dia of ain bar= 32 mm Ast= 804 mm^2 No of bar= 60 Longitudinal reinforcement ratio= 0.015 Clear cover= 65 mm dia of hoop bar, d= 16 mm Asp= 201 mm^2 Spacing of spirals/hoop= 65 mm Gross area of concrete= 3.142 m^2 Confined dia= 1.87 m Confined concrete area, ACC= 2.745 m^2 Dia of hoop, Dsp= 1.854 m
Volumetric ratio, = 0.0067
Ww,required= 0.1859
Minimum Confinement Reinforcement
Wwreq= 0.0510 Minimum confinement reinforcement provided is higher of two values Wwdc= 0.071 0.18 OK
Check for spacing of ties: spacing shall be less than or equal to
5 x dia of smallest longitudinal bar= 160 mm Provided= 65 1/5 thx dia of confined concrete core= 374 mm OK
Extent of Confinement, Lh: larger of the given two
Depth of pier section at bending plane= 2000 Distance upto point of 80% moment= 600
Minimum Transverse reinforcement in column as per Cl. 16.2.3
min dia= 8 mm max spacing= 200 mm
Hence, upto length of plastic hinge= 2000 mm from base,
provide= 16 mm @ 65 mm c/c
and above that, transverse hoops of 16 mm @ 100 mm c/c