P2000 V3.12 Software Installation Manual
P2000 V3.12 Software Installation Manual
software
installation
24-10685-130 Revision C
March, 2014
Copyright 2014
Johnson Controls, Inc.
All Rights Reserved
No part of this document may be reproduced without the prior permission of Johnson Controls, Inc.
If this document is translated from the original English version by Johnson Controls, Inc., all
reasonable endeavors will be used to ensure the accuracy of translation. Johnson Controls, Inc.
shall not be liable for any translation errors contained herein or for incidental or consequential
damages in connection with the furnishing or use of this translated material.
Due to continuous development of our products, the information in this document is subject to
change without notice. Johnson Controls, Inc. shall not be liable for errors contained herein or for
incidental or consequential damages in connection with furnishing or use of this material. Contents
of this publication may be preliminary and/or may be changed at any time without any obligation to
notify anyone of such revision or change, and shall not be regarded as a warranty.
Johnson Controls does not duplicate documentation of other equipment manufacturers. When
necessary, Johnson Controls provides documentation that supplements that of other manufacturers.
When unpacking your equipment, keep all original manufacturer documentation for future
reference.
Technical Support
Johnson Controls authorized dealer representatives can call the Field Support Center at
(800) 524-1330 or (414) 524-5000 and use options 6, 1, 7. System users that need information on
maintenance contracts or on-site field support can call a local Johnson Controls sales or service
office.
Acknowledgment
Metasys® and Johnson Controls® are trademarks of Johnson Controls, Inc. All other company and
product names are trademarks or registered trademarks of their respective owners.
Declaration of Conformity
This product complies with the requirements of the EMC Directive 2004/108/EC and the Low
Voltage Directive 2006/95/EEC.
This equipment must not be modified for any reason and it must be installed as stated in the
Manufacturer’s instruction.
If this shipment (or any part thereof) is supplied as second-hand equipment, equipment for sale
outside the European Economic Area or as spare parts for either a single unit or system, it is not
covered by the Directives.
Software Installation Table of Contents
24-10685-130 Rev. C
TABLE OF CONTENTS
Chapter 1: Introduction
Manual Summary 1-1
P2000 Packages 1-2
P2000 Options 1-3
P2000 System Configuration 1-4
Factory Default Values 1-11
i
Software Installation Table of Contents
24-10685-130 Rev. C
ii
Software Installation Introduction
24-10685-130 Rev. C
1. INTRODUCTION
Use the information in this manual to configure your server and to install the
Johnson Controls® P2000 Security Management System (SMS) Version 3.12
SP2 software.
After purchasing a P2000 software-only package, or an upgrade package, start
the procedures described in this document when hardware installation is
complete and all cables are connected.
When you purchase a complete P2000 Security Management System
(hardware and software) package from Johnson Controls, the server hardware
and software are configured and installed at the factory.
Instructions in this document do not include configuration of the backup device
and Crystal Reports installation.
NOTE: Procedures and screen captures in this document may vary slightly,
depending on the software version you are using. Additionally, all of the
procedures assume you are using a mouse; if you are using a touchscreen,
adjust the procedures as required.
MANUAL SUMMARY
1-1
Software Installation Introduction
24-10685-130 Rev. C
P2000 PACKAGES
P2000
P2000 P2000
P2000 Server Software
Workstation Software-
Package Upgrade
Package Only Package
Package
Server/Workstation
Hardware
Operating System
Installed
P2000 User
Documentation
P2000 Tutorial
1-2
Software Installation Introduction
24-10685-130 Rev. C
P2000 OPTIONS
1-3
Software Installation Introduction
24-10685-130 Rev. C
The P2000 SMS operates in a client-server architecture. You must install P2000
software on the system server prior to installing it on the system workstation.
NOTE: Use a dedicated server for the P2000 SMS; that is, install only the
Microsoft Windows® operating system, the SQL Server database engine, and
the P2000 software. To install and run other third-party applications, please
contact a Johnson Controls® Technical Support specialist for assistance.
This section lists and describes supported Windows operating system and SQL
Server combinations for both standard and small P2000 systems.
A standard P2000 SMS includes more than 64 readers, 5,000 cardholders, and
two workstations. Refer to Server Requirements on page 1-7 for more
information.
Table 1-2: Supported P2000 Server Configuration Options for a Standard P2000 SMS
SQL Server 2008 R2
1. OSI panels are not supported on systems with Windows Server 2012 or SQL Server 2012.
2. Recommended platform.
1-4
Software Installation Introduction
24-10685-130 Rev. C
NOTE: Support for OSI panels requires IIS Version 6.0 or 7.0. OSI panels are
not supported on systems with Windows Server 2012 or SQL Server 2012.
Some versions of Windows may require Service Pack installation prior to SQL
Server installation; refer to the Microsoft documentation for more information.
You can use SQL Express with a Windows Server as the database for a small
P2000 SMS; a small P2000 SMS supports fewer readers, cardholders, and
workstations than a standard P2000 SMS. Refer to Server Requirements on
page 1-7 for more information.
Table 1-3: Supported P2000 Server Configuration Options for a Small P2000 SMS
SQL Server 2012 Express (32 bit)
1. Recommended platform.
NOTE: Some versions of Windows may require Service Pack installation prior to
SQL Server installation; refer to the Microsoft documentation for more
information.
1-5
Software Installation Introduction
24-10685-130 Rev. C
The P2000 Web UI software can be installed on the same system hosting
the P2000 Server or on a separate web server.
