ParkerAE Pumps Condensed Catalog
ParkerAE Pumps Condensed Catalog
Introduction
Parker Autoclave Engineers has always been a large user of Air-over-Liquid pump technology and has a lifetime of experience
using all variety of pumps in many different configurations. We have used this experience to develop a best-in-breed line of
air-driven, high pressure pumps that are efficient to operate, simple in design, and will stand the test of time. Compared to
other types of hydraulic pumps, they provide cost effective and energy saving benefits for many applications in the Oil and
Gas, Chemical, Industrial and Research industries.
These pumps convert simple air pressure into high and ultra-high liquid pressures by utilizing a large area piston on the air
side to move a small area plunger to compress the liquid into very high hydraulic pressures - as high as 60,000 psi
(4137 bar). Some designs are for economy, some for manual use, some for low-flow & high pressure, some for high flow &
medium pressure… Choice – what a concept! Pumps like these are perfect for product testing, valve actuation, chemical
injection and other applications that require intense pressure. When used in conjunction with a Hydraulic Intensifier (another
PAE product) pressures to 150,000 psi (10,000 bar) are normal.
Parker Autoclave Engineers has been making pressure and corrosion test systems as well as high pressure laboratory reaction
vessels for over 70 years. Packaged Pressure Systems incorporating these Air-Driven, High Pressure Liquid pumps, plus our
valves, fittings and other instrumentation was an automatic success story. We have created a wide range of self-contained
portable, custom framed modules that “plug and play” for virtually any pressure test, control, or injection system you can
imagine. They vary in size, flow capability, output pressure and can include optional features such as chart recording, data
logging, cycle counters, injection controllers and almost any kind of electric or pneumatic valve control option.
2 Catalog: 02-9326BE
Pump Series Models
ASL Series:
• Standard Liquid Pump
• Pressures up to 60,000 psi (4137 bar)
• Approximately 6 inches in diameter air piston
• Broad range of ratios
ACL Series:
• Compact Liquid Pump
• Pressures up to 31,900 psi (2199 bar)
• Approximately 3 inches in diameter air piston
ACHL Series:
• ACL Series Pump with hand lever
• Pressures up to 31,900 psi (2199 bar)
• Precise Pressure control operation, pump is spring returned
AHL Series:
• High Flow Liquid
• Pressures up to 13,300 psi (917 bar)
• Approximately 10 inches in diameter air piston
• Dual Acting
AFL Series:
• High Flow, High Pressure
• Pressures up to 12,500 psi (862 bar)
• Flow up to 3 gpm
• Dual Acting
Drive Types
Pump
Model
Catalog
Number Suffix -01 -02 -1D -2D
Catalog: 02-9326BE 3
Quick Reference Guide
ACHL Series
ACHL72-01 1:84 12,500 (862) 0.09 (1.47) 3/8” FNPT F250C
ACHL189-01 1:213 31,900 (2,1990) 0.035 (0.57) 3/8” FNPT F250C
ASL Series
ASL10-01 1:11 1,600 (110) 5.22 (85.5) 1” FNPT 1/2” FNPT
ASL15-01 1:16 2,300 (159) 3.62 (59.3) 1” FNPT 1/2” FNPT
ASL25-01 1:28 4,000 (276) 2.10 (34.4) 1/2” FNPT 1/2” FNPT
ASL35-01 1:39 5,600 (386) 1.50 (24.64) 1/2” FNPT 1/2” FNPT
ASL60-01 1:70 10,000 (689) 0.84 (13.8) 1/2” FNPT 1/2” FNPT
ASL100-01 1:113 15,000 (1,034) 0.52 (8.5) 1/2” FNPT 1/2” FNPT
ASL150-01 1:150 21,500 (1,482) 0.39 (6.4) 1/2” FNPT F250C
ASL250-01 1:265 38,400 (2,648) 0.22 (3.6) 1/2” FNPT F250C
ASL400-01 1:398 57,700 (3,978) 0.14 (2.3) 1/2” FNPT F250C
ASL10-02 1:22 3,200 (221) 5.22 (85.5) 1” FNPT 1/2” FNPT
