0% found this document useful (0 votes)
76 views3 pages

Mod Srme

This document summarizes the key features of Chromalox SRM/E self-regulating heating cable: 1) It is used for process temperature maintenance and freeze protection of pipes, valves, and tanks in industrial environments. 2) It is self-regulating, adjusting its heat output based on the temperature of the item being heated to be more energy efficient. 3) It can withstand high temperatures up to 420°F and be steam cleaned on process equipment up to 300 PSIG.

Uploaded by

Cheng Qu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
76 views3 pages

Mod Srme

This document summarizes the key features of Chromalox SRM/E self-regulating heating cable: 1) It is used for process temperature maintenance and freeze protection of pipes, valves, and tanks in industrial environments. 2) It is self-regulating, adjusting its heat output based on the temperature of the item being heated to be more energy efficient. 3) It can withstand high temperatures up to 420°F and be steam cleaned on process equipment up to 300 PSIG.

Uploaded by

Cheng Qu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Heating Cable

SRM/E D

Self-Regulating
Medium Temperature E C B A

• Self-Regulating, Energy Efficient


• 16 AWG Buss Wire
• Circuit Lengths to 750 Feet Maintains up to

302°F
• Process Temperature

Output
Withstands up to

Maintenance to 302°F (150°C) 420°F Temperature

Cut to Length Can be Medium Tem- Self Regulating


• Maximum Continuous Exposure in Field Overlapped perature Output
Temperature, Power Off, 420°F
(215°C)
• Industrial Process Maintenance Features E High Temperature Fluoropolymer
Applications • Energy efficient, self-regulating SRM/E uses Overjacket (optional) — Corrosion
less energy when less heat is required. resistant, flame retardant overjacket is
• Industrial Freeze Protection highly effective in hostile, aqueous and
Applications • Easy to install, SRM/E can be cut to any chemically active environments. It also
length (up to max. circuit length) in the field. protects against abrasion and impact
• Single or Dual Monitor Wires damage.
• Field splices can be performed easily in min-
Available utes with no scrap or wasted cold sections.
Approvals
• Steam Cleanable on Process • With lower installed cost than steam tracing,
Factory Mutual (FM) Approved, UL Listed, and
Equipment Up to 300 PSIG SRM/E features less maintenance expense
and downtime. CSA certified for ordinary areas. UL Listed for
• 5, 8, 10, 15 and 20 W/Ft. freeze protection of fire protection system pip-
• SRM/E can be overlapped without burnout, ing. ATEX, IECEx, FM, and CSA Approved for
• 120 and 208 - 277 Volt From Stock which simplifies heat tracing of in-line pro- hazardous (classified) areas when used with U
cess equipment such as valves, elbows and Series, HL, DL, and EL accessories.
• Approximate Size 3/8"W x 1/8"H pumps.
CSA and FM Approved:
• Minimum Bend Radius 1-1/8" • Because SRM/E is self-regulating, overtem-
perature conditions are minimized. • Class I, Div. 1* & 2 Groups A*, B, C, D
• For Use on Metallic Pipes Only (gases, vapors)
• Chromalox termination, splice, tee and end
seal kits reduce installation time. • Class II, Div. 1*& 2 Groups E*, F, G
(combustible dust)
Description
Construction • Class III, Div. 2
Chromalox SRM/E self-regulating heating
cable provides safe, reliable heat tracing for A Twin 16 AWG Copper Buss Wires — (easily ignitable fibers and fillings)
process temperature maintenance and freeze Provide reliable electrical current
capability. • 5 and 8 Watt Rated T3 Temperature Class
protection of pipes, valves, tanks and similar
applications. Constructed of industrial grade • 10, 15, and 20 Watt Rated T2D Temperature
B Semiconductive Polymer Core Matrix —
16 AWG buss wire with metal braid and op- “Self-Regulating” component of the cable, Class
tional overjacketing, SRM/E ensures operating its electrical resistance varies with
integrity in most hostile industrial environ- *CSA Only
temperature. As process temperature
ments. The 420°F (215°C) maximum exposure *-CT overjacket only
drops, the core’s heat output increases;
temperature rating allows steam cleaning of as process temperature rises, the heat ATEX Approved:
process equipment with up to 300 psig steam. output decreases.
• CE 0359 IIG Ex e IIC T* Gb
WARNING — A ground fault protection device C High Temperature Fluoropolymer Jacket Ta -60˚C to 195˚C
is required by NEC to minimize the danger of — Flame retardant, electrically insulates
the matrix and provides corrosion IECEx Approved:
fire if the heating cable is damaged or improp-
resistance. • ITS 07.0018X Ex e IIC T3 Gb Ta -60˚C to 195˚C
erly installed. A minimum trip level of 30mA is
recommended to minimize nuisance tripping. D Metallic Braid — Provides additional Note 1 Exception — Cable Surface Tempera-
mechanical protection in any environ- ture shall not exceed 190°C in Class II, Div. 2,
ment and a positive ground path. Group F; 165°C in Class II, Div. 2 Group G.

G-16
Heating Cable

SRM/E
Self-Regulating Thermal Output Ratings on Insulated Metal Pipe1
Medium Temperature 24

(cont’d.) Cable Output vs.