P2000 Web UI system requirements when installed with a P2000 Server:
• OS and Web server supplied by the P2000 Server installation
• .NET Framework 4 or above
• ASP.NET MVC 4 or above
P2000 Web UI system requirements on a separate web server:
• Windows Server 2012, Windows Server 2008 R2, Windows Server
2008, Windows 8, Windows 7
• Web server software (Microsoft IIS, for example)
• .NET Framework 4 or above
• ASP.NET MVC 4 or above
1-6
Software Installation Introduction
24-10685-130 Rev. C
The P2000 system uses 32-bit ODBC connections and the Data Sources
application launched from the Control Panel is only for 64-bit ODBC
sources.
To modify ODBC connection properties on P2000 systems using 64-bit
operating systems, double-click the following file to launch the 32-bit
version of ODBC:
C:\Windows\SysWOW64\odbcad32.exe
Server Requirements
The following table lists nominal recommendations for the P2000 server.
If you anticipate heavy use of a system feature, such as many CCTV
switches, or heavy use of host events, increase the memory or go to the
next, higher platform. Also, any P2000 Enterprise system or a system
using the Change Tracking option should use the next, higher platform.
1. For a complete list of supported operating systems, see Table 1-2 and Table 1-3.
2. We recommend a 100BASE-T Network controller card for servers.
Use a screen resolution set to 1024 x 768 or higher and color quality set to
Highest (32 bit).
1-7
Software Installation Introduction
24-10685-130 Rev. C
Panel Version
1
CKM-EP1501 1.17.3 and 1.18.7
and Mercury® EP1501
CKM-EP15021 1.17.3 and 1.18.7
and Mercury EP1502
CKM-EP25001 1.17.3 and 1.18.7
and Mercury EP2500
Schlage® PIM400-15012 1.17.3 and 1.18.7
CK721-A 3.1+
CK721 2.8
CK720 2.6
CK705 2.6
S321-DIN All versions
S321-IP 2.10+
OSI Wi-Q Version 3.00.38, Portal Firmware Version
3.0.17.155, Reader Version 3.00.039
Isonas Freescale version 9.20 and PIC version 3.08
HID® 2.2.7.39
Assa Abloy N05+
S320 All versions
Printers
1-8
Software Installation Introduction
24-10685-130 Rev. C
generate the P2000 reports. Select that printer when generating a P2000
report.
Alternatively, use a No Printer check box. Refer to the P2000 Software
User Manual for details.
NOTE: The Microsoft XPS Document Writer, which is the default printer for some
Microsoft operating systems, is not fully compatible with P2000 reports.
1-9
Software Installation Introduction
24-10685-130 Rev. C
1-10
Software Installation Introduction
24-10685-130 Rev. C
NOTE: If you are doing a full P2000 Server installation—Windows OS, SQL
Server, and P2000 software—the computer name will be set to a default value,
not P2000. To change the computer name, do it manually after installing the
Windows OS but before installing SQL Server.
1-11
Software Installation Introduction
24-10685-130 Rev. C
1-12
Software Installation Server Setup
24-10685-130 Rev. C
2. SERVER SETUP
This chapter describes how to prepare a server for the P2000 software
installation.
Install the software system per the manufacturer’s instructions and according to
your system administration requirements. Some P2000-specific settings are
necessary for optimum operation. The following sections provide you with
information on where you must change the default installation or configuration
options.
Use a dedicated server for the P2000 Security Management System; that is,
install on it only the Microsoft Windows® operating system, SQL Server, and
the P2000 prerequisites and software. If you plan to install and run other third-
party applications, contact Johnson Controls® Technical Support for
assistance.
Verify that the server hardware is compatible with the version of Windows you
are using. You may need to perform a firmware upgrade before installing the
operating system. For more information on compatibility and upgrades, refer to
the server manufacturer’s and Microsoft’s documentation.
2-1
Software Installation Server Setup
24-10685-130 Rev. C
If the operating system does not support your computer hardware natively,
install necessary drivers. For instructions, refer to the manufacturer’s
documentation.
Install the operating system per the manufacturer’s instructions.
NOTE: If you are installing the P2000 Server software on a computer running the
Windows Server 2012 operating system, Johnson Controls recommends
installing it with the GUI option.
2-2
Software Installation Server Setup
24-10685-130 Rev. C
4. In the Server Manager window, select Features in the left pane, then
click Add Features.
2-3
Software Installation Server Setup
24-10685-130 Rev. C
NOTE: You may be prompted to click the Add Required Role Services button
at other times during this procedure as well.
NOTE: If you are going to be installing OnSSI codecs, you must also enable
Message Queuing.
2-4
Software Installation Server Setup
24-10685-130 Rev. C
2-5
Software Installation Server Setup
24-10685-130 Rev. C
2-6
Software Installation Server Setup
24-10685-130 Rev. C
13. Wait for the installation to complete and click Close. You may be
prompted to restart the computer.
2-7
Software Installation Server Setup
24-10685-130 Rev. C
2-8
Software Installation Server Setup
24-10685-130 Rev. C
2-9
Software Installation Server Setup
24-10685-130 Rev. C
NOTE: If you are going to be installing OnSSI codecs, you must also enable
Message Queuing.
2-10
Software Installation Server Setup
24-10685-130 Rev. C
2-11
Software Installation Server Setup
24-10685-130 Rev. C
2-12
Software Installation Server Setup
24-10685-130 Rev. C
2-13
Software Installation Server Setup
24-10685-130 Rev. C
2-14
Software Installation Server Setup
24-10685-130 Rev. C
4. On the Before you begin screen of the Add Roles and Features
Wizard, read the text and then click Next.
