-EN.

Surface roughness

NOTICE

‣ In the area of the welding seams, the roughness is not defined due to the production process.
‣ In the area of the fork base a deviation of the surface roughness can occur.
Electropolished for simple cleaning and to avoid build-up and corrosion.
Choice of surface roughness (version => type): Ra < 0.76 m

Parts in contact with process


• Process connection and extension pipe: 316L (1.4404, 1.4435)
• Tuning fork: 316L (1.4404, 1.4435)
• Flanges: 316L (1.4435 or 1.4404)
• PTFE coating: prevents buildup, FDA compliant
• ETFE coating: prevents corrosion
• FTM52: PUR/silicone for rope insulation, PBT

Parts with no process contact


• Seal between process connection/housing: EPDM
• Ground terminals outside on housing: 304 (1.4301), 316L (1.4404)
• Polyester housing F16: PBT-FR with PBT-FR cover or with PA12 transparent cover,
– Cover seal: EPDM
– Nameplate glued: polyester film (PET)
– Pressure compensation filter: PBT-GF20
• Stainless steel housing F15: 316L (1.4404)
– Cover seal: silicone/PTFE
– Safety claw: 316L (1.4404)
– Pressure compensation filter: PA, VMQ/VA
– Nameplate labeling directly on the device
• Aluminum housing F17/F13: EN-AC-AlSi10Mg, plastic-coated,
– Cover seal: EPDM
– Safety claw: nickel-plated brass
– Pressure compensation filter (only F17): silicone
– Nameplate: 304 (1.4301)
• Stainless steel housing F27: 316L (1.4435)
– Cover seal: FVMQ (optional: EPDM seal available as spare part)
– Safety claw: 316L (1.4435)
– Nameplate: 316L (1.4404)
• Aluminum housing T13: EN-AC-AlSi10Mg, plastic-coated,
– Cover seal: EPDM
– Safety claw: nickel-plated brass
– Nameplate: 304 (1.4301)
• Cable gland versions:
– Polyamide (PA)
– Nickel-plated brass
– 316L (1.4435)
– M12 connector (nickel-plated brass)

Endress+Hauser 23
Soliphant M FTM50, FTM51, FTM52

Operability
Display elements

NOTICE
The switch settings in the following graphics are in the as-delivered state.

FEM51
• Green LED lit:
Indicates operational status
• Yellow LED lit: MAX OFF
Indicates switching status
1 MIN ON

• Red LED L1 N 2
FEM51
AC
– flashing: flashes alternately with green LED
if maintenance is required U ~ 19...253V AC
50/60Hz
– lit: indicates device failure I max : 350mA

L00–FTM5xxxx–03–05–xx–xx–001

FEM52
• Green LED lit:
Indicates operational status
• Yellow LED lit: MAX OFF
Indicates switching status
1 MIN ON

• Red LED 3
FEM52
L+ L- DC PNP
– flashing: indicates maintenance is required
– lit: indicates device failure U 10...55V DC
I max : 350mA

L00–FTM5xxxx–03–05–xx–xx–002

FEM54
• Green LED lit:
Indicates operational status
• Yellow LED lit: MAX OFF
Indicates switching status
3 5 MIN ON
U~ –
19... 55V DC
• Red LED 4 3 5 68
19... 253V AC FEM54
L1 N
– flashing: indicates maintenance is required 4 7

– lit: indicates device failure

L00–FTM5xxxx–03–05–xx–xx–004

FEM55
• Green LED lit:
Indicates operational status
• Yellow LED lit: MAX OFF
Indicates switching status I = 16mA
MIN ON

• Red LED U 11...36V DC FEM55


– flashing: indicates maintenance is required - + 8/16mA

– lit: indicates device failure

L00–FTM5xxxx–03–05–xx–xx–005

24 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

FEM57
• Green LED lit:
Indicates operational status
• Yellow LED lit: FEM57
Indicates covered status
• Red LED PFM OFF OFF
- + ON ON
– flashing: indicates maintenance is required
– lit: indicates device failure

L00–FTM5xxxx–03–05–xx–xx–007

FEM58
• Green LED flashing:
Indicates operational status
• Yellow LED lit: FEM58
Indicates switching status NAMUR
• Red LED IEC 60947-5-6
MAX OFF
- + MIN ON
– flashing: flashes alternately with green LED
if maintenance is required
– flashing: indicates device failure > 2,2mA

L00–FTM5xxxx–03–05–xx–xx–008

NOTICE
If the test key is pressed this breaks the cable connection.