Temperature
20

20 W/Ft.

16

Heat Output (W/Ft.) 15 W/Ft.

12

10 W/Ft.

8
8 W/Ft.

5 W/Ft.
4

0
30 50 70 90 110 130 150 170 190 210 230 250 270 290 300
Pipe Temperature (˚F)

Note 1 — Thermal output is determined per IEEE 515-2011 Standard for testing, design
installation, and maintenance of electrical resistance heat tracing section 4.1.11
Method C.
Output Wattage at Alternate Voltages (W/Ft.)
% Change % Change % Change
Model 208V In Output 220V In Output 277V In Output
SRM/E 5 3.85 -23 4.25 -15 6.45 +23
SRM/E 8 6.4 -20 6.88 -14 10.24 +22
SRM/E 10 8.3 -17 8.80 -12 12.50 +20
SRM/E 15 12.75 -15 13.50 -10 18.45 +19
SRM/E 20 17.6 -12 18.40 -8 24.40 +19

SELF-REGULATING
Circuit Breaker Selection (Max. Circuit Lengths in Ft.)

50°F Start-Up (Ft.) 0°F Start-Up (Ft.) -20°F Start-Up (Ft.)
Cable
Rating 15A 20A 30A 40A 50A 15A 20A 30A 40A 50A 15A 20A 30A 40A 50A
SRM/E 5-1 180 240 360 375 NR 165 220 330 375 NR 155 210 310 375 NR
SRM/E 5-2 360 480 720 750 NR 325 430 645 750 NR 310 415 620 750 NR
SRM/E 8-1 145 190 285 325 NR 135 175 265 325 NR 130 165 250 325 NR
SRM/E 8-2 285 380 575 650 NR 255 345 520 650 NR 245 335 490 650 NR
SRM/E 10-1 95 125 190 250 NR 90 110 175 250 NR 85 100 170 245 250
SRM/E 10-2 190 255 385 490 NR 165 225 345 490 NR 155 215 330 470 490
SRM/E 15-1 70 95 145 190 210 65 85 125 165 210 60 80 120 150 210
SRM/E 15-2 145 190 290 385 420 120 175 270 360 420 115 165 260 340 420
SRM/E 20-1 60 75 115 155 160 50 65 105 140 160 45 65 100 135 160
SRM/E 20-2 115 155 230 305 350 100 135 200 270 350 90 130 195 255 335
NR = Not Required. Maximum circuit length has been reached in a smaller breaker size.
Note — Thermal magnetic circuit breakers are recommended since magnetic circuit breakers could "nuisance trip" at low temperature.

G-17
Heating Cable

SRM/E Ordering Information


Output
(W/Ft.) Volts Model Stock PCN
Wt./1000'
(Lbs.)
Self-Regulating 120 SRM/E 5-1C
SRM/E 5-1CT
S
S
388084
388092
80
100
Medium Temperature 5 @ 50°F
208 - 277 SRM/E 5-2C
SRM/E 5-2CT
S
S
388113
388121
80
100
(cont’d.) 120 SRM/E 8-1C
SRM/E 8-1CT
S
S
388148
388156
80
100
8 @ 50°F
SRM/E 8-2C S 388172 80
208 - 277 SRM/E 8-2CT S 388180 100
SRM/E 10-1C S 388201 80
120 SRM/E 10-1CT S 388210 100
10 @ 50°F
SRM/E 10-2C S 388236 80
208 - 277 SRM/E 10-2CT S 388244 100
SRM/E 15-1C S 388260 80
120 SRM/E 15-1CT S 388279 100
15 @ 50°F
SRM/E 15-2C S 388308 80
208 - 277 SRM/E 15-2CT S 388316 100
SRM/E 20-1C S 388332 80
120 SRM/E 20-1CT S 388340 100
20 @ 50°F
SRM/E 20-2C S 388367 80
208 - 277 SRM/E 20-2CT S 388375 100
To Order — Specify length, model, PCN and installation accessories.

Accessories
Accessories U Series DL EL
Power Connection Heat trace to electrical service connection UPC RTPC SSK
Splice & Tee UMC RTST RT-TST
End Seal For terminating cable UES RTES N/A
Lighted End Seal UESL RTST-SL N/A
Thermostat Ambient air sensing thermostat UAS RTAS THL/TXL
Line sensing mechanical thermostat UBC RTBC THR/TXR
To Order — General Application & Installation Accessories such as tape, pipe straps,
warning labels, etc., refer to the U Series, DL & EL General Application
Accessories page at the end of this section.

Ordering Model Self-Regulating Medium Temperature


Information SRM/E Self-Regulating, Medium Temperatue Enhanced Heating Cable
To Order — Code Output (W/Ft.)
Complete the 5 Five
Model Number 8 Eight
using the Matrix 10 Ten
provided. 15 Fifteen
20 Twenty
Code Voltage
1 120
2 208 - 277
Code Braid and Overcoat Options
More Information C Tin-Plated copper metallic braid for
is Available Online additional protection and ground
path
on Heat Trace. CT Fluoropolymer corrosion resistant
overjacket over braid for hostile/
Bookmark Your Browser to corrosive environments
www.chromalox.com
and Select Manuals. SRM/E 8 1 CT Typical Model Number