HIS Configuration: Day 4 - Engineering Course

The document provides instructions for configuring the HIS (Honeywell Integrated System) and describes its properties and functions. It discusses setting the station type, constants, network settings, message output, closing and long-term data save processes, function keys, and calling up windows. The training covers configuring the HIS interface and assigning functions to keys for operations and monitoring.

Uploaded by

choirul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
528 views81 pages

HIS Configuration: Day 4 - Engineering Course

The document provides instructions for configuring the HIS (Honeywell Integrated System) and describes its properties and functions. It discusses setting the station type, constants, network settings, message output, closing and long-term data save processes, function keys, and calling up windows. The training covers configuring the HIS interface and assigning functions to keys for operations and monitoring.

Uploaded by

choirul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 81

Day 4 – Engineering Course

HIS Configuration

Training Services Center - SVD


Prepared by:
Arsianto Priandana

PT. Yokogawa Indonesia


Wisma Aldiron Dirgantara 2nd floor, suite 202-209
Jl. Jend. Gatot Subroto Kav.72 Jakarta 12780
Phone : 021-799 0102, Fax : 021-799 0070

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.1
Table of Contents

Day 4

1. HIS Configuration
2. Windows Configuration

Laboratory: HIS Configuration and Windows Configuration

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.2
HIS Properties – Station Type

Max .16
Max .64 stations

Used to indicate the connection


origin or connection destination
component numbers when
wiring the devices.

Page L2
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.3
Property of HIS - Constant

ID that allows buzzers on other


HISs with the same buzzer ACK ID
to be reset when a buzzer is
acknowledged on one HIS.
Used for the identification if
different operation groups exist.

Page L3
PT YOKOGAWA INDONESIA Page L-2
Training Center – Technical Support Group Page.4
Property of HIS - Network

The control bus subnet mask is


set to “255.255.0.0” by default

Page L4
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.5
Property of HIS - Network

Leave as default

Change to the following format:


192.168.<dd+128>.<ss+129>

Change to the following format:


255.255.255.0 by default

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.6
HIS Constants

1. Message output may be assigned to different


printers
2. The scope of operation and monitoring of the
designated user group decides the scope of the
message to print out.

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.7
HIS Configuration
HIS Constant Click “Open Interface”

Message output
may be assigned
to different
printers, according
to the message
type

0 to 9 can be
define
When printing, the
scope of operation
and monitoring of
the designated
user group
decides the scope
of the message to
print out

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.8
HIS Constants

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.9
HIS Configuration
Click “Closing Process”
HIS Constant

Set defined group or


non-group

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.10
HIS Configuration
HIS Constant Click “Long-term Data Save”

The Closing Process creates closing data for


statistical processing, such as average values
and total values, based on trend data
acquired by the Trend Recording

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.11
HIS Configuration
Positioning Closed Data

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.12
HIS Configuration
Closed Data

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.13
HIS Configuration

The long-term data archive is intended for the


long-term storage of trend data, closing data and
historical messages as necessity dictates

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.14
HIS Configuration
Long Term data archive

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.15
HIS Configuration
Long Term data save

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.16
HIS Configuration
Changing Block Mode Style

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.17
HIS Configuration
Changing Block Mode Style

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.18
HIS Configuration
Function Keys

Security key Speaker

The Function keys provided on the operation keyboard allow users to


define functions
Function keys freely.
Accompanying each key around the key surface are an LED that indicates
alarms and keys
Auxiliary operation timings to the operator by the flashingPanel
of the lamp
keys
and a label that describes the function assigned to the key.
Conformation keys
Cursor keys

Data entry Scroll keys

Control keys
Acknowledgement Keys

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.19
HIS Configuration – Function Keys

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.20
HIS Configuration – Function Keys
The types of functions assignable to the
function keys include the following:
• Calling up of windows

• Execution of the system function keys

• Starting, stopping or restarting of trend data

• Flashing or turning ON/OFF of LED’s

• Execution of programs by their file names

• Execution of the Multimedia

• Panel set calling

• Calling up of a window to another station

• Calling up of remote windows by window name

• Copying of a currently displayed window set

• Clearing of a window on the remote CRT Page N2


PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.21
Function Keys - Call up of windows
Call up the operation and monitoring windows. A function for calling up windows can be
assigned o a function key.

