0% found this document useful (0 votes)
387 views1 page

PT Pressure Transmitter

This document provides specifications for a diaphragm pressure transmitter used to measure pressure of demineralized water and caustic potash solution in an underwater granulator. Key details include: - The transmitter will measure pressure between -1 to 21.1 kgf/cm2-g on the granulator line. - It has a 316L stainless steel capsule element and wetted parts made of 316 stainless steel. - The transmitter will be made by Emerson and have an accuracy of ±0.05% over 5 years. - It will be mounted using 2-inch brackets and measure pressure on a 4-inch sch. 10 carbon steel line connected to the granulator vessel.

Uploaded by

Ar Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
387 views1 page

PT Pressure Transmitter

This document provides specifications for a diaphragm pressure transmitter used to measure pressure of demineralized water and caustic potash solution in an underwater granulator. Key details include: - The transmitter will measure pressure between -1 to 21.1 kgf/cm2-g on the granulator line. - It has a 316L stainless steel capsule element and wetted parts made of 316 stainless steel. - The transmitter will be made by Emerson and have an accuracy of ±0.05% over 5 years. - It will be mounted using 2-inch brackets and measure pressure on a 4-inch sch. 10 carbon steel line connected to the granulator vessel.

Uploaded by

Ar Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 Tag Number P450-PT -4621

2 Service CPL/WATER TO UNDERWATER GRANULATOR B Z-4620


GENERAL 3 P&ID No. D-EP-P450-1225-1462
4 Design Pressure Min. Max. -0.1 kgf/cm2-g 14.3 kgf/cm2-g
5 Design Temp. Min. Max. degC 90 degC
6 Fluid Name DEMI.WATER+CPL
PROCESS 7 Fluid State Liquid
CONDITIONS 8 Pressure Min. Nor. Max. kgf/cm2g 5.74 5.75
9 Temperature Nor. 20 degC
10
11 Element Type DIAPHRAGM
12 Transmitter Type Electronic SMART
13 Instrument Range -1 ~ 21.1 kgf/cm2-g
14 Set Range 0 ~ 10 kgf/cm2-g
15 Material Capsule Element 316L SS
16 Capsule Other 316 SS
17 Vent / Drain & Plug 316 SS
UNIT 18 Enclosure Low Copper Aluminum
19 Connection Size Rating Type 1/2 in CL None NPT(F)
20 Elec. Haz. Protection STD Method Gr. Temp. ATEX EExd Group IIC T6
21 Weather Protection IP66
22 Output Signal FF
23 Power Supply 24V DC Loop Power
24 Electrical Connection M20 x 1.5
25 Accuracy ± 0.05%(5years stability)
26
27 Seal Type
28 Material Diaphragm
29 Other Wetted Parts
30 Flange
DIAPHRAGM
31 Connection Size Rating
SEAL
32 Type Facing
33 Capillary Type Material
34 Capillary Length m
35 Fill Fluid
36 Integral Meter LCD INDICATOR
37 Failure Alarm Scale
38 Manifold Type Material 2-Valve 316 SS
OPTIONS 39 Packing & O-ring Material Graphite
40 Manufacturer Model Emerson 0304RT22B21L4
41 Mounting Brackets 2" Mounting Bracket w/ U-Bolt&Nut
42 Line Number 4"-PLW-P450-1055-1SA0P58-IC
43 Size Class Sch. 4in 1SA0P58 10S
LINE/VESSEL
44 Vessel Number
45 Class
46 Manufacturer Emerson
PURCHASE 47 Model 2051CG4F02A1BH2S6E1L4M5P8P1Q4Q8
48 Requisition No. R-207-2173-4361
NOTES:

5 2/4/2016 For Construction M.H.A Y.G.S Y.I.C


INSTRUMENT SPECIFICATION
4 9/1/2015 For Approval M.H.A Y.G.S K.M.L
FF_Pressure Instrument
3 6/8/2015 For Approval M.H.A Y.G.S K.M.L
2 2/2/2015 For Approval H.P.J Y.G.S K.M.L
1 9/26/2014 For Review H.P.J Y.G.S Y.I.C
No Date Description Pred By Chked By Appr By Doc. No.: P450-PT -4621 Sheet 1 of 2 Rev.: 5