SUN2000-450W-P2 600W-P Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Smart PV Optimizer

One-Fits-All Optimizer <5s Module Auto-Mapping Arc Fault Pinpoint


Easier Business Positioning Along PV Cable

Technical Specification SUN2000-450W-P2 SUN2000-600W-P

Input
Rated Input DC Power 1 450 W 600 W
Absolute maximum input voltage 80 V
MPPT operating voltage range 10 - 80 V
Maximum Short Circuit Current (Isc) 14.5 A
Max. efficiency 99.5 %
Weighted efficiency 99.0 %
Overvoltage category II

Output
Max. output voltage 80 V
Max. output current 15 A
Output bypass 2 Yes
Shutdown output voltage per optimizer 3 0V
Shutdown output impedance per optimizer 1k ohm ± 10 %

Communication
Communication Method MBUS

Standard Compliance
Safety IEC62109-1 (class II safety)
RoHS Yes

General Data
Dimension (W x H x D) 75 x 140 x 28 mm (3.0 x 5.5 x 1.1 inch)
Weight (including cables) 0.6 kg (1.3 lb.)
Installation part (optional) Frame Mounting Bracket / T-shaped Bolt 4

Input connector MC4


Input wire length 0.15m
Output connector MC4
Output wire length 1.3 m (4.3 ft.) 5
Operating temperature / humidity range -40 ℃~85 ℃ 5 / 0 %RH~100 %RH
Degree of protection IP68
Compatible product SUN2000-2/3/3.68/4/4.6/5/6KTL-L1, SUN2000-3/4/5/6/8/10KTL-M1,
SUN2000-12/15/17/20KTL-M2, SUN2000-30/36/40KTL-M3

Long String Design (Full Optimizer) SUN2000-2-6KTL-L1 SUN2000-3-10KTL-M1 SUN2000-12-20KTL-M2 SUN2000-30-40KTL-M3

Minimum optimizer number per string 6 4 6 6 6


Maximum optimizer number per string 25 35 35 25
Maximum DC power per string 6,000 W 10,000 W 12,000 W 12,000 W
*1 In the STC environment, The rated power of the module shall not exceed 1.05 times of the optimizer rated input power.
*2 Power optimizer is bypassed in the string connected to an operating inverter when it fails to work
*3 Power optimizer output 0Vdc when disconnecting to the inverter or inverter is shutdown.
*4 Allow PV module frame installation / extruded aluminum profile installation
*5 Fits PV module in landscape and portrait installation.
*6. Require standard 60 cells module to meet the inverter minimum startup voltage
*7 Full power capability refers to online smart design tool. SOLAR.HUAWEI.COM

You might also like