Binder 1234

Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

Material Transfer Order

‫ م‬. ‫ م‬. ‫المتحدة العمال الحديد ذ‬ MTO Ref : USW-MTO-5339


Plot No 39 A, KHI - A5, KIZAD,
MTO Date : 10-06-2023
PO Box No. 93026, Abu Dhabi, UAE. Tel : +971 2 5868930

TRN : 100212317000003

Client : ALEC ENGINEERING AND CONTRACTING LLC


JC Ref : JC2219

Address: ALI KHALFAN RASHED AL MUTAWA, AL DAHAERI BUILDING,


UNIT NO. 205, P.O BOX : 45336 , ABU DHABI, UAEClient ALEC-CBC300-WS-COM-SLO-
VO Ref :
003817
Client TRN: 100026349900003
TP9 ZURICH (SEA WORLD
Project Ref :
Place of Supply : Abu Dhabi ABU DHABI)

Sl.
DESCRIPTION Unit Qty Remarks
No.

FABRICATION AND SUPPLY OF STAINLESS STEEL ESCALATOR


1 NOS 48.0
BOLLARDS WITH ROD

FABRICATION AND SUPPLY OF STAINLESS STEEL ESCALATOR


2 NOS 24.0
BOLLARDS WITHOUT ROD

Receiver's Signature For United Steel Works LLC


USW-ACC-FRM-004-MTO
Fitup inspection report
United Steel Works LLC
Project: Sea world Client:- ALEC Report No:- USW-ALEC-FT-001 Date: 22.03.2023

Drawing No.SHOP DRAWING Location:- KIZAD , USW FACTORY Rev: 00


ITEM : ESCALATOR BOLLARD
Joint
Sl No Material. (Item / part No.) Thickness Weld Type Root Gap Bevel Angle Alignment Straightness Remarks
Number

PIPE 141 SCH 40 - 6MM


1 6mm SW 01 Fillet NA NA OK OK 72 NOS
THICK PLATE

2 PIPE 141 SCH 40 - 12MM 12mm SW 02 Fillet NA NA OK OK 72 NOS


THICK PLATE

PIPE 141 SCH 40 - 30MM 6mm SW 03 Fillet NA NA OK OK 48 NOS


3
ROD

Note:

For INSPECTED BY - USW QC CONTRACTOR CONSULTANT

Name Niaz shanavaz

Sign

Date
22.03.2023

401-USW-QC-FR-008
Weld Visual &
NDT Inspection Report
Project: SEA WORLD Client:- ALEC Report No:- USW-ALEC-WIR-001 Date 24.03.2023

Drawing No: Shop darwing Location: KIZAD , USW FACTORY Rev:0


ITEM : ESCALATOR BOLLARD
Weld Type
Material Joint
Sl No (FILLET, Thickness Welder No WPS No Remarks
(Item or Part No.) FPBW,PPBW) Number
1 PIPE141XSCH 40-PLATE6MM FILLET 6mm SW01 W-2021 WPS-SS-001
2 PIPE141XSCH 40-PLAT12MM FILLET W2021
12mm SW02 WPS-SS-001
3 PIPE 141 SCH 40-30MM ROD FILLET 6mm SW03
W2021 WPS-SS-001

Inspection Category Result Inspection Category Result Inspection Category Result


Weld Size: OK Under Cut: NIL Surface Crack: NIL
Weld Profile: OK Porosity: NIL Reinforcement: OK
Note: The above mentioned weld joint found satisfactory as per AWS D1.1 The holding time has been started NDT (UT & MPI) is carried out in accordance with the holding period.

Remarks:

For USW QC
US ALEC CONSULTANT
Name Niaz shanavaz

Sign

Date
24.03.2023

401-USW-QC-FR-005
2/9/23, 1:17 PM MTC 990 3.jpg

https://mail.google.com/mail/u/0/#inbox/FFNDWNXqqwWNDHCgJTgZlJSsPPdMvbbb?projector=1&messagePartId=0.1 1/1
2/9/23, 1:17 PM MTC 990 3.jpg

https://mail.google.com/mail/u/0/#inbox/FFNDWNXqqwWNDHCgJTgZlJSsPPdMvbbb?projector=1&messagePartId=0.1 1/1
KEY PLAN N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

A
B
QIBLA
C
D
E
F
G
H POLOR
J
K ABU DHABI OCEAN
L
M OCEAN
N
P
R
S BLUE WORLD
T
U
V
W
SEA OF
X
DELIGHT TROPICAL
Y
Z ENDLESS OCEAN
AA
AB
OCEAN
AC
AD
AE
AF
AG
AH

GENERAL NOTES :

1 . DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES


UNLESS NOTED OTHERWISE.

BIM MODEL REFERENCE:


1. TP9-USW-051000-BB0A-MB-ST
2. TP9-USW-051000-AD0A-MB-ST-VOL1
3. TP9-USW-051000-AD0A-MB-ST-VOL2
4. TP9-USW-051000-BW0A-MB-ST-VOL2
5. TP9-USW-051000-EO0A-MB-ST-VOL1
6. TP9-USW-051000-EO0A-MB-ST-VOL2
7. TP9-USW-051000-TO0A-MB-ST-VOL1
8. TP9-USW-051000-TO0A-MB-ST-VOL2

LEGEND:

ENGINEER DOCUMENT REVIEW

AECOM - APPROVAL STAMP

ü
CODE A CODE B CODE C

Approved Approved As Noted Revise and Resubmit

Cheryl Soares
Reviewed by:...................................................................................................................................................

10/05/2023
RE Sig:.......................................................................................Date:............................................................

