1 2 3 4 5 6 7 8 9 10 11 12

SOURCE 11kV LOAD


EXISTING
SOURCE SIDE
A HV MAINS A

230
2-1 OR 2-11 CONSTRUCTION
10

10
11KV HV DOLF CONSTRUCTION
(REFER DRG : A4-566092 FOR STANDARD)
NEW FUSE
LV OPEN WIRE
HV SUPPLY
TO CAPACITOR BANK
11
17 13

9 12
1500

U
U
P
P

TERMINATE EXISTING INSTALL NEW LV ABC 14 15 16


OPEN WIRE LV FROM THIS POLE TO POLE
ABC POLE TERMINATION
B BEYOND CAPACITOR POLE (SHEET 1) B
A A A N

NEW
DELETE CROSSARM IF EXISTING
LV ABC
LV ABC IS INSTALLED LV OPEN WIRE
BACK TO THE NEXT POLE INSTALL LV ABC WHERE
MID-SPAN CLEARANCE
CAN BE ACHIEVED
4000

PORTABLE EARTH
POINT
EXISTING

POLE STEPS
@450mm CENTRE
C C
THE CT IS TO MEASURE
LOAD CURRENT ONLY
NOT LOAD CURRENT
AND CAPACITOR CURRENT.

SOURCE 11kV LOAD

I
S = IL+ IC
LOAD CURRENT I
L
10200 MAXIMUM

NEW 11kV MAINS


8
P
P
U
U

CAPACITOR CURRENT I
C
P

P
U

7 L
6000 MINIMUM

D NEW CAPACITOR POLE D


a2 a3 a1 SINGLEPHASE 11kV/240V
SEE SHEET 1
a4 V.T BUILT TO NS 122
18
WEATHERPROOF ENCLOSURE
WITH 32A CIRCUIT BREAKER

LV OPEN WIRE LV OPEN WIRE


OR 3%%c LV ABC 3%%c LV ABC OR
LV ABC LV ABC
1%%c LV ABC INSTALL LV ABC WHERE
MID-SPAN CLEARANCE
CAN BE ACHIEVED
TO FIRST POLE STEP
3600

E E

DETAIL WHERE NO LV SUPPLY


PROPOSED IS AVAILABLE AND A V.T IS
TO BE INSTALLED

GROUND LINE GROUND LINE

F F
300
500

18 CLAMP - HENLEY, B26 H18815


5
17 FUSE - 12/24kV, 8kA, EXPULSION H84350

16 NUT - M16, NYLOC, STAINLESS STEEL 177122


4
15 BOLT - M16 x 40mm, HEX, STAINLESS STEEL H38413

14 CLAMP - LV ABC H113472


HV EARTH

2
13 BRACKET - TWISTED 176901
3 x EARTH ROD MIN
EXISTING

12 INSULATOR - LONGROD, 22kV 150375

3 11 BRACE - 720 x 38 x 38 x 5mm ANGLE, GALVANISED 99119

10 CROSSARM - 2400 x 150 x 100mm 71589


REFER TO NS 116 FOR
TARGET MINIMUM RESISTANCE 9 BOLT - M12 x 90mm, COACH, GALVANISED 50443

8 POLE STEPS H17720

7 TROUGHING - TO SUIT EARTHING CABLES, PVC 157552


G G
6 COVER - CABLE, PVC, 150 x 1200mm 151100

5 CABLE - COPPER, 70mm 1/8 , PVC INSULATED 60111

4 CONNECTOR - TO SUIT 15mm EARTH ROD H31699

3 COUPLER - TO SUIT 15mm EARTH ROD H31649

2 EARTH ROD - 15 x 1800mm COPPER CLAD H31631

ALL DIMENSIONS IN MILLIMETRES DO NOT SCALE CONSTRUCTION ISSUE 1

ITEM
POLE - WOOD, EXISTING

DESCRIPTION STOCK CODE


FROM GL TO EDO ARM SHOWN.
LOAD AND SOURCE DESIGNATION

SCALE 1:25
DO NOT MANUALLY AMEND

STANDARD CONSTRUCTION
W.G

W.G

EARTH ROD DETAIL ALTERED.


MAXIMUM DISTANCE 10200mm
A M E N D M E N T S

CURRENT TO BE MEASURED.

AUTH’D by: WILLIAM GRAHAM


AUTH’D by: WILLIAM GRAHAM
AUTH’D by: WILLIAM GRAHAM
ADDED NOTE DETAILING CT

BARBARA BARSKI
BARBARA BARSKI
BARBARA BARSKI
CAD DRAWING

CHKED: WILLIAM GRAHAM


CHKED: WILLIAM GRAHAM
CHKED: WILLIAM GRAHAM

DESIGNED W.GRAHAM
LV CROSSARM MOVED TO

AMENDMENT 0 ISSUED AS

W.GRAHAM

W.GRAHAM

ABB - 12kV POLE MOUNT CAPACITOR BANK CONTROL WIRING DIAGRAM A3-166887
11KV POLE TOP CAPACITORS
CHKED:

CHKED:

DRAWN PATRICIA RIOS


OTHER SIDE OF POLE.

04/05/2006
INITIAL ISSUE

10/11/2005
11/10/2005

ABB - 1MVAR, 12kV CAPACITOR BANK INSTALLATION INSTRUCTIONS A3-166888


27/04/05
15/09/04

CHECKED B GRAHAM
MODIFICATION TO EDO POLE
AMENDMENT 01.

ABB - DRY TYPE AIR CORE CURRENT LIMITING REACTOR 1-25413


H APPROVED R HUGHES H
DESIGN
CONSTRUCTION DETAIL
DWN: B.B.
DWN: P.R

AUTH’D by:

AUTH’D by:
REVERSED.

ABB - RACK - 6 UNITS POLE MOUNT - ENERGY AUSTRALIA X7016194 145 NEWCASTLE RD WALLSEND, NSW 2287
DATE 02/09/04
2 DATE:

3 DATE:

6 DATE:
DATE:
DATE:

TEL: 4951 9388 FAX: 4951 9389


DWN:
DWN:
DWN:

ABB - PROPOSED ENERGY AUSTRALIA 1MVar 12kV POLE MOUNT BANK WITH RIPPLE BLOCKING A3-166885 PRJTRK No.

A Business of PROJECT
Enerserve NET STD 162475 02 6 A1
0

ASSOCIATED DRAWINGS DRAWING No SHEET AMD SIZE


5
4

EnergyAustralia NUMBER