ASL15-02 1:32 4,600 (317) 3.62 (59.3) 1” FNPT 1/2” FNPT
ASL25-02 1:56 8,100 (558) 2.10 (34.4) 1/2” FNPT 1/2” FNPT
ASL35-02 1:78 11,200 (772) 1.50 (24.64) 1/2” FNPT 1/2” FNPT
ASL60-02 1:140 20,000 (1,379) 0.84 (13.8) 1/2” FNPT 9/16” SF562CX
ASL100-02 1:226 31,000 (2,137) 0.52 (8.5) 1/2” FNPT F250C
ASL150-02 1:300 43,000 (2,965) 0.39 (6.4) 1/2” FNPT F250C
ASL250-02 1:530 60,000 (4,137) 0.22 (3.6) 1/2” FNPT F250C
ASL400-02 1:796 60,000 (4,137) 0.14 (2.3) 1/2” FNPT F250C
AHL Series
AHL33-2D 1:67 6,700 (462) 15.3 (250.7) 1” FNPT 1/2” FNPT
AHL66-2D 1:133 13,300 (917) 7.8 (127.8) 1/2” FNPT 1/2” FNPT
AFL Series
AFL35-1D 1:39 5,600 (386) 6.02 (98.7) 1” FNPT 9/16” SF562CX
AFL60-1D 1:70 10,000 (690) 3.40 (55.7) 1” FNPT 9/16” SF562CX
AFL100-1D 1:113 15,000 (1034) 2.30 (37.7) 1” FNPT 9/16” SF562CX
4 Catalog: 02-9326BE
Pump Operation
Piston to Plunger Ratio
• Compressed air is used to produce hydraulic pressure
• Works on differential surface area between the large air piston and smaller hydraulic plunger
• Differential is represented by the pressure ratio of the pump
AIR DRIVE FORCE
(AREA X PRESSURE)
Pressure Ratio = Area of Air Piston ÷ Area of Hydraulic Plunger
• The higher the pressure ratio, the higher the output hydraulic pressure
AIR PISTON
Section 1
Section 2
Catalog: 02-9326BE 5
Typical Pump Cut-Away
H
A
B
I
C
J
E
K
G M
O N
Description Description
A Air Inlet I Air Piston Bumper
B Top End Cap J Air Piston
C Air Muffler K High Pressure Seal Assembly
D Air Cylinder L Liquid Inlet Connection
E Bottom End Cap M Inlet Check Valve
F High Pressure Outlet Connection N Pump Head Body
G Outlet Check Valve O Hydraulic Plunger
H Pilot Valve
6 Catalog: 02-9326BE
Pump Special Features & Benefits
• All Aluminum parts machined from high quality bar stock, not cast aluminum components
• Anodizing with special sealing technique to provide better protection from harsh environments
• Muffler specified to give a great combination of high flow and low noise
• Rubber bumpers in end caps to reduce noise of operation
• Latest lubrication technology provides long seal service life and improves pump efficiency and performance
• No lubricator required for air drive source
• Stainless steel tie-rods and hardware
• Stainless plunger coated with a proprietary multi-layer carbon based coating with diamond like carbon
exterior layer:
• High hardness (3 times harder than Stellite)
• Inert, it has superior chemical compatibility and corrosion resistance
• Low friction that limits seal wear and increases efficiency (coefficient of friction equal to or less than PTFE)
• Tough coating that provides long plunger cycle life. (Have never had to replace a coated plunger during
prototype testing)
• Pressure head specially designed and engineered for high cycle life
• Spring energized u-cup seal provides better sealing performance at wide ranges of pressures
• Extended service life check valves with Ceramic balls for high pressure applications
Catalog: 02-9326BE 7
ACL SERIES Single-Acting, Single Piston Air Drive
• Single-Acting, Single or Double Piston Air Drive
• Service: Oil, Water, Water/Oil mixture and other fluids depending on material
compatibility
• Maximum Operating Temperature: 0-140º F (-18º to 60º C)
• Net Weight: 8 lbs. (3.6 kg)
• Pressure Head: 316 Stainless Steel
• Plunger: 440 Stainless Steel
• Check Valve Glands: 15-5PH Stainless Steel
• Liquid Seal: see Ordering Guide for options
• Air Drive Seals: Buna N
Reference Guide
Maximum Rated Displacement Liquid Connections
Pump Model Pressure
Outlet Pressure Per Cycle
Series Ratio Inlet Outlet
PSI (bar) .in³ (cm³)
ACL Series