2-15
Software Installation Server Setup
24-10685-130 Rev. C
7. On the Select server roles screen, select Web Server (IIS); you may
need to scroll down to see this option.
8. When the Add features that are required for Web Server (IIS)?
dialog appears, click Add Features.
2-16
Software Installation Server Setup
24-10685-130 Rev. C
10. On the Select features screen, select .NET Framework 3.5 Features
and Telnet Client (you may have to scroll down to see Telnet Client).
NOTE: If you are going to be installing OnSSI codecs, you must also enable
Message Queuing.
11. Click Next when you have made the appropriate selections.
12. On the Web Server Role (IIS) screen, read the text and then click
Next.
2-17
Software Installation Server Setup
24-10685-130 Rev. C
13. On the Select role services screen, make sure the following are
selected (some may already be selected):
14. When you have finished selecting all of the components, click Next.
2-18
Software Installation Server Setup
24-10685-130 Rev. C
IMPORTANT: If you see a caution message at the top of the Confirm installation
selections screen, this means that one or more source files for the components
you are adding were not installed with Windows Server 2012. Click Specify an
alternate source path for more information. The files you need can be
retrieved from Windows Update (if you have Internet access), from a local
server, or from the Windows Server 2012 installation media. To use files from a
local server or from the installation media, enter the appropriate path and click
OK. If the installer cannot find the necessary files, the installation will fail.
Caution
message
Click for
more
information
2-19
Software Installation Server Setup
24-10685-130 Rev. C
P2000 can use either the Standard or the Express Edition of SQL Server.
The Express Edition, available on the P2000 Prerequisites DVD, has limited
performance and database size, and it is only appropriate for small P2000
systems. See Server Requirements on page 1-7 for more information.
2-20
Software Installation Server Setup
24-10685-130 Rev. C
3. The prerequisite program will check the operating system and the
database engine in order to evaluate which of the updates need to be
installed. If no database engine is detected, you will be informed that
the connection to the database could not be established, and prompted
to install SQL Server Express Edition.
NOTE: SQL Server Standard Edition requires .NET 4.0 as a prerequisite, except
when the operating system is Windows Server 2012 (which automatically
installs a supported version of .NET).
2-21
Software Installation Server Setup
24-10685-130 Rev. C
2-22
Software Installation Server Setup
24-10685-130 Rev. C
2-23
Software Installation Server Setup
24-10685-130 Rev. C
2-24
Software Installation Server Setup
24-10685-130 Rev. C
4. In the Setup Support Rules window, verify that all operations have
been completed (no failures are reported). Click OK.
2-25
Software Installation Server Setup
24-10685-130 Rev. C
7. SQL Server 2008 and 2008 R2 only: In the Setup Support Files
window, click Install.
2-26
Software Installation Server Setup
24-10685-130 Rev. C
8. SQL Server 2012 only: In the Product Updates window, click Next
(depending on your system, you may get a warning message if the
installer cannot access Windows Update via the Internet).
2-27
Software Installation Server Setup
24-10685-130 Rev. C
10. SQL Server 2008 R2 and 2012 only: In the Setup Role window, click
Next.
2-28
Software Installation Server Setup
24-10685-130 Rev. C
11. In the Feature Selection window, select the following check boxes:
2-29
Software Installation Server Setup
24-10685-130 Rev. C
12. SQL Server 2008 R2 and 2012 only: In the Installation Rules window,
click Next.
2-30
Software Installation Server Setup
24-10685-130 Rev. C
IMPORTANT: If you select Default instance, the current computer name is used
as the name of the SQL Server database. Do not change the computer name
after this point, as it will disrupt communications between the P2000 Server and
the SQL Server.
2-31
Software Installation Server Setup
24-10685-130 Rev. C
2-32
Software Installation Server Setup
24-10685-130 Rev. C
15. SQL Server 2008 and 2008 R2 only: In the Server Configuration
window, use the following settings for SQL Server services, and click
Next.
2-33
Software Installation Server Setup
24-10685-130 Rev. C
16. SQL Server 2012 only: In the Server Configuration window, use the
following settings for SQL Server services, and click Next.
2-34
Software Installation Server Setup
24-10685-130 Rev. C
18. In the Error Reporting window (SQL Server 2008: Error and Usage
Reporting window), accept the default settings by clicking Next.
2-35
Software Installation Server Setup
24-10685-130 Rev. C
2-36
Software Installation Server Setup
24-10685-130 Rev. C
21. SQL Server 2008 and 2012 only: The Installation Progress window
opens. The installation will take several minutes. When the progress
bar indicates completion, click Next.
2-37
Software Installation Server Setup
24-10685-130 Rev. C
2-38
Software Installation Server Setup
24-10685-130 Rev. C
2-39
Software Installation Server Setup
24-10685-130 Rev. C
2-40
Software Installation Software Upgrade
24-10685-130 Rev. C
3. SOFTWARE UPGRADE
NOTE: If you have an existing P2000 Express Version 3.11 system and want to
upgrade to P2000 Version 3.12 SP2, you must first register your existing system
with a full-version registration key for P2000 Version 3.11, and then follow the
usual upgrade process. Refer to Obtaining the New Registration Key and
Option Keys on page 3-6 for more information on obtaining the registration key.
For software upgrades, the installer uses a folder, such as Cardkey P2000 or
P2000, created during the previous P2000 installation. For new installations of
P2000 software Version 3.12 SP2, the installer creates a P2000 folder.
