COBUX

The document provides a front panel view of a COBUX/COBUV unit. It shows various connectors and interface modules including a Q1-unit interface, Q1-master interface, alarm interface, and synchronization interface. It also provides an architectural description, listing the functional blocks that implement the COBUX function, such as a CPU block, clock supply and synchronization, peripheral communication, routing protocols, and diagnostics.

Uploaded by

NABIL MERZOUGUI
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
128 views1 page

COBUX

The document provides a front panel view of a COBUX/COBUV unit. It shows various connectors and interface modules including a Q1-unit interface, Q1-master interface, alarm interface, and synchronization interface. It also provides an architectural description, listing the functional blocks that implement the COBUX function, such as a CPU block, clock supply and synchronization, peripheral communication, routing protocols, and diagnostics.

Uploaded by

NABIL MERZOUGUI
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

COBUX/COBUV © ABB Ltd

Figure 2: Front panel view of COBU<X> unit

Fixing screw
Pull-out handle

...............
............... Identification (HW) label
...............

Unit LED UA LED


(bicolor red-green) (red)
Optical Fault Indication
Traffic LED NA LED
(red) (yellow)

D-Sub 9-pin male connector (C3.1)


for the F-interface

RJ-45 8-contact female connector (C2.1)


for the QX-interface

DIN 41 612 connector type C,


2 x 32 contacts, male,
4 modules with coding

Q1-unit interface module (C1.4)

Q1-master interface module (C1.3)

Alarm interface module (C1.2)

Synchronisation interface module (C1.1)


- 2 x 2048 kHz clock input
- (3 + 1) x 2048 kHz clock output
Pull-out handle
Fixing screw

Architectural description
The COBU<X> function is implemented using the following functional
blocks:
CPU block with micro-controller, memory and peripheral logic
Clock supply and synchronisation (PETS)
Peripheral unit communication
DXC and Highway Access
NE Database
Unit protection control
OSPF Router (NE management communication)
IS-IS Router (NE management communication)
Metering Pulse Generator
Diagnostics

page 6 of 108 FOX Manual Units, Part 1 1KHW001447R0001