ACL72-01 1:88 12,500 (862) 0.09 (1.47) 3/8” FNPT F250C
ACL111-01 1:130 18,850 (1,300) 0.05 (0.08) 3/8” FNPT F250C
ACL189-01 1:220 31,900 (2,199) 0.04 (0.07) 3/8” FNPT F250C
ACL189-02 1:440 60,000 (4,137) 0.04 (0.07) 3/8” FNPT F250C
Air Drive Connection - All ACL series pumps have a 1/4” FNPT main air drive supply connection
3.79
(96.34)
3.40 See Note
(85.44) 1.97
(49.99)
Slot Spacing 4.69
Both Brackets See Note (119.00)
.32
(8.13)
6.11
(155.09)
Bracket
Front View Slot Spacing
Pilot Valve
Vent
See Note
Liquid Outlet
Parker Autoclave
F250C 1/4” Female
High Pressure
Liquid inlet Connection
Female Left View
3/8” NPT 2.47
(62.74) 1.81
5.19 (45.97)
(131.83)
Side inlet
8 Catalog: 02-9326BE
0.48 0.48
4.06 4.06
(12.10) (12.10)
1/4” NPT (103.12) (103.12)
1/4” NPT
Air Drive Air Drive
Inlet Inlet
1.52 1.52
(38.49) (38.49)
6.07
8.45
(154.09)
(214.53)
outlet
outlet
6.80
9.18
(172.72)
(233.17)
Side inlet
Side inlet
8.81
11.19
(223.77)
(284.17)
Bottom
Bottom inlet
inlet
Right View
Single Piston
Note:
Each mounting bracket includes (2) x 3/8” (9.53) slots for 5/16” bolts.
Bottom inlet pump head and side inlet pump head are mutually exclusive. Right View
All dimensions are for reference only and are subject to change without notice.
Double Piston
Primary dimensions: Inches
Secondary Dimensions: (Millimeters)
Ordering Guide
ACL189-01 S N P
Pump Series Liquid Inlet Isolation
Liquid Seal Material
Type/Size/Ratio Location Chamber
ACL S* = Side N* = None P* = UHMWPE U-Cup with Elgiloy
• Compact Liquid High Pressure Pump B = Bottom Spring Energizer
• 3” Single Piston Air Drive U = Urethane U-Cup
• 1:220 Air-to-Liquid Pressure Ratio
• Maximum 31,900 psi (2,199 bar)
Flow Rate Table: Air Drive Pressure (psi) vs. Outlet Pressure (psi)
Air Drive Outlet Pressure (psi)
Catalog
Pressure
Number 0 500 1,500 3,000 5,000 7,500 10,000 15,000 25,000 40,000 55,000
(psi)
60 42 32 17 9 1
ACL72-01 90 42 34 25 18 7 1
120 43 35 29 24 17 7 2
60 28 23 14 9 5 1
ACL111-01 90 28 25 19 15 10 5 2
in3 /min.
120 29 26 21 18 15 10 6 1
60 15 15 14 13 12 9 6
ACL189-01 90 15 15 15 14 14 13 11 6
120 15 15 15 15 15 14 13 10 1
60 13 12 11 10 9 7 7 5 1
ACL189-02 90 14 13 12 11 8 8 8 7 5
120 17 16 14 12 10 9 8 8 7 4
Catalog: 02-9326BE 9
ACHL SERIES Single-Acting, Single Air Drive with Hand Lever
• Single-Acting, Single Air Drive with Hand Lever
• Service: Oil, Water, Water/Oil mixture and other fluids depending on material
compatibility
• Standard Hand Lever for precise pressure control, remote locations or
emergency back-up applications.
• Maximum Operating Temperature: 0-140º F (-18º to 60º C)
• Net Weight: 8 lbs. (3.6 kg)
• Pressure Head: 316 Stainless Steel
• Plunger: 440 Stainless Steel
• Check Valve Glands: 15-5PH Stainless Steel
• Liquid Seal: see Ordering Guide for options
• Air Drive Seals: Buna N
Reference Guide
Maximum Rated Displacement Liquid Connections
Pump Model Pressure
Outlet Pressure Per Cycle
Series Ratio Inlet Outlet
PSI (bar) .in³ (cm³)
ACHL Series
ACHL72-01 1:84 12,500 (862) 0.09 (1.47) 3/8” FNPT F250C
ACHL189-01 1:213 31,900 (2,199) 0.035 (0.57) 3/8” FNPT F250C
Air Drive Connection - All ACHL series pumps have a 1/4” FNPT main air drive supply connection
13.49
(342.6)
11.40
(289.5)
1.42
(36.2) 1/4” NPT
Air Drive Inlet
0.23
(5.8)
Liquid Outlet
Autoclave Engineers
F250C - 1/4” Female
High Pressure
Connection
10 Catalog: 02-9326BE
1.31
(33.3)
14.69
(373.1)
0.75
(19.1)
5.95
(151.3)
Bottom View
Bracket
Slot Spacing
See Note
6.80
(172.7)
Side
Inlet
1.63
(41.3)
8.81
(223.7)
Bottom
Inlet
Note:
Each mounting bracket includes (2) x 11/32” (8.73) slots for 5/16” bolts.