NOTE: You can deploy the P2000 Version 3.12 SP2 system in a distributed
mode, where the P2000 server is hosted on two separate machines. All the
P2000 services run on one machine (P2000 application server), while the
P2000 databases are hosted on another machine (P2000 database server).
Refer to the Separating the P2000 Application Server from the Database Server
document for more information.
Depending on the software version you are upgrading from, observe the notes
and recommendations listed below to avoid losing data:
• Table 3-1: Upgrade From P2000 V2.3 and Earlier
• Table 3-2: Upgrade From P2000 V2.5
• Table 3-3: Upgrade From P2000 V3.0 and Higher
3-1
Software Installation Software Upgrade
24-10685-130 Rev. C
Item Note
Alarm Filter Alarm Filter is no longer available; a Message Filtering feature has
been introduced.
When you upgrade the P2000 software, the Alarm Filter settings will
be lost. Therefore, run the Alarm Filter Report before the upgrade.
Print the current Alarm Filter configuration for reference and, after the
upgrade, manually re-apply the settings to Message Filtering. See the
P2000 Software User Manual for instructions.
DVR Integration For integration with On-Net Surveillance Systems (OnSSI) Ocularis,
you must install the OnSSI software development kit (SDK) prior to
loading the P2000 software. This SDK is available from the
manufacturer.
BACnet Interface All panels are disabled for BACnet Interface by default. After the
upgrade, select the Enabled for BACnet Interface check box in the
Edit Panel window, on the General tab, for every panel that should be
enabled for BACnet Interface.
CCTV Server If you are using CCTV Server, uninstall it before the upgrade.
Custom Reports The P2000 Version 3.12 SP2 software uses Crystal Reports version
9.0 or higher. Prior to upgrade of the P2000 software, open and save
all previously created custom reports, and rebuild any custom
queries, in Crystal Reports Version 9.0 or higher.
In addition, a database structure change between P2000 Version 2.3
and 3.12 SP2 affects the Badge and Cardholder records and related
custom reports.
For detailed information, refer to the Crystal Reports documentation
and the P2000 Software User Manual.
P2000 Integrated P2000 software versions earlier than 3.4 used the ID Server software.
Video Imaging When you upgrade from these versions to Version 3.12 SP2, you are
presented with two Video Imaging software choices: ID Server and
EPI Builder.
Select ID Server to continue to use the ID Server software for the
Integrated Video Imaging, and to upgrade ID Setup to the version
currently integrated with P2000.
Select EPI Builder to install the EPI Builder software for the
Integrated Video Imaging option.
For more details about this option, see the P2000 Integrated Video
Imaging Installation and Operation Manual.
CK720/705 and After the upgrade, you may need to manually re-configure at the host
CK721 Panels any CK720/705 and CK721 panels previously configured as version
2.4+ or 2.5+ in order to match the panel type and version. See the
P2000 Software User Manual for further instructions.
3-2
Software Installation Software Upgrade
24-10685-130 Rev. C
Item Note
Integration With To support integration with OSI panels, install Wi-Q Version 3.00.38
OSI Panels prior to upgrading the P2000 software. You must follow specific
instructions to install Wi-Q Version 3.00.38. Contact Technical
Support for details.
Item Note
DVR Integration For integration with On-Net Surveillance Systems (OnSSI) Ocularis,
you must install the OnSSI software development kit (SDK) prior to
loading the P2000 software. This SDK is available from the
manufacturer.
BACnet Interface After the upgrade, all panels, terminals, input points, and output
points will be enabled for those panels that were enabled for BACnet
Interface in version 2.5. If you wish to disable any terminals, input
points, or output points for specific panels, manually disable them
using the Edit Panel dialog.
Custom Reports A database structure change between P2000 Version 2.5 and 3.12
SP2 affects the Badge and Cardholder records and related custom
reports. Contact Technical Support for details.
3-3
Software Installation Software Upgrade
24-10685-130 Rev. C
Item Note
P2000 Integrated P2000 software versions earlier than 3.4 used the ID Server software.
Video Imaging When you upgrade from these versions to Version 3.12 SP2, you are
presented with two Video Imaging software choices: ID Server and
EPI Builder.
Select ID Server to continue to use the ID Server software for the
Integrated Video Imaging, and to upgrade ID Setup to the version
currently integrated with P2000.
Select EPI Builder to install the EPI Builder software for the
Integrated Video Imaging option.
For more details about this option, see the P2000 Integrated Video
Imaging Installation and Operation Manual.
CK720/705 and After the upgrade, you may need to manually re-configure at the host
CK721 Panels any CK720/705 and CK721 panels previously configured as version
2.4+ or 2.5+ in order to match the panel type and version. See the
P2000 Software User Manual for further instructions.
Integration With To support integration with OSI panels, install Wi-Q Version 3.00.38
OSI Panels prior to upgrading the P2000 software. You must follow specific
instructions to install Wi-Q Version 3.00.38. Contact Technical
Support for details.
Item Note
DVR Integration If the Genetec SDK or Milestone SDK are installed, remove them
prior to upgrade using the Windows Add/Remove Programs utility.
For integration with On-Net Surveillance Systems (OnSSI) Ocularis,
you must install the OnSSI software development kit (SDK) prior to
loading the P2000 software. This SDK is available from the
manufacturer.
3-4
Software Installation Software Upgrade
24-10685-130 Rev. C
Item Note
P2000 Integrated When you upgrade to Version 3.12 SP2, you are presented with two
Video Imaging Video Imaging software choices: ID Server and EPI builder.
Select ID Server to install ID Server software for the Integrated Video
Imaging.
