0% found this document useful (0 votes)
108 views12 pages

95AF Technical Specifications

This document provides specifications for 95AF gas furnaces with input rates ranging from 44,000 to 110,000 Btuh. Key details include a 95% AFUE rating, aluminized steel or stainless steel heat exchangers, adjustable temperature rise, and PSC blower motors. Models are available in upflow/horizontal or counterflow configurations with venting and cooling options. An extensive list of accessories is also provided.

Uploaded by

Ian Osorio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
108 views12 pages

95AF Technical Specifications

This document provides specifications for 95AF gas furnaces with input rates ranging from 44,000 to 110,000 Btuh. Key details include a 95% AFUE rating, aluminized steel or stainless steel heat exchangers, adjustable temperature rise, and PSC blower motors. Models are available in upflow/horizontal or counterflow configurations with venting and cooling options. An extensive list of accessories is also provided.

Uploaded by

Ian Osorio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Gas Furnaces

95AF
PRODUCT SPECIFICATIONS

95% AFUE
44,000 to 110,000 Btuh Input
2 to 5 Tons Add-On Cooling
INSTALLATION OPTIONS
• Available in Upflow/Horizontal
and Counterflow models

HEAT EXCHANGER
• Aluminized steel tapered design
primary heat exchanger with crimped
construction for long life
Upflow /
• Stainless steel secondary heat exchanger
Horizontal
• Flue Condensate Trap furnished

BURNERS
• Aluminized steel inshot burners
for smooth combustion

CABINET CONSTRUCTION
• Unitized construction for cabinet integrity
• Bottom or side return air
• Baked on pre-painted steel cabinet finish
• Left or right side gas and electric entry

BLOWER
• Easily removable slide-out blower design
• PSC multi-speed permanently
lubricated blower motor for low Counterflow
maintenance and optimum efficiency

CONTROLS
• Single stage gas valve
• Integrated ignition and fan control
board features self diagnostics
• Hot surface ignitor

VENTING
• One or two pipe venting ready

Warranty
Heat Exchanger - 20 Year Limited
Parts - 5 Year Limited
Gas Furnaces
95AF
Model Number Identification
95 AF 1 UH 045 P 08 B
95 = AFUE Cabinet Width
B = 17-1/2 in.
AF = Aire-Flo C = 21 in
1 = 1-Stage
UH = Upflow / Horizontal Nominal Airflow
DF = Counterflow 08 = 800 cfm
12 = 1200 cfm
Heat Input 16 = 1600 cfm
045 = 45,000 Btuh 20 = 2000 cfm
070 = 70,000 Btuh
090 = 90,000 Btuh
110 = 110,000 Btuh P = PSC Direct Drive Blower Motor

Specifications
95AF1UH045P08B 95AF1UH070P12B 95AF1UH090P12C 95AF1UH090P16C 95AF1UH110P20C
Model No.
Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Upflow / Horiz.
Input Btuh 44,000 66,000 88,000 88,000 110,000
Output Btuh 41,000 64,000 85,000 85,000 106,000
AFUE (Isolated Comb. System) 95.0% 95.0% 95.0% 95.0% 95.0%
Temperature Rise (°F) 40 - 70 40 - 70 50 - 80 40 - 70 40 - 70
Gas Pipe Size (in.) 1/2 1/2 1/2 1/2 1/2
Inlet/Vent Connection in. (diameter) 2 2 2 2 2
Condensate Drain Trap (PVC) - i.d. 3/4 3/4 3/4 3/4 3/4
Volts/Hertz/Phase 120/60/1 120/60/1 120/60/1 120/60/1 120/60/1
Blower Motor Horsepower 1/5 1/3 1/3 1/2 1
Add-On Cooling (tons) 2-2.5 2-3 2-3 3-4 4-5
Circuit Breaker or Fuse 12 12 12 12 15
Full Load Amps 3.1 6.1 6.1 8.2 11.5
Blower Wheel Size (Dia. x Width) 10 x 8 10 x 8 10 x 8 10 x 10 11 ½ x 10
Shipping Weight (lbs.) 119 129 144 154 164

