Confinement required as per IRC 112-2020 Clause 17.2.

Design axial load, NED= 8204.72 KN From Midas


Area of concrete, Ac= 3141593 mm^2
Dia of Pier, D= 2000 mm
fck= 35 Mpa fcd= 15.61
fyk= 500 MPa fyd= 435

Normalized axial force, nk= 0.0746 > 0.064 Confinement required


dia of ain bar= 32 mm Ast= 804 mm^2
No of bar= 60
Longitudinal reinforcement ratio= 0.015
Clear cover= 65 mm
dia of hoop bar, d= 16 mm Asp= 201 mm^2
Spacing of spirals/hoop= 65 mm
Gross area of concrete= 3.142 m^2
Confined dia= 1.87 m
Confined concrete area, ACC= 2.745 m^2
Dia of hoop, Dsp= 1.854 m

Volumetric ratio, = 0.0067


Ww,required= 0.1859

Minimum Confinement Reinforcement


Wwreq= 0.0510
Minimum confinement reinforcement provided is higher of two values
Wwdc= 0.071
0.18 OK

Check for spacing of ties: spacing shall be less than or equal to


5 x dia of smallest longitudinal bar= 160 mm Provided= 65
1/5 thx dia of confined concrete core= 374 mm OK

Extent of Confinement, Lh: larger of the given two


Depth of pier section at bending plane= 2000
Distance upto point of 80% moment= 600

Minimum Transverse reinforcement in column as per Cl. 16.2.3


min dia= 8 mm
max spacing= 200 mm

Hence, upto length of plastic hinge= 2000 mm from base,


provide= 16 mm @ 65 mm c/c

and above that, transverse hoops of 16 mm @ 100 mm c/c