Operating elements of Factory setting:


FEM51, FEM52, FEM54,
FEM55, FEM58

MAX OFF
MIN ON

L00-FTM5xxxx-19-05-xx-xx-001

Switch for safety mode

MAX Overfill prevention

MIN Dry running protection

Switch for switching delay

0.5 s when covered


150 °C (302 °F): 1.5 s when uncovered (short fork 1 s)
230/280 °C (446/536 °F): 2 s when uncovered (short fork 1 s)

5 s when covered, 5 s when uncovered

Switch for bulk weight/density setting

50 g/l standard fork, 200 g/l short fork (high bulk weight)

10 g/l standard fork, 50 g/l short fork (low bulk weight)

Switch for diagnosis

OFF Diagnosis of abrasion and buildup switched OFF

ON Diagnosis of abrasion and buildup switched ON


• For additional density setting to high bulk density:
abrasion and build-up are indicated per LED at the electronic insert only
• For additional density setting to low bulk density:
output of "signal on alarm" for abrasion and build-up

Endress+Hauser 25
Soliphant M FTM50, FTM51, FTM52

Operating elements of Factory setting:


FEM57

OFF OFF
ON ON

L00–FTM5xxxx–19–05–xx–xx–002

Switch for switching the self-test on or off

OFF Self-test switched off

ON At the same time, switching delay 0.5 s when covered,


density setting for low bulk weight and diagnostics on (see also Seite 12):
Self-test performed when voltage returns.

Switch for switching delay

0.5 s when covered


150 °C (302 °F): 1.5 s when uncovered (short fork 1 s)
230/280 °C (446/536 °F): 2 s when uncovered (short fork 1 s)

5 s when covered, 5 s when uncovered

One switch for bulk weight/density setting

Standard fork: 50 g/l


Short fork: 200 g/l (high bulk weight)
Standard fork: 10 g/l (low bulk weight)
Short fork: 50 g/l

One switch for diagnosis


OFF Diagnosis of abrasion and buildup switched OFF

ON Diagnosis of abrasion and buildup switched ON


• For additional density setting to high bulk density:
abrasion and build-up are indicated per LED at the electronic insert only
• For additional density setting to low bulk density:
output of "signal on alarm" for abrasion and build-up

Sediment detection with Detection of solids under water


FTM50 and FTM51
Only sediment is detected.
Water-like liquids or entrained substances are
not detected.

The standard version of FTM52 is not suitable


OFF
for immersion due to the IP67 rope seal! ON
Version with IP68 available on request. H2O

L00-FTM5xxxx-19-05-xx-xx-014

26 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Certificates and approvals


CE mark The measuring system is in conformity with the statutory requirements of the applicable EC Directives.
These are listed in the corresponding EC Declaration of Conformity along with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.

Ex approval FEM51, FEM52, FEM54, FEM55:


• Explosion protection for potentially explosive gas/air mixtures:
Ex d, Ex de, XP, intrinsically safe sensor circuit Ex ia, IS
• Explosion protection for potentially explosive dust/air mixtures:
Dust ignition-proof as per EN 50281-1-1, DIP as per EN 61241-0
FEM57, FEM58:
• Explosion protection for potentially explosive gas/air mixtures:
Ex ia, IS (intrinsically safe power supply + intrinsically safe sensor circuit)
• Explosion protection for potentially explosive dust/air mixtures:
Ex ia D, IS (intrinsically safe power supply + intrinsically safe sensor circuit)
See "Ordering information",  ä 29 and "Documentation",  ä 30.
Your Endress+Hauser distributor will supply you with information about hazardous area versions that
are currently available.
All explosion protection data are given in a separate documentation (see "Documentation") which is
available upon request. Copies of certificates available upon request.

