0% found this document useful (0 votes)
80 views19 pages

MCS MR Eeg

This document summarizes several neurophysiology products from Medical Computer Systems Ltd., including: 1) DC EEG amplifiers (models NVX-24, NVX-36, NVX-52) with 24, 32, or 48 channels for clinical and research use. 2) The NEUROvisor clinical EEG system which is based on the NVX amplifiers and has been developed for use in clinical settings. 3) An EP/ERP set for evoked potential and event-related potential studies, using the NVX amplifiers with higher sampling rates.

Uploaded by

Dhanush sridhar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
80 views19 pages

MCS MR Eeg

This document summarizes several neurophysiology products from Medical Computer Systems Ltd., including: 1) DC EEG amplifiers (models NVX-24, NVX-36, NVX-52) with 24, 32, or 48 channels for clinical and research use. 2) The NEUROvisor clinical EEG system which is based on the NVX amplifiers and has been developed for use in clinical settings. 3) An EP/ERP set for evoked potential and event-related potential studies, using the NVX amplifiers with higher sampling rates.

Uploaded by

Dhanush sridhar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

NEUROPHYSIOLOGY

About us 4

СONTENT DC EEG amplifiers NVX - 24/36/52 8

Clinical EEG system NEUROvisor 10

EP/ERP set 14

DC MR EEG systems NVX - 72/136/272 18

Mobile DC EEG systems NeoRec cap 22

DC EEG + tES system NVX-36T 26

Mobile tES system tES4me 30

EEG accessories MCScap 34

3
About us
Since 1993 year company Medical Computer Systems Ltd. successful design and manufacture
high-tech devices and accessories for medical and research applications.

Projects include a wide spectrum of diagnostic and therapeutic equipment:


DC EEG amplifiers for clinic and research, including Multichannel MR-compatible EEG amplifiers
and wireless EEG amplifiers, tES systems, ECG screening systems, EEG and ECG accessories, etc.
Video about us

4 5
Partners of Medical Computer Systems Ltd. are leaders of EEG equipment for scientific research
and medical world market. Company supports the international quality system ISO 9001,
ISO 13485 and manufactures many products with CE mark.

Medical Computer Systems Ltd. provides a complete engineering solution in the medical &
research devices outsourcing development and production as OEM.

Multi-disciplinary team of experienced engineering and researchers, continuous progress


in the developments and production technologies allow to stay company on top of innovation.

6 7
NVX – 24 / 36 / 52
NVX is DC amplifier with 24, 32 or 48 monopolar EEG channels and 4 auxiliary bipolar channels for sensors
NeoSens. The device is used in training systems, clinical and scientific research as a part
of computer-based research system for short-term recording of the electrophysiological signals, primarily EEG.
The amount of channels and presence of auxiliary channels depends on models.

NVX amplifiers is used with NeoRec application software. NeoRec is software for the acquisition of EEG
and other biomedical signals during the process of scientific or medical research. The program records
DC EEG the signals in various file formats for further analysis and processing by third-party software.

Supported file formats: EDF+, BDF+, GDF, Brain Vision.


24 channels
For viewing or processing the recorded data, the following third-party programs and software packages
32 channels are recommended: EEGLAB, ERPLAB, OpenViBE, BioSig.

48 channels Specification
Model NVX 24 NVX 36 NVX 52

EEG DC monopolar channels 24 32 48

AUX bipolar channels – 4 galvanically isolated from EEG for probes

TTL triggers 1 input / 1 output 9 input / 1 output

Display – Graphic OLED

EEG dynamic range ±400 mV

EEG channel’s input impedance more 100 MOhm @ DC

EEG channel’s noise less 0.9 uV p-p @ 0,1...30 Hz

EEG test signal 200 μV (±1%), 1 Hz

Electrode impedance measurement range 1...120 kOhm (±10%) @ 30 Hz

AUX channel’s dynamic range 0...+4 V

AUX channel’s input impedance more 100 MOhm @ DC

AUX channel’s noise less 15 uV p-p @ 0,1..30 Hz

AUX probe powering +5 V (±5%). Up to 15 mA per probe with electronic protection

24 bit, 6th order delta-sigma modulator with 64x oversampling,


Digitalization
one converter per each channel

250, 500, 1000, 2000 Hz @ all channels


5000 Hz @ 24 EEG monopolar or bipolar channels
Sampling rate
10000 Hz @ 16 EEG monopolar or bipolar channels
50000 Hz @ 4 EEG monopolar or bipolar channels

