Frame Connection To Steel Substrate Through Buck D: Roof Plan Upper

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ROOF NOTES

20049
FINAL TRUSS ENGINEERING REACTIONS AND UPLIFTS IN EXCESS OF 3000#
MUST BE SUBMITTED PRIOR TO FINAL APPROVAL, PERMANENT TRUSS single truss or
BRACING TO BE BY TRUSS ENGINEER OF RECORD. ARCHITECT'S LAYOUT TO girder
BE USED FOR UPLIFT AND TRUSS / STRAP INSTALLATION
5/8" FIRE CODE GYPSUM
TYP. ALUM WINDOW BOARD EACH SIDE
OR DOOR. JAMB DRAFT STOP NOTE

1615 south federal highway + suite 206


THE MAXIMUM AREA UNDER ONE ROOF IS 3000 S.F. PER DRAFT STOP
ATTACH TO STEEL THRU BUCK W/ #12 & ALL DRAFT STOP'S ARE TO HAVE 30-30 DOORS W/ CLOSERS & SIGNS.
STAINLESS STEEL SELF DRILLING ( SIGN MUST READ "THIS DOOR MUST REMAIN CLOSED AT ALL TIMES!" ) TRUSS
SCREWS @ 12" O/C STAGGERED, 4" ONLY IF AN ATTIC ACCESS CAN NOT BE LOCATED TO ENTER THE AREA.
GIRDER
FROM EACH END. # SEE TYPICAL DETAIL SHEET AND CORRESPONDING NUMBER

boca raton + florida + 33432


LOADING THIS LEVEL
DEAD (92 PSF) SYSTEM SELF WEIGHT= 66 PSF

tel: 561.672.7124
www.intelae.com
FLOOR FINISHES = 20 PSF
DUCTWORK = 4 PSF
CEILINGS = 2 PSF
1x P.T. WOOD NON STRUCTURAL BUCK LIVE (30 PSF) OCCUPANCY LIVE = 30 PSF
STEEL EL. 10'2" T.O.B. ELEVATION CHANGE

SUBSTRATE EL. 12'2" T.O.PL. BEAM SCHEDULE T.O.B. = TOP OF BEAM T.O.PL. =
TOP OF PLATE
SEE ARCH PLANS FOR EXTERIOR SIZE REINFORCING
MARK #3 STIRRUP OR HOOPS REMARK
AND INTERIOR FINISHES W D TOP MID BOT
T8 8" 12" 2 #5 - 2 #5 NONE REQUIRED TYPICAL 8" TIE-BEAM
1/4" PER FOOT SLOPE TOP CORD
T 12 12" 12" 3 #5 - 3 #5 NONE REQUIRED TYPICAL 12" TIE-BEAM
PCL 8" 8" (1) #5 GROUT SOLID PRECAST CONCRTE LINTEL W/ T 8 ABOVE TYPICAL
1. FOR ALL CONDITIONS IN WHICH A PRE-CAST LINTEL IS INSTALLED ABOVE A MASONRY OPENING (AS DESIGNATED IN THE
FRAME CONNECTION TO STEEL ABOVE SCHEDULE), CONTRACTOR SHALL GROUT SOLID ALL CELLS ABOVE THE OPENING. NO ADDITIONAL REBAR IS
REQUIRED.
2. STIRRUPS ARE ONLY SPECIFIED WHERE REQUIRED FOR STRENGTH. STIRRUPS MAY BE PLACED, AT THE CONTRACTORS

SUBSTRATE THROUGH BUCK 3.


OPTION, FOR BAR SUPPORT DURING CONCRETE POUR.
SCHEDULE HOOPS OR STIRRUPS SHALL BE PLACED AT EACH END (E.E.) OF BEAM THROUGHOUT (T.O.) BEAM AS INDICATED
D ON BEAM SCHEDULE. STIRRUPS SHALL BE TYPE S-3 AND HOOPS SHALL BE TYPE-1 TYPICAL ACRSI BAR BENDS UNLESS
OTHERWISE NOTED.
SCALE:N.T.S. 16"X2"
4.
5.
ALL BEAM (B) TOP BARS SHALL BE CONTINUOUS UNLESS OTHERWISE NOTED.
ALL TIE BEAMS (MARK "TB" ONLY) REINFORCING SHALL BE CONTINUOUS THROUGH TIE BEAMS ONLY.
EMERGENCY 6. WHERE NOTED ON SCHEDULE TOP BAR SHALL BE BUNDLED 1 PAIRS OVER SUPPORTS WITH TOP BAR FROM ADJACENT
4/5/2021
OVERFLOW BEAMS AS PER BENDING DIAGRAM.
SCUPPER 7. DROP BOTTOM OF TIE BEAMS AS REQUIRED AT WINDOW AND DOOR HEADS (28" MAXIMUM) AND ADD TWO #5 BOTTOM IF
3" MAX ABV LOW TRELLIS BY STRUCTURAL ENGINEER DROP EXCEEDS 8".
POINT 8. ALL ADDED LONGITUDINAL BEAM REINFORCING SHALL EXTEND 6" MINIMUM INTO SUPPORT UNLESS NOTED OTHERWISE.
CONCRETE TIE BEAM OPEN AND CLOSE LONG BARS 9. REFER TO GENERAL NOTES FOR INFORMATION ON CONCRETE AND STEEL SPECIFICATIONS.
SEE PLAN BETWEEN STIRRUPS NOT TO 10. CONCRETE FOR COLUMNS AND BEAMS SHALL HAVE 5,000 PSI COMPRESSIVE STRENGTH IN 28 DAYS.
3-7/8" OUTSIDE DIAMETER PIPE EXCEED THE 1.5" CONC. COVER. 11. THE SHELL CONTRACTOR MAY ELECT TO POUR THE BEAM AS A FULL HEIGHT BEAM IN ORDER TO HAVE A SINGLE
APPLY SPRAY GALVANIZED RAIL CONCRETING OPERATION. IN THIS CASE, ADD 2#5 PER EVERY ADDITIONAL 24" OF BEAM DEPTH TO BE ADDED TO THE
ORIGINAL BEAM IN THE SCHEDULE.
ROOF DRAIN

