STN6800-X 10 U Otn
STN6800-X 10 U Otn
STN6800-X 10 U Otn
STN6800-X
10U OTN / WDM Transport Platform
Overview:
STN6800-X is a 10U height new generation OTN/WDM transport platform. Adopting the advanced technology
and ASIC chip, it is fully compliant with ITU-T standard, such as G.709, G.798, etc.
STN6800-X has 16 universal service slots, modular design enables any type of OTN card (100G, 40G, 10G,
any-rate below 10G) and any type of CWDM and DWDM card. With high capacity and STN6800-X and
expansion ability, STN6800-X is suitable for metro aggregation and long-haul optical transport network.
Features:
Description Description
Slot 1 ----------------- DC PWR (only) Slot 1 --------------- DC PWR (only)
slot 19 ---------------- DC PWR (only) slot 19 -------------- DC PWR (only)
Slot 2~Slot 17 ------ Full slot OTN cards, DWDM cards Slot 2~Slot 6 ------ Full slot OTN cards, DWDM cards
Slot 18 ---------------- SC Card (only) Slot 7~Slot 12 ---- Half slot OTN cards, DWDM cards
Slot 20 ---------------- SC Card (only) Slot 13~Slot 17 --- Full slot OTN cards, DWDM cards
Slot 21 ---------------- Fan Tray (only) Slot 23~Slot 28 --- Half slot OTN cards, DWDM cards
Slot 22 ---------------- SI Interface (only) Slot 18 --------------- SC Card (only)
Slot 20 --------------- SC Card (only)
Slot 21 --------------- Fan Tray (only)
Slot 22 --------------- SI Interface (only)
Physical Characteristics:
Characteristics Description
Shelf Type and
DC version: 440mm*245mm*44mm
Dimensions(mm) (W*D*H)
AC: Input 100~240V, 47~63Hz
Power Supply
DC: Input -40V~-72V
Power consumption 130W with coherent CFP
110W with grey CFP
10 SFP+ based 10G ports (10GE LAN/WAN, STM-64/OC-192, FC8G,
Client Interface
OTU2, OTU2e)
System Interface One CFP based 100G port (coherent CFP, 4x25G DWDM CFP, grey CFP)
DWDM/CWDM SFP+ based 10G port
Working temperature:-5C~50C
Environment Storage temperature:-40C~70C
Relative humidity:10%~90%,no condensing
Technical Specification :
Features Description
⚫ 100G grey CFP: OTU4 <-> ODU4 <-> ODU2 or ODU2e or ODUflex
System Side Signal and ⚫ 100G DWDM CFP: Och <-> OTU4 <-> ODU4 <-> ODU2 or ODU2e
or ODUflex
Multiplexing Structure
⚫ 10G grey SFP+: OTU2/OTU2e <-> ODU2/ODU2e
⚫ 10G WDM SFP+: Och <-> OTU2/OTU2e <-> ODU2/ODU2e
⚫ OC-192/STM-64 (via AMP or BMP) <-> ODU2
⚫ 10GBASE-R (via BMP) <-> ODU2e
Client-Side Signal and Mapping ⚫ 10GBASE-R (via GFP-F) <-> ODU2
Mode ⚫ 10GBASE-R (via GFP-F extended payload with preamble) <->
ODU2
⚫ FC8G (via BMP) <->ODUflex (HW ready)
⚫ 100G OTU4: G.709 Regular FEC
FEC on 100G Port
⚫ 100G coherent Och: Soft-Decision FEC
⚫ Regular FEC (G.709)
FEC on 10G Port ⚫ I.4 Super FEC (G.975.1)
⚫ I.7 Super FEC (G.975.1)
⚫ GCC0 on OTU4
⚫ GCC1 or GCC2 or GCC1+2 on ODU4
In-band DCN Management ⚫ GCC0 on OTU2/2e
⚫ GCC1 or GCC2 or GCC1+2 on ODU2/2e
Out-band DCN Management ⚫ Management Ethernet port
⚫ SNC/N
Transmission Protection
⚫ SNC/I
Network Management System ⚫ SNMP based NMS
Applications :
1. Point to P oint