Lower cutoff frequency 0 Hz (DC)

75 Hz (-3dB @ 250 Hz); 175 Hz (-3dB @ 500 Hz); 300 Hz (-3dB @ 1000 Hz);
Upper cutoff freguency 500 Hz (-3dB @ 2000 Hz); 1650 Hz (-3dB @ 5000 Hz);
4900 Hz (-3dB @ 10000 Hz); 16000 Hz (-3dB @ 50000 Hz)

Control and powering from USB +5V, 450 mA

Safety IEC 60601-1, IEC 60601-2-26, class IIa, type BF

Size 155 x 110 x 45 mm


Video about
Weight less 650 gr
NVX – 52
8 9
NEUROvisor The most friendly clinical EEG system
Based on NVX amplifiers it has been developed a clinical EEG system NEUROVISOR for use in functional
diagnostics rooms, medical departments of multidisciplinary and neurological hospitals, health centers,
clinics and research institutes.

clinical
DC EEG

NVX24 NVX36 NVX52

24 EEG channels 32 EEG channels 48 EEG channels


Clinical EEG 4 AUX channels for probes 4 AUX channels for probes
OLED display OLED display
Clinical EEG Clinical EEG
EP/ERP EP/ERP

DB25 connector DB25 connector KEL50 connector


for EEG cap KEL50 connector for EEG cap
Video about for EEG cap
NeuroVisor
10 11
SOFTWARE

EEG maps in spectral bands

Digital DC EEG ampliers System includes


• Full DC channels, • EEG amplier NVX with 5m USB cable,
• 24 bit resolution, • photic stimulator with 5m USB cable,
• ±400 mV dynamic range of EEG channels, • EEG electrode cap (size 54-60 cm)
• 500 or 2000 Hz sampling rate for clinical EEG, with common connector,

• 2000, 10000 or 50000 Hz sampling rate • 2 leads ECG cable with electrodes,
for EP/ERP. • user manual,
• soft ware on USB fash.
Software advantages
PC with Windows 10 64 bit or higher is reguired
• one button solution, for installation.
EEG spectrums for each lead
• standard montages and examination scenarios
according to IFCN guidelines,
Options
• automatic or semi-automatic examination
procedure with voice prompts, • stand for amplifier,

• automatic artifact rejection using ICA method, • stand for photic stimulator,

• automatic generation of reports with manual • EP/ERP package*


editing capability. (software license, optical trigger sensor,
audio stimulator, response keyboard).

Quantitative EEG
Original probes for AUX channels*
• amplitude-frequency analysis of the main
EEG rhythms, • photoplethysmography finger probe,
• spectral analysis (charts and maps), • 3D accelerometric probe,
• independent component analysis. • breath thermometric probe,
• galvanic skin response probe.

EEG signals, video frame, automatic conclusions * Intended for NVX36 and NVX52 amplifiers only

12 13
EP / ERP set
EP/ERP set is intended for recording and analysis the potentials of the human brain, caused
by the presentation of sound or visual stimuli.

EP/ERP is used by professionals in the neuroscience, cognitive psychology, cognitive sciences,


and psychophysiological research. Module methods are well suited for studying the rate of neural activity.

In clinical research, EP/ERP is used to treat neurological conditions such as ADHD, dementia, Parkinson's
disease, multiple sclerosis, head trauma, stroke obsessive-compulsive disorder, etc.
Evoked
Potentials

Event-Related
Potentials EP/ERP set supports more than 60 different tests.