REVIEWED FOR COORDINATION :

ESCALATOR KEY PLAN | LEVEL-1 ESCALATOR KEY PLAN | LEVEL-2 Structure:_____________________ MEP:_____________________

Architectural:__________________ ALSS:____________________

Facade:______________________ VT:______________________

CONTRACTOR CERTIFICATION :

THE CONTRACTOR CERTIFIES THAT IT HAS PREPARED AND REVIEWED THIS SHOP DRAWING (OR AS-BUILT) IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS (AND ALL VARIATIONS THERETO). SPECIFICALLY, THE
CONTRACTOR ATTESTS THAT IT HAS COORDINATED WITH ALL RELATED WORKS AND TRADES, PRODUCT DATA,
SAMPLES, OTHER SUBMITTALS AND HAS VERIFIED ALL DIMENSIONS, QUANTITIES, FIELD DIMENSIONS TO EXISTING
WORKS AND/OR WORKS TO BE INSTALLED AND OTHER ATTRIBUTES INCLUDING TOLLERANCE, CLEARANCE,
FABRICATION PROCESS AND TECHNIQUES OF CONSTRUCTION IN FULL COMPLIANCE WITH THE CONTRACT
DOCUMENTS.

...................................................
NAME

................................................... ...................................................
DATE AUTHORIZED SIGNATURE

EMPLOYER: LICENSOR:

PROJECT MANAGER: CONSULTANT:

MAIN CONTRACTOR: SUB CONTRACTOR:

UNITED STEEL WORKS LLC


KHIA-5, 39a
KIZAD
PO Box No. 93026, ABU DHABI, UAE
Tel.+971 25868930
ALEC Engineering and Conreacting L.L.C.
P.O. Box 27639 Dubai U.A.E.
Tel: 04-429 0599 Fax: 04-429 0216

PROJECT NAME:

SEAWORLD ABU DHABI

THIS DOCUMENT CONTAINS INTELLECTUAL PROPERTY MATERIAL, CONFIDENTIAL


INFORMATION AND/OR PROPRIETARY INFORMATION OF SEAWORLD PARKS &
ENTERTAINMENT INTERNATIONAL, INC. AND MIRAL ASSET MANAGEMENT LLC
SECTOR NO. YS 6 PLOT NO. C1

A1 ISSUED FOR APPROVAL 24/03/2023 MSK NS


A0 ISSUED FOR APPROVAL 10/02/2023 MSK NS
REV. DESCRIPTION DATE DRAWN CHKD
DRAWING TITILE:

ESCALATOR BOLLARDS
KEY PLANS
ESCALATOR KEY PLAN | LEVEL-3 ESCALATOR KEY PLAN | LEVEL-4 ASSET NO./ATTRACTIONS:

AD0A
SHOP DRAWING REF:- ABBREVATIONS & SYMBOLS LEGEND NOTES RFI REF:- IFC DRAWING REF:- DISCIPLINE:

SSL - Structural Slab Level 1. THE FINAL DIMENSIONS


STRUCTURES
FFL - Finished Floor Level ARE IN ACCORDANCE
WITH THE SITE DRAWING NUMBER: REVISION
TOC - Top of Concrete 6 MATERIAL SUBMITTAL FOR ESCALATOR BOLLARDS TP9-USW-051000-MS-000006 A0 TP9-USW-051000-MS-000006
CONDITION.
5 ESCALATOR TYPICAL DETAILS TP9-ACM-010000-BB0A-SK-AR-000788 C1 ACM-TRANSMIT-060493 TP9-USW-051000-AD0A -DG-ST- 310002 A1
4 LEVEL 04 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540304 C0
3 LEVEL 03 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540303 C0
DATE SHEET SCALE DRAWN BY CHECKED BY APPROVED BY
2 LEVEL 02 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540302 C0
1 DESIGN CALCULATIONS FOR ELEVATOR BOLLARDS TP9-USW-051000-DE-000006 A0 1 LEVEL 01 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540301 C0 10/02/2023 A0 As indicated MSK NS NS
SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL
KEY PLAN N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

A
B
QIBLA
C
D
E
F
G
H POLOR
J
K ABU DHABI OCEAN
L
M OCEAN
N
P
R
S BLUE WORLD
T
U
V
W
SEA OF
X
DELIGHT TROPICAL
Y
Z ENDLESS OCEAN
AA
AB
OCEAN
AC
AD
AE
AF
AG
AH

GENERAL NOTES :

1 . DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES


UNLESS NOTED OTHERWISE.

BIM MODEL REFERENCE:


1. TP9-USW-051000-BB0A-MB-ST
2. TP9-USW-051000-AD0A-MB-ST-VOL1
3. TP9-USW-051000-AD0A-MB-ST-VOL2
4. TP9-USW-051000-BW0A-MB-ST-VOL2
5. TP9-USW-051000-EO0A-MB-ST-VOL1
6. TP9-USW-051000-EO0A-MB-ST-VOL2
7. TP9-USW-051000-TO0A-MB-ST-VOL1
8. TP9-USW-051000-TO0A-MB-ST-VOL2

LEGEND:

ENGINEER DOCUMENT REVIEW

AECOM - APPROVAL STAMP

ü
CODE A CODE B CODE C

Approved Approved As Noted Revise and Resubmit

Cheryl Soares
Reviewed by:...................................................................................................................................................

10/05/2023
RE Sig:.......................................................................................Date:............................................................

REVIEWED FOR COORDINATION :

ESCALATOR KEY PLAN | LEVEL-1 ESCALATOR KEY PLAN | LEVEL-2 Structure:_____________________ MEP:_____________________

Architectural:__________________ ALSS:____________________

Facade:______________________ VT:______________________

CONTRACTOR CERTIFICATION :

THE CONTRACTOR CERTIFIES THAT IT HAS PREPARED AND REVIEWED THIS SHOP DRAWING (OR AS-BUILT) IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS (AND ALL VARIATIONS THERETO). SPECIFICALLY, THE
CONTRACTOR ATTESTS THAT IT HAS COORDINATED WITH ALL RELATED WORKS AND TRADES, PRODUCT DATA,
SAMPLES, OTHER SUBMITTALS AND HAS VERIFIED ALL DIMENSIONS, QUANTITIES, FIELD DIMENSIONS TO EXISTING
WORKS AND/OR WORKS TO BE INSTALLED AND OTHER ATTRIBUTES INCLUDING TOLLERANCE, CLEARANCE,
FABRICATION PROCESS AND TECHNIQUES OF CONSTRUCTION IN FULL COMPLIANCE WITH THE CONTRACT
DOCUMENTS.