Bottom inlet pump head and side inlet pump head are mutually exclusive.
All dimensions are for reference only and are subject to change without notice.
Primary dimensions: Inches
Secondary Dimensions: (Millimeters)
Ordering Guide
ACHL189-01 S N P
Pump Series Liquid Inlet Isolation
Liquid Seal Material
Type/Size/Ratio Location Chamber
ACHL S* = Side N* = None P* = UHMWPE U-Cup with Elgiloy
• Compact Liquid High Pressure Pump B = Bottom Spring Energizer
with hand lever U = Urethane U-Cup
• 3” Single Piston Air Drive
• 1:213 Max. Air-to-Liquid Pressure Ratio
• Maximum 31,900 psi (2,199 bar)
Flow Rate Table: Air Drive Pressure (psi) vs. Outlet Pressure (psi)
Air Drive Outlet Pressure (psi)
Catalog
Pressure
Number 0 500 1,500 3,000 5,000 7,500 10,000 15,000 25,000 40,000 55,000
(psi)
60 42 32 17 9 1
ACHL72-01 90 42 34 25 18 7 1
in3/min.
120 43 35 29 24 17 7 2
60 15 15 15 15 14 13 8
ACHL189-01 90 15 15 15 15 15 13 11 7
120 15 15 15 15 15 13 12 8 1
Catalog: 02-9326BE 11
ASL SERIES Single-Acting, Single or Double Piston Air Drive
• Single-Acting, Single and Double Piston Air Drive
• Service: Oil, Water, Water/Oil mixture and other fluids depending
on material compatibility
• Maximum Operating Temperature: 0-140º F (-18º to 60º C)
• Pressure Head: 316 Stainless Steel
• Check Valve Glands: 316 Stainless Steel
• Liquid Seal: see Ordering Guide for options
• Air Drive Seals: Buna N
Reference Guide
Maximum Rated Displacement Liquid Connections
Pump Model Pressure
Outlet Pressure Per Cycle
Series Ratio Inlet Outlet
PSI (bar) .in³ (cm³)
ASL Series
ASL10-01 1:11 1,600 (110) 5.22 (85.5) 1” FNPT 1/2” FNPT
ASL15-01 1:16 2,300 (159) 3.62 (59.3) 1” FNPT 1/2” FNPT
ASL25-01 1:28 4,000 (276) 2.10 (34.4) 1/2” FNPT 1/2” FNPT
ASL35-01 1:39 5,600 (386) 1.50 (24.64) 1/2” FNPT 1/2” FNPT
ASL60-01 1:70 10,000 (689) 0.84 (13.8) 1/2” FNPT 1/2” FNPT
ASL100-01 1:113 15,000 (1,034) 0.52 (8.5) 1/2” FNPT 1/2” FNPT
ASL150-01 1:150 21,500 (1,482) 0.39 (6.4) 1/2” FNPT F250C
ASL250-01 1:265 38,400 (2,648) 0.22 (3.6) 1/2” FNPT F250C
ASL400-01 1:398 57,700 (3,978) 0.14 (2.3) 1/2” FNPT F250C
ASL10-02 1:22 3,200 (221) 5.22 (85.5) 1” FNPT 1/2” FNPT
ASL15-02 1:32 4,600 (317) 3.62 (59.3) 1” FNPT 1/2” FNPT
ASL25-02 1:56 8,100 (558) 2.10 (34.4) 1/2” FNPT 1/2” FNPT
ASL35-02 1:78 11,200 (772) 1.50 (24.64) 1/2” FNPT 1/2” FNPT
ASL60-02 1:140 20,000 (1,379) 0.84 (13.8) 1/2” FNPT 9/16” SF562CX
ASL100-02 1:226 31,000 (2,137) 0.52 (8.5) 1/2” FNPT F250C
ASL150-02 1:300 43,000 (2,965) 0.39 (6.4) 1/2” FNPT F250C
ASL250-02 1:530 60,000 (4,137) 0.22 (3.6) 1/2” FNPT F250C
ASL400-02 1:796 60,000 (4,137 0.14 (2.3) 1/2” FNPT F250C
12 Catalog: 02-9326BE
Ordering Guide
Typical catalog number example: ASL250-01SNP (catalog number is created based on customer selection of product parameters, see below for example)
ASL250-01 S N P
Pump Series Liquid Inlet Isolation
Liquid Seal Material
Type/Size/Ratio Location Chamber
ASL S* = Side N* = None P* = UHMWPE U-Cup
• Standard Liquid High Pressure Pump B = Bottom C = Included (See table below)
• 6” Single Piston Air Drive
• 1:265 Max. Air-to-Liquid Pressure Ratio
• Maximum 38,400 psi (2,648 bar)
Catalog: 02-9326BE 13
Air Drive Connection - All ASL series pumps have a 1/2” FNPT main air drive supply connection and utilize a 1/8” FNPT
pilot port connection for remote start/stop operation. It is recommended to operate the pilot port at a higher air pressure than
the main air drive supply pressure for proper function.
