Control Devices For Particulate Contaminants
Control Devices For Particulate Contaminants
This device consists of huge rectangular chambers. The gas stream polluted with particulates
is allowed to enter from one end. The horizontal velocity of the gas stream is kept low (less
than 0.3 m/s) in order to give sufficient time for the particles to settle by gravity.
ADVERTISEMENTS:
The particulates having higher density obey Stoke’s law and settle at the bottom of the
chamber from where they are removed ultimately. The several horizontal shelves or trays
improve the collection efficiency by shortening the settling path of the particles.
A simple cyclone separator (Fig 5.2) consists of a cylinder with a conical base. A tangential
inlet discharging near the top and an outlet for discharging the particulates is present at the
base of the cone.
Mechanism of Action:
The dust laden gas enters tangentially, receives a rotating motion and generates a centrifugal
force due to which the particulates are thrown to the cyclone walls as the gas spirals upwards
inside the cone (i.e. flow reverses to form an inner vortex which leaves flow through the
outlet). The particulates slide down the .walls of the cone and are discharged from the outlet.
In a fabric filter system, a stream of the polluted gas is made to pass through a fabric that
filters out the particulate pollutant and allows the clear gas to pass through. The particulate
matter is left in the form of a thin dust mat on the insides of the bag. This dust mat acts as a
filtering medium for further removal of particulates increasing the efficiency of the filter bag
to sieve more sub micron particles (0.5 µm).
A typical filter (Fig 5.3) is a tubular bag which is closed at the upper end and has a hopper
attached at the lower end to collect the particles when they are dislodged from the fabric.
Many such bags are hung in a baghouse. For efficient filtration and a longer life the filter
bags must be cleaned occasionally by a mechanical shaker to prevent too many particulate
layers from building up on the inside surfaces of the bag.
(4) Electrostatic Precipitators:
The electrostatic precipitator (Fig. 5.4) works on the principle of electrostatic precipitation
i.e. electrically charged particulates present in the polluted gas are separated from the gas
stream under the influence of the electrical field.
ADVERTISEMENTS:
(d) A weight at the bottom of the electrode wire to keep the wire in position.
Mechanism of Action:
The polluted gas enters from the bottom, flows upwards (i.e. between the high voltage wire
and grounded collecting surface). The high voltage in the wire ionises the gas. The negative
ions migrate towards the grounded surface and pass on their negative charge to the dust
particles also. Then these negatively charged dust particles are electrostatically drawn
towards the positively charged collector surface, where they finally get deposited.
ADVERTISEMENTS:
The collecting surface is rapped or vibrated to periodically remove the collected dust-
particles so that the thickness of the dust layer deposited does not exceed 6 mm, otherwise the
electrical attraction becomes weak and efficiency of the electrostatic precipitator gets
reduced.
As the electrostatic precipitation has 99 + percent efficiency and can be operated at high
temperatures (600°C) and pressure at less power requirement, therefore, it is economical and
simple to operate compared to other devices.
ADVERTISEMENTS:
Submicron particulates (size 0.5 to 5 µn) associated with smoke and fumes are very
effectively removed by the highly efficient Venturi Scrubbers. As shown in Fig 5.6 a Venturi
Scrubber has a Venturi shaped throat section. The polluted gas passes downwards through the
throat at the velocity of 60 to 180 m/sec.
A coarse water stream is injected upwards into the throat where it gets atomised (i.e. breaks
the water into droplets) due to the impact of high velocity of the gas. The liquid droplets
collide with the particulates in the polluted gas stream.
The particles get entrained in the droplets and fall down to be removed later on. Venturi
Scrubbers can also remove soluble gaseous contaminants. Due to the atomisation of water
there is proper contact between the liquid and the gas increasing the efficiency of the Venturi
Scrubber (their power cost is high because of the high inlet gas velocity).
To separate the droplets carrying the particulate matter from the gas stream, this gas-liquid
mixture in the Venturi Scrubber is then directed into a separation device such as a cyclone
separator.
The high pressure spray nozzles generate a fine spray that intercepts the small particles in the
polluted gas. The centrifugal force throws these particles towards the wall from where they
are drained downwards to the bottom of the scrubber.
This is so because dilution only dilutes the contaminants to levels at which their harmful
effects are less noticeable near their original source whereas at a considerable distance from
the source these very contaminants eventually come down in some form or another.
(d) Vegetation:
Plants contribute towards controlling air-pollution by utilizing carbon dioxide and releasing
oxygen in the process of photosynthesis. This purifies the air (removal of gaseous pollutant—
CO2) for the respiration of men and animals.
Gaseous pollutants like carbon monoxide are fixed by some plants, namely, Coleus Blumeri,
Ficus variegata and Phascolus Vulgaris. Species of Pinus, Quercus, Pyrus, Juniperus and
Vitis depollute the air by metabolising nitrogen oxides. Plenty of trees should be planted
especially around those areas which are declared as high-risk areas of pollution.
(e) Zoning:
This method of controlling air pollution can be adopted at the planning stages of the city.
Zoning advocates setting aside of separate areas for industries so that they are far removed
from the residential areas. The heavy industries should not be located too close to each other.
New industries, as far as possible, should be established away from larger cities (this will also
keep a check on increasing concentration of urban population in a few larger cities only) and
the locational decisions of large industries should be guided by regional planning. The
industrial estate of Bangalore is divided into three zones namely light, medium and large
industries. In Bangalore and Delhi very large industries are not permitted.