P300 VN400
ERP component ERP component
elicited in the process elicited to visual
of decision making inclusion of meaningful
words in sentence contexts

MATHEMATICS ECPT
test of brain’s reaction test to assess
in the process of solving the ability to focus
mathematical tasks on constant activity

GONOGO VCPT
test of variation of decisions test to assess
about spatial complexity the ability to focus
or functional connectivity on visual stimulus
of visual objects by EEG

VISUAL EP VCPT ERP


a flashing chessboard continuous performance test. Target
to detect damage or injury and non-target stimuli appear on the
to the visual system screen in the form of cartoon images
Video about without letters and numbers

ER/ERP
14 15
EP/ERP set provides precise positioning of the stimulus label on the EEG when recording evoked potentials.
Set is designed for use with NVX EEG amplifiers with Neurovisor software, as well as with other amplifiers
and software. Set includes an audio stimulator with the ability to synchronize event marks, headphones,
a keyboard for recording the response of the subject, and an optical sensor for synchronizing the presented
visual stimuli.

EP/ERP set connection diagram


SOFTWARE

VGASens
ER headphones

VCPT test
ER keyboard
Second monitor ER keyboard
Computer

Trigger cable

AStim audio
stimulator

NVX52
www.mks.ru

1Fp1 2Fpz 3Fp2


NVX52
4F7 5F3 6Fz 7F4 8F8

9Ft7 10Fc3 11Fcz 12Fc4 13Ft8

14T3 15C3 16Cz 17C4 18T4

19Tp7 20Cp3 21Cpz 22Cp4 23Tp8

23A1 25T5 26P3 27Pz 28P4 29T6 30A2

31P5 32Po3 33Poz 34Po4 35P6

GND 36Po7 37O1 38Oz 39O2 40Po8

41B1+ 43B2+ 45B3+ 47B4+

49Aux1 50Aux2 51Aux3 52Aux4

VN400 test
42B1- 44B2- 46B3- 48B4-

NVX 36/52

System includes
• ASTIM acoustic stimulator with 5m USB cable, EP/ERP package is an option for NEUROVISOR
• ER headphones, clinical EEG system. EEG amplier NVX36/NVX52
is not included in the EP/ERP package.
• ER keyboard,
• VGASENS optical trigger sensor, PC with Windows 10 64 bit or higher is reguired
• trigger cable for connec tion to EEG amplier NVX, for installation.

• user manual,
• software license.
P300 test

16 17
EEG for researchers
up to 272 channels
MR compatible

Uncompromising device NVX-272 DC EEG MR system includes


for EEG acquisition • NVX – 136 DC EEG system base - 2 pcs,
• Electrode cap MCScap PROFESSIONAL MR,
NVX – 72/136/272 are designed for a medical-biologic size L 54-60 cm.
researching in scientific and educational institutions.

Each channel has a direct current input and individual


NVX-136 DC EEG system base includes
24-bit analog-to-digital converter for measuring
• NVX136 DC EEG amplier,
the EEG signal up to 100 thousand times per second.
• NVX136 media converter,
Possible to extend up to 272 channels by connecting
• NVX136 battery module,
two amplifiers to the media converter, which gives
• NVX136 charger,
a single clock frequency for all ADCs and ensuring
• optical cable 1 m,
synchronous channels conversion.
• optical cable 10 m,
Software for planning of experiment and recording
• NVX136 transport suitcase.
signals to EDF+ 16bit, BDF+ 24bit, GDF 32bit.

NVX – 72 / 136 / 272


DC MR EEG
Multichannel
72 channels
136 channels
Video about
272 channels NVX – 136
18 19
Specification
Number of DC EEG channels 136

Dynamic range not less ±400 mV

Input impedance more 1 GOhm @ DC / 30pF max

EEG channels noise less 0.9 uVp-p @ 0,1..30 Hz

Voltage measurement error less ±0.5%

8 monopolar (4 connectors x 2 channels)


DC channels of number, connected via AUX or 4 bipolar (4 connectors x 1 channels)
set by application SW

Additional dynamic range for channels,


SOFTWARE

not less ±2000 mV, set by application SW


connected via AUX

24 bit, 6th order delta-sigma modulator with 64x oversampling,


Analog-to-digital conversion
one converter per each channel

For 64 EEG channels 100 000 Hz (16 000 Hz)