0.99 0.99
(11.94) (11.94)
*As
*AD
*Bs
*Cs
*BD
*Ds
*CD
See Note
Right View
Single Piston
*DD
See Note
Right View
Double Piston
*See following page for product dimensions.
10.60
(269.16) 7.50
5.03 (190.50)
(127.96) 6.38
1/8” FNPT External Pilot Connection (162.05)
3.12 See Note
(79.25)
1.19 Slot Spacing
(30.23) Both Bracket
Front View
Left View
Liquid Outlet
Parker Autoclave
Engineers F250C
- 1/4” Female
High Pressure
Connection
3.41
(86.71)
E
F
Liquid Inlet Female
1/2” NPT
Note:
Each mounting bracket includes (2) x 11/32” (8.73) slots for 5/16” bolts.
Bottom inlet pump head and side inlet pump head are mutually exclusive.
All dimensions are for reference only and are subject to change without notice.
Primary dimensions: Inches
Secondary Dimensions: (Millimeters)
14 Catalog: 02-9326BE
ASL Series: Dimensions
Pump Model
As Bs Cs Ds Es Fs Gs
Series
Single Piston Air Drive
ASL10-01 6.87 (175) 8.25 (210) 9.83 (250) 12.51 (318) 3.27 (83) 7.57 (192) 3.95 (100)
ASL15-01 6.87 (175) 8.25 (210) 9.83 (250) 12.51 (318) 3.27 (83) 7.57 (192) 3.95 (100)
ASL25-01 6.87 (175) 8.25 (210) 9.83 (250) 11.54 (293) 3.27 (83) 6.92 (176) 3.95 (100)
ASL35-01 6.87 (175) 8.25 (210) 9.83 (250) 11.54 (293) 3.27 (83) 6.92 (176) 3.95 (100)
ASL60-01 6.87 (175) 8.31 (211) 9.25 (235) 12.10 (307) 3.43 (87) 7.24 (184) 3.95 (100)
ASL100-01 6.87 (175) 8.31 (211) 9.25 (235) 12.10 (307) 3.43 (87) 7.24 (184) 3.95 (100)
ASL150-01 6.87 (175) 8.31 (211) 9.25 (235) 11.55 (293) 4.18 (106) 7.45 (189) 3.95 (100)
ASL250-01 6.87 (175) 8.31 (211) 9.25 (235) 11.55 (293) 4.18 (106) 7.45 (189) 3.95 (100)
ASL400-01 6.87 (175) 8.37 (213) 9.39 (239) 11.74 (298) 2.75 (70) 6.13 (156) 3.95 (100)
Pump Model
AD BD CD DD ED FD GD
Series
Double Piston Air Drive
ASL10-02 10.81 (275) 12.19 (310) 13.77 (350) 16.45 (418) 3.27 (83) 7.57 (192) 3.95 (100)
ASL15-02 10.81 (275) 12.19 (310) 13.77 (350) 16.45 (418) 3.27 (83) 7.57 (192) 3.95 (100)
ASL25-02 10.81 (275) 12.19 (310) 13.77 (350) 15.48 (393) 3.27 (83) 6.92 (176) 3.95 (100)
ASL35-02 10.81 (275) 12.19 (310) 13.77 (350) 15.48 (393) 3.27 (83) 6.92 (176) 3.95 (100)
ASL60-02 10.81 (275) 12.25 (311) 13.19 (335) 16.04 (407) 3.43 (87) 7.24 (184) 3.95 (100)
ASL100-02 10.81 (275) 12.25 (311) 13.19 (335) 15.50 (394) 4.18 (106) 7.24 (184) 3.95 (100)
ASL150-02 10.81 (275) 12.25 (311) 13.19 (335) 15.50 (394) 4.18 (106) 7.45 (189) 3.95 (100)
ASL250-02 10.81 (275) 12.30 (312) 13.32 (338) 15.68 (398) 2.75 (70) 7.45 (189) 3.95 (100)
ASL400-02 10.81 (275) 12.30 (312) 13.32 (338) 15.68 (398) 2.75 (70) 6.13 (156) 3.95 (100)
Note:
Each mounting bracket includes two (2) x 13/32” (10.32) slots for 3/8” bolts. Bottom inlet pump head and side inlet pump head are mutually
exclusive. All dimensions are for reference only and are subject to change without notice.