95AF1DF045P12B 95AF1DF070P12B 95AF1DF090P20C


Model No.
Counterflow Counterflow Counterflow
Input Btuh 44,000 66,000 88,000
Output Btuh 43,000 64,000 86,000
AFUE (Isolated Comb. System) 95.0% 95.0% 95.0%
Temperature Rise (°F) 25 - 55 50 - 80 40 - 70
Gas Pipe Size (in.) 1/2 1/2 1/2
Inlet/Vent Connection in. (diameter) 2 2 2
Condensate Drain Trap (PVC) - i.d. 3/4 3/4 3/4
Volts/Hertz/Phase 120/60/1 120/60/1 120/60/1
Blower Motor Horsepower 1/3 1/3 1/2
Add-On Cooling (tons) 3 3 4
Circuit Breaker or Fuse 15 15 15
Full Load Amps 6.1 6.1 8.2
Blower Wheel Size (Dia. x Width) 10 x 8 10 x 8 10 x 10
Shipping Weight (lbs.) 121 134 154
Gas Furnaces
95AF
Accessories
95AF1UH090P12C
95AF1UH045P08B 95AF1DF045P12B
95AF1UH090P16C 95AF1DF090P20C
Model No. 95AF1UH070P12B 95AF1DF070P12B
95AF1UH110P20C
Upflow / Horiz. Upflow / Horiz. Counterflow Counterflow
CABINET
Combustible Flooring Base (Counterflow) --- --- 11M60 11M61
Horizontal Suspension Kit (Horizontal) 51W10 51W10 --- ---
Return Air Base (Upflow) 50W98 50W99 --- ---
DRAIN KIT
Condensate Drain Heat Cable 6 ft. 26K68 26K68 26K68 26K68
24 ft. 26K69 26K69 26K69 26K69
50 ft. 26K70 26K70 26K70 26K70
Heat Cable Tape Fiberglass ½ in. x 66 ft. 36G53 36G53 36G53 36G53
Alum. Foil 2 in. x 60 ft. 16P89 16P89 16P89 16P89
Crawlspace Vent Drain Kit 51W18 51W18 51W18 51W18
FILTER KITS
1
Air Filter and Horizontal (end) 87L96 (18 x 25 x 1) 87L97 (20 x 25 x 1) --- ---
Rack Kit (Upflow/ Side Single 44J22 44J22 --- ---
Horizontal Return 10-pack 66K63 66K63 --- ---
(Upflow) Size 16 x 25 x 1 16 x 25 x 1 --- ---
1
Air Filter and Rack Kit (Counterflow) --- --- 51W07 (2) 20 x 20 x 1 51W08 (2) 20 x 20 x 1
GAS HEATING
Natural to LP Conversion Kit 0-7500 ft. 69W73 69W73 69W73 69W73
LP to Natural Conversion Kit 0-7500 ft. 73W81 73W81 73W81 73W81
High Altitude Pressure No change (045) 93W92 (090) No change (045)
4501-7500 ft. 93W92 (090)
Switch Kit 93W93 (070) 93W93 (110) 93W93 (070)
93W87 (045) 93W87 (045)
7501-10,000 ft. 93W86 93W86
93W86 (070) 93W86 (070)
Natural Gas High Altitude
7501-10,000 ft. 73W37 73W37 73W37 73W37
Orifice Kit
LP High Altitude Orifice Kit 7501-10,000 ft. 68W68 68W68 68W68 68W68
2
36K Derate Kit (Natural Gas) 0-10,000 ft. 10K55 (045) --- 10K55 (045) ---
NIGHT SERVICE KIT
Night Service Kit 68W80 68W80 68W80 68W80
VENTING
Concentric Vent Kit 2 in. (US) 71M80 69M29 71M80 69M29
3 in. (US) --- 60L46 --- 60L46
2 in. (Canada) 44W92 44W92 44W92 44W92
3 in. (Canada) --- 44W93 --- 44W93
Flush Mount 2, 2-1/2 or 3 in. (US) 51W11 51W11 51W11 51W11
2, 2-1/2 or 3 in. (Canada) 51W12 51W12 51W12 51W12
Wall - Close 2 in. (US) 22G44 --- 22G44 ---
Couple 3 in. (US) 44J40 44J40 44J40 44J40
Wall - Close 2 in. (Canada) 30G28 --- 30G28 ---
Couple WTK 3 in. (Canada) 81J20 81J20 81J20 81J20
Roof 2 in. 15F75 15F75 15F75 15F75
Wall Ring Kit 2 in. 15F74 3
15F74 15F74 3
15F74
3
Flashing Kit 2 in. 44J41 44J41 44J41 44J41
1
Cleanable polyurethane frame type filter.
2
NOTE - 36K Derate Kit information - Reduced Input is 36,000 Btuh, output is 34,200 Btuh.
3
Kits contain enough parts for two, non-direct vent installations.
4
Non-direct vent only.
NOTE - Termination Kits 44W92, 44W93, 30G28, 51W12, 81J20 are certified to ULC S636 standard for use in Canada only.
Gas Furnaces
95AF

