DATASHEET

Flexy 205
IIOT GATEWAY AND REMOTE ACCESS ROUTER
Highlights
• IIoT gateway with most PLC
protocols

• Flexible WAN interface:


Ethernet, 4G, 3G, WiFi

• High performance for data


processing

• Data logging and alarm


notification

• OPC UA & Modbus server

• Compact and robust design,


ideal for electrical cabinet

• Easy to set up through


embedded web pages

• MQTT scripting to connect with


IIoT Platforms eWON Flexy 205 is a compact modular gateway for collecting Remote
Data and providing Remote Access to your industrial equipment. With
• SD card ready for easy a configurable WAN/LAN switch, this gateway offers a wide range of
commissioning extension cards to best fit your application and is perfect for data-intensive
applications. Whether your requirements are to: create alarms, monitor
dashboards, collect data for machine performance analysis, or even other
Typical Applications advanced solutions, the Flexy 205 will meet your needs and expand your
possibilities.

• Remote Data Collection with Like other routers from the Flexy family, the Flexy 205 has a web-based
IIoT platforms configuration and built-in scripting tools for customization.

• Remote Monitoring Through the use of our Talk2M APIs, HTTPs scripting, or MQTT scripting, we
enable easy integration with your favorite IIoT platform. The flexibility and
• Remote Access robustness of the Flexy 205 guarantees a wide array of value-add services
for Machines Builders.

4G EU/NA/VERIZON CELLULAR 3G+ WIFI ETHERNET MPI DUAL SERIAL 3 USB Ports I/O
WAN PORTS Card

www.ewon.biz
GENERAL FEATURES
Routing Routing capability between LAN and WAN Ethernet interface and
Ethernet to serial gateway

Ethernet to Serial Gateways MODBUS TCP to MODBUS RTU; XIP to UNITELWAY; EtherNet/IP™ to DF1; FINS
TCP to FINS Hostlink; ISO TCP to PPI, MPI (S7) or PROFIBUS (S7); VCOM to ASCII.
Data Acquisition Protocols OPC UA, MODBUS/RTU, MODBUS/TCP, Unitelway, DF1, PPI, MPI (S7),
PROFIBUS (S7), FINS Hostlink, FINS TCP, EtherNet/IP™, ISO TCP, Mitsubishi
FX, Hitachi EH, ASCII, BACnet/IP. Stored in 2500 internal tags
Data Publishing Protocols OPC UA, Modbus, MQTT, SNMP
Alarms Alarms notification by email, SMS, FTP put and/or SNMP traps.
4 Thresholds : low, lowlow, high, highhigh + deadband and activation
delay.Alarm logs in http and via FTP, Alarm cycle: ALM, RTN, ACK and END
Datalogging Internal data base for data logging (real-time logging and historical
logging up to 1,000,000 timestamps). Retrieval of the database with files
transferred by FTP or email
SD card reader YES, for easy commissioning (firmware upgrade, backup, Talk2M registration).
Router IP filtering, IP forwarding, NAT, Port forwarding, Proxy, Routing table, DHCP
client/server

VPN Tunnelling Open VPN either in SSL UDP or HTTPS


VPN Security VPN sessions are end-to-end encrypted using SSL/TLS protocol.
Communications between the remote user and the eWON are
fully encrypted using the SSL/TLS protocol, thereby ensuring data
authenticity, integrity & confidentiality. Indeed, all users and eWON
units are authenticated using x509 SSL certificates and end-to-end
traffic is encrypted using strong symmetric & asymmetric algorithms
that are part of the SSL/TLS protocol cipher suite.
Programmable Script interpreter for Basic language, Java 2 Standard Edition
environment
Synchronization Embedded real-time clock, manual setup via http or automatic via NTP
File Management FTP client and server for configuration, firmware update and data transfer
Website Embedded web interface with setup wizards for configuration and
maintenance (no extra software needed). Authentication with login/
password and session control for security.
Possibility of uploading custom web GUI. Compatible with viewON
web HMI.
User Flash Disk up to 30MB available for user application
Maintenance SNMP and/or via FTP files

FLEXY 205 BASE MODULE


Mechanicals Din Rail or wall screw fixing system
Dimensions: 133 x 122 x 55 mm (H x D x W );
Weight: 280 g without extension card
Power supply 12 - 24VDC +/-20%, LPS
Consumption: depending on the extension card installed (see
Installation guide on our website)
Input/output 2x digital input: 0 to 12/24VDC; 1.5kV isolation
1x digital output: open drain (MOSFET) 200mA; 1.5 kV isolation
Flexy 205 base module interface 4 x RJ45 Ethernet 10/100 Mb .Configurable LAN/WAN ports, port 1
always LAN
FLEXY EXTENSION CARDS
Dual serial ports (FLA3301)
Number of ports 1x male SUBD9 serial port RS232/422/485 configurable by dipswitch and
1x male SUBD9 RS232 serial port with RTS, CTS signals

Cellular 3G+ (FLB3202)


Frequencies Pentaband UMTS/HSPA+ modem (800/850, 900, AWS1700, 1900, 2100 MHz)
Quad band GPRS/EDGE (850, 900, 1800, 1900 MHz)
Antenna Connector Type SMA - Female
Antenna Not included in the delivery