Select EPI Builder to install the EPI Builder software for the
Integrated Video Imaging option.
For more details regarding this option, see the P2000 Integrated
Video Imaging Installation and Operation Manual.
CK720/705 and After the upgrade, you may need to manually re-configure at the host
CK721 Panels any CK720/705 and CK721 panels previously configured as version
2.4+ or 2.5+ in order to match the panel type and version. See the
P2000 Software User Manual for further instructions.
Integration With If your P2000 system includes an OSI panels integration, refer to
OSI Panels Installing Stanley® Wi-Q™ System Software for OSI Integrations.
The following components are no longer used in P2000 Version 3.12 and
above; if they are on the P2000 you are upgrading, remove them using the
Windows Add/Remove Programs utility:
• JCI.P2000.ThinClient
• JCI.P2000.ThinClient.WebEngine
• M-Authorize
• M-Graphics
• M-Password
3-5
Software Installation Software Upgrade
24-10685-130 Rev. C
• Web Site
• Web Services
Upgrade Sequence
2. Back up the database. Refer to the P2000 Software User Manual for
instructions.
3. Log off the P2000 workstations and stop all P2000 services.
Obtain a new Registration Key for the P2000 Version 3.12 SP2 before
you begin the upgrade; you need to enter it during the upgrade process.
1. Go to Start > Programs > Johnson Controls > P2000 (or Pegasys
2000) > Register.
3-6
Software Installation Software Upgrade
24-10685-130 Rev. C
3. When you receive an e-mail with the new Registration Key and
additional Option Keys, keep it handy for use and start the upgrade.
First, stop all P2000 services, log off all workstations, and exit the P2000
application.
Install P2000 prerequisites on the server and the workstations. For
instructions, see Installing P2000 Prerequisites on page 4-1. Some
updates may be omitted if they are already installed on your system.
3-7
Software Installation Software Upgrade
24-10685-130 Rev. C
At this point, you have already installed the P2000 prerequisites and have a
valid Registration Key and Option Keys. The Registration Key is necessary to
perform the upgrade. Option Keys are required to register newly added options,
or to register any options on new hardware.
Depending on your system, follow one of the following procedures:
• Upgrading the P2000 Server Using the Same Hardware on page 3-8
• Upgrading the P2000 Server Using New Hardware on page 3-11
The upgrade process is very similar to software installation process. For the
most part, you can follow the instructions for Installing P2000 Software on the
Server on page 4-5. However, unlike during a fresh installation, you will be
prompted to enter the new Registration Key.
NOTE: Before proceeding, stop all P2000 services, log off all workstations, and
exit the P2000 application.
2. Insert the P2000 Software DVD into the drive to start Autorun.
3-8
Software Installation Software Upgrade
24-10685-130 Rev. C
4. Enter the new Registration Key for Version 3.12 SP2. For accuracy,
copy the number from message that you received, and paste it in the
Reg Key field. Click Next.
3-9
Software Installation Software Upgrade
24-10685-130 Rev. C
1. Go to Start > Programs > Johnson Controls > P2000 > Register.
3. In the Add Option Key window, paste the number you have received
into the New Option Key field. You can enter only one number at a
time. Click OK.
4. If you have more than one option to register, repeat steps 2 and 3 until
all numbers are listed in the Register window. To delete an Option
Key, select it from the list and click Delete.
Click OK.
3-10
Software Installation Software Upgrade
24-10685-130 Rev. C
See Important Notes After the P2000 Upgrade on page 3-14 for
additional procedures that may be necessary on your system.
Your upgraded P2000 server software is now ready to configure and
operate. See your P2000 Software User Manual for full configuration and
programming instructions.
3-11
Software Installation Software Upgrade
24-10685-130 Rev. C
• One key for the old version of the P2000 server (“old key”)
• One key for the P2000 software Version 3.12 SP2
4. Register the P2000 software Version 3.12 SP2 on the new hardware
using the Registration Key for Version 3.12 SP2.
5. Start up P2000 and verify that all services are running on the new
server and that the “traffic signal” icon in the system tray displays a
green light.
6. Stop all P2000 services and close the traffic signal icon.
7. Restore the older version of P2000 Data and P2000 Images databases
using the P2000 Backup utility. Refer to the P2000 Software User
Manual for full instructions.
8. If the computer names of the old and new server are not the same, use
the DatabaseImport tool to change the computer name on the new
server. See Changing the Computer Name on page 3-13 for details.
Use Pegasys
update registration set
installkey=“<Installation Key value>”
registrationkey=“<Registration Key value>”
3-12
Software Installation Software Upgrade
24-10685-130 Rev. C
10. Run the P2000 Version 3.12 SP2 software installation again to
upgrade the database. (If you completed previous steps successfully,
during the upgrade process are asked to enter the Registration Key.)
NOTE: Some systems use “Program Files” instead of “Program Files (x86).”
3-13
Software Installation Software Upgrade
24-10685-130 Rev. C
3. Click the browse button next to the lower Server or Domain field.
4. In the Current Servers and Domains window, select an entry and click
OK.
5. The selected entry will appear in the Server or Domain field in the
Database Import window. Click Delete Old Groups.
6. Repeat steps 3-5 until all entries in the Current Servers and Domains
window have been deleted.
7. Verify that the upper Server or Domain field contains the new server
name and click Add Default Logins.
See Important Notes After the P2000 Upgrade on page 3-14 for
additional procedures that may be necessary on your system.
Your upgraded P2000 server software is now ready to configure and
operate. See your P2000 Software User Manual for full configuration and
programming instructions.