...................................................
NAME

................................................... ...................................................
DATE AUTHORIZED SIGNATURE

EMPLOYER: LICENSOR:

PROJECT MANAGER: CONSULTANT:

MAIN CONTRACTOR: SUB CONTRACTOR:

UNITED STEEL WORKS LLC


KHIA-5, 39a
KIZAD
PO Box No. 93026, ABU DHABI, UAE
Tel.+971 25868930
ALEC Engineering and Conreacting L.L.C.
P.O. Box 27639 Dubai U.A.E.
Tel: 04-429 0599 Fax: 04-429 0216

PROJECT NAME:

SEAWORLD ABU DHABI

THIS DOCUMENT CONTAINS INTELLECTUAL PROPERTY MATERIAL, CONFIDENTIAL


INFORMATION AND/OR PROPRIETARY INFORMATION OF SEAWORLD PARKS &
ENTERTAINMENT INTERNATIONAL, INC. AND MIRAL ASSET MANAGEMENT LLC
SECTOR NO. YS 6 PLOT NO. C1

A1 ISSUED FOR APPROVAL 24/03/2023 MSK NS


A0 ISSUED FOR APPROVAL 10/02/2023 MSK NS
REV. DESCRIPTION DATE DRAWN CHKD
DRAWING TITILE:

ESCALATOR BOLLARDS
KEY PLANS
ESCALATOR KEY PLAN | LEVEL-3 ESCALATOR KEY PLAN | LEVEL-4 ASSET NO./ATTRACTIONS:

AD0A
SHOP DRAWING REF:- ABBREVATIONS & SYMBOLS LEGEND NOTES RFI REF:- IFC DRAWING REF:- DISCIPLINE:

SSL - Structural Slab Level 1. THE FINAL DIMENSIONS


STRUCTURES
FFL - Finished Floor Level ARE IN ACCORDANCE
WITH THE SITE DRAWING NUMBER: REVISION
TOC - Top of Concrete 6 MATERIAL SUBMITTAL FOR ESCALATOR BOLLARDS TP9-USW-051000-MS-000006 A0 TP9-USW-051000-MS-000006
CONDITION.
5 ESCALATOR TYPICAL DETAILS TP9-ACM-010000-BB0A-SK-AR-000788 C1 ACM-TRANSMIT-060493 TP9-USW-051000-AD0A -DG-ST- 310002 A1
4 LEVEL 04 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540304 C0
3 LEVEL 03 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540303 C0
DATE SHEET SCALE DRAWN BY CHECKED BY APPROVED BY
2 LEVEL 02 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540302 C0
1 DESIGN CALCULATIONS FOR ELEVATOR BOLLARDS TP9-USW-051000-DE-000006 A0 1 LEVEL 01 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540301 C0 10/02/2023 A0 As indicated MSK NS NS
SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL
KEY PLAN N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

A
B
QIBLA
C
D
E
F
G
H POLOR
J
K ABU DHABI OCEAN
L
M OCEAN
N
P
R
S BLUE WORLD
T
U
V
W
SEA OF
X
DELIGHT TROPICAL
Y
Z ENDLESS OCEAN
AA
AB
OCEAN
AC
AD
AE
AF
AG
AH

GENERAL NOTES :

1 . DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES


UNLESS NOTED OTHERWISE.

BIM MODEL REFERENCE:


1. TP9-USW-051000-BB0A-MB-ST
2. TP9-USW-051000-AD0A-MB-ST-VOL1
3. TP9-USW-051000-AD0A-MB-ST-VOL2
4. TP9-USW-051000-BW0A-MB-ST-VOL2
5. TP9-USW-051000-EO0A-MB-ST-VOL1
6. TP9-USW-051000-EO0A-MB-ST-VOL2
7. TP9-USW-051000-TO0A-MB-ST-VOL1
8. TP9-USW-051000-TO0A-MB-ST-VOL2

LEGEND:

ENGINEER DOCUMENT REVIEW

AECOM - APPROVAL STAMP

ü
CODE A CODE B CODE C

Approved Approved As Noted Revise and Resubmit

Cheryl Soares
Reviewed by:...................................................................................................................................................

10/05/2023
RE Sig:.......................................................................................Date:............................................................

REVIEWED FOR COORDINATION :

ESCALATOR KEY PLAN | LEVEL-1 ESCALATOR KEY PLAN | LEVEL-2 Structure:_____________________ MEP:_____________________

Architectural:__________________ ALSS:____________________

Facade:______________________ VT:______________________

CONTRACTOR CERTIFICATION :

THE CONTRACTOR CERTIFIES THAT IT HAS PREPARED AND REVIEWED THIS SHOP DRAWING (OR AS-BUILT) IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS (AND ALL VARIATIONS THERETO). SPECIFICALLY, THE
CONTRACTOR ATTESTS THAT IT HAS COORDINATED WITH ALL RELATED WORKS AND TRADES, PRODUCT DATA,
SAMPLES, OTHER SUBMITTALS AND HAS VERIFIED ALL DIMENSIONS, QUANTITIES, FIELD DIMENSIONS TO EXISTING
WORKS AND/OR WORKS TO BE INSTALLED AND OTHER ATTRIBUTES INCLUDING TOLLERANCE, CLEARANCE,
FABRICATION PROCESS AND TECHNIQUES OF CONSTRUCTION IN FULL COMPLIANCE WITH THE CONTRACT
DOCUMENTS.