Blower Data
Blower 1
CFM @ External Static Pressure - in w.c. Less Filter
Model No.
Speed .00 .10 .20 .30 .40 .50 .60 .70 .80 .90
High 1140 1135 1125 1090 1065 1020 945 910 790 735
95AF1UH045P08B Med/High 920 900 895 870 870 825 780 740 670 575
(Upflow / Horizontal) Med/Low 765 765 755 725 715 675 640 585 510 460
Low 710 690 680 660 635 605 555 505 455 390
High 1585 1560 1515 1465 1410 1345 1275 1195 1105 985
95AF1UH070P12B Med/High 1340 1320 1300 1275 1235 1195 1140 1090 995 890
(Upflow / Horizontal) Med/Low 1095 1085 1080 1065 1050 1020 975 930 850 770
Low 880 885 880 890 875 840 830 780 730 650
High 1630 1615 1580 1525 1480 1415 1350 1260 1190 1060
95AF1UH090P12C Med/High 1345 1320 1305 1295 1275 1220 1175 1115 1010 930
(Upflow / Horizontal) Med/Low 1090 1070 1070 1060 1055 1030 1005 955 880 795
Low 885 890 890 890 885 860 835 785 740 655
High 2140 2110 2060 1990 1925 1830 1720 1600 1455 1300
95AF1UH090P16C Med/High 1895 1880 1835 1805 1755 1680 1610 1525 1410 1305
(Upflow / Horizontal) Med/Low 1590 1585 1580 1550 1510 1455 1390 1300 1195 1100
Low 1350 1360 1360 1365 1330 1285 1230 1165 1035 900
95AF1UH110P20C High 2400 2370 2320 2235 2165 2040 1960 1865 1715 1630
(Upflow / Horizontal)
Single Side Return Air - Air Med/High 2100 2090 2060 2040 1975 1920 1845 1750 1590 1490
volumes in bold require
field fabricated transition to
Med/Low 1755 1735 1720 1725 1700 1700 1635 1575 1505 1460
accommodate 20 x 25 x 1 in.
air filter in order to maintain
Low 1320 1330 1340 1350 1330 1325 1340 1295 1280 1235
proper air velocity.
Bottom Return Air, Side Return High 2485 2460 2405 2335 2215 2185 2060 1945 1845 1730
Air with Optional Return Air Med/High 2090 2075 2040 1990 1935 1865 1805 1700 1605 1570
Base, Return Air from Both
Sides or Return Air from Med/Low 1835 1810 1790 1760 1740 1680 1630 1605 1505 1470
Bottom and One Side. Low 1380 1390 1405 1460 1410 1410 1405 1380 1305 1250
High 1615 1605 1500 1450 1350 1300 1195 1140 1025 945
95AF1DF045P12B Med/High 1385 1380 1345 1290 1235 1170 1095 1020 920 800
(Counterflow)
Med/Low 1205 1195 1165 1125 1090 1035 990 895 840 700
Low 1045 1035 1015 975 920 880 840 780 695 605
High 1515 1490 1445 1380 1315 1270 1155 1075 975 900
95AF1DF070P12B Med/High 1315 1300 1275 1240 1190 1145 1075 1000 900 800
(Counterflow) Med/Low 1095 1075 1065 1060 1020 995 940 875 800 675
Low 910 890 910 900 875 870 820 765 715 615
High 2305 2295 2200 2160 2055 1970 1890 1775 1690 1580
95AF1DF090P20C Med/High 2145 2135 2085 1990 1935 1855 1765 1680 1590 1485
(Counterflow) Med/Low 1900 1885 1865 1830 1790 1705 1635 1565 1485 1405
Low 1515 1500 1525 1545 1530 1500 1495 1430 1370 1270
Notes:
1
Maximum approved external static pressure is 0.50 in. w.c.
Gas Furnaces
95AF

Clearance to Combustibles (in.)


