Load Cases For Transmission Tower

The document outlines load combinations for the design of DD/DDE tower types, including normal, broken wire, and erection conditions. It lists 73 load cases considering self-weight, wind loads, and different wire break scenarios for normal and erection conditions. It also references loading trees used in the design.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views8 pages

Load Cases For Transmission Tower

The document outlines load combinations for the design of DD/DDE tower types, including normal, broken wire, and erection conditions. It lists 73 load cases considering self-weight, wind loads, and different wire break scenarios for normal and erection conditions. It also references loading trees used in the design.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 8

1.

LOAD COMBINATIONS FOR DD/ DDE TOWER

Load combinations used in this design are;


SELF_WEIGHT
FULL WIND-TRANS-WL1 (from PLS-CADD)
LOADS FOR DD TYPE TOWER
NORMAL CONDITIONS (RELIABILITY REQUIREMENTS)
1. NC -VMAX Normal Load
2. NC - VMIN Normal Load
************************************
BROKEN WIRE CONDITIONS (SECURITY REQUIREMENTS)
3. BWC : E1, C1 & C3 BROKEN – V MAX
4. BWC : E1, C1 & C3 BROKEN – V MIN
5. BWC : E1, C1 & C5 BROKEN - VMAX
6. BWC : E1, C1 & C5 BROKEN - VMIN
7. BWC : E1, C3 & C5 BROKEN - VMAX
8. BWC : E1, C3 & C5 BROKEN - VMIN
9. BWC : E1, C2 & C4 BROKEN - VMAX
10. BWC : E1, C2 & C4 BROKEN - VMIN
11. BWC : E1, C2 & C6 BROKEN - VMAX
12. BWC : E1, C2 & C6 BROKEN - VMIN
13. BWC : E1, C4 & C6 BROKEN - VMAX
14. BWC : E1, C4 & C6 BROKEN - VMIN
15. BWC : C1, C3 & C5 BROKEN - VMAX
16. BWC : C1, C3 & C5 BROKEN - VMIN
17. BWC : C2, C4 & C6 BROKEN - VMAX
18. BWC : C2, C4 & C6 BROKEN – VMIN
*************************************
ERECTION NORMAL CONDITION (SAFETY REQUIREMENTS)
19. NC - VMAX Erection
20. NC - VMIN Erection
************************************

1
ERECTION BROKEN WIRE CONDITIONS (SAFETY REQUIREMENTS)
21. BWC : E1, C1 & C3 BROKEN - VMAX
22. BWC : E1, C1 & C3 BROKEN - VMIN
23. BWC : E1, C1 & C5 BROKEN - VMAX
24. BWC : E1, C1 & C5 BROKEN - VMIN
25. BWC : E1, C3 & C5 BROKEN - VMAX
26. BWC : E1, C3 & C5 BROKEN - VMIN
27. BWC : E1, C2 & C4 BROKEN - VMAX
28. BWC : E1, C2 & C4 BROKEN - VMIN
29. BWC : E1, C2 & C6 BROKEN - VMAX
30. BWC : E1, C2 & C6 BROKEN - VMIN
31. BWC : E1, C4 & C6 BROKEN - VMAX
32. BWC : E1, C4 & C6 BROKEN - VMIN
33. BWC : C1, C3 & C5 BROKEN - VMAX
34. BWC : C1, C3 & C5 BROKEN - VMIN
35. BWC : C2, C4 & C6 BROKEN - VMAX
36. BWC : C2, C4 & C6 BROKEN – VMIN
LOADS FOR DDE TYPE TOWER
NORMAL CONDITIONS (RELIABILITY REQUIREMENTS)
37. NC -VMAX Normal Load
38. NC - VMIN Normal Load
************************************
BROKEN WIRE CONDITIONS (SECURITY REQUIREMENTS)
39. BWC : E1, C1 & C3 BROKEN – V MAX
40. BWC : E1, C1 & C3 BROKEN – V MIN
41. BWC : E1, C1 & C5 BROKEN - VMAX
42. BWC : E1, C1 & C5 BROKEN - VMIN
43. BWC : E1, C3 & C5 BROKEN - VMAX
44. BWC : E1, C3 & C5 BROKEN - VMIN
45. BWC : E1, C2 & C4 BROKEN - VMAX
46. BWC : E1, C2 & C4 BROKEN - VMIN
47. BWC : E1, C2 & C6 BROKEN - VMAX
2
48. BWC : E1, C2 & C6 BROKEN - VMIN
49. BWC : E1, C4 & C6 BROKEN - VMAX
50. BWC : E1, C4 & C6 BROKEN - VMIN
51. BWC : C1, C3 & C5 BROKEN - VMAX
52. BWC : C1, C3 & C5 BROKEN - VMIN
53. BWC : C2, C4 & C6 BROKEN - VMAX
54. BWC : C2, C4 & C6 BROKEN – VMIN
*************************************
ERECTION NORMAL CONDITION (SAFETY REQUIREMENTS)
55. NC - VMAX Erection
56. NC - VMIN Erection
************************************
ERECTION BROKEN WIRE CONDITIONS (SAFETY REQUIREMENTS)
57. BWC : E1, C1 & C3 BROKEN - VMAX
58. BWC : E1, C1 & C3 BROKEN - VMIN
59. BWC : E1, C1 & C5 BROKEN - VMAX
60. BWC : E1, C1 & C5 BROKEN - VMIN
61. BWC : E1, C3 & C5 BROKEN - VMAX
62. BWC : E1, C3 & C5 BROKEN - VMIN
63. BWC : E1, C2 & C4 BROKEN - VMAX
64. BWC : E1, C2 & C4 BROKEN - VMIN
65. BWC : E1, C2 & C6 BROKEN - VMAX
66. BWC : E1, C2 & C6 BROKEN - VMIN
67. BWC : E1, C4 & C6 BROKEN - VMAX
68. BWC : E1, C4 & C6 BROKEN - VMIN
69. BWC : C1, C3 & C5 BROKEN - VMAX
70. BWC : C1, C3 & C5 BROKEN - VMIN
71. BWC : C2, C4 & C6 BROKEN - VMAX
72. BWC : C2, C4 & C6 BROKEN – VMIN
ANTI-CASCADING LOAD FOR ANGLE TOWER
73. BWC : C2, C4 & C6 BROKEN – VMIN