...................................................
NAME

................................................... ...................................................
DATE AUTHORIZED SIGNATURE

EMPLOYER: LICENSOR:

PROJECT MANAGER: CONSULTANT:

MAIN CONTRACTOR: SUB CONTRACTOR:

UNITED STEEL WORKS LLC


KHIA-5, 39a
KIZAD
PO Box No. 93026, ABU DHABI, UAE
Tel.+971 25868930
ALEC Engineering and Conreacting L.L.C.
P.O. Box 27639 Dubai U.A.E.
Tel: 04-429 0599 Fax: 04-429 0216

PROJECT NAME:

SEAWORLD ABU DHABI

THIS DOCUMENT CONTAINS INTELLECTUAL PROPERTY MATERIAL, CONFIDENTIAL


INFORMATION AND/OR PROPRIETARY INFORMATION OF SEAWORLD PARKS &
ENTERTAINMENT INTERNATIONAL, INC. AND MIRAL ASSET MANAGEMENT LLC
SECTOR NO. YS 6 PLOT NO. C1

A1 ISSUED FOR APPROVAL 24/03/2023 MSK NS


A0 ISSUED FOR APPROVAL 10/02/2023 MSK NS
REV. DESCRIPTION DATE DRAWN CHKD
DRAWING TITILE:

ESCALATOR BOLLARDS
KEY PLANS
ESCALATOR KEY PLAN | LEVEL-3 ESCALATOR KEY PLAN | LEVEL-4 ASSET NO./ATTRACTIONS:

AD0A
SHOP DRAWING REF:- ABBREVATIONS & SYMBOLS LEGEND NOTES RFI REF:- IFC DRAWING REF:- DISCIPLINE:

SSL - Structural Slab Level 1. THE FINAL DIMENSIONS


STRUCTURES
FFL - Finished Floor Level ARE IN ACCORDANCE
WITH THE SITE DRAWING NUMBER: REVISION
TOC - Top of Concrete 6 MATERIAL SUBMITTAL FOR ESCALATOR BOLLARDS TP9-USW-051000-MS-000006 A0 TP9-USW-051000-MS-000006
CONDITION.
5 ESCALATOR TYPICAL DETAILS TP9-ACM-010000-BB0A-SK-AR-000788 C1 ACM-TRANSMIT-060493 TP9-USW-051000-AD0A -DG-ST- 310002 A1
4 LEVEL 04 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540304 C0
3 LEVEL 03 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540303 C0
DATE SHEET SCALE DRAWN BY CHECKED BY APPROVED BY
2 LEVEL 02 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540302 C0
1 DESIGN CALCULATIONS FOR ELEVATOR BOLLARDS TP9-USW-051000-DE-000006 A0 1 LEVEL 01 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540301 C0 10/02/2023 A0 As indicated MSK NS NS
SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL
KEY PLAN N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

11 12 13 A

10 11 12 B
C
D
QIBLA

E
F
G
H POLOR
J
K ABU DHABI OCEAN
L
M OCEAN
N
P
R
S BLUE WORLD
T
U

ES-01 & ES-02


V
W
SEA OF
X
DELIGHT TROPICAL
Y
Z ENDLESS OCEAN
AA
AB
OCEAN
AC
AD
AE
AF

A A B
AG
AH

GENERAL NOTES :

1 . DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES


UNLESS NOTED OTHERWISE.

BIM MODEL REFERENCE:


ES-01 & ES-02 1. TP9-USW-051000-BB0A-MB-ST
2. TP9-USW-051000-AD0A-MB-ST-VOL1
3. TP9-USW-051000-AD0A-MB-ST-VOL2
4. TP9-USW-051000-BW0A-MB-ST-VOL2
5. TP9-USW-051000-EO0A-MB-ST-VOL1
6. TP9-USW-051000-EO0A-MB-ST-VOL2
C 7. TP9-USW-051000-TO0A-MB-ST-VOL1
8. TP9-USW-051000-TO0A-MB-ST-VOL2

B B LEGEND:

ES-03 & ES-04

ENGINEER DOCUMENT REVIEW

AECOM - APPROVAL STAMP


D
CODE A CODE B CODE C

Approved Approved As Noted Revise and Resubmit

Reviewed by:...................................................................................................................................................

RE Sig:.......................................................................................Date:............................................................
10 11 12
REVIEWED FOR COORDINATION :

LEVEL-1 : ADO : ESCALATOR BOLLARDS SETTING OUT PLAN LEVEL-2 : ADO : ESCALATOR BOLLARDS SETTING OUT PLAN Structure:_____________________ MEP:_____________________

ES-01 / ES-02 ES-01 / ES-02 & ES-03 / ES-04


Architectural:__________________ ALSS:____________________

Facade:______________________ VT:______________________

11 12 CONTRACTOR CERTIFICATION :

THE CONTRACTOR CERTIFIES THAT IT HAS PREPARED AND REVIEWED THIS SHOP DRAWING (OR AS-BUILT) IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS (AND ALL VARIATIONS THERETO). SPECIFICALLY, THE
CONTRACTOR ATTESTS THAT IT HAS COORDINATED WITH ALL RELATED WORKS AND TRADES, PRODUCT DATA,
SAMPLES, OTHER SUBMITTALS AND HAS VERIFIED ALL DIMENSIONS, QUANTITIES, FIELD DIMENSIONS TO EXISTING
WORKS AND/OR WORKS TO BE INSTALLED AND OTHER ATTRIBUTES INCLUDING TOLLERANCE, CLEARANCE,
FABRICATION PROCESS AND TECHNIQUES OF CONSTRUCTION IN FULL COMPLIANCE WITH THE CONTRACT
DOCUMENTS.

