11/04/2016 plc.myforum.

ro :: View topic ­ Unable to activate Softlogix v21

plc.myforum.ro
PLCs users www.plc.myforum.ro!
 
  FAQ    Search    Memberlist    Usergroups 
  Profile    You have no new messages    Log out [ marlonpetri ] 

Unable to activate Softlogix v21


 

       plc.myforum.ro Forum Index ­> ALLEN­BRADLEY(Rockwell Automation) Reg. U

View previous topic :: View next topic  

Author Message

Norvator Posted: 04/12/2014 01:08    Post subject: Unable to activate Softlogix v21
Junior

Following all the steps, I get 
failed to activate SoftLogix5800: No activations avaialble. 
Joined: 03 Dec 2014
All configured controllers have been removed from the chasis. 
Posts: 2
If you need assistance....... 

Note: I changed with XVI32 address offset of the 3 files 
I need any help. Thanks

Back to top    
residenttiy Posted: 04/12/2014 07:07    Post subject:
Junior

Hello! 
You must replace the files at: C:\Program Files\Rockwell Automation\SoftLogix5800 
Joined: 24 Nov 2014 HEX_Files: 
Posts: 3
https://yadi.sk/d/96X9IFIfd8wad 

Include in .lic fle (C:\Documents and Settings\All Users\Documents\Rockwell
Automation\Activations\ftasystem.lic) )Pre­stop service:FactoryTalk Activation Service): 
FEATURE SftLgx58.60 flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \ 
HOSTID=ANY vendor_info="PRODUCT_NAME:SoftLogix5860" SN=0000000001 \ 
SIGN="0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \ 
FFFF FFFF FFFF FFFF"

Back to top    
raflab Posted: 04/12/2014 15:43    Post subject: Re: Unable to activate Softlogix v21
Junior

Norvator wrote:
Following all the steps, I get 
Joined: 02 Aug 2013
failed to activate SoftLogix5800: No activations avaialble. 
Posts: 8
All configured controllers have been removed from the chasis. 
If you need assistance....... 

Note: I changed with XVI32 address offset of the 3 files 
I need any help. Thanks

I'm facing the same problem as you Norvator, 

please share your solution if you did find one .. i will do the same from my side 

Many thanks

http://plc.myforum.ro/viewtopic.php?p=15053&sid=3f4cefcb27f252e6a7e2c1cf30a8a79d 1/6
11/04/2016 plc.myforum.ro :: View topic ­ Unable to activate Softlogix v21
Back to top
   
Norvator Posted: 04/12/2014 19:35    Post subject:
Junior

residenttiy wrote:
Hello! 
Joined: 03 Dec 2014
You must replace the files at: C:\Program Files\Rockwell Automation\SoftLogix5800 
Posts: 2
HEX_Files: 
https://yadi.sk/d/96X9IFIfd8wad 

Include in .lic fle (C:\Documents and Settings\All Users\Documents\Rockwell
Automation\Activations\ftasystem.lic) )Pre­stop service:FactoryTalk Activation
Service): 
FEATURE SftLgx58.60 flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \ 
HOSTID=ANY vendor_info="PRODUCT_NAME:SoftLogix5860" SN=0000000001 \ 
SIGN="0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \ 
FFFF FFFF FFFF FFFF"

Thanks for the response my friend but I have the same problem: 
I mention what I did : 

1.­I inserted your 3 files 
RSSL5K32.dll 
SLChassisMon.exe 
ftastub.dll 

2.­Then I stopped FactoryTalk Activation Service: 
I wrote in CMD: 
sc stop "FactoryTalk Activation Service" 
sc config "FactoryTalk Activation Service" start= disabled 

3.­After that I include in ftasystem.lic 

# Rockwell Automation License File 
# Copyright (C) 2003­2010 All Rights Reserved 

SERVER this_host ANY 
USE_SERVER 
VENDOR flexsvr 

FEATURE SftLgx58.60 flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \ 
HOSTID=ANY vendor_info="PRODUCT_NAME:SoftLogix5860" SN=0000000001 \ 
SIGN="0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \ 
FFFF FFFF FFFF FFFF" 

4.­Enable FactoryTalk Activation Service 

Attached image license in Factory Talk Activation Manager 

http://plc.myforum.ro/viewtopic.php?p=15053&sid=3f4cefcb27f252e6a7e2c1cf30a8a79d 2/6
11/04/2016 plc.myforum.ro :: View topic ­ Unable to activate Softlogix v21

still appears activation fails, I tried restarting the pc and nothing. 
I appreciate any suggestions. Thanks

Back to top    
sanchez1139 Posted: 22/02/2015 05:46    Post subject:
Junior

Norvator wrote:

Joined: 18 Feb 2015 residenttiy wrote:
Posts: 1 Hello! 
You must replace the files at: C:\Program Files\Rockwell
Automation\SoftLogix5800 
HEX_Files: 
https://yadi.sk/d/96X9IFIfd8wad 

Include in .lic fle (C:\Documents and Settings\All Users\Documents\Rockwell
Automation\Activations\ftasystem.lic) )Pre­stop service:FactoryTalk Activation
Service): 
FEATURE SftLgx58.60 flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \ 
HOSTID=ANY vendor_info="PRODUCT_NAME:SoftLogix5860" SN=0000000001 \ 
SIGN="0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \ 
FFFF FFFF FFFF FFFF"

Im having same error, done all that is told in posts , any one help ? 