Sampling rate of amplifier For all channels: 50 000 Hz (16 000 Hz), 25 000 Hz (9 000 Hz),
(high cut off frequency at -3dB) 10 000 Hz (4 900 Hz), 5 000 Hz (1 600 Hz), 2 000 Hz (650Hz),
1 000 Hz (300 Hz), 500 Hz (160 Hz), 250 Hz (80 Hz)

set individually for each channel from a range of 0..100Hz


Low cutoff frequency at -3dB, set by application SW
or selected from the series 0, 0.001, 0.05, 0.1, 0.5, 1, 2, 5, 10 Hz

set individually for each channel from a range 5000..1 Hz


High cutoff frequency at -3dB, set by application SW
or selected from the series 500, 300, 100, 70, 50, 30, 20, 10, 5, 1 Hz

TTL triggers input / output 8 / 8, not galvanically isolated from PC

Electrode impedance measurement range


1..120 kOhm (±10%), at 30 Hz
(absolute error)

Test EEG signal square wave 200 uV (±1%), 1 Hz

Input for external synchronization of ADCs 5..100 MHz, 50 Ohm sin / square wave

Aux sensor powering 5V, up to 100 mA for all sensors with electronic protection

Connecting amplifier – media converter Optical plastic cable 10 m (option 20 m)

Connecting media converter – PC USB V2.0 High-speed 480 MBod

from accumulator module 6 V, 7A ·h; current consumption:


Powering of amplifier less 1400 mA for sampling rates of 25 000..100 000Hz,
less 500 mA for another sampling rates, less 3 mA in standby mode

from USB 5 V; less 400 mA in active mode,


Powering of media converter
less 5 mA in standby mode

Sizes and weight of amplier 195x140x35 mm, 1200 gr.

Sizes and weight of accumulator module 195x140x48 mm, 2500 gr.

Sizes and weight of media converter 90x112x58 mm, 300 gr.

20 21
NeoRec сap
NeoRec cap – EEG cap with 17 pre-installed Ag/AgCl sintered electrodes and 16-channel DC mobile EEG
amplifier with a built-in accelerometer.

EEG amplifier is designed to record EEG and other bioelectrical signals with wireless real-time data transfer to a PC.

NeoRecCap can be used for education, research and development in EEG, neuro-computer interfaces (brain-
computer interface, direct neural interface, brain interface), bio-feedback (BCI), neuromarketing, neurogaming,

DC EEG brain fitness.

Mobile Advantages
• 16/21 DC EEG channels for biomedical and research applications,

16 channels • 24 bit resolution,


• BLE wireless for PC and mobile application,

21 channels • lightweight and small EEG amplifier,


• 12 sizes of cap cover from 24 cm up to 66 cm of head circumference,
• quality Ag/AgCl sintered electrodes,
• wide range of EEG accessories (different types of electrodes, adapters, etc.).

SOFTWARE
NeoRec cap is intended to record EEG and 3D acceleration events
to files of different formats (EDF+ 16 bit, BDF+ 24 bit, GDF 32 bit)
or transmit it online via stream LSL (Lab Streaming Layer)
for analyze by third-party software as MATLAB / EEGLAB, OpenViBE etc.

Video about
NeoRec cap
22 23
System NeoRec cap can includes a different types Specification
of electrode caps MCScap. BASE

for using with EEG gel & solid gel

PROFESSIONAL

NeoRec cap NeoRec 21

for using with EEG gel

Model NeoRec cap NeoRec 21 NeoRec mini


DRY
DC EEG channels
16 21 21
relative to GND

Dynamic range ±150, ±300 mV ±150, ±300 mV ±150, ±300 mV

Resolution 24 bit 24 bit 24 bit

Sampling rate 125, 250, 500, 1000 Hz 125, 250, 500, 1000 Hz 125, 250, 500, 1000 Hz

Input impedance
more 1 GOhm more 1 GOhm more 1 GOhm
at DC
for using with dry SoftPulse sensors
Self-noise
2 μV p-p 2 μV p-p 2 μV p-p
@ 0.1-30Hz
Impedance 1 ..5000 kOhm 1 ..5000 kOhm
1..140 kOhm
measurement (dry electrode check) (dry electrode check)
activity (4 steps), change activity (4 steps), change activity (4 steps), change
Events
orientation, free fall, button orientation, free fall, button orientation, free fall, button
System includes Offline data
no yes, to microSD card yes, to microSD card
recording
• EEG amplifier NB2-EEG16, Active electrodes
yes yes, with digital control yes, with digital control
support
• Electrode cap PROFESSIONAL/BASE/DRY for amplifier
NB2-EEG16, size by choose, Working time more than 15 hours more than 12 hours more than 2,5 hours