...................................................
NAME

................................................... ...................................................
DATE AUTHORIZED SIGNATURE

EMPLOYER: LICENSOR:
ES-03 & ES-04

D
PROJECT MANAGER: CONSULTANT:

MAIN CONTRACTOR: SUB CONTRACTOR:

UNITED STEEL WORKS LLC


KHIA-5, 39a
KIZAD
PO Box No. 93026, ABU DHABI, UAE
Tel.+971 25868930
ALEC Engineering and Conreacting L.L.C.
P.O. Box 27639 Dubai U.A.E.
Tel: 04-429 0599 Fax: 04-429 0216
E
PROJECT NAME:

SEAWORLD ABU DHABI

THIS DOCUMENT CONTAINS INTELLECTUAL PROPERTY MATERIAL, CONFIDENTIAL


INFORMATION AND/OR PROPRIETARY INFORMATION OF SEAWORLD PARKS &
ENTERTAINMENT INTERNATIONAL, INC. AND MIRAL ASSET MANAGEMENT LLC
SECTOR NO. YS 6 PLOT NO. C1

A0 ISSUED FOR APPROVAL 22/03/2023 MSK NS


REV. DESCRIPTION DATE DRAWN CHKD
DRAWING TITILE:

ESCALATOR BOLLARDS
LEVEL-3 : ADO : ESCALATOR BOLLARDS SETTING OUT PLAN KEY PLANS

ES-03 / ES-04 ASSET NO./ATTRACTIONS:

AD0A
SHOP DRAWING REF:- ABBREVATIONS & SYMBOLS LEGEND NOTES RFI REF:- IFC DRAWING REF:- DISCIPLINE:

SSL - Structural Slab Level 1. THE FINAL DIMENSIONS


STRUCTURES
FFL - Finished Floor Level ARE IN ACCORDANCE
WITH THE SITE DRAWING NUMBER: REVISION
TOC - Top of Concrete 6 MATERIAL SUBMITTAL FOR ESCALATOR BOLLARDS TP9-USW-051000-MS-000006 A0 TP9-USW-051000-MS-000006
CONDITION.
5 ESCALATOR TYPICAL DETAILS TP9-ACM-010000-BB0A-SK-AR-000788 C1 ACM-TRANSMIT-060493 TP9-USW-051000-AD0A -DG-ST- 310005 A0
4 LEVEL 04 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540304 C0
3 LEVEL 03 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540303 C0
DATE SHEET SCALE DRAWN BY CHECKED BY APPROVED BY
2 LEVEL 02 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540302 C0
1 DESIGN CALCULATIONS FOR ELEVATOR BOLLARDS TP9-USW-051000-DE-000006 A0 1 LEVEL 01 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540301 C0 10/02/2023 A0 As indicated MSK NS NS
SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL
KEY PLAN N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

A
B
QIBLA
C
D
E
F
G
H POLOR
J
K ABU DHABI OCEAN
L
M OCEAN
N
P
R
S BLUE WORLD
T
U
V
W
SEA OF
X
DELIGHT TROPICAL
Y
Z ENDLESS OCEAN
AA
AB
OCEAN
AC
AD
AE
AF
AG
AH

GENERAL NOTES :

1 . DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES


UNLESS NOTED OTHERWISE.

BIM MODEL REFERENCE:


21 1. TP9-USW-051000-BB0A-MB-ST
2. TP9-USW-051000-AD0A-MB-ST-VOL1
3. TP9-USW-051000-AD0A-MB-ST-VOL2
22 4.
5.
TP9-USW-051000-BW0A-MB-ST-VOL2
TP9-USW-051000-EO0A-MB-ST-VOL1
6. TP9-USW-051000-EO0A-MB-ST-VOL2
7. TP9-USW-051000-TO0A-MB-ST-VOL1
8. TP9-USW-051000-TO0A-MB-ST-VOL2

LEGEND:

3362
Contractor to resubmit as per
R commentsR
ENGINEER DOCUMENT REVIEW

AECOM - APPROVAL STAMP

provide clear
ü
CODE A CODE B CODE C

dimensions Approved Approved As Noted Revise and Resubmit

2452
Cheryl Soares
620 Reviewed by:...................................................................................................................................................

3014
200
620

CL
200 R
ES-12 15/05/2023
RE Sig:.......................................................................................Date:............................................................

EA
REVIEWED FOR COORDINATION :
provide clear

674
provide clear Structure:_____________________ MEP:_____________________

dimensions Pto CL
17
P dimensions to
112

8
EA Architectural:__________________ ALSS:____________________

52
handrail handrail 0

0
62
R
Facade:______________________ VT:______________________
0
2257 62
55 CONTRACTOR CERTIFICATION :

THE CONTRACTOR CERTIFIES THAT IT HAS PREPARED AND REVIEWED THIS SHOP DRAWING (OR AS-BUILT) IN

ES-12 1050
ACCORDANCE WITH THE CONTRACT DOCUMENTS (AND ALL VARIATIONS THERETO). SPECIFICALLY, THE
CONTRACTOR ATTESTS THAT IT HAS COORDINATED WITH ALL RELATED WORKS AND TRADES, PRODUCT DATA,
SAMPLES, OTHER SUBMITTALS AND HAS VERIFIED ALL DIMENSIONS, QUANTITIES, FIELD DIMENSIONS TO EXISTING

provide clear WORKS AND/OR WORKS TO BE INSTALLED AND OTHER ATTRIBUTES INCLUDING TOLLERANCE, CLEARANCE,
FABRICATION PROCESS AND TECHNIQUES OF CONSTRUCTION IN FULL COMPLIANCE WITH THE CONTRACT
DOCUMENTS.

dimensions ...................................................
NAME

................................................... ...................................................
DATE AUTHORIZED SIGNATURE

EMPLOYER: LICENSOR:

22
21
PROJECT MANAGER: CONSULTANT:

MAIN CONTRACTOR: SUB CONTRACTOR:

UNITED STEEL WORKS LLC


KHIA-5, 39a
KIZAD
PO Box No. 93026, ABU DHABI, UAE
Tel.+971 25868930
ALEC Engineering and Conreacting L.L.C.
P.O. Box 27639 Dubai U.A.E.
Tel: 04-429 0599 Fax: 04-429 0216

PROJECT NAME:

LEVEL-3 : SETTING OUT LAYOUT LEVEL-4 : SETTING OUT LAYOUT SEAWORLD ABU DHABI
BWO | ( SCALE = 1:50 ) BWO | ( SCALE = 1:50 )
THIS DOCUMENT CONTAINS INTELLECTUAL PROPERTY MATERIAL, CONFIDENTIAL
INFORMATION AND/OR PROPRIETARY INFORMATION OF SEAWORLD PARKS &
ENTERTAINMENT INTERNATIONAL, INC. AND MIRAL ASSET MANAGEMENT LLC
SECTOR NO. YS 6 PLOT NO. C1