Primary Dimensions: Inches
Secondary Dimensions: (Millimeters)
Catalog: 02-9326BE 15
Flow Rate Table: Air Drive Pressure (psi) vs. Outlet Pressure (psi)
Air Drive Outlet Pressure (psi)
Catalog
Pressure
Number 0 500 1,500 3,000 5,000 7,500 10,000 15,000 25,000 40,000 55,000
(psi)
60 1277 489
ASL10-01 90 305 826
120 1360 925
60 887 485
ASL15-01 90 906 591
120 945 642 474
60 508 342 127
ASL25-01 90 520 387 303
120 543 427 360 202
60 315 273 121
ASL35-01 90 322 291 211 58
120 328 302 250 157
60 168 155 125 79
ASL60-01 90 175 161 134 106 63
120 182 167 140 118 94 45
60 104 99 88 70 46
ASL100-01 90 108 103 92 78 65 44 11
120 112 106 95 83 72 60 47
60 81 79 76 66 49 19 in3 /min.
ASL150-01 90 83 82 80 75 67 53 35
120 84 83 82 78 73 66 55 25
60 46 45 44 42 37 26 20 2
ASL250-01 90 47 46 45 44 43 40 36 26
120 48 47 47 46 45 43 41 34 17
60 39 38 37 36 33 29 23 10
ASL400-01 90 40 39 38 38 37 35 32 26 8
120 41 40 39 38 38 37 36 32 21
60 880 720
ASL10-02 90 890 800 350
120 900 840 570
60 615 550 200
ASL15-02 90 625 575 410
120 630 600 500 225
60 345 330 265 60
ASL25-02 90 350 335 300 208 15
120 355 345 320 265 150
60 240 230 210 115
ASL35-02 90 242 232 225 190 115
120 245 235 230 210 170 95
16 Catalog: 02-9326BE
Air Drive Outlet Pressure (psi)
Catalog Pressure
Number (psi) 0 500 1,500 3,000 5,000 7,500 10,000 15,000 25,000 40,000 55,000
Catalog: 02-9326BE 17
AHL SERIES Double-Acting, Double Piston Air Drive
• Service: Oil, Water, Water/Oil mixture and other fluids depending
on material compatibility
• Maximum Operating Temperature: 0-140º F (-18º to 60º C)
• Pressure Head: 15-5 PH Stainless Steel
• Check Valve Glands: 316 Stainless Steel
• Liquid Seal: see Ordering Guide for options
• Air Drive Seals: Buna N
Reference Guide
Maximum Rated Displacement Liquid Connections
Pump Model Pressure
Outlet Pressure Per Cycle
Series Ratio Inlet Outlet
PSI (bar) .in³ (cm³)
AHL Series
AHL33-2D 1:67 6,700 (462) 15.3 (250.7) 1” FNPT 1/2” FNPT
AHL66-2D 1:133 13,300 (917) 7.8 (127.8) 1/2” FNPT 1/2” FNPT
Air Drive Connection - All AHL series pumps have a 1” FNPT main air drive supply connection and utilize a 1/8” FNPT
pilot port connection for remote start/stop operation. It is recommended to operate the pilot port at a higher air pressure than
the main air drive supply pressure for proper function.