F16 F15 F17 F13 / F27 T13 housing Separate


housing housing housing housing with separate housing
connection
compartment

Dust ignition-proof X
X X X X X
(except II 1/2 D)

Ex ia X X X X X X

Ex nA/nL/nC X X X X X X

Ex d – – – X X X

Ex de – – – – X X
IP66/67 X X X – – X

IP66/68 – – – X X –

Recommended in event
of severe external – – – X X X
vibrations

Goretex filter X X X – – –

Other standards and Other standards and guidelines that were taken into consideration in designing and developing
guidelines Soliphant M FTM50, FTM51, FTM52:
• Low Voltage Directive (73/23/EEC)
• DIN EN 61010 Part 1, 2001
Protection Measures for Electrical Equipment for Measurement, Control, Regulation and Laboratory
Procedures
Part 1: General requirements
• EN 61326
Electrical Equipment for Measurement, Control and Laboratory Use
EMC requirements

Endress+Hauser 27
Soliphant M FTM50, FTM51, FTM52

RCM-Tick marking The supplied product or measuring system meets the ACMA (Australian Communications and Media
Authority) requirements for network integrity, interoperability, performance characteristics as well
as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic
compatibility are met. The products are labelled with the RCM- Tick marking on the name plate.

A0029561

Pressure Equipment Directive Pressure instruments with permitted pressure ≤ 200 bar (2 900 psi)
2014/68/EU (PED)
Pressure instruments with permitted pressure ≤ 200 bar (2 900 psi) Pressure instruments with a
flange and threaded boss that do not have a pressure-bearing housing do not fall within the scope of
the Pressure Equipment Directive, irrespective of the maximum permitted pressure.

Reason:
According to Article 2, point 5 of EU Directive 2014/68/EU, pressure accessories are defined as
"devices with an operational function and having pressure-bearing housings".
If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber
of its own), there is no pressure accessory present within the meaning of the Directive.

CRN approval CRN-approved devices are fitted with a separate plate bearing the registration number
No.: 0F10907:5C ADD1.

EAC conformity The measuring system meets the legal requirements of the applicable EAC guidelines. These are
listed in the corresponding EAC Declaration of Conformity together with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the EAC mark.

RoHS The measuring system complies with the substance restrictions of the EU Directive on the restriction
of the use of certain hazardous substances 2011/65/EU (RoHS 2).

ASME B 31.3 Design and materials in accordance with ASME B31.3. The welding seams are through-penetration
welded and comply with ASME Boiler and Pressure Vessel Code Section IX and EN ISO 15614-1.

Process sealing as per ANSI/ North American practice for the installation of process seals.
ISA 12.27.01 Soliphant M instruments are designed by Endress+Hauser according to ANSI/ISA 12.27.01 as single
seal devices with annunciation, allowing the user to waive the use and save the cost of installing exter-
nal secondary process seals in the conduit as required by the process sealing sections of ANSI/NFPA
70 (NEC) and CSA 22.1 (CEC). The instruments comply with the North American installation practice
and provide a very safe and cost-saving installation for pressurized applications with hazardous fluids.
Please refer to the Safety Instructions (XA) of the relevant device for further information  ä 30ff.

Product Type Maximum process pres- Marking Approval


sure
Soliphant M FTM50-D/F/H##... 25 bar (362.5 psi) Single Seal FM, CSA
FTM51-D/F/H##... 25 bar (362.5 psi) Single Seal FM, CSA
FTM52-D/F/H##... 2 bar (29 psi) Single Seal FM, CSA

Other certificates • Material certificate as per EN 10204/3.1 for all wetted parts,
• AD2000 on request
• TSE Certificate of Suitability
The following applies to wetted device components:
– They do not contain any materials derived from animals.
– No additives or operating materials derived from animals are used in production or processing.

Functional safety (SIL valida- Use in safety systems requiring functional safety to SIL2 in accordance with IEC 61508. See "Documen-
tion) tation",  ä 30.