• Ear electrodes PROFESSIONAL/BASE/DRY with ear fixator, Wireless interface BLE 4.2 BLE 5.2 BLE 5.2

• USB charger cable, User manual, Plastic box for storage, Wireless CE, FCC USA, Canada, Japan, CE, FCC USA, Canada, Japan, CE, FCC USA, Canada, Japan,
certification Korea, Taiwan Korea, Taiwan Korea, Taiwan
• NeoRec software for Windows 10 PC (Internet loading).
Firmware update wireless by mobile application wireless by mobile application wireless by mobile application

Size 67 x 38 x 16 mm 67 x 38 x 16 mm 33 x 23 x 18 mm

Wight 40 g 40 g 14 g

24 25
NVX – 36T
Research system for DC EEG acquisition and transcranial electrical stimulation (tDCs/tACs/tRNS)

Аdvantage
• 32 EEG DC monopolar channels, 4 DC AUX bipolar channels for probes, 9/1 input/output triggers,
OLED display, AC/DC DDS current generator. Stimulate using up to 31 electrodes.
• Dual use electrodes for EEG acquisition and stimulation. Used big-area sintered Ag/AgCl electrodes
DC EEG and innovative textile cap.

36 channels Flexible EEG acquisition and transcranial current stimulation


NVX-36T amplifier is used in training systems, clinical and scientific researches as a part of computer-based
tDCS system. Each channel has a DIRECT CURRENT input cascade and individual 24-bit ADC for EEG sampling
up to 10000 times per second. Internal high resolution Direct Digital Synthesis (DDS) current stimulator
tACS for producing DC or AC current via any EEG electrode or a set of electrodes.
Application software for settings of experiment, recording to EDF+, BDF+ and stimulation.

tRNS Software library for self-design of user application.

SOFTWARE
System includes
• NVX-36T DC EEG amplifier & tES stimulator (tDCs/tACs/tRNS),
• USB cable 5 m,
• NVX-T EXPERT software (LSL server & tES),
• NEOREC software,
• Electrode kit,
• Stand for NVX amplifier (optional).

26 27
Specification Loading an external stimulus from a specially prepared WAV file

Current generator sampling rate 8000 Hz


EEG recording mode
Maximum frequency for a periodic signal 1000 Hz
EEG monopolar channels 32
Total generator current;
Auxillary connectors for sensors; 4 galvanically isolated from EEG Total load impedance;
Measurements during stimulation
Local current for each electrode
TTL triggers (input / output) 9/1 (for all electrodes in AC mode, for the anode in DC mode)
Display OLED; 3.2», 256 x 64 px In the program, sound signal, light indicator,
Stimulation indication
output trigger, on the LED screen of the device
Dynamic range of EEG channels not less than ± 400 mV

Input impedance of EEG channels more 100 MOhm @ DC Other

Self-noise of EEG channels < 1 μV p-p (0.15 RMS) @ 0.1-30 Hz TouchProof 1.5 mm (DIN 42 802-BU) for individual electrodes
Connector for electrode cap DB-25F (24 channels)
EEG test signal square 250 μV (±1%), 1 Hz KEL 8830E-040 (32 channels)
Electrode impedance measurement range
1-120 kOhm (±10%) @ 30 Hz Control USB only
(absolute error)
PC interface USB, V1.1, 2.0, 3.0 type B, Plug And Play
Dynamic range of Aux channels 0-4 V
Сable length 5m
Input impedance of Aux channels more 100 MOhm @ DC
OS Windows 10 (64 bit)
Self-noise of Aux channels < 15 μV pk-pk (2.5 μV RMS) @ 0.1-30 Hz
5 V, 450 mA max from USB in active mode, current consump
Powering of sensors +5 V (±5%). up to 15 mA per channel with electronic protection Power
tion up to 450 mA, in standby mode up to 5 mA
24 bit, 6th order delta-sigma modulator with 64x
Digitalization Time of continuous work not less than 8 hours
oversam pling, one converter per each channel
Average lifetime 5 years
Low cutoff frequency From 0 Hz (DC) followed by filtering by application software
Dimensions (LxWxH) 200 х 155 х 40 mm
500, 1000, 2000 Hz (TETOS Expert);
250, 500, 1000, 2000, 5000, 10000 Hz (NeoRec); Net weight < 650 g
Signal sampling frequency
250-2000 Hz for all channels: 5000 Hz for the first 24 channels;
10000 Hz for the first 16 channels; IEC60601-1, IEC60601-1-6, IEC60601-2-10,
Safety
IEC60601-2-26 class II, type BF
Real time data transmission protocol Lab Steaming Layer (LSL)