Item Note
BACnet If you are using BACnet, perform the following procedures after the
upgrade:
• Enable the P2000 BACnet Service to auto-start
• Enable BACnet interface in Site Parameters
For detailed instructions, refer to the P2000 Metasys Integration
manual.
Web Access If you were previously using the Live Capture feature, uninstall and
reinstall the WebUSB application on Web Access clients
For detailed instructions, refer to the P2000 Web Access manual.
3-14
Software Installation Software Upgrade
24-10685-130 Rev. C
3-15
Software Installation Software Upgrade
24-10685-130 Rev. C
3-16
Software Installation Software Installation
24-10685-130 Rev. C
4. SOFTWARE INSTALLATION
This chapter describes the P2000 prerequisites and software installation on the
server and on the workstations. In the following scenario, P2000 services and
databases are installed on the same server.
NOTE: You can deploy the P2000 Version 3.12 SP2 system in a distributed
mode, where the P2000 server is hosted on two separate machines. All the
P2000 services run on one machine (P2000 application server), while the
P2000 databases are hosted on another machine (P2000 database server). For
information on the distributed deployment mode, refer to the Technical Bulletin
Separating the P2000 Application Server from the Database Server.
NOTE: For integration with On-Net Surveillance Systems (OnSSI) Ocularis, you
must install the OnSSI software development kit (SDK) prior to loading the
P2000 software. This SDK is available from the manufacturer.
4-1
Software Installation Software Installation
24-10685-130 Rev. C
4-2
Software Installation Software Installation
24-10685-130 Rev. C
4-3
Software Installation Software Installation
24-10685-130 Rev. C
6. Enter the computer name of the P2000 Database Server and click
Next.
NOTE: If you are using a custom database instance, use the format:
“database_server\named_instance.”
7. The prerequisites program will check your system and display only
the required updates. Follow the prompts and accept the default
selections to install the prerequisites.
8. The system may restart several times during the installation. Each
time the computer restarts, log in as the system administrator. You
may need to restart the DVD manually.
4-4
Software Installation Software Installation
24-10685-130 Rev. C
9. When all required updates have been installed, the following screen
appears with a “No updates needed” message.
Load the system software on the P2000 server before you install it on the
P2000 workstations.
After the installation, e-mail Johnson Controls for a Registration Key, and then
enter it into the system (see Registering P2000 Software and Options on
page 4-16). If you do not enter the Registration Key, communication between
the server and the panels and workstations terminates on the 10th day after the
initial installation.
If your P2000 system includes options, you also need one or more Option
Keys.
4-5
Software Installation Software Installation
24-10685-130 Rev. C
1. Insert the P2000 Software DVD into the drive to start Autorun.
NOTE: If you select P2000 Server (without Web UI) or Web UI Server,
several of the following screens will be omitted, because they are not
applicable to your selected installation.
4-6
Software Installation Software Installation
24-10685-130 Rev. C
• P2000 Web Access - Select this check box to install files required
for Web Access.
• OSI Interface - Select this check box to install the OSI elements.
Click Next.
NOTE: Support for OSI panels requires IIS Version 6.0 or 7.0. Also, OSI panels
are not supported on systems with Windows Server 2012 or SQL Server 2012.
4-7
Software Installation Software Installation
24-10685-130 Rev. C
4-8
Software Installation Software Installation
24-10685-130 Rev. C
7. If you have selected Badging in the previous step, choose the Video
Imaging software:
• ID Server - Installs the Integrated Video Imaging option using the
ID Server software.
• EPI Builder - Installs the Integrated Video Imaging option using
the EPI Builder software
Click Next.
4-9
Software Installation Software Installation
24-10685-130 Rev. C
IMPORTANT: If you click Select All, remember that only one version of a protocol
can be selected when you click Next.
4-10
Software Installation Software Installation
24-10685-130 Rev. C
11. Enter the computer name of the P2000 Database Server; click Next.
NOTE: Depending on your system configuration, you may be asked to enter this
information later in the installation process.
4-11
Software Installation Software Installation
24-10685-130 Rev. C
12. Enter the Site Name to uniquely identify the P2000 site within the
P2000 Enterprise System. Click Next.
13. Select the method of providing the SSL certificate. Click Next.
NOTE: For instructions on installing SSL certificate on the client side, see the
P2000 Web User Interface (Web UI) - Getting Started manual.
4-12
Software Installation Software Installation
24-10685-130 Rev. C
14. If, in the previous step, you chose to create a self-signed SSL
certificate, select whether or not to export it to the local disk. Click
Next.
15. The P2000 system requires either configuring the P2000 server as
SNTP server, or using a custom mechanism to synchronize time
between the server and the workstations.
To configure the P2000 server as an SNTP server, verify that
Yes is selected; if you are using a different time server, select
No. Click Next to continue.
4-13
Software Installation Software Installation
24-10685-130 Rev. C
16. To set this server as the Authoritative Time Server (for synchronizing
time with another computer or the Internet), select Yes and click Next.
17. Some operating systems: If you have not selected this server as the
Authoritative Time Server, you will be asked to use the P2000 Time
Service. Verify that Yes is selected and click Next.
4-14
Software Installation Software Installation
24-10685-130 Rev. C
18. The system displays current settings. Click Next to begin copying
files. This will take a few minutes.
4-15
Software Installation Software Installation
24-10685-130 Rev. C
4-16
Software Installation Software Installation
24-10685-130 Rev. C
• The Installation Key number (cut and paste the number to avoid
mistakes).