Sides 1
0
Rear 0
Top/Plenum 1
Front 0
Front (service/alcove) 24
Floor 2
Combustible
NOTE − Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-Z223.1)
or the National Standard of Canada CAN/CSA-B149.1 Natural Gas and Propane Installation Code”.
NOTE − In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/
ANSI-Z223.1) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods
outlined in National Standard of Canada CAN/CSA-B149.1.
1
Allow proper clearances to accommodate condensate trap and vent pipe installation.
2
Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring.
Gas Furnaces
95AF
Vent Lengths - Feet - Upflow / Horizontal
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size.
STANDARD TERMINATION AT ELEVATION 0 - 4500 ft.
Pipe Size 2 in. 2-1/2 in. 3 in.
Input 045 070 090 110 045 070 090 110 045 070 090 110
1 76 61 39 19 110 95 63 38 132 132 113 113
2 71 56 34 14 105 90 58 33 127 127 108 108
3 66 51 29 N/A 100 85 53 28 122 122 103 103
No. of 4 61 46 24 N/A 95 80 48 23 117 117 98 98
90° 5 56 41 19 N/A 90 75 43 18 112 112 93 93
elbows 6 51 36 14 N/A 85 70 38 13 107 107 88 88
used 7 46 31 N/A N/A 80 65 33 N/A 102 102 83 83
8 41 26 N/A N/A 75 60 28 N/A 97 97 78 78
9 36 21 N/A N/A 70 55 23 N/A 92 92 73 73
10 31 16 N/A N/A 65 50 18 N/A 87 87 68 68
STANDARD TERMINATION AT ELEVATION 4501 - 10,00 ft.
Pipe Size 2 in. 2-1/2 in. 3 in.
Input 045 070 090 110 045 070 090 110 045 070 090 110
1 76 61 39 N/A 110 95 63 38 132 132 113 113
2 71 56 34 N/A 105 90 58 33 127 127 108 108
3 66 51 29 N/A 100 85 53 28 122 122 103 103
No. of 4 61 46 24 N/A 95 80 48 23 117 117 98 98
90° 5 56 41 19 N/A 90 75 43 18 112 112 93 93
elbows 6 51 36 14 N/A 85 70 38 13 107 107 88 88
used 7 46 31 N/A N/A 80 65 33 N/A 102 102 83 83
8 41 26 N/A N/A 75 60 28 N/A 97 97 78 78
9 36 21 N/A N/A 70 55 23 N/A 92 92 73 73
10 31 16 N/A N/A 65 50 18 N/A 87 87 68 68
CONCENTRIC TERMINATION ELEVATION 0 - 4500 ft.
Pipe Size 2 in. 2-1/2 in. 3 in.
Input 045 070 090 110 045 070 090 110 045 070 090 110
1 68 53 37 17 100 85 59 34 116 116 109 109
2 63 48 32 12 95 80 54 29 111 111 104 104
3 58 43 27 N/A 90 75 49 24 106 106 99 99
No. of 4 53 38 22 N/A 85 70 44 19 101 101 94 94
90° 5 48 33 17 N/A 80 65 39 14 96 96 89 89
elbows 6 43 28 12 N/A 75 60 34 N/A 91 91 84 84
used 7 38 23 N/A N/A 70 55 29 N/A 86 86 79 79
8 33 18 N/A N/A 65 50 24 N/A 81 81 74 74
9 28 13 N/A N/A 60 45 19 N/A 76 76 69 69
10 23 N/A N/A N/A 55 40 14 N/A 71 71 64 64
CONCENTRIC TERMINATION ELEVATION 4500 - 10,000 ft.
Pipe Size 2 in. 2-1/2 in. 3 in.
Input 045 070 090 110 045 070 090 110 045 070 090 110
1 68 53 37 N/A 100 85 59 34 116 116 109 109
2 63 48 32 N/A 95 80 54 29 111 111 104 104
3 58 43 27 N/A 90 75 49 24 106 106 99 99
No. of 4 53 38 22 N/A 85 70 44 19 101 101 94 94
90° 5 48 33 17 N/A 80 65 39 14 96 96 89 89
elbows 6 43 28 12 N/A 75 60 34 N/A 91 91 84 84
used 7 38 23 N/A N/A 70 55 29 N/A 86 86 79 79
8 33 18 N/A N/A 65 50 24 N/A 81 81 74 74
9 28 13 N/A N/A 60 45 19 N/A 76 76 69 69
10 23 N/A N/A N/A 55 40 14 N/A 71 71 64 64
Gas Furnaces
95AF
Vent Lengths - Feet - Counterflow
NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size.
STANDARD TERMINATION AT ELEVATION 0 - 10,000 ft.
Pipe Size 2 in. 2-1/2 in. 3 in.
Input 045 070 090 110 045 070 090 110 045 070 090 110
1 56 41 19 N/A 95 75 38 N/A 122 122 103 103
2 51 36 14 N/A 90 70 33 N/A 117 117 98 98
3 46 31 N/A N/A 85 65 28 N/A 112 112 93 93
No. of 4 41 26 N/A N/A 80 60 23 N/A 107 107 88 88
90° 5 36 21 N/A N/A 75 55 18 N/A 102 102 83 83
elbows 6 31 16 N/A N/A 70 50 13 N/A 97 97 78 78
used 7 26 11 N/A N/A 65 45 N/A N/A 92 92 73 73
8 21 N/A N/A N/A 60 40 N/A N/A 87 87 68 68
9 16 N/A N/A N/A 55 35 N/A N/A 82 82 63 63
10 11 N/A N/A N/A 50 30 N/A N/A 77 77 58 58
CONCENTRIC TERMINATION ELEVATION 0 - 10,000 ft.
Pipe Size 2 in. 2-1/2 in. 3 in.
Input 045 070 090 110 045 070 090 110 045 070 090 110
1 48 33 17 N/A 85 65 34 N/A 106 106 99 99
2 43 28 12 N/A 80 60 29 N/A 101 101 94 94
3 38 23 N/A N/A 75 55 24 N/A 96 96 89 89
No. of 4 33 18 N/A N/A 70 50 19 N/A 91 91 84 84
90° 5 28 13 N/A N/A 65 45 14 N/A 86 86 79 79
elbows 6 23 N/A N/A N/A 60 40 N/A N/A 81 81 74 74
used 7 18 N/A N/A N/A 55 35 N/A N/A 76 76 69 69
8 13 N/A N/A N/A 50 30 N/A N/A 71 71 64 64
9 N/A N/A N/A N/A 45 25 N/A N/A 66 66 59 59
10 N/A N/A N/A N/A 40 20 N/A N/A 61 61 54 54
Gas Furnaces
95AF

