Riser Diagram: Electrical Layout

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

POWER SERVICE

ENTRANCE
1 Ø 230 V 2 WIRE
SPECIFICATIONS: 7. ALL FLOURESCENT LAMPS SHALL BE PROVIDE WITH ELECTRIC BALLAST AND SPRING LOADED
ALL WORKS SHALL COMPLY WITH THE PROVISION OF THE LATEST APPROVED EDITION OF THE LAMPHOLDER.
PHILIPPINE ELECTRICAL CODE, WITH THE RULES AND REGULATIONS OF THE NATIONAL AND LOCAL
AUTHORITY CONCERNED IN THE ENFORCEMENT OF ELECTRICAL LAWS AND ORDINANCES AND WITH 8. CIRCUIT BREAKER SHALL BE "G.E" OR "SQURE D" BUT ONLY ONE BRAND THROUGHOUT. ALL
RULES AND REGULATIONS OF THE UTILITY COMPANY. CIRCUIT BREAKERS FOR TYPE, 10 KAIC FOR BRANCHES AND BOLT-ON TYPE, 22 KAIC FOR MAIN AND
MOTOR LOADS.
2 2 WORK SHALL NOT BE STARTED UNLESS A VALID WIRING PERMIT HAS BEEN SECURED
2-60 MM THW & 1-5.5MM 9. ALL 3.5MM2 HOMERUNS WITH MORE THAN 30 M. IN LENGHT USE 5.5MM2 EVEN IF NOT INDICATED.
1. SERVICE TO THE BUILDING SHALL BE 230 VOLTS, 1 PHASE, 2 - WIRES + GRD.
AS P.E. IN 2.5MM. DIA RIG ID RSC. 10. PRESSED STEEL OUTLET BOXES SHALL BE EPOXY COATED G.A. # 16
2. WIRING METHOD SHALL BE AS FOLLOWS: MINIMUM BEFORE INSTALLATION,
100AT ,2P ,15 KAIC A. POWER FEEDERS AND RISERS - INTERMEDIATE METTALIC CONDUIT (IMC) A. CEILING LIGHT OUTLET - 40MM. DEEP, 1000MM. OCTAGONAL BOX FOR 1 OR 2 RACEWAYS
ENTRIES
B. LIGHTNING AND POWER RECEPTACLE - POLYVINYL CHLORIDE CONDUIT (PVC)
20 A 20 A B. WALL SWITCHES - 55 MM. DEEP UTILITY BOX FOR 1 OR 2 RACEWAY ENTRIES
C1 C2 BRANCH CIRCUIT SCHEDULE 40
PLUG IN PLUG IN
C. WALL RECEPTACLE OUTLET - 55MM. DEEP UTILITY BOX FOR 1 OR 2 RACEWAY ENTRIES.
C. AUXILIARY SYSTEM (VOICE/DATA & - POLYVINYL CHLORIDE CONDUIT (PVC)
D.SPECIAL PURPOSE OUTLET - 40MM DEEP, 100MM2 BOX WITH 1-GANG RAISED COVER OR AS
CABLE SYSTEM SCHEDULE 40
11. MOUNTING HEIGHTS SHALL BE AS FOLLOWS:
3. SMALLEST CONDUCTOR FOR POWER AND LIGHTNING SHALL BE 3.5 MM2 THN. AND SMALLEST A. LIGHT CONTROL SWITCH-120MM. ABOVE FLOOR AT CENTER
RACEWAY SHALL BE TYPE THIN EXCEPT AS OTHERWISE REQUIRED BY THE DRAWINGS & INSULATED
FOR 600 VOLTS. B. CONVENIENCE OUTLET-0.40MM. ABOVE FLOOR AT CENTER, FOR WEATHERPROOF OUTLET
MOUNTING SHALL BE VERTICAL / HINGE ON TOP FOR NON WP OUTLET.
4. NO BRANCH CIRCUIT SHALL HAVE A LOAD OF MORE THAN 80% OF ITS RATING.
C. SPECIAL PURPOSE OUTLET- AS REQUIRED BY EQUIPMENT SERVED.
5. GENERAL USE RECEPTACLES SHALL BE RATED 16A., 250 VOLTS GROUNDING TYPE PARALLEL

RISER DIAGRAM SLOTS.

6. ALL LIGHT CONTROL SWITCHES SHALL BE RATED 164,. 120-277 VOLTS A.C. ONLY.
D. WALL TELEPHONE & TV OUTLET - 0.40MM ABOVE FLOOR AT CENTER UNLESS OTHERWISE
REQUIRED BY FIELD CONDITION.

E. PANEL BOARDERS, MTS ALARM SUPERVISORY AND CONTROL PANE CABINETS.

I J K M O T U

PWD
L N R S
G H

S2.LM S2.NO
FEMALE
MALE T&B
T&B S3.IJK
S2.GH
S2.EF
S2.TU
S2.RS
S2.PQ 2 SCHEDULE OF LOADS AND DESIGN COMPUTATIONS GROUND FLOOR
B P Q
E F

S2.AB
PANELBOARD: PPA-1 "POWER PANEL" ENCLOSURE: NAME NO.1
1
LOCATION: SOURCE:
D C S2.CD A

PANEL: CKT. DESCRIPTIONS PROTECTIVE DEVICE PROTECTIVE DEVICE


LGBT QTY. I.V.A T.V.A VOLTS FLA
NO. NO. OF LOADS AT AF POLE KAIC TYPE PHASE N PE UNIT TYPE RACEWAY
2
RAMP
1 C.L.O.S 10 100 1000 230 4.4 20 50 2 10 BOLT-ON 2-3.5 1-3.5 MM THHN 20MMØ (PVC)

ELECTRICAL LAYOUT 2 C.L.O.S 10 100 1000 230 4.4 20 50 2 10 BOLT-ON 2-3.5 1-3.5 MM
2
THHN 20MMØ (PVC)

200 2000 230 8.8

SIZE OF SUB-MAIN FEEDERS FOR PPA-1: SIZE OF SUB-MAIN PROTECTION FOR PPA-1:
AMPACITY = (0.25*8.3+8.8) = 10.8 AMPS USE: 100AT ,2P ,15 KAIC
2 2
USE: 2-8 MM THW & 1-5.5MM AS P.E. IN 2.5MM. DIA RIG ID RSC. ALL BRANCHES BOLT-ON

PREPARED BY: CERTIFIED: PRC.: PROJECT TITLE: SHEET CONTENTS: SHEET #


PTR.:
P.I.:
D.I:
AS SHOWN E1
ARCH / CIVIL ENGINEER TIN.: OWNER