Thanks for the response my friend but I have the same problem: 
I mention what I did : 

1.­I inserted your 3 files 
RSSL5K32.dll 
SLChassisMon.exe 
ftastub.dll 

2.­Then I stopped FactoryTalk Activation Service: 

http://plc.myforum.ro/viewtopic.php?p=15053&sid=3f4cefcb27f252e6a7e2c1cf30a8a79d 3/6
11/04/2016 plc.myforum.ro :: View topic ­ Unable to activate Softlogix v21

I wrote in CMD: 
sc stop "FactoryTalk Activation Service" 
sc config "FactoryTalk Activation Service" start= disabled 

3.­After that I include in ftasystem.lic 

# Rockwell Automation License File 
# Copyright (C) 2003­2010 All Rights Reserved 

SERVER this_host ANY 
USE_SERVER 
VENDOR flexsvr 

FEATURE SftLgx58.60 flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \ 
HOSTID=ANY vendor_info="PRODUCT_NAME:SoftLogix5860" SN=0000000001 \ 
SIGN="0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \ 
FFFF FFFF FFFF FFFF" 

4.­Enable FactoryTalk Activation Service 

Attached image license in Factory Talk Activation Manager 

still appears activation fails, I tried restarting the pc and nothing. 
I appreciate any suggestions. Thanks

Back to top    
psgama Posted: 22/02/2015 21:47    Post subject:
Junior 2

Have you applied the Hex edit as follows? 
Code:
Joined: 24 Mar 2014
Posts: 44
C:\Program Files\Common Files\Rockwell\FTAcommon.dll 

Example 

http://plc.myforum.ro/viewtopic.php?p=15053&sid=3f4cefcb27f252e6a7e2c1cf30a8a79d 4/6
11/04/2016 plc.myforum.ro :: View topic ­ Unable to activate Softlogix v21
Factory Activation Software 3.51.0.0040 
Using FLEXnet Licensing v11.10.0.3 build 96515 i86_n3 (lmgr.lib) 

Patch to allow licenses 
********************* 
Hexedit flexsvr.exe at address E4D0 
From 55 8B EC 83 E4 F8 81 EC To 33 C0 40 89 45 FC 48 C3 
********************* 

Patch to accept licenses 
********************* 
Hexedit C:\Program Files\Common Files\Rockwell\FTACommon.dll at
address 40FB9 
From 34 02 To 30 90 
********************* 

Back to top    
psgama Posted: 26/02/2015 03:12    Post subject:
Junior 2

And make sure to make a backup of your flexsvr.exe and ftacommon.dll files if you have a
legitimate license from a concurrent license server that you're using. 
Joined: 24 Mar 2014
Posts: 44
The actual Hexedits to be made for Version 21.03.00 as follows 

Code:
Patch Factory Talk Activation as Required. 

Hexedit C:\Program Files\Rockwell
Automation\SoftLogix5800\RSSL5K32.dll 
********************** 
Address:FC339 
From 34 02 
To   30 90 
********************** 
Hexedit C:\Program Files\Rockwell
Automation\SoftLogix5800\FTAstub.dll 
********************** 
Address:FCD 
From 40 03 
To   09 00 
********************** 

Hexedit C:\Program Files\Rockwell
Automation\SoftLogix5800\SLChasismon.exe 
********************** 
Address:12086 
From 0F 85 46 03 00 00 
To   E9 2C 00 00 00 90 
**********************

Back to top    
raflab Posted: 27/02/2015 00:33    Post subject:
Junior

Many thanks psgama, 

Joined: 02 Aug 2013 It worked for me finally :DD
Posts: 8

Back to top    
psgama Posted: 27/02/2015 04:01    Post subject:
Junior 2

You are much welcome. Glad to assist.

Joined: 24 Mar 2014
Posts: 44

http://plc.myforum.ro/viewtopic.php?p=15053&sid=3f4cefcb27f252e6a7e2c1cf30a8a79d 5/6
11/04/2016 plc.myforum.ro :: View topic ­ Unable to activate Softlogix v21

Back to top    
carlito Posted: 22/04/2015 17:18    Post subject:
Member

ftom forum Softlogix5800_V21 
Quote:
Joined: 02 Feb 2014
Posts: 180 https://mega.co.nz/#F!iB0TAbIS!0u8ASSDvS21eqmMRMC4HrQ

Back to top    
AdBot Posted: 23/04/2016 03:37    Post subject: AdBot
Robotelul cu reclame

Ce este AdBot ? 
Click aici

Back to top  

Display posts from previous:  All Posts   Oldest First   Go

       plc.myforum.ro Forum Index ­> ALLEN­ All times are GMT + 2 Hours


BRADLEY(Rockwell Automation) Reg. U
Page 1 of 1
Watch this topic for replies Jump to:  ALLEN­BRADLEY(Rockwell Automation) Reg. U   Go
 
You can post new topics in this forum
You can reply to topics in this forum
You can edit your posts in this forum
You cannot delete your posts in this forum
You can vote in polls in this forum

Powered by phpBB © 2001, 2005 phpBB Group
Fa­ti si tu propriul forum GRATUIT, pe www.myforum.ro

http://plc.myforum.ro/viewtopic.php?p=15053&sid=3f4cefcb27f252e6a7e2c1cf30a8a79d 6/6

You might also like