Not only the operation and monitoring window, builder window can also be called out by
suffixing BDR to the window name of the operation and monitoring window;

e.g. O FIC1000 BDR

Calling a builder window using BDR is valid only when the HIS is installed with basic builder
package and configured information reference package.
Page N3
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.22
Function Keys – Execution of system
Executes the functions provided by the system function keys. The following table shows all
the system function keys:
Hard Copy (HDCP) Window up (CRUP) History File Calling
backward (RECB)
Print (PRNT) Focus (FOCS) Navigator (NAVI)
Message Printout (MSPR) Primary Window Focus User-In (USIN)
(FCSF)
Buzzer Reset (BUZZ) Circulate (CIRC) Clear (CLER)
Stop Voice Play (VOIC) Acknowledgment (ACKN) Message Monitor Window
(MSDW)
Panel set (PSET) Clear Windows (ERAS) Window Shift (SHFT)
Isolate (ISOL) Primary Window Hide Window Exchange (ECHG)
(CLFS)
Window Set Store (WSSV) Primary Window Clear Calling Related Builder
(ERFS) Window (BDRA)
Window Set Delete (WSCL) Active Window Erase Calling Related Control
(ERAW) Drawing Builder Window
(BDRD)
Window down (CRDN) History File Calling forward
(RECF)
Page N3
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.23
Function Keys – Execution of system
function keys
Example of Assigning the System Function to a
Function Key
A system function key is assigned using the format given below:

History File Calling forward (RECF)


K RECF
Sequentially calls up the operation windows displayed in the past,
starting with the oldest one. Up to 30 windows can be called up.

History File Calling backward (RECB)


K RECB
Sequentially calls up the operation windows displayed in the past,
starting with the latest one. Up to 30 windows can be called up.

Page N4
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.24
Function Keys - Starting, stopping or
restarting of trend data
Controls the starting, stopping or restarting of trend data acquisition targeted at
the specified trend groups.

Restart

Page N6
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.25
Function Keys - Flashing or turning
ON/OFF of LED’s
Controls the flashing or turning ON/OFF of LED’s.
■ LED Number
This is the number for the LED to be controlled. Select between 1 and 32 for
external operation keyboard and between 1 and 64 for console type HIS

■ LED Parameter
Select one of the three LED display statuses: “Flashing,” “ON” or “OFF.”

Page N7
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.26
HIS Configuration – Execution of
programs by their file names
Executes programs by specifying their file names.

Page N7
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.27
Function Keys - Execution of the
Multimedia
Plays the specified voice message files.

Copy the multimedia file to be executed to “\his\media\user” under the


system installed directory.

Page N8
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.28
Function Keys – Panel set calling

The pre-defined panel set may be called up.

Page N8
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.29
Function Keys – Calling up of a
window to another station
Calls up the currently displayed active window to the specified HIS.

Page N9
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.30
Function Keys – Calling up of remote
windows by window name
Calls up to the specified HIS windows currently displayed on the CRT. This
function can be used on the console type HIS.

Page N9
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.31
Function Keys – Copying of a
currently displayed window set
Calls up to the specified HIS windows currently displayed on the CRT. This
function can be used on the console type HIS.

Page N10
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.32
Function Keys – Clearing of a
window on the remote CRT
Clears a window called up on the specified
HIS.

Page N10
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.33
HIS Configuration
Panel Set Double Click “Scheduler”

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.34
HIS Configuration
Panel Set

The Panel Set is used to call out multiple windows


together to multiple HIS. Combination of several
windows that are frequently used can be defined as a
panel set and the panel set can be called up with one-
touch operation.

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.35
HIS Configuration
Panel Set
Click “HIS Notification”

This option is used when creating a


system. Notification to other HIS may
be specified.

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.36
HIS Configuration
Panel Set

PET002 Notification GR-M1_input Gr-M2_output

Write
Write
Select
Write
the “GR-M1_input”
panel
“GR-M2_output”
“Notification”
set name
say “PET002”

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.37
HIS Configuration
Panel Set

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.38
Sequence Message Request
The sequence message request is sent by the Process Sequence Control Function at a certain
process timing to an HIS to execute certain Operation and Monitoring Functions.

The functions to be executed for the corresponding request message numbers may be defined
in the HIS.

After the Operation and Monitoring Functions’ execution, the request messages are logged
into the historical message log files. The trigger of request messages is shown as below:

Page P1
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.39
Sequence Message Request
200 Request Message

Faceplate window will be


called upon when FIC300
has a high alarm.

The request message


applies for all station
unless a station name is
specified.

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.40
Panel Set

Up to 200 Panel Sets.

Panel Set name up to 8


alphanumeric character

If a Panel Set is called up,the related panel set names are


notified to all the other HIS’s..

Page Q1
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.41
Panel Set – Example

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.42
Panel Set

The panel set defined in the Panel Set Builder can be called up in the
following manner:

• Assigning a function key

• Defining in the sequence message request

• Define in the Graphic Builder

• Entering a panel set name in the name entry dialog box


Enter “$ + panel set name” in the name entry dialog box.

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.43
Scheduler

Controls the specified applications or tasks to run at the specified time.

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.44
Scheduler

Controls the specified applications or tasks to run at the specified time.

• Calling up windows
• Execution of the system function keys
• Starting, stopping or restarting of trends
• Flashing or turning ON/OFF of LED
• Startup of programs by file names
• Execution of the multimedia function
• Calling up a panel set
• Calling up windows to other stations

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.45
Structure of Trend
The Trend Recording has a three-layer
structure:
1. Trend block
2. Trend window
3. Trend point window.

Page R1

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.46
Structure of Trend

1. Trend Block

There are 50 trend blocks per HIS.


