9 Data

Center g
Home > Data center design and facilities

Tech Accelerator
How to design and build a data center

TIP

Considerations for sustainable data center design


To design a green, sustainable data center, consider methods to improve energy conservation and efficiency. Then,
look into green -- or greener -- energy source alternatives.

Robert McFarlane, Shen Milsom & Wilke LLC


Published: 27 Sep 2021

Most businesses want their buildings, even data centers, to be "net zero" by 2050, which means they source
all energy from renewable sources with zero addition of CO2 to the atmosphere. Achieving net zero requires
a three-pronged data center design approach: energy conservation, energy efficiency and renewable,
preferably on-site energy sources.

Now, as more organizations seek to design their data centers -- or redesign and upgrade them -- for
environmental sustainability than ever before, consider how to move your facility toward net zero. This could
lead to long-term savings, as well as contributing to the improved health of the planet.

A history of sustainability through temperature and humidity


The Uptime Institute's push for hot aisle/cold aisle data center layout in the 1980s began the trend toward
greener data centers. Aisle containment complements this approach by improving both the cooling and
energy efficiency of this layout.

Thermal Guidelines for Data Processing Environments, published in 2004 by Technical Committee TC 9.9 of
the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) recommended
increasing air inlet air temperatures to data processing equipment to as high as 27 degrees C or 80.6
degrees F -- far hotter than the previous 12.8 degrees C or 55 degrees F recommendation at which most
data centers operated. Higher temperatures yield a reduction in cooling energy.

THIS ARTICLE IS PART OF

 How to design and build a data center


Which also includes:

Get started with green energy for your data center

How to calculate data center cooling requirements


Data center backup generators for mission-critical loads

In 2007, The Green Grid published the Power Usage Effectiveness (PUE) metric, which became the defacto
standard of power efficiency monitoring. Because data centers use so much electricity, you must know and
track your data center's energy usage in order to increase sustainability. When the Green Grid first
introduced PUE, measurements of 2.5 to 3.5 were the norm. Widespread monitoring of PUE has driven
numbers down to levels of 1.5 or better. The best cloud and hyperscale facilities now run as low as 1.1 PUE.
You don't have to sacrifice either performance or reliability in order to achieve lower PUE numbers.

In 2014, ASHRAE released research showing that legacy relative humidity (RH) levels of 45%-55% were
unnecessary for avoiding static discharge, and that RH as low as 8% still caused no static damage to
mounted and properly grounded IT hardware. Evaporating water for humidification uses a lot of energy,
which means you can find another huge reduction in energy waste by reducing RH levels in your data center.

By designing with best practices in mind and implementing air containment, you can conserve a lot of
energy, maximizing the first factor in sustainability. You can also consider implementing direct or indirect
liquid cooling.

Sustainable hardware
You can also find much more efficient computer processing hardware, UPS systems and cooling equipment.
"Energy Star"-rated servers significantly improve energy efficiency, especially when IT hardware runs close
to maximum utilization. You can also shut down unused servers, replace older hardware with high-efficiency
equipment and make full use of energy efficiency features to help minimize idle state power consumption.
Consolidation and virtualization also improve hardware efficiency.

Consider implementing high-efficiency power and cooling infrastructure in your data center. This includes
transformerless, modular UPSes run at high capacity, higher voltage equipment operation, close coupled in-
row or overhead cooling, aisle containment, liquid-cooled rear door heat exchangers, full liquid immersion
cooling and direct liquid-to-chip cooling.

Renewable energy
Depending on what steps you take to achieve energy conservation and efficiency, the remaining challenge is
transitioning to clean renewable energy. Even the best data centers use a lot of energy, and attempts at
running large data centers on 100% solar have pretty much failed. The number of solar panels required just
take too much space. Operators of large facilities have advantages smaller data centers can't match, such
as including hydro or wind power in their site selection criteria.

Consider implementing fuel cells for on-site generation, particularly when you can use methane from land
fills. This enables you to use nonfossil fuels, eliminates long transmission losses and helps you reclaim the
substantial heat produced by these devices. However, cells aren't perfect. They still produce a carbon
footprint, but it's a smaller footprint than oil or coal power generation produces.

ASHRAE Standard 90.4 -- the Energy Standard for Data Centers -- now incorporates credits for on-site
renewables and heat reclaim.
5 Data Center Design Considerations

m Next Steps
Data center temperature and humidity guidelines

m Dig Deeper on Data center design and facilities


Words to go: 6 key data center sustainability metrics

By: Ryan Arel

Building the sustainable HPC environments of the future

How to design and build a data center

By: Stephen Bigelow

green data center


By: Paul Kirvan

WINDOWS SERVER CLOUD COMPUTING STORAGE

SearchWindowsServer

Learn by doing with these PowerShell regex examples


When you must find specific text in a large file, such as a system log, regular expressions can come to the rescue. Learn how to ...

June Patch Tuesday settles two Exchange Server bugs


Microsoft's plans for upcoming security hardening in Kerberos and Netlogon protocols will have admins busy with testing over the ...

About Us Editorial Ethics Policy Meet The Editors Contact Us Advertisers Partner with Us Media Kit Corporate Site

Contributors Reprints Answers Definitions E-Products Events Features

Guides Opinions Photo Stories Quizzes Tips Tutorials Videos

All Rights Reserved,


Copyright 2000 - 2023, TechTarget

Privacy Policy

Do Not Sell or Share My Personal Information

You might also like