A0 ISSUED FOR APPROVAL 29/03/2023 MSK NS


REV. DESCRIPTION DATE DRAWN CHKD
DRAWING TITILE:

ESCALATOR BOLLARDS
KEY PLANS

ASSET NO./ATTRACTIONS:

OO0A
SHOP DRAWING REF:- ABBREVATIONS & SYMBOLS LEGEND NOTES RFI REF:- IFC DRAWING REF:- DISCIPLINE:

SSL - Structural Slab Level 1. THE FINAL DIMENSIONS


STRUCTURES
FFL - Finished Floor Level ARE IN ACCORDANCE
WITH THE SITE DRAWING NUMBER: REVISION
TOC - Top of Concrete 6 MATERIAL SUBMITTAL FOR ESCALATOR BOLLARDS TP9-USW-051000-MS-000006 A0 TP9-USW-051000-MS-000006
CONDITION.
5 ESCALATOR TYPICAL DETAILS TP9-ACM-010000-BB0A-SK-AR-000788 C1 ACM-TRANSMIT-060493 TP9-USW-051000-OO0A-DG-ST- 310001 A0
4 LEVEL 04 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540304 C0
3 ESCALATOR BOLLARDS - TYPICAL DETAILS TP9-USW-051000-AD0A-DG-ST-310003 A0 3 LEVEL 03 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540303 C0
DATE SHEET SCALE DRAWN BY CHECKED BY APPROVED BY
2 ESCALATOR BOLLARDS - KEY PLANS TP9-USW-051000-AD0A-DG-ST-310002 A0 2 LEVEL 02 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540302 C0
1 DESIGN CALCULATIONS FOR ELEVATOR BOLLARDS TP9-USW-051000-DE-000006 A0 1 LEVEL 01 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540301 C0 10/02/2023 A0 As indicated MSK NS NS
SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL
KEY PLAN N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41

A
B
QIBLA
C
D
E
F
G
H POLOR
J
K ABU DHABI OCEAN
L
M OCEAN
N
P
R
S BLUE WORLD
T
U
V
W
SEA OF
X
DELIGHT TROPICAL
Y
Z ENDLESS OCEAN
AA
AB
OCEAN
AC
AD
AE
AF
AG

33 34 AH

GENERAL NOTES :

1 . DO NOT SCALE FROM THE DRAWINGS.

2. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES


UNLESS NOTED OTHERWISE.

N N BIM MODEL REFERENCE:

1. TP9-USW-051000-BB0A-MB-ST
2. TP9-USW-051000-AD0A-MB-ST-VOL1
3. TP9-USW-051000-AD0A-MB-ST-VOL2
4. TP9-USW-051000-BW0A-MB-ST-VOL2
5. TP9-USW-051000-EO0A-MB-ST-VOL1
6. TP9-USW-051000-EO0A-MB-ST-VOL2
7. TP9-USW-051000-TO0A-MB-ST-VOL1
8. TP9-USW-051000-TO0A-MB-ST-VOL2

3053
32
2403 LEGEND:

62
0
0 ENGINEER DOCUMENT REVIEW

62
18 R
EA

0
AECOM - APPROVAL STAMP

CL CODE A CODE B CODE C

P P Approved Approved As Noted Revise and Resubmit

0
20
Reviewed by:...................................................................................................................................................

6869 RE Sig:.......................................................................................Date:............................................................

2254
ES-11
222 REVIEWED FOR COORDINATION :

3219
Structure:_____________________ MEP:_____________________

Architectural:__________________ ALSS:____________________

ES-11
Facade:______________________ VT:______________________

CONTRACTOR CERTIFICATION :
5943

62
0
20 R
THE CONTRACTOR CERTIFIES THAT IT HAS PREPARED AND REVIEWED THIS SHOP DRAWING (OR AS-BUILT) IN

0
ACCORDANCE WITH THE CONTRACT DOCUMENTS (AND ALL VARIATIONS THERETO). SPECIFICALLY, THE
CONTRACTOR ATTESTS THAT IT HAS COORDINATED WITH ALL RELATED WORKS AND TRADES, PRODUCT DATA,

6 EA SAMPLES, OTHER SUBMITTALS AND HAS VERIFIED ALL DIMENSIONS, QUANTITIES, FIELD DIMENSIONS TO EXISTING

54 CL

62
WORKS AND/OR WORKS TO BE INSTALLED AND OTHER ATTRIBUTES INCLUDING TOLLERANCE, CLEARANCE,
FABRICATION PROCESS AND TECHNIQUES OF CONSTRUCTION IN FULL COMPLIANCE WITH THE CONTRACT
DOCUMENTS.

0
...................................................
NAME

................................................... ...................................................
506 DATE AUTHORIZED SIGNATURE

EMPLOYER: LICENSOR:

PROJECT MANAGER: CONSULTANT:


32
P P

MAIN CONTRACTOR: SUB CONTRACTOR:

UNITED STEEL WORKS LLC


KHIA-5, 39a
KIZAD
PO Box No. 93026, ABU DHABI, UAE
Tel.+971 25868930

33 34 ALEC Engineering and Conreacting L.L.C.