• The 7-digit AOMS number, as found on the Registration of
Options form.
• End user name, city, and state.
• Upgrades only: Serial number, as found in the System
Configuration screen.
Once you have received the keys, you can register the software. Enter the
Registration Key before entering the Option Keys.
4-17
Software Installation Software Installation
24-10685-130 Rev. C
1. When you receive the Registration Key, go to Start > Programs >
Johnson Controls > P2000 > Register.
2. Cut and paste the number you have received into the New
Registration Key field in the Register dialog box, click OK.
1. When you receive the Option Keys, go to Start > Programs >
Johnson Controls > P2000 > Register.
4-18
Software Installation Software Installation
24-10685-130 Rev. C
3. In the Add Option Key window, paste the number you have received
into the New Option Key field in the Register dialog box. You can
enter only one number at a time. Click OK.
4. If you have more than one option to register, repeat steps 2 and 3 until
all numbers are listed in the Register window. To delete an Option
Key, select it from the list and click Delete.
Click OK.
4-19
Software Installation Software Installation
24-10685-130 Rev. C
Starting P2000
Until the software is properly registered, every time you restart the
computer and launch the P2000 software, you will receive a message
about the number of days left for registration.
You must be logged on as system administrator.
To start P2000:
4-20
Software Installation Software Installation
24-10685-130 Rev. C
BACnet Procedures
2. Insert the P2000 Software DVD into the drive to start Autorun.
4-21
Software Installation Software Installation
24-10685-130 Rev. C
4-22
Software Installation Software Installation
24-10685-130 Rev. C
7. If you have selected Badging in the previous step, choose the Video
Imaging software:
4-23
Software Installation Software Installation
24-10685-130 Rev. C
4-24
Software Installation Software Installation
24-10685-130 Rev. C
10. Enter the computer name of the P2000 Database Server; click Next.
(Depending on your system configuration, you may be asked to enter
this information later in the installation process.)
NOTE: If you are using a custom database instance, use the format:
“database_server\named_instance.”
4-25
Software Installation Software Installation
24-10685-130 Rev. C
Click Next.
NOTE: You can select Do not change the time configuration settings for this
workstation and continue the installation. However, you must later manually
configure this workstation with time synchronization method. If you select this
option, two information screens will appear to confirm your choice and remind
you of the time synchronization requirement.
4-26
Software Installation Software Installation
24-10685-130 Rev. C
12. If you selected Use a different SNTP (Time) server in the previous
step, you will be asked to specify the name or IP address of an SNTP
server to be used for time synchronization. Enter the server’s name or
IP address and click Next.
13. The system will display current settings. Click Next to begin copying
files. This will take a few minutes.
4-27
Software Installation Software Installation
24-10685-130 Rev. C
14. Remove the DVD and click Finish to restart the computer.
4-28
Software Installation Software Installation
24-10685-130 Rev. C
NOTE: Johnson Controls recommends that you make a copy of the operating
system and store it in case of hard drive failure.
NOTE: Some systems use “Program Files” instead of “Program Files (x86).”
4. In the Switch P2000 database server to: field, change the Server
Name from “P2000” to the computer name of your P2000 Server.
NOTE: If you are using a custom database instance, use the format:
“database_server\named_instance.”
4-29
Software Installation Software Installation
24-10685-130 Rev. C
You can uninstall P2000 and related software using the standard Windows Add/
Remove Programs utility.
When you uninstall the P2000 server software, you have a choice whether to
also remove or retain the following components:
• The database (stop P2000 services prior to uninstalling the database)
• Badge image layouts
• User groups
• Dial-up accounts (when applicable)
You need to uninstall the following software separately:
• EPI Builder
• OSI Web Services
• Third-party software development kits (SDKs)
1. Back up the database. Refer to the P2000 Software User Manual for
instructions.
2. Back up the Web Access files located in the following directory and
its subdirectories:
webroot/p2ktc/config
TROUBLESHOOTING
The P2000 software installation process creates the log file, P2000Install.log,
in the C:\ directory. This log allows Johnson Controls Technical Support to
debug the installation process.
4-30
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
OVERVIEW
ASSA ABLOY Intelligent Locks provide a wired and wireless door locking
security solution that can be integrated with the P2000 SMS.
Integration between these two systems is possible via communications between
the ASSA ABLOY Door Service Router (DSR), which is installed on its own
server, and the P2000 ASSA ABLOY DSR Interface Service, which runs on a
P2000 Server in the P2000 SMS.
Commissioning of the ASSA ABLOY locks requires the use of the Lock
Configuration Tool (LCT) and the Network Configuration Tool (NCT). You
can install the LCT and the NCT from the P2000 installation disk. Look in the
Assa Abloy Resources / NCT_LCT folder for the NCT/LCT manual and an
installer that installs both applications.
You can encrypt the connection between an ASSA ABLOY lock and the DSR
using one of the supported encryption protocols using the LCT and NCT.
Encryption between a lock and the DSR is not encrypted by default; you must
turn it on manually.
A-1
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
ASSA ABLOY
P2000 Server Wired Locks
P2000
Workstation
Wide Area
Network
IP Network
DSR Server
- Operating System
- Database Engine ASSA ABLOY
- DSR Software Package Wireless Locks
P2000 Server
P2000
Workstation
Wide Area
Network
IP Network
A-2
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
A-3
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
The installation process for the DSR server software is different, based on your
choice of Windows OS/SQL Server combination:
• Windows Server 2008 R2 / SQL Server Standard 2008 R2
• Windows 7 / SQL Server Express 2008 R2
If you are supporting more than 128 locks, and thus must use the Windows
Server 2008 R2 / SQL Server Standard 2008 R2 combination, there is one
software installation path for the DSR server: Install Windows Server 2008 R2,
then install SQL Server Standard 2008 R2, and finally install the DSR server
5.0 software.