Dimensions - inches (mm) Upflow


1
NOTE - 20C size units that require air volumes
over 1800 cfm must have one of the following: 3-3/8 EXHAUST AIR
(86) OUTLET
1. Single side return air with transition, to accommodate
20 x 25 x 1 in. cleanable air filter.
2 (51)
Required to maintain proper air velocity.
2. Single side return air with Optional Return Air Base
3. Bottom return air.
4. Return air from both sides. D
5. Bottom and one side return air. SUPPLY AIR
See Blower Performance Tables for additional information. OPENING
2 Optional Side Return Air Filter Kit is not for use 2-7/8
with the Optional Return Air Base. COMBUSTION (73)
AIR INTAKE

Flue Condensate Trap Assembly 2 OPTIONAL


Furnished for external 7 SIDE RETURN 23-3/4
(603)
field installation (178) AIR FILTER KIT
on either side of unit. (Either Side) 25
(635)
(See installation instructions
for additional TOP VIEW
information.)

3/4 (19) 27-3/4


A Front Panel (705)
19-7/16 9/16
B 9/16 (14) (494) (14)

6-9/16 (167) 2 (51)


Left
9 (229) (Either Side)
2 OPTIONAL
Right GAS PIPING INLET
SIDE RETURN 12-5/8 (321) (Either Side)
AIR FILTER KIT (Either Side) CONDENSATE
(Either Side) TRAP CONNECTION
33 (Either Side)
(838)
6-1/2 (165)
ELECTRICAL (Either Side)
INLET
(Either Side)
23 1-1/2
14-3/4 (584) (38)
(375)
1 Side Return 14
16 Air Opening (356)
(406) (Either Side)
AIR FLOW
1-15/16 (49)
5/8
3/4 3/4 (16) 3-1/4 23-1/2
(19) C (19) (83) (597)
1 Bottom Return 1 Bottom Return
Air Opening Air Opening

