Brochure HTD HTU HTX en
Brochure HTD HTU HTX en
Brochure HTD HTU HTX en
TELECOMMUNICATIONS
Our HTD, HTU and HTX series conditioners are indoor monobloc units designed for equipment
rooms and low power telecom shelters. Thanks to their three different air flow configurations, they
are suitable for installation in multiple ways. Thanks to the various configurations available, the
range is very versatile and thus suited to many system set-ups, plus the accurate thermodynamic
and air distribution design enhances energy efficiency.
Main advantages
The high temperature version with R134a refrigerant and specific condensing fan is suitable for applications where the
outside air temperature is higher than 45°C. The unit is capable of starting even in extreme conditions (60°C outdoors).
In the case of extremely cold climates (down to -40°C), a version for low outdoor temperatures is available, equipped with
silicone cables, Free-Cooling damper with own servomotor and heated with electric heating elements, dual casing heater
and electrically heated control panel.
2
HTD-HTU-HTX
Shelter safety
All models in the HTD-U-X range feature evaporating coils with hydrophilic coating.
This special coating - together with an adequate adjustment of air throughflow
speeds - helps condensate collection during the dehumidification process, avoiding
dripping on the inside and outside of the unit.
Multi-protocol communication
interface
HiRef units can be integrated with the
customer’s external supervision Building
Management System (BMS), using the
most popular communication protocols, AIR/AIR
including Modbus RTU, Modbus/IP,
BacNet, LonWorks, SNMP.
EC Radial Fans
Radial or centrifugal fans are
characterised by backward blades. Air
is taken in the axial direction, parallel to
the rotation axis and delivered radially,
perpendicular to the rotation axis. This
type of fan does not require an external
screw, has a high head and is suitable
Additional benefits
for use in indoor units where the air is • R410A refrigerant, also available with R134a and
often ducted and recirculated. They are R513a
driven by electronically commutated (EC)
• Version available with dual power supply for
brushless permanent-magnet (BLDC)
emergencies: 230/400V network and 24/48VDC
synchronous motors. The use of these
backup supply
motors reduces unit consumption, noise
and footprint, improves the efficiency and • Evaporating and condensing side fans available
life cycle of the system through accurate with EC motor
control of speed and acceleration, • Stainless steel condensate drain pan
resulting in less heat dissipation. In
• Dehumidification function
addition, inrush currents and sparks are
eliminated. • Epoxy powder painted structural metalwork
supplied as standard
3
HTD-HTU-HTX
Technical table
HTD -HTU-HTX 0451 0561 0731 0901 1051 1201 1501 1701 1801 2001 2201 2501
AIR TEMPERATURE 27°C - RELATIVE HUMIDITY 40% / OUTDOOR AIR TEMPERATURE 35°C
COOLING CAPACITY kW 4.4 6 7 10.7 10.9 12.7 15 16.4 18.4 22.1 24.9 27.6
SHR - 1 0.9 0.95 0.99 0.98 0.92 0.98 0.94 1 0.99 0.99 0.95
EER - 4.26 3.54 3.26 3.28 3.71 2.81 3.39 2.93 4.71 3.79 3.84 3.5
AIR TEMPERATURE 30°C - RELATIVE HUMIDITY 35% / OUTDOOR AIR TEMPERATURE 35°C
COOLING CAPACITY kW 4.6 6.2 7.4 11.4 11.6 13.3 15.9 17.2 19.6 23.5 26.3 28.9
EER - 4.47 3.61 3.38 3.45 3.88 2.91 3.54 3.02 4.99 3.99 4.03 3.63
Performance data relating to Downflow versions with R410A refrigerant. | Also available with 60 Hz power supply.
HiRef S.p.A. reserves the right, at any time, to introduce any necessary changes and improvements to its products without prior notice.
Reproduction, even partial, of this catalogue is forbidden without a written permission from HiRef S.p.A. © Copyright HiRef S.p.A. 2001-2022
HiRef S.p.a • Viale Spagna 31/33 35020 Tribano (PD) - IT • Tel: +39 0499588511 • Fax: +39 0499588522
[email protected] • [email protected] • CF/P.IVA: 02191431200 • REA: PD - 327685