The document provides instructions for operating an automatic sliding gate control panel in different modes. It describes how to set the auto close time from 1 to 4 minutes and how the light will flash when the gate is moving. It also explains how to program remote controls, adjust the total operating time, and set the motor force.

Uploaded by

user user
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views1 page

SLIDING A (En) PDF

The document provides instructions for operating an automatic sliding gate control panel in different modes. It describes how to set the auto close time from 1 to 4 minutes and how the light will flash when the gate is moving. It also explains how to program remote controls, adjust the total operating time, and set the motor force.

Uploaded by

user user
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

AUTO CLOSE MODE SLIDING GATE ELECTRONIC LIGHT - FLASHING LIGHT

When microswitch ( 2 ) is set (ON) the circuit board will be CONTROL PANEL SYR-790-A EACH TIME the remote or the button is pressed
operating in the automatic closing mode (Auto Close Mode). the LIGHT will be activated for about 3 minutes
The LIGHT will become a FLASHING LIGHT if
SETTING THE AUTO CLOSE TIME switch (3) is set. The FLASHING LIGHT
Auto Close is set to 1 minute. To adjust the preset time length: will flash on and off for as long as the motor is running, or
Press the LEARN button and KEEP IT PRESSED. - in the Auto Close mode- until the door closes.
After about 7 seconds the indication light (LED) (If there is some kind of obstacle blocking the photocell,
will flash one time and then immediately two times, the FLASHING LIGHT will stop
three times and four times and if you continue to keep the functionning after 5 minutes. It will resume its
button pressed, the cycle will be repeated. LEARNCLEAR 1 2 3 operation when the obstacle is removed).
If the button is released after the light has flashed: ON
one time - the new auto close time will be 2 seconds
two times - the new auto close time will be 30 seconds 1 2 3

three times - the new auto close time will be 1 minute CODE MODE
four times - the new auto close time will be 1 minute, TOTAL OPERATING TIME
BUT if the garage door is completely open and
a vehicle or person passes through the photocell area, This time is set to 5 minutes. No other setting is
the garage door will close immediately necessary since when the motor stops through its own
(ignoring the auto close time). limit switches, the board “senses” it and the
relay is deactivated. If however, the running time
must be adjusted, the following actions must be taken:
AUTO Move the garage door all the way open/closed.
FUSE

SYR-790-A
PWR
Set microswitch( 1 ) and press the remote control
PROGRAMMING CODES or the button to get the door sliding. The indication
light will go on and the door will start sliding.
The system will “LEARN” up to 15 different codes POWER It can either be stopped at any desired point or let
(or 15 remote controls with a different code each).

PHOTO TEST
it slide all the way. The running time
By pressing the LEARN button and a button from the remote WILL NOW BE STORED in memory.
at the same time, the new code is stored. CAUTION ! :
To clear ALL codes, short circuit the two jumpers (CLEAR) The indication light will remain on and the system
for 2 seconds using a small screwdriver. will accept no further command.
The indication light (LED) will either light on or To resume normal operation move microswitch (1)
flash on and off each time one of the 24V
to the OFF position.
actions mentioned above takes place.

COM

OPEN
OPEN

230V
LIGHT
CLOSE
PHOTO
START

230V
ANT ENN A
ADJUSTING MOTOR FORCE 230V
The preferred motor operating force BUTTON
can be set by using a small screwdriver (unlimited cable length) BE L
on the POWER adjuster. COMMON
ASE U
PLE CAREF ING
(COM) Y IR
LIMIT VER THE W
MOTOR OPEN SWITCHES H
WIT
SLIDING GATE ELECTRONIC
CONTROL PANEL SYR-790-A

SHUT
CONDENSER

E 24V contains a resettable fuse for 24V


AT Command * The system
GG (In the case of a short circuit at 24V,
I N E L the power supply is cut off and will be restored
ID LIGHT when the short circuit disappears)
S L PA N or
230V FLASHING LIGHT Photocells * The FLASHING LIGHT may light up
Light (load) connection continuously (NOT flash on and off)
up to 200W (230V) (this would be useful if a flashing light unit
(remove the with an electronic circuit board is used).
short circuit and In this case, a wire up must be done
connect as shown
FHW 58
FHW 58

to the circuit board.


TX in this figure) RX