Stimulation mode

Number of current generators 1


Electrode kit includes
up to 31 (30 EEG + GND, switching to channels A1 and A2
Number of stimulation channels is not available), each electrode can be connected • Ag/AgCl sintered electrodes MCScap-NTC – 33 pcs.
to the anode or cathode of the generator
• Ag/AgCl electrodes MCScap-CS22 – 33 pcs.
Current generator 16 bit Direct Digital Synthesis (DDS) • Stainless steel electrodes MCScap-CS22SS – 33 pcs.
Stimulating range from 10 μA to 3.9 mA • Set of ear Ag/AgCl sintered electrodes
Maximum output voltage of the current generator 30 V with fixators – 2 pcs.

Direct current (tDCS), Alternating current (tACS),


• Textile cap MCScap 10-10, size L (54-60 cm) – 2 pc.
Stimulation current modes Alternating current monopolar (tACMS), • Textile cap MCScap 10-10, size M (48-54 cm) – 2pc.
Random noise (tRNS), Custom stimulation mode
• Textile cap MCScap 10-10, size S (42-48 cm) – 2 pc.
Stage duration up to 60 min
• Elastic textile belt, size L (54-60 cm) – 2 pc.
Smooth start/end of stimulation Off, 10, 20, 30 sec
• Elastic textile belt, size S (42-48 cm) – 2 pc.
Off, 10 / 20 / 30 sec. at the beginning, 10 / 20 / 30 sec.
Sham stimulation • Starter kit (conductive gel, syringe, needles,
at the beginning and at the end
brushes for cleaning).
Sine, square, random noise, ramp, trap, sinc,
Stimulus shapes in tACs and tACMs mode
Gauss, Lorentz, haversine, exponential, custom

28 29
tES4me
tES4me is a personal system for transcranial electrical stimulation intended for physiotherapy and rehabilitation
of patients with neurological and psychiatric diseases by means of transcranial electrical stimulation (tES)
in accordance with stimulation protocol prescribed by the attending physician.

Weak constant or pulsating electrical stimuli from surface electrodes are delivered to the brain during tES
procedure. It is known that properly selected tES procedure improves the quality of life and corrects such
clinical conditions as anxiety, depression, insomnia, addiction and can also be used to create a state similar
8 electrodes to chemically induced anesthesia.

tES4me can be used by the patient independently at home after preliminary programming of the personal
personal stimulator by the doctor.

mobile Advantages
• Programming scenarios up 30 unique procedure, up to 5 stages in the procedure;
tDCS • From 2 up to 8 electrodes can be connected to current generator poles in arbitrary order;

tACS • Individual tES modes for each stage:


tDCS - Transcranial direct current stimulation,

tRNS toDCS - Transcranial oscillatory direct current stimulation,


tACS - Transcranial alternating current stimulation,
tPCS - Transcranial pulsed current stimulation,
tRNS - Transcranial random noise stimulation,
HD-tES - High density transcranial electrical stimulation,
Sham stimulation.

• Current generation with direct digital synthesis (DDS) up to 4 mА;

• Precise current adjustment 1 μА;

• Smooth increasing and decline of stimulation current;

• Continuous impedance measurement during TES procedure;

• Simple device operation – one button solution.

System includes
• tES4me stimulator,
• Adapter tES4me with 8 electrodes,
• textile cap MCScap light,
• Sponge D22 (50 pcs.),
• USB cable for tES4me,
• User manual,
• tES4me box.