48"

PLUMBING RISER & CONC. BEAM 1/4" DROP PER FOOT


C
SCALE: 3/4" = 1'
1/4" PER FOOT SLOPE TOP CORD

POURED CONCRETE

1650 EAST TERRA MAR DRIVE


LAUDERDALE BY THE SEA, FL
HEADER BEAM OVER DOOR
OR WINDOW. ALL OUR
ELEVATIONS
GIVEN ARE TOP OF BEAM
= T.O.B, SEE PLAN FOR

1/4" PER FOOT SLOPE TOP CORD

1/4" PER FOOT SLOPE TOP CORD


VALUE, UNLESS
OTHERWISE NOTED. B-8-16
2#5 T&B
2 -
#3@24"OC
A19
-IF OUR SCHEDULED BEAM DEPTHS ARE 2" SHORTER MAIN DOWNSPOUT WITH 4/5/2021
THAN WHAT THEY NEED TO BE TO REACH THE WINDOW EMERGENCY SCUPPER 3" ABV
SEE ARCHITECTURALS OR DOOR TOP FRAME, IT IS TO ALLOW FOR THE

BRICKER 1650 LLC


TO DETERMINE IF A THICKNESS OF A POSSIBLE BUCK.
BUCK IS REQUIRED
AND OF WHICH SIZE. -IF NO BUCK IS BEING USED, ANY HEADER BEAM CAN BE Y
MADE DEEPER TO MEET THE MASONRY OPENING
WINDOW OR DOOR U=310
PER ARCHITECTURALS REQUIRED BY THE BUILDER. IN THIS CASE, YOU WILL
HAVE A CONCRETE COVER TO THE STIRRUPS THAT IS
GREATER THAN 1.5". THAT IS ACCEPTABLE, HOWEVER IF
THE COVER WILL BECOME LARGER THAN 4", ADD 2#5
BOTTOM BARS TO THE BEAM.
-WHEN BEAMS ARE MADE DEEPER, THEY BECOME
STRONGER.
-NO BEAM MAY BE BUILT SHALLOWER WITHOUT
ENGINEER APPROVAL.

ROOF
WOOD JOIST
DRAIN
2X6@24" O.C.

B BEAM DEPTH EXPLANATION


SCALE: 3/4" = 1' 1/4" DROP PER FOOT

SOLAR PANELS ON METAL MS5 PURLINS BY LUMOS


(SEE LUMOS PANELS AND RAILS FOR MORE DETAILS)
UNDER SEPARATE PERMIT 4/5/2021

ATTACHING TO :
- WOOD RAFTERS OR TRUSSES :HANGER STUDS
MUST TRAVEL FURTHER UP TO SIDELAP THE
WOOD MEMBER. USE (3) #10 STAGGERED WOOD SCREWS
- UNDERSIDE OF CONCRETE SLAB :
(2) 1/4" x 2-1/4" TAPCONS
- UNDERSIDE OF ANY PRE-STRESSED SYSTEM SUCH 1/4" DROP PER FOOT
AS HOLLOWCORE (4) HILTI X-DNI (0.145" DIAMETER)
WITH 3/4" MAXIMUM EMBEDMENT .
- UNDERSIDE OF HOLLOW LIGHT GAGE STEEL :
(4) #10 SELF DRILLING SCREWS (# 3 POINT)
-UNDERSIDE OF HOLLOW LIGHT GAGE STEEL : 2/24/2021

10/19/2020 - PERMIT SET


(4)#10 SELF DRILLING SCREWS (# 3 POINT)
-UNDERSIDE OF CONCRETE RAFTERS :
3-5/8"X 12" (2) 1/4" x 2-1/4" TAPCONS
LONG TRACK. -UNDERSIDE OF STEEL JOIST BOTTOM CHORD:
(2) #10 SELF DRILLING SCREWS PER CHORD ANGLE.
16"X2"
EMERGENCY

CHKD RPM l RJR


OVERFLOW

©2019 - AA26002874
SCUPPER
AT HIGH POINT
OF ROOF
ALL STEEL TO BE

REVISIONS
GALVANIZED
G-90 3-5/8 STUDS

DATE

+ ENERGY
(2) #10 SELF DRILLING
SCREWS (#3 POINT)
5/8" P.T. PLYWOOD OR DENSGLASS ATTACHMENT
TO STEEL STUDS SHALL BE WITH:

ARCHITECTURE
#10 SELF DRILLING SCREWS WITH #3 POINT @ 6" O/C. 1
A19
EXTERIOR APPLICATIONS : GRID SPACING TO BE @24" x 16"O/C , 20 GA
INTERIOR APPLICATIONS : GRID SPACING TO BE @24" O/C , 20 GA

CEILING FRAMING DETAIL


A
SCALE: 3/4" = 1'
ROOF PLAN UPPER 1/4" = 1'-0"
A15