17.55
(445.71)
Liquid Inlet
Female 1/2” NPT
Liquid Outlet
Female 1/2” NPT
0.50
7.00 (12.70)
(177.80) Slot Sizes
Slot Spacing Types (4) PLCS
11.00
(279.40)
Side View
18 Catalog: 02-9326BE
A
1” NPT Thread
Air Driven Inlet
8.00
1/4” NPT Thread (203.20) 1/4” NPT Thread
5.50 Isolation Drain Port Isolation Drain Port
(139.70)
18.44
(468.27)
Front View
Note:
Model A B
Each mounting bracket includes (2) x 9/16” (8.73) slots for 1/2” bolts.
Bottom inlet pump head and side inlet pump head are mutually exclusive. AHL66 32.66 (829.61) 30.16 (766.11)
All dimensions are for reference only and are subject to change without notice.
Primary dimensions: Inches AHL33 32.41 (823.21) 30.42 (772.41)
Secondary Dimensions: (Millimeters)
Ordering Guide
Typical catalog number example: AHL66-2DSCUV (catalog number is created based on customer selection of product parameters, see below for example)
AHL66-2D S C UV
Pump Series Liquid Inlet Isolation Liquid Seal Material
Type/Size/Ratio Location Chamber (AHL33 and AHL66)
AHL S* = Side C* = Included UV* = Urethane U-Cup and Viton O-Rings
• High Flow Liquid High Pressure Pump UE = Urethane U-Cup and EPDM O-Rings
• 10” Dual Piston Air Drive UB = Urethane U-Cup and Buna-N O-Rings
• 1:133 Max. Air-to-Liquid Pressure Ratio
TV = Thermoplastic Polyester U-Cup and Viton O-Rings
• Maximum 13,300 psi (917 bar)
TE = Thermoplastic Polyester U-Cup and EPDM O-Rings
• Double Acting Liquid Heads
TB = Thermoplastic Polyester U-Cup and Buna-N O-Rings
TC = Thermoplastic Polyester U-Cup and
Perfluoroelastomer O-Rings
C = Perfluoroelastomer O-Rings
* Standard for stock pumps
Catalog: 02-9326BE 19
Liquid Flow Rate vs. Outlet Pressure:
AHL33-2DSC Series
20 Catalog: 02-9326BE
Liquid Flow Rate vs. Outlet Pressure:
AHL66-2DSC Series
Catalog: 02-9326BE 21
AFL SERIES Double-Acting, Single Piston Air Drive
• Service: Oil, Water, Water/Oil mixture and other fluids depending
on material compatibility
• Maximum Operating Temperature: 0-140º F (-18º to 60º C)
• Pressure Head: 15-5 PH Stainless Steel
• Check Valve Glands: 316 Stainless Steel
• Liquid Seal: see Ordering Guide for options
• Air Drive Seals: Buna N
Reference Guide
Maximum Rated Displacement Liquid Connections
Pump Model Pressure
Outlet Pressure Per Cycle
Series Ratio Inlet Outlet
PSI (bar) in³ (cm³)
AFL Series
AFL35-1D 1:39 5,600 (386) 6.02 (98.7) 1” FNPT 9/16” SF562CX
AFL60-1D 1:70 10,000 (690) 3.40 (55.7) 1” FNPT 9/16” SF562CX
AFL100-1D 1:113 15,000 (1034) 2.30 (37.7) 1” FNPT 9/16” SF562CX
Air Drive Connection - All ASL series pumps have a 1” FNPT main air drive supply connection and utilize a 1/8” FNPT
pilot port connection for remote start/stop operation. It is recommended to operate the pilot port at a higher air pressure than
the main air drive supply pressure for proper function.
8.841
(215.43)
Liquid Inlet
Female 1” NPT
Bottom View
22 Catalog: 02-9326BE
7.39
(187.79)
9.36
(250.36) 6.50
(165.10)
4.33
5.81 (109.98)
(147.49) See Note Slot Spacing
Both Brackets
2.40
(60.95)
9.46
(240.40)
11.28
(286.54)
11.81
(299.95) 13.37
(399.55)
24.09
(611.91)
Liquid Outlet
Parker Autoclave Engineers
SF562CX10-9/16”
Female Medium Pressure
Air Inlet
Female
3/4” NPT
Liquid Inlet
Female
1” NPT
Isolation Chamber
Port 1/8” NPT
3.61
(91.61)
5.67
(144.06)
Front View
Right View
Note:
Each mounting bracket includes (2) x 9/16” (14.29) slots for 1/2” bolts.