FRONT VIEW SIDE VIEW

A B C D
Model No.
in. mm in. mm in. mm in. mm
95AF1UH045P08B
17-1/2 446 16-3/8 416 16 406 7-5/8 194
95AF1UH070P12B
95AF1UH090P12C
95AF1UH090P16C 21 533 19-7/8 505 19-1/2 495 9-3/8 238
95AF1UH110P20C
Gas Furnaces
95AF

Dimensions - inches (mm) Horizontal


LEFT-HAND AIR DISCHARGE

CONDENSATE
TRAP CONNECTION
12-5/8 (321) (Bottom)
Bottom
AIR
6-9/16 (167) Top FLOW
ELECTRICAL INLET
9 (229) Bottom (Top or Bottom)

6-1/2 (165)
Bottom

2 (51) GAS PIPING INLET


3/4 Top or Bottom TOP VIEW
(19) (Top or Bottom)
27-3/4 33 3/4 27-3/4
9/16 (705) COMBUSTION (838) (19) 3/4 (705)
(14) AIR INTAKE (19)
2-7/8
9/16 19-7/16 3-1/4 23-1/2
(73)
(14) (494) (95) (591)
AIR
B SUPPLY A FLOW A C RETURN
AIR D AIR
OPENING OPENING

EXHAUST AIR 2 (51)


OUTLET FRONT VIEW
3-3/8 (86) END VIEW
END VIEW RIGHT-HAND AIR DISCHARGE

CONDENSATE
TRAP CONNECTION
(Bottom)
AIR 12-5/8 (321)
FLOW Bottom
6-1/2 (165)
Bottom 9 (229) Top
6-9/16 (167) Bottom
3/4 (19)
Front Panel 2 (51)
Top or Bottom

ELECTRICAL INLET GAS PIPING INLET


(Top or Bottom) (Top or Bottom)
TOP VIEW
3/4
EXHAUST AIR (19) 27-3/4
27-3/4 3/4 33 OUTLET
(705) (19) (838) (705)
2 (51) 3-3/8
(86)

23-1/2 3-1/4 19-7/16


(591) (95) D (494)
AIR 9/16
RETURN C A FLOW A SUPPLY B (14)
AIR 2-7/8 AIR
OPENING (73) OPENING

3/4 9/16
END VIEW (19) FRONT VIEW COMBUSTION END VIEW (14)
AIR INTAKE

A B C D
Model No.
in. mm in. mm in. mm in. mm
95AF1UH045P08B
17-1/2 446 16-3/8 416 16 406 7-5/8 194
95AF1UH070P12B
95AF1UH090P12C
95AF1UH090P16C 21 533 19-7/8 505 19-1/2 495 9-3/8 238
95AF1UH110P20C
Gas Furnaces
95AF

Dimensions - in. (mm) Counterflow


9/16
(14)

Flue Condensate Trap Assembly COMBUSTION


Furnished for external 7 AIR INTAKE
field installation (178) RETURN AIR
on either side of unit. B
EXHAUST AIR OPENING
(See installation instructions OUTLET
for additional
information.)
2-1/16 (52)
2-1/4 9/16
(57) (14)
5
(127)
TOP VIEW

A 3/4 (19) 27-3/4


Front Panel (705)
9/16 19-7/16 9/16
B (14) (494) (14)
AIR FLOW

ELECTRICAL INLET
(Either Side)
2 (51)
33 Either Side
(838)
GAS PIPING INLET CONDENSATE
(Either Side) TRAP CONNECTION
(Either Side)

9-1/8 (232) Right 9 (229)


6-9/16 (167) Left 6-7/16 (163) Either Side
Either Side

Supply 19-1/4 Supply 3/4


3/4 3/4
C (19) (489) Air (19)
(19) Air

FRONT VIEW SIDE VIEW

A B C
Model No.
in. mm in. mm in. mm
95AF1DF045P12B
17-1/2 446 16-3/8 416 16 406
95AF1DF070P12B
95AF1DF090P20C 21 533 19-7/8 505 19-1/2 495
Gas Furnaces
95AF

Revisions
Sections Description of Change
Accessories/Gas Heating Added 36K Derate Kit.

1.800.982.2333
www.aireflo-hvac.com 210598 (05/13) © Aire-Flo Heating and Cooling, 2013