28 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

Ordering information
Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com → Click "Corporate"
-> Select country → Click "Products"→ Select product using the filters and search field → Open
product page → The "Configuration" button to the right of the product image opens the Product
Configurator.
• Endress+Hauser Sales Center: www.addresses.endress.com

NOTICE
Product Configurator - the tool for individual product configuration

‣ Up-to-the-minute configuration data


‣ Depending on the device: Direct input of measuring point-specific information such as measuring
range or operating language
‣ Automatic verification of exclusion criteria
‣ Automatic creation of the order code and its breakdown in PDF or Excel output format
‣ Ability to order directly in the Endress+Hauser Online Shop

Accessories
Removing tool For Soliphant M FTM50, FTM51, FTM52.
Order No.: 71026213

Weather protection cover For Soliphant M FTM50, FTM51, FTM52


with F13, F17 and F27 housing. F13, F17, F27

(4 10
Order No.: 71040497

)
.33
~1
PA

(4.02)
102
162
(6.3
8)

L00-FTM5xxxx-03-05-xx-xx-009

Endress+Hauser 29
Soliphant M FTM50, FTM51, FTM52

Sliding sleeve Only for Soliphant M FTM51 with pipe diameter


ø80 (3.15) M6x25
d=43 mm (1,69 in), see ordering information,
5
ordering feature "Process connection", options GG,
GJ and ordering feature "Material", options A, 2, 5.
70

(2.95)
~75
For pressurized containers up to 5 bar (362.5 psi).

C
Sliding sleeve version:
• G2 B
DIN ISO 228/I A
Order No.: 52024631
• 2NPT
ANSI B 1.20.1
D
Order No.: 52024630

NOTICE
Suitable for switch point configuration! E

mm (in)
L00–FTM5xxxx–03–05–xx–xx–002

A G2 (316L)
B 2NPT (316L)
C For G2: 24 mm (0.94 in); for 2NPT: 27.5 mm (1.08 in)
D MWP = 25 bar (362.5 psi)
E Tp = max. 280 °C (536 °F)

Rope shortening kit Only for Soliphant M FTM52.


Order No.: 52024632

L00-FTM5xxxx-00-00-xx-xx-001

Documentation
NOTICE
You can find the following supplementary documentation on our product pages at
www.endress.com.

Operating Instructions • Soliphant M FTM50, FTM51 KA00229F


• Soliphant M FTM52 KA00230F
• Soliphant M FTM51, sliding sleeve, pressurized: KA00239F
• Soliphant M FTM52, rope shortening KA00231F
• Soliphant M FTM50, FTM51, FTM52
– Separate housing; installation and shortening instructions
(housing side) KA00264F
– Separate housing and armored tube; installation and shortening
instructions (housing side) KA00265F
– Separate housing; removing and installing the sensor KA00273F

Certificates ATEX
• ATEX II Ex i 1D, 1/2D, 1G, 1/2G XA00305F
• ATEX II Ex i (X) 1D, 1G XA00319F

30 Endress+Hauser
Soliphant M FTM50, FTM51, FTM52

• ATEX II Ex d/Ex de 1D, 1/2D Ex t, 1/2G XA00306F


• ATEX II Ex t 1/2D, 1/3D XA00307F
• ATEX II Ex t, Ex n 3D, 3G XA00331F
NEPSI
• NEPSI Ex t XA00393F
• NEPSI Ex ia XA00393F
• NEPSI Ex d, Ex t XA00395F
IECEx
• IECEx Ex ia XA00391F
• IECEx Ex t XA00392F
• IECEx Ex d, Ex de, Ex t XA00633F
INMETRO
• INMETRO Ex t XA01336F
• INMETRO Ex d, Ex de, Ex t XA01354F
EAC
• EAC Ex d, Ex t Ga/Gb, Da/Db XA01590F
FM
• FM IS, NI XA01337F
CSA
• CSA IS, NI XA01248F
• CSA XP, DIP XA01042F

Functional safety • Soliphant M + electronic insert FEM51 SD00203F


• Soliphant M + electronic insert FEM52 SD00204F
• Soliphant M + electronic insert FEM54 SD00205F
• Soliphant M + electronic insert FEM55 SD00208F
• Soliphant M + electronic insert FEM57 + Nivotester FTL325P SD00207F
• Soliphant M + electronic insert FEM58 SD00206F

Endress+Hauser 31
71457236

www.addresses.endress.com

You might also like