This installation of the DSR software is described in Installing the DSR
Software on a Windows Server 2008 R2 System with SQL Server Standard
2008 R2 Already Installed on page A-5.
If you are supporting fewer than 128 locks, and thus are using the Windows 7 /
SQL Server Express 2008 R2 combination, you must choose between two
software installation paths for the DSR server software:
• Option 1: You have a Windows 7 (64-bit) / SQL Server Express 2008 R2
system already set up and you just need to install the DSR server software
on that system. This installation of the DSR software is described in
Installing the DSR Server Software on a Windows 7 System with SQL
Server Express Already Installed on page A-7.
• Option 2: You have a Windows 7 (64-bit) system set up but it does not
have SQL Server Express 2008 R2, so you need to install SQL Server
Express during the DSR server installation (this is a feature of the DSR
server installer application). This installation of the DSR software is
described in Installing the DSR Server Software and SQL Server Express at
the Same Time on page A-10.
A-4
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
This installation requires that Windows Server 2008 R2 and SQL Server
Standard 2008 R2 are already installed on the system.
A-5
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
NOTE: The PostgresSQL Server and Internal Database options shown on this
screen are not supported in an integration with a P2000 SMS.
8. On the JRE Installation Required screen, read the text, then click
Next.
9. On the SQL Server Login screen, enter appropriate values, then click
Next:
Field Action
A-6
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
Field Action
10. On the Completing the Door Service Router (DSR) Setup screen,
make the appropriate selections, then click Finish.
This installation procedure covers installing the DSR server 5.0 software on a
Windows 7 system where SQL Server Express 2008 R2 is already installed.
A-7
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
4. On the License Agreement screen, read the text, check I accept the
terms of the License Agreement, then click Next.
NOTE: The PostgresSQL Server and Internal Database options shown on this
screen are not supported in an integration with a P2000 SMS.
8. On the JRE Installation Required screen, read the text, then click
Next.
A-8
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
9. On the SQL Server Login screen, enter appropriate values, then click
Next.
Field Action
10. On the Choose Start Menu Folder screen, specify a Start menu
folder for the DSR shortcuts, then click Install.
A-9
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
11. On the Completing the Door Service Router (DSR) Setup screen,
make the appropriate selections, then click Finish.
Installing the DSR Server Software and SQL Server Express at the Same
Time
This procedure covers installing the DSR server 5.0 software on a Windows 7
system that does not have SQL Server Express 2008 R2 already installed.
To install the DSR server 5.0 software and SQL Server Express 2008
R2 at the same time:
4. On the License Agreement screen, read the text, check I accept the
terms of the License Agreement, then click Next.
A-10
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
NOTE: The PostgresSQL Server and Internal Database options are not
supported in an integration with a P2000 SMS.
8. On the JRE Installation Required screen, read the text, then click
Next.
A-11
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
9. On the SQL Server Login screen, enter appropriate values, then click
Next.
Field Action
10. On the Choose Start Menu Folder screen, accept the default Start
menu folder for the DSR shortcuts or enter the desired folder, then
click Install.
A-12
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
11. On the Completing the Door Service Router (DSR) Setup Wizard
screen, make the appropriate selections, then click Finish.
When logging to SQL Server Express, make sure the Server name field is
configured appropriately.
NOTE: This issue affects SQL Server Express only; not SQL Server Standard.
A-13
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
You must configure the DSR server appropriately to work in a P2000 SMS
integration. Specifically, you must:
• Change several Environment name settings: You need to change three
settings in two different files on the system hosting the DSR server.
• Check two SQL Server database settings: You need to make sure the
Initial Size (MB) and the Autogrowth settings are appropriate, so that the
SQL Server transaction log does not fill up, which causes the DSR server to
stop working correctly.
• Configure Windows 7 as a server (Windows 7 only): If the system
hosting your DSR server is running on Windows 7, make sure it is
configured as a server, including Windows Power Options settings.
C: \Program Files\DSR\apache-tomcat\conf\Catalina\localhost
2. Right-click the dsr.xml file and open it in a text editor; Notepad, for
example.
3. Locate the following text and ensure the value is set to “false”:
4. Locate the following text and ensure the value is set to “1024”:
<Environment name=“dsr.limit.core.
accesspoint.confirm.max” value=“1024”
5. Locate the following text and ensure the value is set to “1024”:
<Environment name=“dsr.limit.core.
authorization.accesspointcount.max” value=“1024”
A-14
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
Because the Assa Abloy DSR stops working if the SQL Server database
or the transaction log gets full, you need to take steps to prevent that.
To ensure neither your SQL Server database or transaction log gets full:
• On the Database Properties screen for your DSR database in SQL
Server, make sure the database and the transaction log are both set to
256 MB (the default) if you have 256 or fewer locks or to 1 MB per
lock if you have more than 256 locks.
• Also on the Database Properties screen, make sure Autogrowth is
enabled for the database and the transaction log, and that Maximum
File Size is set to Unrestricted File Growth.
• Establish a database maintenance plan that schedules automatic DSR
database backups and transaction log backups.
A-15
Software Installation ASSA ABLOY Integration
24-10685-130 Rev. C
1. Navigate to Control Panel > System and Security > Power Options.
A-16
Security Solutions