EU 4G LTE (FLB3204)
Frequencies 4G: B7(2600), B1(2100), B3(1800), B8(900), B20 (800)MHz
3G: B1 (2100), B8 (900) MHz
2G: B3 (1800) , B8(900) MHz
Antenna Connector Type SMA - Female
Antenna Not included in the delivery

NA 4G LTE (FLB3205)
Frequencies AT&T compliant
4G: B12/B17(700),B5(850), B4(AWS1700),B2(1900), B13(700)MHz
3G: B2(1900), B5(850)MHz
Antenna Connector Type SMA - Female
Antenna Not included in the delivery

Verizon 4G LTE (FLB3203)


Frequencies only Verizon network compatible, no CDMA
4G: B4(AWS1700), B13(700) MHz
Antenna Connector Type SMA - Female
Antenna Not included in the delivery

WiFi (FLB3271)
Wan connectivity WiFi: 802.11 b/g/n WiFi/WLAN client for remote connection
Frequencies Channels: 1 to 11 ( inclusive )
Security WPA2, WPA and WEP
Antenna Connector Reverse SMA male connector
Antenna included in the delivery; frequency: 2.4 GHz; impedance: 50 Ohms,
gain:2.0 dB

I/O card (FLX3402)


Number of inputs/output I/O card with 8x DI, 2x DO, 4x AI (0-10V, 4-20mA)
Range AI : voltage mode 0-10V - 16 bit resolution or current mode 4-20mA,
user selectable with Dip Switch configuration. DI : 0 to 12/24 VDC,DO:
2A/30V VAC/VDC
Isolation AI: 1.5kV from power supply, DI: 1.5 kV from electronic AND power
supply, DO: 1.5kV from electronic AND from power supply
3 USB Ports Card (FLB3601)
Leds 4 leds : 1 global status, 1 for each port status
Connector Type A female
Current limit Each port has its own 500mA current limit. Global current limit on the board
is 500mA
Port activation All ports will be enabled/disabled together
Isolation Earth GND isolation is limited to 500V due to USB connector design

Ethernet WAN (FLX3101)


Ethernet port 1x RJ45 Ethernet 10/100 base Tx; 1.5kV isolation

MPI (FLC3701)
1 x female SUBD9 MPI port, 1.5kV functional isolation from power supply

GENERAL CHARACTERISTICS, STANDARDS & DIRECTIVES


Temperature Range
base modules and extension cards Operating: -25°C to +70°C, 10 to 95% relative humidity (non-condensing)
Storage: -40°C to +70°C, 10 to 95% relative humidity (non-condensing)
Marking FCC
Warranty 36 months
Type tests Temperature - Operating & Storage tested according to:
IEC 60068-2-1 Cold test
IEC 60068-2-2 Dry heat test
IEC 60068-2-14 Change of temperature
IEC 60068-2-30 Cyclic damp heat test
Vibration & shocks tested according to:
IEC 60068-2-27 Bumps
IEC 60068-2-64 Vibration (broad-band random)
IEC 60068-2-6 Vibration (sinusoidal)
CE Compliant with:
EMC directive 2014/30/EU
RE directive 2014/53/EU*
LV directive 2014/35/EU*
RoHS directive 2011/65/EU
REACH regulation 1907/2006
According to standards:
EMC: ITE emission Class A and Immunity
EN55032; EN55024
EN301489-1*; EN301489-17*; EN301489-52*
Spectrum*:
EN301511; EN301908-1; -2 & 13
EN300328
Health: EN62311
Safety: EN60950
FCC Compliant with: CFR 47, part 15B class A; 15C*; 22H*; 24E*; 27*; 68*
IC Compliant with IC (Industry Canada) RSS-130 -132; RSS-133; RSS-139;
RSS-210
Japan This equipment has the Type Approval Certification based on the
Radio Law
* when applicable depending on the plugged EXT cards
Safety Conform to:
EN60950-1; UL60950-1; CSA-C22.2 n° 60950-1-07
UL recognized: file number E350576

PART NUMBER
Base Module Part Number
Flexy 205 Flexy205

Extension Cards
Dual serial ports FLA3301
Cellular 3G+ FLB3202
EU 4G LTE FLB3204
NA 4G LTE FLB3205
VERIZON 4G LTE FLB3203
WIFI FLB3271
3 USB Ports Cards FLB3601
Ethernet WAN FLX3101
Extension I/O card FLX3402
MPI FLC3701

HMS - Sweden (HQ) HMS - Germany HMS - Switzerland


Tel : +46 35 17 29 00 (Halmstad HQ) Tel: +49 721 989777-000 Tel: +41 61 511342-0
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]

HMS - Belgium (eWON) HMS - India HMS - UK


Tel: +32 67 895 800 Tel: +91 83800 66578 Tel: +44 1926 405599
Rev 1.0. Subject to change without notice.

E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]

HMS - China HMS - Italy HMS - United States


Tel : +86 010 8532 3183 Tel : +39 039 59662 27 Tel: +1 312 829 0601
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]

HMS - France HMS - Japan


Tel: +33 (0)3 67 88 02 50 (Mulhouse office) Tel: +81 45 478 5340
E-mail: [email protected] E-mail: [email protected]

www.ewon.biz

You might also like