P.O. Box 27639 Dubai U.A.E.
Tel: 04-429 0599 Fax: 04-429 0216

PROJECT NAME:

LEVEL-2 : SETTING OUT LAYOUT LEVEL-3 : SETTING OUT LAYOUT SEAWORLD ABU DHABI
TO | ( SCALE = 1:50 ) TO | ( SCALE = 1:50 )
THIS DOCUMENT CONTAINS INTELLECTUAL PROPERTY MATERIAL, CONFIDENTIAL
INFORMATION AND/OR PROPRIETARY INFORMATION OF SEAWORLD PARKS &
ENTERTAINMENT INTERNATIONAL, INC. AND MIRAL ASSET MANAGEMENT LLC
SECTOR NO. YS 6 PLOT NO. C1

A0 ISSUED FOR APPROVAL 28/03/2023 MSK NS


REV. DESCRIPTION DATE DRAWN CHKD
DRAWING TITILE:

ESCALATOR BOLLARDS
KEY PLANS

ASSET NO./ATTRACTIONS:

TO0A
SHOP DRAWING REF:- ABBREVATIONS & SYMBOLS LEGEND NOTES RFI REF:- IFC DRAWING REF:- DISCIPLINE:

SSL - Structural Slab Level 1. THE FINAL DIMENSIONS


STRUCTURES
FFL - Finished Floor Level ARE IN ACCORDANCE
WITH THE SITE DRAWING NUMBER: REVISION
TOC - Top of Concrete 6 MATERIAL SUBMITTAL FOR ESCALATOR BOLLARDS TP9-USW-051000-MS-000006 A0 TP9-USW-051000-MS-000006
CONDITION.
5 ESCALATOR TYPICAL DETAILS TP9-ACM-010000-BB0A-SK-AR-000788 C1 ACM-TRANSMIT-060493 TP9-USW-051000-TO0A -DG-ST- 310006 A0
4 LEVEL 04 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540304 C0
3 ESCALATOR BOLLARDS - TYPICAL DETAILS TP9-USW-051000-AD0A-DG-ST-310003 A0 3 LEVEL 03 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540303 C0
DATE SHEET SCALE DRAWN BY CHECKED BY APPROVED BY
2 ESCALATOR BOLLARDS - KEY PLANS TP9-USW-051000-AD0A-DG-ST-310002 A0 2 LEVEL 02 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540302 C0
1 DESIGN CALCULATIONS FOR ELEVATOR BOLLARDS TP9-USW-051000-DE-000006 A0 1 LEVEL 01 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540301 C0 10/02/2023 A0 As indicated MSK NS NS
SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL
KEY PLAN
141 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
N

OD OF BOLLARD B
C
QIBLA

CHS141.3 x SCH40 D

80
E
F

BOLLARD G
H POLOR
TYP
J
ABU DHABI OCEAN
FIS A M10 * 1000R
K
L
M OCEAN
Ø127 DIA PIPE THREADED ROD N
P
R
BLUE WORLD
SLEEVE S
T
U
V
W
SEA OF
X
DELIGHT TROPICAL
Y
Z ENDLESS OCEAN
AA
AB
OCEAN
AC

A1 A1 AD
AE
AF

TYP (4) * M8 CSK


AG
AH

SCREW AT 4 SIDES
127 GENERAL NOTES :
OD OF SLEEVE
All materials need to 1 . DO NOT SCALE FROM THE DRAWINGS.

DETAIL : A match corrosion


2. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES
UNLESS NOTED OTHERWISE.
( SCALE = 1:5 )

CHS141.3 x SCH40 requirements BIM MODEL REFERENCE:


1.
2.
TP9-USW-051000-BB0A-MB-ST
TP9-USW-051000-AD0A-MB-ST-VOL1
BOLLARD 3. TP9-USW-051000-AD0A-MB-ST-VOL2
4. TP9-USW-051000-BW0A-MB-ST-VOL2
5. TP9-USW-051000-EO0A-MB-ST-VOL1
Ø127 DIA PIPE (4) * M8 CSK 6. TP9-USW-051000-EO0A-MB-ST-VOL2
SLEEVE SCREW AT 4 SIDES 7. TP9-USW-051000-TO0A-MB-ST-VOL1
8. TP9-USW-051000-TO0A-MB-ST-VOL2

FIS A M10 * 1000R

75
THREADED ROD

150
12mm THICK

75
BASE PLATE LEGEND:

12

EMBEDMENT
100
STRUCTURAL ENGINEER DOCUMENT REVIEW
SLAB LEVEL

191
AECOM - APPROVAL STAMP

ü
CODE A CODE B CODE C

91
Approved Approved As Noted Revise and Resubmit

Cheryl Soares Karim Roshdy


Reviewed by:...................................................................................................................................................

10/05/2023
RE Sig:.......................................................................................Date:............................................................

ESCALATOR SECTION DETAIL (3 FLAT STEPS) 1 REVIEWED FOR COORDINATION :

( SCALE = 1:50 ) SECTION : A1 - A1 Structure:_____________________ MEP:_____________________


( SCALE = 1:5 )
Architectural:__________________ ALSS:____________________

Facade:______________________ VT:______________________
200 (MIN.)
Ø30 STEEL BAR VARIES CONTRACTOR CERTIFICATION :

THE CONTRACTOR CERTIFIES THAT IT HAS PREPARED AND REVIEWED THIS SHOP DRAWING (OR AS-BUILT) IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS (AND ALL VARIATIONS THERETO). SPECIFICALLY, THE
C
L CONTRACTOR ATTESTS THAT IT HAS COORDINATED WITH ALL RELATED WORKS AND TRADES, PRODUCT DATA,
695

150
SAMPLES, OTHER SUBMITTALS AND HAS VERIFIED ALL DIMENSIONS, QUANTITIES, FIELD DIMENSIONS TO EXISTING
WORKS AND/OR WORKS TO BE INSTALLED AND OTHER ATTRIBUTES INCLUDING TOLLERANCE, CLEARANCE,
FABRICATION PROCESS AND TECHNIQUES OF CONSTRUCTION IN FULL COMPLIANCE WITH THE CONTRACT
DOCUMENTS.
125 570
...................................................