Up to 20 of the 50 trend blocks can be defined in the rotary trend or batch
trend format. The remaining 30 trend blocks are defined as trend of other
stations.

2. Trend Window

There are 16 Trend windows in 1 trend block. Eight-Pen trend data can be
assigned to a Trend window. 800 Trend windows per HIS.

3. Trend Point Window

6,400 Trend Point windows per HIS.

Page M-2

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.47
Sampling Period & Recording Span
of Trend Data
The Trend Recording consists of:
Only 2 trend blocks can be specified with the
1. Trend Data Acquisition
sampling period of 1 second or 10 seconds.
2. Trend Data Display
3. Closing Processing

Acquired trend data can be saved into SVA file, and displayed in
a graph as a trend model (reference pattern).
Page R3

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.48
Trend Window
Format Type of Trend

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.49
Trend Window
Format Type of Trend

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.50
Trend Window
Format Type of Trend

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.51
Trend Window
Format Type of Trend

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.52
Trend Recording – Trend Blocks

50 Trend Blocks

20 Trend Blocks can be


30 Trend Blocks are defined
defined with any of the 3 trend
as trend of other stations
format

No more than 18 Trend Blocks


No more than 2 Trend Blocks
can be specified with sampling
can be specified with sampling
period of 1min, 10min, 5min
period of 1s or 10s
and 10 min

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.53
Structure of Trend

Trend Block

16 Trend
Windows/
Groups
800 Trend windows per HIS.

8 Trend Point
6,400 Trend Point windows per HIS. Window/ Pens
Page Q-
PT YOKOGAWA INDONESIA 2
Training Center – Technical Support Group Page.54
TREND CONFIGURATION
Open the configuraton
from HIS folder

Right Click on the


folder to create a new
trend acquisition pen
assignment

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.55
Trend Properties

Select and right click


on the required trend
acquisition pen
assignment

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.56
TREND CONFIGURATION
Configure the trend

Select trend format


Select sampling periode

If using the Long-term data save, define


how many days the trend data will be
saved in the long-term file.

Type the trendblock comment to give


information about this block

Click OK to finish

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.57
Trend Properties

Sampling Period: 1 s, 10 s, 1 min, 2 mins, 5


mins or 10 mins.
Once Sampling Period is selected the
corresponding recording time is displayed.
If Trend Format: Other Station Acquisition Trend
is selected, a Station Name and its Reference
Block Number will have to be specified

Specify a suitable Trend Data Store


Time
Depending on the number of days
specified, the corresponding required
disk capacity is displayed

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.58
TREND CONFIGURATION
New Trend Block configuration

Appear new Trend Block

Appear new window in the window folder

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.59
TREND CONFIGURATION
New Trend Block configuration

Select the Trend Group

Click
Type the data with format
download to
FIC100.PV
finish “TAGNAME.DATA ITEM”
Example: “FIC100.PV”

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.60
Trend Recording

Specify the
required
acquisition
data

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.61
Trend Recording

• Default
Acquired data are displayed in the default data type in the instrument faceplate
showing the function block of the acquisition source.
• Analog type
Acquired process data are displayed in the data axis range 0 to 100 % of the trend
graph.
• Discrete type
Acquired ON/OFF data are displayed in the fixed data axis range 6 % of the trend
graph.
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.62
Trend Window

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.63
Window Configuration

Page T1
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.64
Window Configuration

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.65
Window Configuration

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.66
Window Configuration
Control Group
Control group window displays the tag elements as instrument faceplates, from
which you can operate and monitor them

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.67
Window Configuration
Control Group
Control group window displays the tag elements as instrument faceplates, from
which you can operate and monitor them

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.68
Window Configuration
Control Group

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.69
Window Configuration
Control Group

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.70
Window Configuration
Control Group Calls up dialog box for assigning
Prints out graphic instrument faceplate. The
window image assignment of the instrument
currently displayed. faceplate may be modified
temporarily in the instrument
Acknowledges Faceplate Assignment dialog box.
alarm.
This button calls up
the Data Bind
Switching dialog box,
only when a graphic
generic name is used
in the Logic Chart
window.
Zoom in/ out

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.71
Page.71
Window Configuration
Overview

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.72
Window Configuration
Overview

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.73
Window Configuration
Overview

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.74
Window Configuration
Overview

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.75
Window Configuration
Overview

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.76
Graphic Window

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.77
Help Window

Page V2
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.78
Help Window
User-defined Help Message

This is a help message that the user can freely define. The user can define help messages to
explain the function and operating procedure for user-defined windows or help messages to
explain the function block.

The user can search for user-defined help by entering the window name, tag name or help
number as the keyword.

The user-definable help message is defined in the Help Message Builder. Define a number
between HW0001 to HW9999 as help number.

The maximum size of one help message is 21 lines, each line can contain 70 single-byte
characters.

Page V3
PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.79
Help Window

Select the
Right Click on the required Help
window required Message
to attach help Number
messages and
select properties

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.80
END

PT YOKOGAWA INDONESIA
Training Center – Technical Support Group Page.81