30 31
Specification

Number of procedures in the course / stages in the procedure 1-30 / 1-5

Duration of the procedure / stage 1-60 min.

Setting of minimum rest time after the procedure.


0, 1, 6, 12, 24, 48, 72 hours
Device is blocked during this time

Smooth rise and fall of stimulation current Off, 10, 20, 30 sec.

Stimulation current 10-4 000 μА

tES modes tDCS, toDCS, tACS, tPCS, tRNS, HD-tES, Sham stimulation

Maximum allowable impedance for maximum stimulation


9.5 kΩ /38 V
current/generator voltage

DDS generator sampling frequency/digit capacity 8 kHz / 13 bit

Checking of the electrode connection before


Impedance less 8 kΩ @ 30 Hz, measurement current 30 μA
stimulation

Shape (for tACS and toDCS modes) Sine, Random, Square, Ramp, Trap, Sin(X)/X, Gauss

Frequency (for tACS and toDCS modes) 1-1 000 Hz

Lower cutoff frequency for tRNS mode @-3dB 10 Hz, 50 Hz, 100 Hz, 200 Hz, 300 Hz, 500 Hz

Upper cutoff frequency for tRNS mode @-3dB 50 Hz, 100 Hz, 200 Hz, 300 Hz, 500 Hz,1000 Hz

Wireless interface BLE 4.2

Wireless certification CE, FCC USA, Canada, Japan, Korea, Taiwan Doctor mobile application for setting up the protocol of stimulation.

Battery charging 2.5 hours from USB 5V ⎓ 2A(max)


Patient mobile application for online monitoring of stimulation procedure parameters.
Dimensions (LxWxH) 87 x 56 x 17 mm

Net weight 65 g

Operation system iOS, Android, Windows

Programming of stimulation courses and course templates,


Main functions of the doctor application uploading of protocols and condition assessments, operation
with a patient database

Schedule of procedures with mark after completion,


Main functions of the patient application assessment of the state after procedure (1-5 points),
indication of stimulation process

Diameter / surface area of electrode CS22-SS 22 mm / 3.80 cm2

Diameter / surface area of electrode CS13-SS 13 mm / 1.32 cm2

XL (60-66 cm), XL/L (57-63 cm), L (54-60 cm),


Available cap sizes L/M (51-57 cm), M (48-54 cm), M/S (45-51 cm),
S (42-48 cm), S/XS (39-45 cm), XS (36-42 cm)

Offline operation by pre-configured and loaded protocol into the internal memory of the device.

32 33
MCScap
Accessories EEG electrode caps
EEG electrode caps MCScap are ready
EEG solutions for any EEG examinations.

tES • quality of EEG signal acquisition, Textile caps for EEG electrodes
• comfortable for patient,
Textile cap MCScap is made of elastic material that provides the most
• easy and fast installation, comfortable fit of the electrodes and the right positions without additional
• сonvenience for doctor/operator, adjustment. Numerous big holes are intended for the opportunity to push
• long durability. the hair and prepare the skin for examination, and also for better ventilation.

Textile caps have a marked holes for electrodes according to international systems 10-20, 10-10, 10-5.

12 sizes of cap cover the head sizes from 24 cm to 66 cm head circumference. Color material or color seams helps
to make a quick choose of the right size.

The material does not allow the gel or paste to dry out under electrodes fast.

EEG electrodes
Reusable passive electrodes MCScap are
based on high-quality Ag/AgCl and Ag/AgCl
sintered sensors which guarantee:

• a high quality signal


• a long-term stable electrical contact
Video about
• a low noise reference electrode MCScap
• a minimum electrode polarization
• an excellent low frequency response

All MCScap electrodes can be integrated


into textile cap MCScap. Electrodes
can have TouchProof connectors
or can be preinstalled in the Electrode
cap with common connector. All electrodes
have special holes for conductive gel.

34 35
Medical Computer Systems Ltd.
Passage 4922, 4-2, Zelenograd, Moscow, 124460, Russia
Phone: +7 495 913 31 94
E-mail: [email protected]
Internet: www.mks.ru
Internet shop: www.mcscap.com

YouTube channel Brochures

You might also like