Provide clear NAME

43
................................................... ...................................................
DATE AUTHORIZED SIGNATURE

dimensions CHS141.3 x SCH40 EMPLOYER: LICENSOR:

BOLLARD
ESCALATOR LANDING
POINT

620

430
CHS141.3 x SCH40
BOLLARD
PROJECT MANAGER:
Ø30mm STAINLESS CONSULTANT:

STEEL BAR

888
ESCALATOR 1
MAIN CONTRACTOR: SUB CONTRACTOR:
DET : A

415
TYP 200 UNITED STEEL WORKS LLC
KHIA-5, 39a

ESCALATOR LANDING KIZAD

POINT & ACCESS COVER FOH FLOOR PO Box No. 93026, ABU DHABI, UAE
Tel.+971 25868930

FINISH ALEC Engineering and Conreacting L.L.C.

45
Ensure all are 620 STRUCTURAL
P.O. Box 27639 Dubai U.A.E.
Tel: 04-429 0599 Fax: 04-429 0216
ESCALATOR LANDING

SCREED
POINT SLAB
aligned with PROJECT NAME:

100
escalators SEAWORLD ABU DHABI

THIS DOCUMENT CONTAINS INTELLECTUAL PROPERTY MATERIAL, CONFIDENTIAL


INFORMATION AND/OR PROPRIETARY INFORMATION OF SEAWORLD PARKS &
ENTERTAINMENT INTERNATIONAL, INC. AND MIRAL ASSET MANAGEMENT LLC
150

SECTOR NO. YS 6 PLOT NO. C1

A1 ISSUED FOR APPROVAL 24/03/2023 MSK NS


A0 ISSUED FOR APPROVAL 10/02/2023 MSK NS
REV. DESCRIPTION DATE DRAWN CHKD
DRAWING TITILE:

TYPICAL DETAILS FOR


ESCALATOR BOLLARDS
3D VIEW - ESCALATOR BOLLARDS BOLLARD PLAN DETAIL BOLLARD ELEVATION DETAIL ASSET NO./ATTRACTIONS:
( SCALE = 1:10 ) ( SCALE = 1:10 ) ( SCALE = 1:10 ) AD0A
SHOP DRAWING REF:- ABBREVATIONS & SYMBOLS LEGEND NOTES RFI REF:- IFC DRAWING REF:- DISCIPLINE:

SSL - Structural Slab Level 1. THE FINAL DIMENSIONS


STRUCTURES
FFL - Finished Floor Level ARE IN ACCORDANCE
WITH THE SITE DRAWING NUMBER: REVISION
TOC - Top of Concrete 6 MATERIAL SUBMITTAL FOR ESCALATOR BOLLARDS TP9-USW-051000-MS-000006 A0 TP9-USW-051000-MS-000006

OD - Outside Diameter CONDITION.


ID - Inside Diameter
5 ESCALATOR TYPICAL DETAILS TP9-ACM-010000-BB0A-SK-AR-000788 C1 ACM-TRANSMIT-060493
TP9-USW-051000-AD0A -DG-ST- 310003 A1
4 LEVEL 04 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540304 C0
3 LEVEL 03 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540303 C0
DATE SHEET SCALE DRAWN BY CHECKED BY APPROVED BY
2 ESCALATOR BOLLARDS - SETTING OUT LAYOUT TP9-USW-051000-AD0A-DG-ST-310005 A0 2 LEVEL 02 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540302 C0
1 DESIGN CALCULATIONS FOR ELEVATOR BOLLARDS TP9-USW-051000-DE-000006 A0 1 LEVEL 01 ESCALATOR KEYPLAN TP9-ACM-010000-BB0A-DG-AR-540301 C0 10/02/2023 A0 As indicated MSK NS NS
SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL SI No DRAWING TITLE DRAWING NO REV TRANSMITTAL
MATERIAL SUBMITTAL

Aconex Ref. No. | Rev TP9-USW-051000-MS-000006 A0 11February 2023


Project Name Sea World Abu Dhabi
Subject Material submittal for steel supports for Stainless Steel Escalator Bollards
Material Sample Ref Discipline Structural
Your Reference TP9-USW-051000-MS-000006 ( A0 ) Zone TO - Tropical Ocean
Reason for Issue Issued for Approval Asset TO - Tropical Ocean

MATERIAL DETAILS
Material Name Stainless Steel Escalator Bollards
Material Type Plate, Pipe and Rod
CSI Code | Discipline 055000 Metal fabrication
Model | Dimension
Specification & Clause
Drawing Reference
BOQ Reference N/A
Material Specified Stainless steel
Material Proposed Stainless steel
Supplier Details Safari Metal / Stainlessinox / Hidayath
Manufacturer Details Viraj profiles / Froch Enterprise / Acerinox Europa
Other Information N/A

☒ Drawings ☒ Copy of related Specs. ☒ Compliance Statement ☐ Material Sample


Enclosure
☒ Catalog / Data Sheet ☐ Prequalification ☐ Test Certificate ☐ Others

The Contractor certifies that the materials submitted have been reviewed and are in accordance with the contract drawings and specifications, except as otherwise stated.

ORIGINATOR’S INFORMATION
REVIEWED AND APPROVED BY GENERAL
REQUESTED BY: REVIEWED AND RECOMMENDED BY:
CONTRACTOR FOR ISSUE

Selvakumar Niaz shanavaz Shanker P G


Office Engineer QC Engineer QA/QC Manager
United steel works United Steel Works ALEC

Distribution

Employer Project Manager Engineer Contractor ☐Others:

Copyright © SeaWorld Parks & Entertainment. All Rights Reserved. TBC

DOCUMENT REVISION HISTORY

REV NO. DESCRIPTION DATE OUR TRANSMITTAL THEIR TRANSMITTAL DATE


A0

FORM NO. MGT-FLP-01311-FO-T00014 This form is for use by Projects Development only and participants should
GENERAL
VERSION 00 register this document in Aconex platform for information, record and
NOTES
REVISION DATE 1 August 2016 future reference.
DISCIPLINE PROJECT MANAGEMENT TRANSMITTAL
FORM NAME FORM OF MATERIAL SUBMITTAL DTD 20160801
FILE LOCATION Z:\QHSE\QC\PROJECT QUALITY DOCS\ALEC\SS CURVED PLATE\1.MATERIAL SUBMITTAL COVER SHEET.DOCX