Technical Specifications
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid
the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other
trademarks may be trademarks of their respective owners.
Contents
Contents 3
1
Technical specifications
The technical and environmental specifications of your system are outlined in this section.
Topics:
• Chassis dimensions
• System weight
• Processor specifications
• PSU specifications
• Supported operating systems
• Cooling fans specifications
• System battery specifications
• Expansion card riser specifications
• Memory specifications
• Storage controller specifications
• Drives
• Ports and connectors specifications
• Video specifications
• Environmental specifications
4 Technical specifications
Chassis dimensions
8 x 2.5-inch 482 434 mm 42.8 22 mm (0.866 inches) 627.03 mm (24.686 inches) 662.19 mm
mm (17.08 mm(1.68 without bezel (26.070 inches)
(Ear to PSU surface)
(18.976 inches) 5
35.84 mm (1.41 inches) with (Ear to PSU
inches) inches) 640.3 mm (25.209 inches)
bezel handle without
(Ear to butterfly L bracket velcro strap)
housing)
NOTE: Zb is the nominal rear wall external surface where the system board I/O connectors reside.
Technical specifications 5
System weight
Table 2. PowerEdge R450 system weight
System configuration Maximum weight (with all drives/SSDs/bezel)
4 x 3.5-inch system 18.62 kg (41.05 pound)
8 x 2.5-inch system 16.58 kg (36.55 pound)
Processor specifications
Table 3. PowerEdge R450 processor specifications
Supported processor Number of processors supported
3 rd Generation Intel Xeon Scalable processors with up to 24 Up to two
cores
PSU specifications
The PowerEdge R450 system supports up to two AC or DC power supply units (PSUs).
NOTE: This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240
V.
NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system
power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
6 Technical specifications
● Microsoft Windows Server with Hyper-V
● Red Hat Enterprise Linux
● SUSE Linux Enterprise Server
● VMware ESXi
For more information, go to www.dell.com/ossupport.
NOTE: For more information about the fan support configuration or matrix, see Thermal restriction matrix.
Standard
STD STD No label
fan
High NOTE: New cooling fans comes with the High Performance
performan Silver Grade label. While the older cooling fans has the High
HPR (SLVR) HPR Silver
ce (Silver
Performance label.
grade) fan
Technical specifications 7
Table 5. PowerEdge R450 cooling fan specifications (continued)
Fan type Abbreviation Also known Label Label image
as color
NOTE: For information on the expansion card installation guidelines, see the system specific Installation and Service
Manual available at https://www.dell.com/poweredgemanuals.
Memory specifications
The PowerEdge R450 system supports the following memory specifications for optimized operation.
8 Technical specifications
Table 7. Memory specifications
Single processor Dual processors
DIMM Minimum
DIMM type DIMM rank Minimum DIMM Maximum DIMM Maximum DIMM
capacity DIMM
capacity capacity capacity
capacity
Single rank 8 GB 8 GB 64 GB 16 GB 128 GB
16 GB 16 GB 128 GB 32 GB 256 GB
RDIMM
Dual rank 32 GB 32 GB 256 GB 64 GB 512 GB
64 GB 64 GB 512 GB 128 GB 1 TB
Drives
The PowerEdge R450 system supports:
● 4 x 3.5-inch Chip SATA (HDD/SSD) drives.
● 4 x 3.5-inch hot-swappable SAS, SATA (HDD/SSD) drives.
● 8 x 2.5-inch SAS, SATA (HDD/SSD) drives.
Technical specifications 9
Table 10. PowerEdge R450 USB ports specifications (continued)
Front Rear Internal (Optional)
USB port type No. of ports USB port type No. of ports USB port type No. of ports
Micro-USB 2.0- One USB 3.0- One
compliant port for compliant port
iDRAC Direct
NOTE: The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
IDSDM
The PowerEdge R450 system supports Internal Dual SD module (IDSDM).
The IDSDM supports two SD cards and is available in the following configurations:
NOTE: Use Dell EMC branded SD cards that are associated with the IDSDM configured systems.
Video specifications
The PowerEdge R450 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
10 Technical specifications
Table 13. Supported video resolution options for the system
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32
Environmental specifications
NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located
with the Documentation > Regulatory Information on www.dell.com/support/home.
Technical specifications 11
Table 17. Maximum shock pulse specifications
Maximum shock pulse Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y,
and z axis of 6 G for up to 11 ms
Storage Six consecutively executed shock pulses in the positive and negative x, y,
and z axis (one pulse on each side of the system) of 71 G for up to 2 ms
Conductive dust Air must be free of conductive dust, zinc whiskers, or other
conductive particles.
NOTE: This condition applies to data center and non-data
center environments.
Thermal restrictions
Table 20. Thermal restriction matrix for processor and fans
Configuration / 4 x 3.5-inch configuration 8 x 2.5-inch SAS/SATA Maximum Ambient
Processor TDP configuration Temperature
Rear Storage Rear 3 LP Rear 3 LP N/A
105 W STD fan STD fan 40°C
12 Technical specifications
Table 20. Thermal restriction matrix for processor and fans (continued)
Configuration / 4 x 3.5-inch configuration 8 x 2.5-inch SAS/SATA Maximum Ambient
Processor TDP configuration Temperature
165 W 8 cores, 3.6 GHz HPR (SLVR) fan HPR (SLVR) fan 35°C
HPR HSK HPR HSK
Technical specifications 13
Table 22. Thermal restriction matrix for ASHRAE A2, A3 and A4
Dell EMC PowerEdge Server Standard Operating Dell EMC PowerEdge Server Dell EMC PowerEdge
Support (ASHRAE A2 compliant) Extended Inletient 40 ° C Server Extended
NOTE: All options supported unless otherwise noted. Operating Support (ASHRAE A3 Inletient 45 ° C
compliant) Operating Support
(ASHRAE A4 compliant)
○ Solarflare Medford2 DP 25 GbE SFP28 in 8x2.5- ● Two PSUs are required. System
inch SAS/SATA configuration. performance may be reduced in the
○ Broadcom 100 G 2P QSF in both configurations. event of a PSU failure.
○ Mellanox CX6 DP 25 G SFP28 in both
configurations.
● The following PCIe NIC only support optic cable with
thermal spec 85°C and power <= 2.5 W
○ Mellanox CX6 DP 100 GbE in both configurations
○ Intel Columbiaville 100 G 2P Q28 in both
configurations
● PCIe SSD: Intel P4800X 750 G and 375 G are only
supported in PCIe slot2 and PCIe slot3 in 4x3.5-inch
configuration. No restriction in 8x2.5-inch SAS/SATA
configuration.
14 Technical specifications