Bottom inlet pump head and side inlet pump head are mutually exclusive.
All dimensions are for reference only and are subject to change without notice.
Primary dimensions: Inches
Secondary Dimensions: (Millimeters)
Catalog: 02-9326BE 23
Ordering Guide
Typical catalog number example: AFL100-1DBPV (catalog number is created based on customer selection of product parameters, see below for example)
AFL100-1D B C PV
Pump Series Liquid Inlet Isolation Liquid Seal Material
Type/Size/Ratio Location Chamber (AFL35, AFL60, AFL100)
AFL B* = Bottom C* = Included PV* = UHMWPE U-Cup and Viton O-Rings
• High Flow, High Pressure Pump PE = UHMWPE U-Cup and EPDM O-Rings
• 6” Dual Piston Air Drive PB = UHMWPE U-Cup and Buna-N O-Rings
• 1:113 Max. Air-to-Liquid Pressure Ratio
PC = UHMWPE U-Cup and Perfluoroelastomer O-Rings
• Maximum 15,000 psi (1034 bar)
• Single Ended, Double Acting Liquid Heads
Flow Rate Table: Air Drive Pressure (psi) vs. Outlet Pressure (psi)
Air Drive Outlet Pressure (psi)
Catalog
Pressure
Number 0 500 1,500 3,000 4,500 6,000 10,000 15,000
(psi)
60 24 19 9
AFL35 90 25 21 16 6
120 26 23 19 12 2
60 14 12 9 4 Liters /min.
AFL60 90 14 13 11 8 6 1
120 15 14 12 10 8 6
60 10 9 7 5 3 1
AFL100 90 11 10 8 7 6 5 1
120 12 11 9 8 7 6 3
24 Catalog: 02-9326BE
Packaged Pressure Systems
Since our beginning in 1946, Parker Autoclave Engineers has been the world’s market leader in the development and manu-
facture of high and ultra-high pressure components, valves and systems. At our modern factory in Erie Pennsylvania, USA we
have engineers with the specialized experience to design and create products commonly used to control pressures exceeding
100,000 psi (6900 bar) while consistently exceeding customer expectations.
Using the knowledge developed over the last 70 years, Parker Autoclave Engineers Packaged Pressure Systems have been
developed to incorporate any of our Air-Driven, High Pressure Liquid pumps, valves and fittings into a wide range of self-
contained portable, or custom framed modules that “plug and play” for virtually any test, control, or injection system you can
imagine. They vary in size, flow capability, output pressure and can include optional features such as chart recording, data
logging, cycle counters, injection controllers and almost any kind of electric or pneumatic valve control option. Applications
include: Hydrostatic/Burst/Leak/Functional testing, Chemical injection,Valve/Hose/Gauge testing, Bolt tensioning, Hydraulic
Control systems, Laboratory Research and Autofrettage systems.
WARNING
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by
users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog.
Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection
of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation,
product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered by Parker will be
governed by the provisions stated in Parker's standard terms and conditions of sale (copy available upon request).
© 2015 Parker Hannifin Corporation | Autoclave Engineers is a registered trademark of the Parker Hannifin Corporation 02-9326BE May2015
Instrumentation Products Division Instrumentation Products Division Parker Hannifin Manufacturing Ltd. Parker Hannifin Manufacturing Ltd.
Autoclave Engineers Operation Autoclave Engineers Operation, Houston Instrumentation Products Division, Europe Instrumentation Products Division, Europe
8325 Hessinger Drive 15340 Vantage Parkway, East Industrial Estate Whitemill Riverside Road, Pottington Business Park
Erie, PA 16509-4679 Houston, TX 77032 Wexford, Republic of Ireland Barnstaple, UK, EX31 1NP, UK
Tel: 814 860 5700 Tel: 281 987 3828 Tel: 353 53 914 1566 Tel: 44 1271 313131
Fax: 814 860 5811 Fax: 281 987 2318 Fax: 353 53 914 1582 Fax: 44 1271 373636
www.autoclave.com
Caution! Do not mix or interchange component parts or tubing with those of other manufacturers. Doing so is unsafe and will void warranty.
Caution! Parker Autoclave Engineers Valves, Fittings, and Tools are not designed to interface with common commercial instrument tubing and are designed to only
connect with tubing manufactured to Parker Autoclave Engineers AES specifications. Failure to do so is unsafe and will void warranty.
ISO-9001 Certified